Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has a...Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has also been recently demonstrated in both bulk materials and thin films.However,the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours,often reporting degradation of the detection performance.Here it is shown that self-powered direct X-ray detectors,fabricated starting from a FAPbBr_(3)submicrometer-thick film deposition onto a mesoporous TiO_(2)scaffold,can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss,demonstrating ultra-high operational stability and excellent repeatability.No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy,revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film.In addition,trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy^(−1)cm^(−3)at 0 V,an unprecedented value in the field of thin-film-based photoconductors and photodiodes for“hard”X-rays.Finally,prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced.展开更多
Low-dimensional halide perovskites have become the most promising candidates for X-ray imaging,yet the issues of the poor chemical stability of hybrid halide perovskite,the high poisonousness of lead halides and the r...Low-dimensional halide perovskites have become the most promising candidates for X-ray imaging,yet the issues of the poor chemical stability of hybrid halide perovskite,the high poisonousness of lead halides and the relatively low detectivity of the lead-free halide perovskites which seriously restrain its commercialization.Here,we developed a solution inverse temperature crystal growth(ITCG)method to bring-up high quality Cs_(3)Cu_(2)I_(5)crystals with large size of centimeter order,in which the oleic acid(OA)is introduced as an antioxidative ligand to inhibit the oxidation of cuprous ions effieiently,as well as to decelerate the crystallization rate remarkalby.Based on these fine crystals,the vapor deposition technique is empolyed to prepare high quality Cs_(3)Cu_(2)I_(5)films for efficient X-ray imaging.Smooth surface morphology,high light yields and short decay time endow the Cs_(3)Cu_(2)I_(5)films with strong radioluminescence,high resolution(12 lp/mm),low detection limits(53 nGyair/s)and desirable stability.Subsequently,the Cs_(3)Cu_(2)I_(5)films have been applied to the practical radiography which exhibit superior X-ray imaging performance.Our work provides a paradigm to fabricate nonpoisonous and chemically stable inorganic halide perovskite for X-ray imaging.展开更多
The“People’s Films,”when examined from the perspective of classical aesthetics,present a unique visual style that creates artistic conceptions through sparse filming and deliver a scenery-based ideology through bac...The“People’s Films,”when examined from the perspective of classical aesthetics,present a unique visual style that creates artistic conceptions through sparse filming and deliver a scenery-based ideology through background shots,contributing to the overall aesthetic taste dominated by plainness.Chinese national aesthetic tastes,distinguished by implicitness,symbolism,and ethereality,have the magical power to present charming conceptions via plain and simple scenes,thus endowing the“People’s Films”with natural,plain,and harmonious frames that are unique to China.Behind the silent and plain scenes are representations of personal cultivation and essential values cherished by the Chinese people,which are achieved via the momentary presence and entirety of scenes photographed in the films,delivering an internal transcendence of people’s consciousness.展开更多
Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investig...Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investigative procedure and obtain results makes it the first imaging modality used to unravel the different causes of acute abdominal conditions in children. The safety of abdominal x-ray in children makes it attractive for use in paediatric surgical practice as part of routine work-up for undifferentiated acute abdominal conditions and also to diagnose specific causes of acute abdomen in children. Setting: Olabisi Onabanjo University Teaching Hospital, Sagamu, Ogun State. Objectives: Evaluation of the role of plain abdominal x-ray in diagnosing common acute abdominal conditions in children. Materials and method: Patients admitted to the children emergency room, paediatric surgical wards, children’s ward and neonatal ward who had plain abdominal x-ray as part of their diagnostic work-up were included in the study. They were studied prospectively between March 2011 and April 2021. Results: Three Hundred and Ninety-nine patients who had plain abdominal x-rays as part of their diagnostic work-up were studied. Males were 240 while females were 159, a male to female ratio of 1.5:1. The patients were aged between 1 day to 16 years. Differential diagnoses made with plain abdominal x-ray were intestinal obstruction in 298, perforated viscus 69 patients, intra-abdominal masses 13 patients and location of intra-abdominal foreign body 14. Intestinal obstruction cases in which plain abdominal x-ray played a role in their diagnosis and management included the following: intussusception 66, neonatal sepsis 60, malrotation 48, intestinal atresia 42, anorectal malformation 32, hirschsprung’s disease in 30 cases, pyloric stenosis 24, obstructed hernia 22, post-operative adhesions 16 and intestinal helminthiasis 12. Perforated viscus accounted for 69 indications. Out of these indications, perforated gut in intussusception 19, perforated typhoid ileitis was responsible in 13 cases, gut perforation in blunt abdominal trauma 8, perforation in strangulated hernia 11 cases, perforated gut in malrotation 7, ceacal perforation in hirschsprugs disease 6 and colonic perforation in necrotizing enterocolitis 5 cases. Conclusion: Plain abdominal x-ray remains a role to play in the differential diagnosis and management of common paediatric acute abdominal conditions.展开更多
This study reports the dosimetric response of a(ZnO)_(0.2)(TeO_(2))_(0.8)thin film sensor irradiated with high-energy X-ray radiation at various doses.The spray pyrolysis method was used for the film deposition on sod...This study reports the dosimetric response of a(ZnO)_(0.2)(TeO_(2))_(0.8)thin film sensor irradiated with high-energy X-ray radiation at various doses.The spray pyrolysis method was used for the film deposition on soda-lime glass substrate using zinc acetate dehydrate and tellurium dioxide powder as the starting precursors.The structural and morphological properties of the film were determined.The I-V characteristics measurements were performed during irradiation with a 6 MV X-ray beam from a Linac.The results revealed that the XRD pattern of the AS-deposited thin film is non-crystalline(amorphous)in nature.The FESEM image shows the non-uniform shape of nanoparticles agglomerated separately,and the EDX spectrum shows the presence of Te,Zn,and O in the film.The I-V characteristics measurements indicate that the current density increases linearly with X-ray doses(0-250 cGy)for all applied voltages(1-6 V).The sensitivity of the thin film sensor has been found to be in the range of 0.37-0.94 mA/cm^(2)/Gy.The current-voltage measurement test for fading normalised in percentage to day 0 was found in the order of day 0>day 15>day 30>day 1>day 2.These results are expected to be beneficial for fabricating cheap and practical X-ray sensors.展开更多
The amorphous phase-change materials with spontaneous structural relaxation leads to the resistance drift with the time for phase-change neuron synaptic devices. Here, we modify the phase change properties of the conv...The amorphous phase-change materials with spontaneous structural relaxation leads to the resistance drift with the time for phase-change neuron synaptic devices. Here, we modify the phase change properties of the conventional Ge_2Sb_2Te_5(GST) material by introducing an SnS phase. It is found that the resistance drift coefficient of SnS-doped GST was decreased from 0.06 to 0.01. It can be proposed that the origin originates from the precipitation of GST nanocrystals accompanied by the precipitation of SnS crystals compared to single-phase GST compound systems. We also found that the decrease in resistance drift can be attributed to the narrowed bandgap from 0.65 to 0.43 eV after SnS-doping. Thus, this study reveals the quantitative relationship between the resistance drift and the band gap and proposes a new idea for alleviating the resistance drift by composition optimization, which is of great significance for finding a promising phase change material.展开更多
The effect of silicon doping on the residual stress of CVD diamond films is examined using both X-ray diffraction (XRD) analysis and Raman spectroscopy measurements. The examined Si-doped diamond films are deposited o...The effect of silicon doping on the residual stress of CVD diamond films is examined using both X-ray diffraction (XRD) analysis and Raman spectroscopy measurements. The examined Si-doped diamond films are deposited on WC-Co substrates in a home-made bias-enhanced HFCVD apparatus. Ethyl silicate (Si(OC2H5)4) is dissolved in acetone to obtain various Si/C mole ratio ranging from 0.1% to 1.4% in the reaction gas. Characterizations with SEM and XRD indicate increasing silicon concentration may result in grain size decreasing and diamond [110] texture becoming dominant. The residual stress values of as-deposited Si-doped diamond films are evaluated by both sin2ψ method, which measures the (220) diamond Bragg diffraction peaks using XRD, with ψ-values ranging from 0° to 45°, and Raman spectroscopy, which detects the diamond Raman peak shift from the natural diamond line at 1332 cm-1. The residual stress evolution on the silicon doping level estimated from the above two methods presents rather good agreements, exhibiting that all deposited Si-doped diamond films present compressive stress and the sample with Si/C mole ratio of 0.1% possesses the largest residual stress of ~1.75 GPa (Raman) or ~2.3 GPa (XRD). As the silicon doping level is up further, the residual stress reduces to a relative stable value around 1.3 GPa.展开更多
To identify a strategy for earlier sowing and harvesting of spring maize(Zea mays L.) in an alternative maize–maize double cropping system, a 2-year field experiment was performed at Quzhou experimental station of Ch...To identify a strategy for earlier sowing and harvesting of spring maize(Zea mays L.) in an alternative maize–maize double cropping system, a 2-year field experiment was performed at Quzhou experimental station of China Agricultural University in 2014 and 2015. A short-season cultivar, Demeiya number 1(KX7349), was used in the experiment. Soil temperature to 5 cm depth in the early crop growth stage, crop growth, crop yield, and water use of different treatments(plastic film-mulched raised bed(RF) and flat field without plastic film mulching(CK) in 2014; RF, plastic film-mulched flat field(FF), and CK in 2015)were measured or calculated and compared. Soil temperature in the film-mulched treatments was consistently higher than that in CK(1.6–3.5 °C in average) during the early growth stage. Crops in plastic film-mulched treatments used 214 fewer growing-degree days(GDDs) in 2014 and 262 fewer GDDs in 2015. In 2014, the RF treatment yielded 32.7%higher biomass than CK, although its 9.4% higher grain yield was not statistically significant. Also, RF used 17.9% less water and showed 33.1% higher water use efficiency(WUE) than CK. In 2015, RF and FF showed 56.2% and 49.5% higher yield, 15.0% and 4.5%lower water use(ET), and 63.4% and 75.7% higher WUE, respectively, than CK. RF markedly increased soil temperature in the early crop season, accelerated crop growth, reduced ET,and greatly increased crop yield and WUE. Compared with FF, RF had no obvious effect on crop growth rate, although soil temperature during the period between sowing and stem elongation was slightly increased. However, RF resulted in lower ET and higher WUE than FF. Effects of RF on soil water dynamics as well as its cost-effectiveness remain topics for further study.展开更多
This paper reports how pyrite films were prepared by thermal sulfurization of magnetron sputtered iron films and characterized by X-ray absorption near edge structure spectra and X-ray photoelectron spectroscopy on a ...This paper reports how pyrite films were prepared by thermal sulfurization of magnetron sputtered iron films and characterized by X-ray absorption near edge structure spectra and X-ray photoelectron spectroscopy on a 4B9B beam line at the Beijing Synchrotron Radiation Facility. The band gap of the pyrite agrees well with the optical band gap obtained by a spectrophotometer. The octahedral symmetry of pyrite leads to the splitting of the d orbit into t2g and eg levels. The high spin and low spin states were analysed through the difference of electron exchange interaction and the orbital crystal field. Only when the crystal field splitting is higher than 1.5 eV, the two weak peaks above the white lines can appear, and this was approved by experiments in the present work.展开更多
TixAl1-xN films have been prepared by RF reactive magnetron sputtering. X-ray diffraction results showed that TixAl1-xN thin films in this study were hexagonal wurtzite structure with the Ti content up to 0.18. X-ray ...TixAl1-xN films have been prepared by RF reactive magnetron sputtering. X-ray diffraction results showed that TixAl1-xN thin films in this study were hexagonal wurtzite structure with the Ti content up to 0.18. X-ray photoelectron spectrocopy studies provided that the Nls core-electron spectrum of TixAl1-xN thin film brodend with increasing Ti content, and the difference of the chemical shifts for Ti2p3/2 line between TiN and TixAl1-xN th77pj in film was 0.7 eV.展开更多
A diamond film with a size of 6×6×0.5 mm^3 is fabricated by electron-assisted chemical vapor deposition. Raman spectrum analysis, x-ray diffraction and scanning electron microscope images confirm the high pu...A diamond film with a size of 6×6×0.5 mm^3 is fabricated by electron-assisted chemical vapor deposition. Raman spectrum analysis, x-ray diffraction and scanning electron microscope images confirm the high purity and large grain size, which is larger than 300 μm. Its resistivity is higher than 10^12 W· cm. Interlaced-finger electrodes are imprinted onto the diamond film to develop an x-ray detector. Ohmic contact is confirmed by checking the linearity of its current–voltage curve. The dark current is lower than 0.1 n A under an electric field of 30 k V cm^-1. The time response is 220 ps. The sensitivity is about 125 m A W^-1 under a biasing voltage of 100 V.A good linear radiation dose rate is also confirmed. This diamond detector is used to measure x-ray on a Z-pinch, which has a double-layer 'nested tungsten wire array'. The pronounced peaks in the measured waveform clearly characterize the x-ray bursts, which proves the performance of this diamond detector.展开更多
Glancing Angle X-ray Diffraction (GAXRD) is introduced as a direct, non-destructive, surface-sensitive technique for analysis of thin films. The method was applied to polycrystalline thin films (namely, titanium oxide...Glancing Angle X-ray Diffraction (GAXRD) is introduced as a direct, non-destructive, surface-sensitive technique for analysis of thin films. The method was applied to polycrystalline thin films (namely, titanium oxide, zinc selenide, cadmium selenide and combinations thereof) obtained by electrochemical growth, in order to determine the composition of ultra-thin surface layers, to estimate film thickness, and perform depth profiling of multilayered heterostructures. The experimental data are treated on the basis of a simple absorption-diffraction model involving the glancing angle of X-ray incidence.展开更多
Colonic volvulus is a relatively uncommon cause of large bowel obstruction usually involving mobile,intraperitoneal,colonic segments.Congenital or acquired anatomic variation may be associated with an increased risk o...Colonic volvulus is a relatively uncommon cause of large bowel obstruction usually involving mobile,intraperitoneal,colonic segments.Congenital or acquired anatomic variation may be associated with an increased risk of colonic volvulus which can occasionally involve retro-peritoneal segments.We report a case of 54-year-old female who presented to our Institution to perform a plain abdominal film series for acute onset of cramping abdominal pain.Both the upright and supine films showed signs of acute colonic obstruction which was thought to be due to an internal hernia of the transverse colon into the lesser sac.The patient was therefore submitted to a multi-detector contrast-enhanced computed tomography(CT).CT findings were initially thought to be consistent with the presumed diagnosis of internal hernia but further evaluation and coronal reformatting clearly depicted the presence of a colonic volvulus possibly resulting from a retro-gastric colon.At surgery,a volvulus of the ascending colon was found and a right hemi-colectomy had to be performed.However,a non rotated midgut with a right-sided duodeno-jejunal flexure and a left sided colon was also found at laparotomy and over-looked in the pre-operative CT.Retrospective evaluation of CT images was therefore performed and a number of CT signs of intestinal malrotation could be identified.展开更多
Equation(6)in Chin.Phys.090833(2000)is corrected.All subsequent derivations were given based on the correct Eq.(6),so the conclusions in the paper are not ffected by the rrata.
X-ray diffraction is used extensively to determine the residual stress in bulk or thin film materials on the as- sumptions that the material is composed of fine crystals with random orientation and the stress state is...X-ray diffraction is used extensively to determine the residual stress in bulk or thin film materials on the as- sumptions that the material is composed of fine crystals with random orientation and the stress state is biaxial and homogeneous through the x-ray penetrating region. The stress is calculated from the gradient of ε ~ sin^2 φ linear relation. But the method cannot be used in textured films due to nonlinear relation. In this paper, a novel method is proposed for measuring the multiaxial stresses in cubic films with any [hkl] fibre texture. As an example, a detailed analysis is given for measuring three-dimensional stresses in FCC films with [111] fibre texture.展开更多
TiN films deposited by the VCAD method at the substrate of stainless steel and superhigh speed tool steels are uniform and dense.Their colour,orientation and lattice parameter depend on deposited condition The lattice...TiN films deposited by the VCAD method at the substrate of stainless steel and superhigh speed tool steels are uniform and dense.Their colour,orientation and lattice parameter depend on deposited condition The lattice structure of deposited film,the change of the lattice parameter and its preferred orientation were studied by the XRD method,different behaviours of TiNx film were analysed.The lattice parameter of TiNx films is increased with the nitrogen content and The colour of TiNx film is strongly related to the content of Nitrogen also.The change of preferred orientation depends mainly on the Bias.展开更多
The computer evaluation of weld X-ray film is an attractive technique for weld seam NDT ( nondestructive testing). To achieve this target, digitalization of film is the first step and automatic defect identification...The computer evaluation of weld X-ray film is an attractive technique for weld seam NDT ( nondestructive testing). To achieve this target, digitalization of film is the first step and automatic defect identification is another key technique. In this paper, a weld X-ray film digitalizing system has been established with linear array CCD and highlight LED light source. Its space resolution can reach 0. 04 mm/pixel and scanning speed can reach 100 mm/s for an industrial film. The transfer function curves of the system have been measured and the results indicate that its image gray resolution can reach 88 G/D at 4. 5D, and its dynamic range can be wider than 2. OD. In order to facilitate the evaluation of large welded structure, a panoramic evaluation algorithm is developed also. The algorithm includes image matching, image fusion and panoramic evaluation of the long linked film image.展开更多
Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic...Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic performance of the detector for a range of energies relevant to diagnostic imaging applications, such as fluoroscopy. The input x-ray spectra for a set of tube potentials ranging from 70 to 140 kVp were computed with the tungsten anode spectral model using interpolating polynomials (TASMIP) based on the measured output of our diagnostic x-ray simulator. Frequency-dependent detector performance analysis was conducted through Monte Carlo simulations of energy deposition within the detector. Intrinsic modulation transfer functions (MTF), noise power spectra (NPS), and detective quantum efficiencies (DQE) were computed for a set of CdTe detectors of varying thickness, from 100 to 1000 μm. MTF behavior at higher frequencies was affected by thickness and input energy, NPS increased with film thickness and energy, and the resultant DQE(f) decreased with increasing the input energy, but increased with the thickness of the detector. We found that the optimal thickness of CdTe under diagnostic x-ray beam is in the range of 300 to 600 μm. Physical properties of CdTe, such as the high atomic number and density, used in direct detection configuration, together with the recently established thin-film manufacturing techniques makes this technology a promising photoconductor for large area diagnostic flat panel imaging.展开更多
Chemically synthesized ZnS thin film is found to be a good x-ray radiation sensor. We report the effect of annealing on the x-ray radiation detection sensitivity of a ZnS thin film synthesized by a chemical bath depos...Chemically synthesized ZnS thin film is found to be a good x-ray radiation sensor. We report the effect of annealing on the x-ray radiation detection sensitivity of a ZnS thin film synthesized by a chemical bath deposition technique. The chemically synthesized ZnS films are annealed at 333, 363 and 393K for 1 h. Structural analyses show that the lattice defects in the films decrease with annealing. Further, the band gap is also found to decrease from 3.38 to 3.21 eV after annealing at 393K. Current-voltage characteristics of the films are studied under dark and x-ray irradiation conditions. Due to the decrease of lattice defects and band gap, the conductivity under dark conditions is found to increase from 2.06 × 10^-6 to 1.69 × 10^-5 S/em, while that under x-ray irradiation increases from 4.13 × 10^-5 to 5.28 ×10^-5 S/cm. On the other hand, the x-ray radiation detection sensitivity of the films is found to decrease with annealing. This decrease of detection sensitivity is attributed to the decrease of the band gap as well as some structural and surface morphological changes occurring after annealing.展开更多
Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this in...Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this instrumental setup to analyze a Si single crystal and a 50 nm HfO_(2) single-layer film deposited on a Si substrate.展开更多
基金supported by the project“PARIDE”(Perovskite Advanced Radiotherapy&Imaging Detectors),funded under the Regional Research and Innovation Programme POR-FESR Lazio 2014-2020(project number:A0375-2020-36698).
文摘Metal-halide perovskites are revolutionizing the world of X-ray detectors,due to the development of sensitive,fast,and cost-effective devices.Self-powered operation,ensuring portability and low power consumption,has also been recently demonstrated in both bulk materials and thin films.However,the signal stability and repeatability under continuous X-ray exposure has only been tested up to a few hours,often reporting degradation of the detection performance.Here it is shown that self-powered direct X-ray detectors,fabricated starting from a FAPbBr_(3)submicrometer-thick film deposition onto a mesoporous TiO_(2)scaffold,can withstand a 26-day uninterrupted X-ray exposure with negligible signal loss,demonstrating ultra-high operational stability and excellent repeatability.No structural modification is observed after irradiation with a total ionizing dose of almost 200 Gy,revealing an unexpectedly high radiation hardness for a metal-halide perovskite thin film.In addition,trap-assisted photoconductive gain enabled the device to achieve a record bulk sensitivity of 7.28 C Gy^(−1)cm^(−3)at 0 V,an unprecedented value in the field of thin-film-based photoconductors and photodiodes for“hard”X-rays.Finally,prototypal validation under the X-ray beam produced by a medical linear accelerator for cancer treatment is also introduced.
基金the financially support of the National Natural Science Foundation of China(12164051)the Joint Foundation of Provincial Science and Technology Department-Double First-class Construction of Yunnan University(2019FY003016)+4 种基金the Young Top Talent Project of Yunnan Province(YNWR-QNBJ-2018-229)the financially support by Yunnan Major Scientific and Technological Projects(202202AG050016)Advanced Analysis and Measurement Center of Yunnan University for the sample characterization service and the Postgraduate Research and Innovation Foundation of Yunnan University(2021Y036)the financially support of the National Natural Science Foundation of China(62064013)the Application Basic Research Project of Yunnan Province[2019FB130]。
文摘Low-dimensional halide perovskites have become the most promising candidates for X-ray imaging,yet the issues of the poor chemical stability of hybrid halide perovskite,the high poisonousness of lead halides and the relatively low detectivity of the lead-free halide perovskites which seriously restrain its commercialization.Here,we developed a solution inverse temperature crystal growth(ITCG)method to bring-up high quality Cs_(3)Cu_(2)I_(5)crystals with large size of centimeter order,in which the oleic acid(OA)is introduced as an antioxidative ligand to inhibit the oxidation of cuprous ions effieiently,as well as to decelerate the crystallization rate remarkalby.Based on these fine crystals,the vapor deposition technique is empolyed to prepare high quality Cs_(3)Cu_(2)I_(5)films for efficient X-ray imaging.Smooth surface morphology,high light yields and short decay time endow the Cs_(3)Cu_(2)I_(5)films with strong radioluminescence,high resolution(12 lp/mm),low detection limits(53 nGyair/s)and desirable stability.Subsequently,the Cs_(3)Cu_(2)I_(5)films have been applied to the practical radiography which exhibit superior X-ray imaging performance.Our work provides a paradigm to fabricate nonpoisonous and chemically stable inorganic halide perovskite for X-ray imaging.
基金the 2020 National Social Science Fund Art Project“History of Chinese Film Thought(1905-1949)”(Project No.:20BC035).
文摘The“People’s Films,”when examined from the perspective of classical aesthetics,present a unique visual style that creates artistic conceptions through sparse filming and deliver a scenery-based ideology through background shots,contributing to the overall aesthetic taste dominated by plainness.Chinese national aesthetic tastes,distinguished by implicitness,symbolism,and ethereality,have the magical power to present charming conceptions via plain and simple scenes,thus endowing the“People’s Films”with natural,plain,and harmonious frames that are unique to China.Behind the silent and plain scenes are representations of personal cultivation and essential values cherished by the Chinese people,which are achieved via the momentary presence and entirety of scenes photographed in the films,delivering an internal transcendence of people’s consciousness.
文摘Background: The plain abdominal x-ray is one of the commonly requested investigations in the children emergency room, paediatric surgical ward and neonatal wards. The short interval required to carry out this investigative procedure and obtain results makes it the first imaging modality used to unravel the different causes of acute abdominal conditions in children. The safety of abdominal x-ray in children makes it attractive for use in paediatric surgical practice as part of routine work-up for undifferentiated acute abdominal conditions and also to diagnose specific causes of acute abdomen in children. Setting: Olabisi Onabanjo University Teaching Hospital, Sagamu, Ogun State. Objectives: Evaluation of the role of plain abdominal x-ray in diagnosing common acute abdominal conditions in children. Materials and method: Patients admitted to the children emergency room, paediatric surgical wards, children’s ward and neonatal ward who had plain abdominal x-ray as part of their diagnostic work-up were included in the study. They were studied prospectively between March 2011 and April 2021. Results: Three Hundred and Ninety-nine patients who had plain abdominal x-rays as part of their diagnostic work-up were studied. Males were 240 while females were 159, a male to female ratio of 1.5:1. The patients were aged between 1 day to 16 years. Differential diagnoses made with plain abdominal x-ray were intestinal obstruction in 298, perforated viscus 69 patients, intra-abdominal masses 13 patients and location of intra-abdominal foreign body 14. Intestinal obstruction cases in which plain abdominal x-ray played a role in their diagnosis and management included the following: intussusception 66, neonatal sepsis 60, malrotation 48, intestinal atresia 42, anorectal malformation 32, hirschsprung’s disease in 30 cases, pyloric stenosis 24, obstructed hernia 22, post-operative adhesions 16 and intestinal helminthiasis 12. Perforated viscus accounted for 69 indications. Out of these indications, perforated gut in intussusception 19, perforated typhoid ileitis was responsible in 13 cases, gut perforation in blunt abdominal trauma 8, perforation in strangulated hernia 11 cases, perforated gut in malrotation 7, ceacal perforation in hirschsprugs disease 6 and colonic perforation in necrotizing enterocolitis 5 cases. Conclusion: Plain abdominal x-ray remains a role to play in the differential diagnosis and management of common paediatric acute abdominal conditions.
文摘This study reports the dosimetric response of a(ZnO)_(0.2)(TeO_(2))_(0.8)thin film sensor irradiated with high-energy X-ray radiation at various doses.The spray pyrolysis method was used for the film deposition on soda-lime glass substrate using zinc acetate dehydrate and tellurium dioxide powder as the starting precursors.The structural and morphological properties of the film were determined.The I-V characteristics measurements were performed during irradiation with a 6 MV X-ray beam from a Linac.The results revealed that the XRD pattern of the AS-deposited thin film is non-crystalline(amorphous)in nature.The FESEM image shows the non-uniform shape of nanoparticles agglomerated separately,and the EDX spectrum shows the presence of Te,Zn,and O in the film.The I-V characteristics measurements indicate that the current density increases linearly with X-ray doses(0-250 cGy)for all applied voltages(1-6 V).The sensitivity of the thin film sensor has been found to be in the range of 0.37-0.94 mA/cm^(2)/Gy.The current-voltage measurement test for fading normalised in percentage to day 0 was found in the order of day 0>day 15>day 30>day 1>day 2.These results are expected to be beneficial for fabricating cheap and practical X-ray sensors.
基金financially supported by the National Natural Science Foundation of China(Grant No.62074089)the Natural Science Foundation of Ningbo City,China(Grant No.2022J072)+1 种基金the Youth Science and Technology Innovation Leading Talent Project of Ningbo City,China(Grant No.2023QL005)sponsored by the K.C.Wong Magna Fund in Ningbo University。
文摘The amorphous phase-change materials with spontaneous structural relaxation leads to the resistance drift with the time for phase-change neuron synaptic devices. Here, we modify the phase change properties of the conventional Ge_2Sb_2Te_5(GST) material by introducing an SnS phase. It is found that the resistance drift coefficient of SnS-doped GST was decreased from 0.06 to 0.01. It can be proposed that the origin originates from the precipitation of GST nanocrystals accompanied by the precipitation of SnS crystals compared to single-phase GST compound systems. We also found that the decrease in resistance drift can be attributed to the narrowed bandgap from 0.65 to 0.43 eV after SnS-doping. Thus, this study reveals the quantitative relationship between the resistance drift and the band gap and proposes a new idea for alleviating the resistance drift by composition optimization, which is of great significance for finding a promising phase change material.
基金Project (51005154) supported by the National Natural Science Foundation of ChinaProject (12CG11) supported by the Chenguang Program of Shanghai Municipal Education Commission, ChinaProject (201104271) supported by the China Postdoctoral Science Foundation
文摘The effect of silicon doping on the residual stress of CVD diamond films is examined using both X-ray diffraction (XRD) analysis and Raman spectroscopy measurements. The examined Si-doped diamond films are deposited on WC-Co substrates in a home-made bias-enhanced HFCVD apparatus. Ethyl silicate (Si(OC2H5)4) is dissolved in acetone to obtain various Si/C mole ratio ranging from 0.1% to 1.4% in the reaction gas. Characterizations with SEM and XRD indicate increasing silicon concentration may result in grain size decreasing and diamond [110] texture becoming dominant. The residual stress values of as-deposited Si-doped diamond films are evaluated by both sin2ψ method, which measures the (220) diamond Bragg diffraction peaks using XRD, with ψ-values ranging from 0° to 45°, and Raman spectroscopy, which detects the diamond Raman peak shift from the natural diamond line at 1332 cm-1. The residual stress evolution on the silicon doping level estimated from the above two methods presents rather good agreements, exhibiting that all deposited Si-doped diamond films present compressive stress and the sample with Si/C mole ratio of 0.1% possesses the largest residual stress of ~1.75 GPa (Raman) or ~2.3 GPa (XRD). As the silicon doping level is up further, the residual stress reduces to a relative stable value around 1.3 GPa.
基金financially supported by the Special Fund for Agro-scientific Research in the Public Interest (No. 201103001)
文摘To identify a strategy for earlier sowing and harvesting of spring maize(Zea mays L.) in an alternative maize–maize double cropping system, a 2-year field experiment was performed at Quzhou experimental station of China Agricultural University in 2014 and 2015. A short-season cultivar, Demeiya number 1(KX7349), was used in the experiment. Soil temperature to 5 cm depth in the early crop growth stage, crop growth, crop yield, and water use of different treatments(plastic film-mulched raised bed(RF) and flat field without plastic film mulching(CK) in 2014; RF, plastic film-mulched flat field(FF), and CK in 2015)were measured or calculated and compared. Soil temperature in the film-mulched treatments was consistently higher than that in CK(1.6–3.5 °C in average) during the early growth stage. Crops in plastic film-mulched treatments used 214 fewer growing-degree days(GDDs) in 2014 and 262 fewer GDDs in 2015. In 2014, the RF treatment yielded 32.7%higher biomass than CK, although its 9.4% higher grain yield was not statistically significant. Also, RF used 17.9% less water and showed 33.1% higher water use efficiency(WUE) than CK. In 2015, RF and FF showed 56.2% and 49.5% higher yield, 15.0% and 4.5%lower water use(ET), and 63.4% and 75.7% higher WUE, respectively, than CK. RF markedly increased soil temperature in the early crop season, accelerated crop growth, reduced ET,and greatly increased crop yield and WUE. Compared with FF, RF had no obvious effect on crop growth rate, although soil temperature during the period between sowing and stem elongation was slightly increased. However, RF resulted in lower ET and higher WUE than FF. Effects of RF on soil water dynamics as well as its cost-effectiveness remain topics for further study.
基金Project supported by the National Natural Science Foundation of China (Grant No 102750770)
文摘This paper reports how pyrite films were prepared by thermal sulfurization of magnetron sputtered iron films and characterized by X-ray absorption near edge structure spectra and X-ray photoelectron spectroscopy on a 4B9B beam line at the Beijing Synchrotron Radiation Facility. The band gap of the pyrite agrees well with the optical band gap obtained by a spectrophotometer. The octahedral symmetry of pyrite leads to the splitting of the d orbit into t2g and eg levels. The high spin and low spin states were analysed through the difference of electron exchange interaction and the orbital crystal field. Only when the crystal field splitting is higher than 1.5 eV, the two weak peaks above the white lines can appear, and this was approved by experiments in the present work.
基金This work was supported by the National Natural Science Foundation of China under grant No.10474074the Hubei Natural Science Foundation under grant No.2001ABB060.
文摘TixAl1-xN films have been prepared by RF reactive magnetron sputtering. X-ray diffraction results showed that TixAl1-xN thin films in this study were hexagonal wurtzite structure with the Ti content up to 0.18. X-ray photoelectron spectrocopy studies provided that the Nls core-electron spectrum of TixAl1-xN thin film brodend with increasing Ti content, and the difference of the chemical shifts for Ti2p3/2 line between TiN and TixAl1-xN th77pj in film was 0.7 eV.
基金supported by the National Key R&D Program of China(Grant No.2017YFE0301300)the Hunan Provincial Innovation Foundation for Postgraduate(Grant No.CX2018B588)。
文摘A diamond film with a size of 6×6×0.5 mm^3 is fabricated by electron-assisted chemical vapor deposition. Raman spectrum analysis, x-ray diffraction and scanning electron microscope images confirm the high purity and large grain size, which is larger than 300 μm. Its resistivity is higher than 10^12 W· cm. Interlaced-finger electrodes are imprinted onto the diamond film to develop an x-ray detector. Ohmic contact is confirmed by checking the linearity of its current–voltage curve. The dark current is lower than 0.1 n A under an electric field of 30 k V cm^-1. The time response is 220 ps. The sensitivity is about 125 m A W^-1 under a biasing voltage of 100 V.A good linear radiation dose rate is also confirmed. This diamond detector is used to measure x-ray on a Z-pinch, which has a double-layer 'nested tungsten wire array'. The pronounced peaks in the measured waveform clearly characterize the x-ray bursts, which proves the performance of this diamond detector.
文摘Glancing Angle X-ray Diffraction (GAXRD) is introduced as a direct, non-destructive, surface-sensitive technique for analysis of thin films. The method was applied to polycrystalline thin films (namely, titanium oxide, zinc selenide, cadmium selenide and combinations thereof) obtained by electrochemical growth, in order to determine the composition of ultra-thin surface layers, to estimate film thickness, and perform depth profiling of multilayered heterostructures. The experimental data are treated on the basis of a simple absorption-diffraction model involving the glancing angle of X-ray incidence.
文摘Colonic volvulus is a relatively uncommon cause of large bowel obstruction usually involving mobile,intraperitoneal,colonic segments.Congenital or acquired anatomic variation may be associated with an increased risk of colonic volvulus which can occasionally involve retro-peritoneal segments.We report a case of 54-year-old female who presented to our Institution to perform a plain abdominal film series for acute onset of cramping abdominal pain.Both the upright and supine films showed signs of acute colonic obstruction which was thought to be due to an internal hernia of the transverse colon into the lesser sac.The patient was therefore submitted to a multi-detector contrast-enhanced computed tomography(CT).CT findings were initially thought to be consistent with the presumed diagnosis of internal hernia but further evaluation and coronal reformatting clearly depicted the presence of a colonic volvulus possibly resulting from a retro-gastric colon.At surgery,a volvulus of the ascending colon was found and a right hemi-colectomy had to be performed.However,a non rotated midgut with a right-sided duodeno-jejunal flexure and a left sided colon was also found at laparotomy and over-looked in the pre-operative CT.Retrospective evaluation of CT images was therefore performed and a number of CT signs of intestinal malrotation could be identified.
文摘Equation(6)in Chin.Phys.090833(2000)is corrected.All subsequent derivations were given based on the correct Eq.(6),so the conclusions in the paper are not ffected by the rrata.
基金Project supported by the State Key Development Program for Basic Research of China (Grant No 2004CB619302), and the National Natural Science Foundation of China (Grant No 50271038).
文摘X-ray diffraction is used extensively to determine the residual stress in bulk or thin film materials on the as- sumptions that the material is composed of fine crystals with random orientation and the stress state is biaxial and homogeneous through the x-ray penetrating region. The stress is calculated from the gradient of ε ~ sin^2 φ linear relation. But the method cannot be used in textured films due to nonlinear relation. In this paper, a novel method is proposed for measuring the multiaxial stresses in cubic films with any [hkl] fibre texture. As an example, a detailed analysis is given for measuring three-dimensional stresses in FCC films with [111] fibre texture.
文摘TiN films deposited by the VCAD method at the substrate of stainless steel and superhigh speed tool steels are uniform and dense.Their colour,orientation and lattice parameter depend on deposited condition The lattice structure of deposited film,the change of the lattice parameter and its preferred orientation were studied by the XRD method,different behaviours of TiNx film were analysed.The lattice parameter of TiNx films is increased with the nitrogen content and The colour of TiNx film is strongly related to the content of Nitrogen also.The change of preferred orientation depends mainly on the Bias.
文摘The computer evaluation of weld X-ray film is an attractive technique for weld seam NDT ( nondestructive testing). To achieve this target, digitalization of film is the first step and automatic defect identification is another key technique. In this paper, a weld X-ray film digitalizing system has been established with linear array CCD and highlight LED light source. Its space resolution can reach 0. 04 mm/pixel and scanning speed can reach 100 mm/s for an industrial film. The transfer function curves of the system have been measured and the results indicate that its image gray resolution can reach 88 G/D at 4. 5D, and its dynamic range can be wider than 2. OD. In order to facilitate the evaluation of large welded structure, a panoramic evaluation algorithm is developed also. The algorithm includes image matching, image fusion and panoramic evaluation of the long linked film image.
文摘Significant advancement in thin-film cadmium telluride (CdTe) deposition techniques in recent years has made this material attractive for the development of low-cost large area detector. Here we evaluate the intrinsic performance of the detector for a range of energies relevant to diagnostic imaging applications, such as fluoroscopy. The input x-ray spectra for a set of tube potentials ranging from 70 to 140 kVp were computed with the tungsten anode spectral model using interpolating polynomials (TASMIP) based on the measured output of our diagnostic x-ray simulator. Frequency-dependent detector performance analysis was conducted through Monte Carlo simulations of energy deposition within the detector. Intrinsic modulation transfer functions (MTF), noise power spectra (NPS), and detective quantum efficiencies (DQE) were computed for a set of CdTe detectors of varying thickness, from 100 to 1000 μm. MTF behavior at higher frequencies was affected by thickness and input energy, NPS increased with film thickness and energy, and the resultant DQE(f) decreased with increasing the input energy, but increased with the thickness of the detector. We found that the optimal thickness of CdTe under diagnostic x-ray beam is in the range of 300 to 600 μm. Physical properties of CdTe, such as the high atomic number and density, used in direct detection configuration, together with the recently established thin-film manufacturing techniques makes this technology a promising photoconductor for large area diagnostic flat panel imaging.
文摘Chemically synthesized ZnS thin film is found to be a good x-ray radiation sensor. We report the effect of annealing on the x-ray radiation detection sensitivity of a ZnS thin film synthesized by a chemical bath deposition technique. The chemically synthesized ZnS films are annealed at 333, 363 and 393K for 1 h. Structural analyses show that the lattice defects in the films decrease with annealing. Further, the band gap is also found to decrease from 3.38 to 3.21 eV after annealing at 393K. Current-voltage characteristics of the films are studied under dark and x-ray irradiation conditions. Due to the decrease of lattice defects and band gap, the conductivity under dark conditions is found to increase from 2.06 × 10^-6 to 1.69 × 10^-5 S/em, while that under x-ray irradiation increases from 4.13 × 10^-5 to 5.28 ×10^-5 S/cm. On the other hand, the x-ray radiation detection sensitivity of the films is found to decrease with annealing. This decrease of detection sensitivity is attributed to the decrease of the band gap as well as some structural and surface morphological changes occurring after annealing.
基金Project supported by the National Key Research and Development Program of China(Grant No.2021YFF0701202)the National Natural Science Foundation of China(Grant No.11875087)。
文摘Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this instrumental setup to analyze a Si single crystal and a 50 nm HfO_(2) single-layer film deposited on a Si substrate.