期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Wind-induced vibration control of bridges using liquid column damper 被引量:3
1
作者 薛素铎 高赞明 徐幼麟 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2002年第2期271-280,共10页
The potential application of tuned liquid column damper (TLCD) for suppressing wind-induced vibration of long span bridges is explored in this paper.By installing the TLCD in the bridge deck,a mathematical model for t... The potential application of tuned liquid column damper (TLCD) for suppressing wind-induced vibration of long span bridges is explored in this paper.By installing the TLCD in the bridge deck,a mathematical model for the bridge-TLCD system is established.The governing equations of the system are developed by considering all three displacement components of the deck in vertical,lateral,and torsional vibrations,in which the interactions between the bridge deck,the TLCD,the aeroelastic forces,and the aerodynamic forces are fully reflected.Both buffeting and flutter analyses are carried out.The buffeting analysis is performed through random vibration approach,and a critical flutter condition is identified from flutter analysis.A numerical example is presented to demonstrate the control effectiveness of the damper and it is shown that the TLCD can be an effective device for suppressing wind-induced vibration of long span bridges,either for reducing the buffeting response or increasing the critical flutter wind velocity of the bridge. 展开更多
关键词 long span bridge bridge deck wind-induced vibration vibration control FLUTTER BUFFETING tuned liquid column damper TLCD-bridge interaction mathematical model
下载PDF
Wind-Induced Vibration Control for Substation Frame on Viscous Damper 被引量:1
2
作者 Bingji Lan Kanghao Yan 《Computers, Materials & Continua》 SCIE EI 2020年第3期1303-1315,共13页
In order to study the wind-induced vibration control effect of the viscous damper on the large-scale substation frame,this paper takes the large-scale 1000 kV substation frame of western Inner Mongolia as an example.T... In order to study the wind-induced vibration control effect of the viscous damper on the large-scale substation frame,this paper takes the large-scale 1000 kV substation frame of western Inner Mongolia as an example.The time-history sample of pulsating wind load is simulated by harmonic superposition method based on Matlab software.6 kinds of viscous damper arrangement schemes have been designed,and SAP2000 finite element software is used for fine modeling and input wind speed time history load for nonlinear time history analysis.The displacement and acceleration of a typical node are the indicators of wind vibration control.The wind-induced vibration control effects of different schemes under different damping parameters have compared,and the damping parameters are analyzed for the optimal layout scheme.The results show that a viscous damper has installed in the lower layers of the substation;a viscous damper is placed between the ground column and the lattice beam.It is an integrated optimal solution.The wind-induced vibration control effect of the optimal scheme is sensitive to the viscous damper parameters,and the control effect does not increase linearly with the increase of the damping index and the damping coefficient.Corresponding to different damping indexes,the damping coefficient has a better range of values. 展开更多
关键词 Viscous damper wind-induced vibration control arrangement plan damping coefficient damping index
下载PDF
Application of Lead Viscoelastic Dampers to Wind Vibration Control on Big-Span Power Transmission Tower 被引量:1
3
作者 梁政平 李黎 +1 位作者 尹鹏 段松涛 《Journal of Southwest Jiaotong University(English Edition)》 2008年第4期320-328,共9页
To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and for... To study the wind vibration response of power transmission tower, the lead viscoelastic dampers (LVDs) were applied to a cup tower. With time history analysis method, the displacement, velocity, acceleration and force response of the tower was calculated and analyzed. The results show that the control effect of lead viscoelastic dampers is very good, and the damping ratio can reach 20% or more when they are applied to the tower head. 展开更多
关键词 Transmission tower Lead viscoelastic damper wind-induced vibration control
下载PDF
Wind-induced vibration control of Hefei TV tower with fluid viscous damper
4
作者 Zhiqiang ZHANG Aiqun LI +1 位作者 Jianping HE Jianlei WANG 《Frontiers of Structural and Civil Engineering》 SCIE EI 2009年第3期249-254,共6页
The Hefei TV tower is taken as an analytical case to examine the control method with a fluid viscous damper under wind load fluctuation.Firstly,according to the random vibration theory,the effect of fluctuating wind o... The Hefei TV tower is taken as an analytical case to examine the control method with a fluid viscous damper under wind load fluctuation.Firstly,according to the random vibration theory,the effect of fluctuating wind on the tower can be modeled as a 19-dimensional correlated random process,and the wind-induced vibration analysis of the tower subjected to dynamic wind load was further obtained.On the basis of the others'works,a bi-model dynamic model is proposed.Finally,a dynamic model is proposed to study the wind-induced vibration control analysis using viscous fluid dampers,and the optimal damping coefficient is obtained regarding the wind-induced response of the upper turret as optimization objectives.Analysis results show that the maximum peak response of the tower under dynamic wind load is far beyond the allowable range of the code.The wind-induced responses and the wind vibration input energy of the tower are decreased greatly by using a fluid viscous damper,and the peak acceleration responses of the upper turret is reduced by 43.4%. 展开更多
关键词 high-rise structure wind-induced response fluid viscous damper vibration control
原文传递
Research and Implementations of Structural Monitoring for Bridges and Buildings in Japan 被引量:8
5
作者 Yozo Fujino Dionysius MSiringoringo +2 位作者 Yoshiki Ikeda Tomonori Nagayama Tsukasa Mizutani 《Engineering》 SCIE EI 2019年第6期1093-1119,共27页
This paper provides a review on the development of structural monitoring in Japan, with an emphasis on the type, strategy, and utilization of monitoring systems. The review focuses on bridge and building structures us... This paper provides a review on the development of structural monitoring in Japan, with an emphasis on the type, strategy, and utilization of monitoring systems. The review focuses on bridge and building structures using vibration-based techniques. Structural monitoring systems in Japan historically started with the objective of evaluating structural responses against extreme events. In the development of structural monitoring, monitoring systems and collected data were used to verify design assumptions, update speci cations, and facilitate the ef cacy of vibration control systems. Strategies and case studies on monitoring for the design veri cation of long-span bridges and tall buildings, the performance of seismic isolation systems in building and bridges, the veri cation of structural retro t, the veri cation of structural control systems (passive, semi-active, and active), structural assessment, and damage detec- tion are described. More recently, the application of monitoring systems has been extended to facilitate ef cient operation and effective maintenance through the rationalization of risk and asset management using monitoring data. This paper also summarizes the lessons learned and feedback obtained from case studies on the structural monitoring of bridges and buildings in Japan. 展开更多
关键词 Structural monitoring Long-span bridge High-rise building Seismic monitoring wind-induced responses Pavement and slab monitoring Structural control monitoring Structural assessment
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部