To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry ...To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.展开更多
An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading,...An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading, washing, and eluting) used a flow rate of1.0 m L/min, and dicyandiamide was eluted with 20 m L of a methanol/acetonitrile mixture(V/V = 2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography–ultraviolet spectroscopy(HPLC–UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge(with activated carbon).Separation was achieved on a ZIC-Hydrophilic Interaction Liquid Chromatography(ZIC-HILIC)(50 mm × 2.1 mm, 3.5 μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions(R^2〉 0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations(RSDs, n = 3) were below 6.1% with a detection limit of 5.0 ng/m L for stream water samples.展开更多
基金supported by the Preventive medicine and public health research project of Anhui,China(No.2011Y0103)the Natural Science Foundation of Anhui,China(No.11040606M216)
文摘To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%.
基金Department of Chemistry at Mississippi State University for financial support for this project
文摘An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction.The extraction procedure(including loading, washing, and eluting) used a flow rate of1.0 m L/min, and dicyandiamide was eluted with 20 m L of a methanol/acetonitrile mixture(V/V = 2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography–ultraviolet spectroscopy(HPLC–UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge(with activated carbon).Separation was achieved on a ZIC-Hydrophilic Interaction Liquid Chromatography(ZIC-HILIC)(50 mm × 2.1 mm, 3.5 μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions(R^2〉 0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations(RSDs, n = 3) were below 6.1% with a detection limit of 5.0 ng/m L for stream water samples.