Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.T...Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value.展开更多
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of...A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.展开更多
A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre...A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.展开更多
The studies on predicting the energy consumption of air conditioning systems are meaningful to building energy conservation and management. Generally, the more comprehensive the building information is, the easier the...The studies on predicting the energy consumption of air conditioning systems are meaningful to building energy conservation and management. Generally, the more comprehensive the building information is, the easier the prediction model can be developed. However, it is very difficult to get detailed information about existing/old buildings (information-poor buildings), it is a big challenge to predict the energy consumption accurately by limited information. This study aims to predict the electricity consumption of the water source heat pump system of an office building based on meteorological data. The key variables are selected by error analysis and sensitivity analysis, and the effects of each variable on the models’ prediction performance can be obtained. Besides, the prediction models are established by support vector regression algorithm and trained by the local meteorological data. The results show that the positive and negative variables can be identified, and these positive variables are responsible for more than 70% of the total importance. Moreover, the root mean square error falls to 4.6044 from 7.8227 and the relative square error falls to 0.1494 from 0.4313 when the negative inputs are removed. And the errors reduce further to 4.1160 and 0.1194 by parameter optimization.展开更多
Based on energy conservation equation and Darcy's law, a model of beach well infiltration intake system applied in a seawater source heat pump system was established. The model consists of the seawater seepage and th...Based on energy conservation equation and Darcy's law, a model of beach well infiltration intake system applied in a seawater source heat pump system was established. The model consists of the seawater seepage and the heat transfer process. A porous medium model in a software named FLUENT was applied to simulate the seepage and the heat transfer process. This model was also validated by field experiment conducted on the seashore in Tianjin, China. The maximum relative error between simulation results and experimental results was 2.1% (less than 5%), which was acceptable in engineering applica- tion. The porosity and coefficient of thermal conductivity of the aquifer soil were determined to be 0.49 W/(m. K) and 1.46W/(m.K), respectively in the simulation. In addition, the influencing factors of pumping water of beach well were also analyzed. The pumping water was found to increase when the distance between the beach well and the impervious boundary becomes longer, when the distance between the beach well and the supplying water source shortens, when the diameter of the beach well enlarges, and the drawdown enlarges.展开更多
基金supported by the China Postdoctoral Science Foundation(20080430747)foundation of Chongqing University Young Talents for Promoting the Innovative Force(qnjj2008-7)
文摘Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value.
基金the National Natural Science Foundation of China(No.51776117)。
文摘A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.
基金supported by the National Natural Science Foundation of China (Grant No. 51076147)
文摘A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value.
基金This work was supported by the National Natural Science Foundation of China(No.51876070,No.51576074).
文摘The studies on predicting the energy consumption of air conditioning systems are meaningful to building energy conservation and management. Generally, the more comprehensive the building information is, the easier the prediction model can be developed. However, it is very difficult to get detailed information about existing/old buildings (information-poor buildings), it is a big challenge to predict the energy consumption accurately by limited information. This study aims to predict the electricity consumption of the water source heat pump system of an office building based on meteorological data. The key variables are selected by error analysis and sensitivity analysis, and the effects of each variable on the models’ prediction performance can be obtained. Besides, the prediction models are established by support vector regression algorithm and trained by the local meteorological data. The results show that the positive and negative variables can be identified, and these positive variables are responsible for more than 70% of the total importance. Moreover, the root mean square error falls to 4.6044 from 7.8227 and the relative square error falls to 0.1494 from 0.4313 when the negative inputs are removed. And the errors reduce further to 4.1160 and 0.1194 by parameter optimization.
基金This work was supported by the National Natural Science Foundation of China (Grant No. 51106110).
文摘Based on energy conservation equation and Darcy's law, a model of beach well infiltration intake system applied in a seawater source heat pump system was established. The model consists of the seawater seepage and the heat transfer process. A porous medium model in a software named FLUENT was applied to simulate the seepage and the heat transfer process. This model was also validated by field experiment conducted on the seashore in Tianjin, China. The maximum relative error between simulation results and experimental results was 2.1% (less than 5%), which was acceptable in engineering applica- tion. The porosity and coefficient of thermal conductivity of the aquifer soil were determined to be 0.49 W/(m. K) and 1.46W/(m.K), respectively in the simulation. In addition, the influencing factors of pumping water of beach well were also analyzed. The pumping water was found to increase when the distance between the beach well and the impervious boundary becomes longer, when the distance between the beach well and the supplying water source shortens, when the diameter of the beach well enlarges, and the drawdown enlarges.