期刊文献+
共找到2,858篇文章
< 1 2 143 >
每页显示 20 50 100
Near-Infrared Fluorescence Imaging Contrast Agents for Clinical Research: Limitations and Alternatives
1
作者 Serigne Moussa Badiane Elhadji A. L. Bathily +1 位作者 Fawrou Seye Louis A.D. Diouf 《Open Journal of Biophysics》 2024年第1期73-77,共5页
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical... Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers. 展开更多
关键词 Fluorescence Imaging contrast agents Clinical Research
下载PDF
The impact of iodinated X-ray contrast agents on formation and toxicity of disinfection by-products in drinking water 被引量:12
2
作者 Clara H.Jeong Edward J.Machek +5 位作者 Morteza Shakeri Stephen E.Duirk Thomas A.Ternes Susan D.Richardson Elizabeth D.Wagner Michael J.Plewa 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2017年第8期173-182,共10页
The presence of iodinated X-ray contrast media(ICM) in source waters is of high concern to public health because of their potential to generate highly toxic disinfection by-products(DBPs). The objective of this st... The presence of iodinated X-ray contrast media(ICM) in source waters is of high concern to public health because of their potential to generate highly toxic disinfection by-products(DBPs). The objective of this study was to determine the impact of ICM in source waters and the type of disinfectant on the overall toxicity of DBP mixtures and to determine which ICM and reaction conditions give rise to toxic by-products. Source waters collected from Akron,OH were treated with five different ICMs, including iopamidol, iopromide, iohexol,diatrizoate and iomeprol, with or without chlorine or chloramine disinfection. The reaction product mixtures were concentrated with XAD resins and the mammalian cell cytotoxicity and genotoxicity of the reaction mixture concentrates was measured. Water containing iopamidol generated an enhanced level of mammalian cell cytotoxicity and genotoxicity after disinfection. While chlorine disinfection with iopamidol resulted in the highest cytotoxicity overall, the relative iopamidol-mediated increase in toxicity was greater when chloramine was used as the disinfectant compared with chlorine. Four other ICMs(iopromide, iohexol, diatrizoate, and iomeprol) expressed some cytotoxicity over the control without any disinfection, and induced higher cytotoxicity when chlorinated. Only iohexol enhanced genotoxicity compared to the chlorinated source water. 展开更多
关键词 Disinfection by-products Iodo-DBPs Iodinated x-ray contrast media
原文传递
Role of contrast-enhanced serial/spot abdominal X-rays in perioperative follow-up of patients undergoing abdominal surgery:An observational clinical study
3
作者 Osman Nuri Dilek Arif Atay +2 位作者 Orgun Gunes Furkan Karahan Şebnem Karasu 《World Journal of Radiology》 2023年第6期191-200,共10页
BACKGROUND Many imaging methods such as ultrasonography,computed tomography(CT),magnetic resonance imaging,and endoscopy are used to identify the problems or complications that occur in the perioperative period and to... BACKGROUND Many imaging methods such as ultrasonography,computed tomography(CT),magnetic resonance imaging,and endoscopy are used to identify the problems or complications that occur in the perioperative period and to determine the appropriate therapeutic approach.Specialists at surgical clinics and intensive care units sometimes need diagnostic procedures that can give quick results or reveal unexpected results.In particular,rapid on-site evaluation of patients followed under intensive care conditions has several advantages.AIM To determine the problems developing in patients in the perioperative period by contrast-enhanced abdominal X-ray(CE-AXR),revealing their current status or defining the effectiveness of CE-AXR.METHODS The files of the patients who underwent hepatopancreatobiliary or upper gastrointestinal surgery,whose CE-AXR film was taken,were reviewed retrospectively.Abdominal X-ray radiographs taken after ingestion of a watersoluble contrast agent(iohexol,300 mg,50 cc vial)and its application in a drain,nasogastric tube,or stent were evaluated.The contribution of the data obtained in patients who underwent CE-AXR to the diagnosis,follow-up,and treatment processes and the effectiveness of the application were investigated.RESULTS CE-AXR was applied to 131 patients in our clinic,most of whom underwent hepatopancreatobiliary or upper gastrointestinal surgery.It was determined that the data obtained from CE-AXR films taken in 98(74.8%)of the patients contributed to the diagnosis,treatment,and follow-up expectations and positively affected the clinical processes.CONCLUSION CE-AXR is a simple procedure that can be applied anywhere,especially in intensive care patients and at bedside,with a portable X-ray device.The simplicity of the procedure,less radiation exposure for the patients,less time wastage,reduction in the CT and endoscopy procedure burden and costs,quick results,rapid assessment of the situation,and enabling the monitoring of processes with repetitive procedures are important advantages.X-rays taken will be useful in terms of being a reference value during the follow-up period of the patient and determining the situation in medicolegal processes. 展开更多
关键词 Abdominal x-rays contrast medium Diagnosis COMPLICATION Leakage Radiation exposure
下载PDF
Theory and verification of moiréfringes for x-ray three-phase grating interferometer
4
作者 单雨征 葛永帅 +5 位作者 杨君 郭大育 蔡学宝 刘晓珂 侯晓文 郭金川 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期532-540,共9页
Dual-phase and three-phase grating x-ray interference is a promising new technique for grating-based x-ray differential phase contrast imaging.Dual-phase grating interferometers have been relatively completely studied... Dual-phase and three-phase grating x-ray interference is a promising new technique for grating-based x-ray differential phase contrast imaging.Dual-phase grating interferometers have been relatively completely studied and discussed.In this paper,the corresponding imaging fringe formula of the three-phase grating interferometer is provided.At the same time,the similarities and differences between the three-phase grating interferometer and the dual-phase grating interferometer are investigated and verified,and that the three-phase grating interferometer can produce large-period moiréfringes without using the analyzing grating is demonstrated experimentally.Finally,a simple method of designing three-phase grating and multi-grating imaging systems from geometric optics based on the thin-lens theory of gratings is presented.These theoretical formulas and experimental results provide optimization tools for designing three-phase grating interferometer systems. 展开更多
关键词 x-ray phase contrast phase grating moiréfringe
下载PDF
Gastrointestinal contrast-enhanced ultrasonography for diagnosis and treatment of peptic ulcer in children
5
作者 Yu-Hua Zhang Zhi-Hua Xu +1 位作者 Shuang-Shuang Ni Hong-Xia Luo 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期705-713,共9页
BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastr... BACKGROUND The detection rate of peptic ulcer in children is improving,with development of diagnostic procedures.Gastroscopy is the gold standard for the diagnosis of peptic ulcer,but it is an invasive procedure.Gastrointestinal contrast-enhanced ultrasonography(CEUS)has the advantages of being painless,noninvasive,nonradioactive,easy to use,and safe.AIM To investigate the clinical value of CEUS for diagnosis and treatment of peptic ulcer in children.METHODS We investigated 43 children with digestive tract symptoms in our hospital from January 2021 to June 2022.All children were examined by routine ultrasound,gastrointestinal CEUS,and gastroscopy.The pathological results of gastroscopy were taken as the gold standard.Routine ultrasonography was performed before gastrointestinal CEUS.Conventional ultrasound showed the thickness of the gastroduodenal wall,gastric peristalsis,and the adjacent organs and tissues around the abdominal cavity.Gastrointestinal CEUS recorded the thickness of the gastroduodenal wall;the size,location and shape of the ulcer;gastric peristalsis;and adjacent organs and tissues around the abdominal cavity.The results of routine ultrasound and gastrointestinal ultrasound were compared with those of gastroscopy to evaluate the diagnostic results and coincidence rate of routine ultrasound and gastrointestinal CEUS.All children received informed consent from their guardians for CEUS.This study was reviewed and approved by the hospital medical ethics committee.RESULTS Among the 43 children,17(15 male,2 female)were diagnosed with peptic ulcer by gastroscopy.There were 26 children with nonpeptic ulcer.There were eight cases of peptic ulcer and 35 of nonpeptic ulcer diagnosed by conventional ultrasound.The diagnostic coincidence rate of peptic ulcer in children diagnosed by conventional ultrasound was 79.1%(34/43),which was significantly different from that of gastroscopy(P=0.033).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is low.Fifteen cases of peptic ulcer and 28 of nonpeptic ulcer were diagnosed by CEUS.The diagnostic coincidence rate of peptic ulcer in children was 95.3%(41/43).There was no significant difference between CEUS and gastroscopy(P=0.655).It indicates that the coincidence rate of gastrointestinal contrast-enhanced ultrasound and gastroscope is high.CONCLUSION Gastrointestinal CEUS has a high coincidence rate in the diagnosis of peptic ulcer in children,and can be used as a preliminary examination method. 展开更多
关键词 contrast-enhanced ultrasound Peptic ulcer CHILDREN Gastrointestinal tract Abdominal pain Acoustic contrast agent
下载PDF
Nano/microparticles and ultrasound contrast agents 被引量:5
6
作者 Shu-Guang Zheng Hui-Xiong Xu Hang-Rong Chen 《World Journal of Radiology》 CAS 2013年第12期468-471,共4页
Microbubbles have been used for many years now in clinical practice as contrast agents in ultrasound imaging.Recently,their therapeutic applications have also attracted more attention.However,the short circulation tim... Microbubbles have been used for many years now in clinical practice as contrast agents in ultrasound imaging.Recently,their therapeutic applications have also attracted more attention.However,the short circulation time(minutes)and relatively large size(two to ten micrometers)of currently used commercial microbubbles do not allow effective extravasation into tumor tissue,preventing efficient tumor targeting.Fortunately,more multifunctional and theranostic nanoparticles with some special advantages over the traditional microbubbles have been widely investigated and explored for biomedical applications.The way to synthesize an ideal ultrasound contrast agent based on nanoparticles in order to achieve an expected effect on contrast imaging is a key technique.Currently a number of nanomaterials,including liposomes,polymers,micelles,dendrimers,emulsions,quantum dots,solid nanoparticles etc.,have already been applied to pre or clinical trials.Multifunctional and theranostic nanoparticles with some special advantages,such as the tumor-targeted(passive or active),multi-mode contrast agents(magnetic resonance imaging,ultrasonography or fluorescence),carrier or enhancer of drug delivery,and combined chemo or thermal therapy etc.,are rapidly gaining popularity and have shown a promising application in the field of cancer treatment.In this mini review,the trends and the advances of multifunctional and theranostic nanoparticles are briefly discussed. 展开更多
关键词 ULTRASOUND contrast agent MICROBUBBLE NANOPARTICLE Imaging NANOMATERIAL
下载PDF
Correlation study of biological characteristics of non-small cell lung cancer A549 cells after transfecting plasmid by microbubble ultrasound contrast agent 被引量:3
7
作者 Xuan-Yan Guo Man-Lu +2 位作者 Xue-Qing Chen Fan-Ding He Ang-Li 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2016年第6期564-567,共4页
Objective: To explore the role of the abnormal expression of miRNAs in the development process of non-small cell lung cancer and the feasibility of ultrasound microbubble-mediated gene therapy after transfecting antis... Objective: To explore the role of the abnormal expression of miRNAs in the development process of non-small cell lung cancer and the feasibility of ultrasound microbubble-mediated gene therapy after transfecting antisense miRNA-224 and miRNA-122 a plasmids into nonsmall cell lung cancer A549 cells. Methods: Antisense miRNA-224 and miRNA-122 a plasmids were transfected into non-small cell lung cancer A549 cells on the optimal ultrasound microbubble mediated condition. We set up a control group. The cell proliferation activity, apoptosis, invasion ability were detected by MTT assay, Annexin V-PE, Transwell invasion experiment and colony formation assay, respectively. Results: The expression of mi RNA-224 decreased and the expression of miRNA-122 a rose after the plasmids of target genes were transfected into non-small cell lung cancer A549 cells, and there were significant differences when compared with those of the control group(P<0.05). After the plasmids of target genes were transfected into A549 cells, the growth of antisense miRNA-224 and miRNA-122 a were inhibited, and the differences were significant as compared with the control group(P < 0.05). Besides, the inhibition of miRNA-122 a group was the most significant and there was statistically significant difference as compared with miRNA-224 group(t =-4.694, P = 0.009). After the plasmids of target genes were transfected into A549 cells, the proportion of apoptotic cells increased, the invasive cells were decreased and the clone ability reduced, and also there was a significant difference as compared with those of the control group(P < 0.05). What's more, the apoptotic peak appeared in miRNA-122 a group. Its invasion ability decreased most obviously(40.25 ± 3.97/visual field), the number of clone ability was 104.93 ± 4.87 and the inhibitory effect was the most obviously. There was statistically significant difference as compared with other groups(P < 0.05). Conclusions: A549 cells transfected by ultrasound microbubble-mediated antisense miRNA-224 and mi RNA-122 a plasmids possessed good transfection efficiency. The cell growth, invasion and colony forming abilities of transfected A549 cells were suppressed, which laid a solid foundation for the gene therapy of non-small cell lung cancer. 展开更多
关键词 MICROBUBBLE ultrasound contrast agent MiR-224 MiR-122a NON-SMALL cell LUNG cancer
下载PDF
Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake 被引量:10
8
作者 Yue-ying PAN Shu-chang ZHOU +4 位作者 Yu-jin WANG Qian LI Ting-ting ZHU Chun-xia LIU Han-xiong GUAN 《Current Medical Science》 SCIE CAS 2020年第1期178-183,共6页
The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 a... The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 and heart rate(HR)<70 beats/min were randomly divided into four groups:group A(n=31,80 kVp,270 mgl/mL);group B(n=33,100 kVp,270 mgl/mL);group C(h=30,100 kVp,320 mgl/mL);group D(w=27,100 kVp,400 mgl/mL).The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group.The CT values and SD values of the aortic root(AR),subcutaneous fat,left coronary artery opening(LCA),and right coronary artery opening(RCA)were measured in all groups,the signalto-noise ratio(SNR)and contrast noise ratio(CNR)were calculated,and effective radiation dose and iodine intake were recorded.The subjective assessment for image quality was performed by two physicians using a 4-point scale.The results were compared using the one-way ANOVA and rank sum tests.The image quality of the four groups met the clinical diagnostic requirements.The CT values of AR in groups A,B,C,and D were 537.6±71.4,447.2±81.9,445.2±64.9 and 518.5±94.9 Hu,respectively,with no significant difference between group A and group D,or between group B and group C,while CT values in groups B and C were significantly lower than those in groups A and D(P<0.05).In groups A,B,C,and D,the LCA SNR values were 22.7±9.1,23.3±9.1,23.3±7.7 and 26.6±8.9,and the RCA CNR values were 26.9±9.&28.5±11.4,27.7土&8 and 32」±10.6,respectively.The AR visual scores in groups A,B,C and D were 3.8±0.2,3.9±0.3,3.9±0.3 and 4.0±0.3,respectively.There were no significant differences in SNR,CNR and visual score among the four groups(P>0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction. 展开更多
关键词 tube voltage contrast agent coronary CT angiography radiation dose iodine intake
下载PDF
A new method of detecting interferogram in differential phase-contrast imaging system based on special structured x-ray scintillator screen 被引量:6
9
作者 刘鑫 郭金川 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期193-197,共5页
An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and ... An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and difficulty of fabrication by a state of the art technique. On the basis of phase grating diffraction, a detecting model of the scintillator screen was built for analysing the phase and absorption information of objects. According to the analysis, a new method of phase retrievals based on two-images and the optimal structure of screen were presented. 展开更多
关键词 differential phase contrast x-ray scintillator screen phase retrieval
下载PDF
Self-assembled superparamagnetic nanoparticles as MRI contrast agents — A review 被引量:2
10
作者 苏红莹 吴昌强 +1 位作者 李丹阳 艾华 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第12期175-185,共11页
Recent progress of the preparation and applications of superparamagnetic iron oxide(SPIO) clusters as magnetic resonance imaging(MRI) probes is reviewed with regard to their applications in labeling and tracking c... Recent progress of the preparation and applications of superparamagnetic iron oxide(SPIO) clusters as magnetic resonance imaging(MRI) probes is reviewed with regard to their applications in labeling and tracking cells in vivo, in diagnosis of cardiovascular diseases and tumors, and in drug delivery systems. Magnetic nanoparticles(NPs), especially SPIO nanoparticles, have long been used as MRI contrast agents and as an advantageous nanoplatform for drug delivery,taking advantage of their unique magnetic properties and ability to function at the molecular and cellular levels. Due to advances in nanotechnology, various means to control SPIO NPs' size, composition, magnetization and relaxivity have been developed, as well as ways to usefully modify their surface. Recently, self-assembly of SPIO NP clusters in particulate carriers — such as polymeric micelles, vesicles, liposomes, and layer-by-layer(Lb L) capsules — have been widely studied for application as ultrasensitive MRI probes, owing to their remarkably high spin–spin(T2) relaxivity and convenience for further functionalization. 展开更多
关键词 superparamagnetic iron nanoparticles magnetic resonance imaging contrast agent SELF-ASSEMBLY
下载PDF
Contrast-enhanced ultrasound using SonoVue mixed with oral gastrointestinal contrast agent to evaluate esophageal hiatal hernia: Report of three cases and a literature review 被引量:5
11
作者 Jing-Yu Wang Yan Luo +4 位作者 Wen-Ying Wang Shi-Cheng Zheng Lian He Chun-Yan Xie Li Peng 《World Journal of Clinical Cases》 SCIE 2021年第11期2679-2687,共9页
BACKGROUND Due to a thicker abdominal wall in some patients,ultrasound artifacts from gastrointestinal gas and surrounding tissues can interfere with routine ultrasound examination,precluding its ability to display or... BACKGROUND Due to a thicker abdominal wall in some patients,ultrasound artifacts from gastrointestinal gas and surrounding tissues can interfere with routine ultrasound examination,precluding its ability to display or clearly show the structure of a hernial sac(HS)and thereby diminishing diagnostic performance for esophageal hiatal hernia(EHH).Contrast-enhanced ultrasound(CEUS)imaging using an oral agent mixture allows for clear and intuitive identification of an EHH sac and dynamic observation of esophageal reflux.CASE SUMMARY In this case series,we report three patients with clinically-suspected EHH,including two females and one male with an average age of 67.3±16.4 years.CEUS was administered with an oral agent mixture(microbubble-based SonoVue and gastrointestinal contrast agent)and identified a direct sign of supradiaphragmatic HS(containing the hyperechoic agent)and indirect signs[e.g.,widening of esophageal hiatus,hyperechoic mixture agent continuously or intermittently reflux flowing back and forth from the stomach into the supradiaphragmatic HS,and esophagus-gastric echo ring(i.e.,the“EG”ring)seen above the diaphragm].All three cases received a definitive diagnosis of EHH by esophageal manometry and gastroscopy.Two lesions resolved upon drug treatment and one required surgery.The recurrence rate in follow-up was 0%.The data from these cases suggest that the new non-invasive examination method may greatly improve the diagnosis of EHH.CONCLUSION CEUS with the oral agent mixture can facilitate clear and intuitive identification of HS and dynamic observation of esophageal reflux. 展开更多
关键词 SONOVUE Oral gastrointestinal contrast agent contrast-enhanced ultrasound GASTROINTESTINAL Hiatal hernia Case report
下载PDF
Gilbert syndrome combined with prolonged jaundice caused by contrast agent:Case report 被引量:1
12
作者 Jian-Dan Qian Feng-Qin Hou +2 位作者 Tai-Ling Wang Chen Shao Gui-Qiang Wang 《World Journal of Gastroenterology》 SCIE CAS 2018年第13期1486-1490,共5页
This case highlights a patient with Gilbert syndrome who underwent endoscopic retrograde cholangiopancreatography(ERCP) with removal of bile duct stones, who then experienced an unexplained increase in bilirubin, with... This case highlights a patient with Gilbert syndrome who underwent endoscopic retrograde cholangiopancreatography(ERCP) with removal of bile duct stones, who then experienced an unexplained increase in bilirubin, with total bilirubin(TBIL) levels increasing from 159.5 μmol/L to 396.2 μmol/L and to a maximum of 502.8 μmol/L after 9 d. Following the decrease in the TBIL level, enhanced magnetic resonance cholangiopancreatography(MRCP) was performed to exclude any possible remaining choledocholithiasis. Nevertheless, the serum bilirubin level increased again, with TBIL levels rising from 455.7 μmol/L to 594.8 μmol/L and a maximum level of 660.3 μmol/L with no remaining bile duct stones. A liver biopsy showed severe bile duct cholestasis with no inflammation. Based on the exclusion of other potential causes of hyperbilirubinemia and the fact that both instances of increased bilirubin occurred after ERCP and MRCP, the contrast agents iopromide and gadoterate meglumine were suspected to be the causes of the hyperbilirubinemia. As of the writing of this report, the patient's bilirubin levels have spontaneously returned to baseline levels. In summary,ERCP and MRCP utilizing the contrast agents iopromide and gadoterate meglumine may possibly induce prolonged hyperbilirubinemia. 展开更多
关键词 contrast agent IOPROMIDE Gadoterate MEGLUMINE Gilbert SYNDROME JAUNDICE
下载PDF
Oleic Acid (OA), A Potential Dual Contrast Agent for Postmortem MR Angiography (PMMRA): A Pilot Study 被引量:3
13
作者 Zhi-yuan XIA Christine BRUGUIER +3 位作者 Fabrice DEDOUIT Silke GRABHERR Marc AUGSBURGER Bei-bei LIU 《Current Medical Science》 SCIE CAS 2020年第4期786-794,共9页
Summary:Choosing proper perfusates as contrast agents is an important aspect for postmortem magnetic resonance angiography(PMMRA).However,in this emerging field,the number of suitable kinds of liquid is still very lim... Summary:Choosing proper perfusates as contrast agents is an important aspect for postmortem magnetic resonance angiography(PMMRA).However,in this emerging field,the number of suitable kinds of liquid is still very limited.The objective of this research is to compare MR images of oleic acid(OA)with paraffin oil(PO)in vitro and in ex situ animal hearts,in order to evaluate the feasibility to use OA as a novel contrast agent for PMMRA.In vitro,OA,PO and water(control)were introduced into three tubes separately and T,weighted-spin echo(Tw SE)and T2w-SE images were acquired on a 1.5T MR scanner.In the second experiment,0A and PO were injected into left coronary artery(LCA)and left ventricle(LV)of ex situ bovine hearts and their Tw-SE,Tzw-SE,Tw-multipoint Dixon(Tjw-mDixon)and 3DT2w-mDixon images were acquired.The overall results indicate that OA may have a potential to be used as a dual(T and T2 based)contrast agent for PMMRA when proper sequence parameters are utilized.However,as the pilot study was based on limited number of animal hearts,more researches using OA in cadavers are needed to validate our findings. 展开更多
关键词 postmortem magnetic resonance angiography perfusate contrast agent oleic acid paraffin oil HEART
下载PDF
Optimized energy thresholds in a spectral computed tomography scan for contrast agent imaging 被引量:1
14
作者 Kai-Xin Huang Zhi Deng +1 位作者 Xiao-Fei Xu Yu-Xiang Xing 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期15-27,共13页
Spectral computed tomography(CT) based on photon counting detectors(PCDs) is a well-researched topic in the field of X-ray imaging. When PCD is applied in a spectral CT system, the PCD energy thresholds must be carefu... Spectral computed tomography(CT) based on photon counting detectors(PCDs) is a well-researched topic in the field of X-ray imaging. When PCD is applied in a spectral CT system, the PCD energy thresholds must be carefully selected, especially for K-edge imaging, which is an important spectral CT application. This paper presents a threshold selection method that yields better-quality images in K-edge imaging. The main idea is to optimize the energy thresholds ray-by-ray according to the targeted component coefficients, followed by obtaining an overall optimal energy threshold by frequency voting. A low-dose pre-scan is used in practical implementations to estimate the line integrals of the component coefficients for the basis functions. The variance of the decomposed component coefficients is then minimized using the Cramer–Rao lower bound method with respect to the energy thresholds. The optimal energy thresholds are then used to take a full scan and gain better image reconstruction with less noise than would be given by a full scan using the non-optimal energy thresholds. Simulations and practical experiments on imaging iodine and gadolinium solutions, which are commonly used as contrast agents in medical applications, were used to validate the method. The noise was significantly reduced with the same dose relative to the non-optimal energy thresholds in both simulations and in practical experiments. 展开更多
关键词 SPECTRAL CT contrast agent IMAGING Cramer-Rao LOWER BOUND Thresholds optimization Kedge
下载PDF
Photoacoustic molecular imaging using combined acupuncture and gold nanorods as a composite contrast agent 被引量:2
15
作者 Dan Wu Xinxin Zhang +1 位作者 Jian Rong Huabei Jiang 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2019年第3期41-54,共14页
In this study,we developed a novel photoacoustic imaging technique based on poly(ethyleneglycol)-coated(PEGylated)gold nanorods(PEG-GNRs)(as the contrast agent)combined with traditional Chinese medicine(TCM)acupunctur... In this study,we developed a novel photoacoustic imaging technique based on poly(ethyleneglycol)-coated(PEGylated)gold nanorods(PEG-GNRs)(as the contrast agent)combined with traditional Chinese medicine(TCM)acupuncture(as the auxiliary method)for quantitatively monitoring contrast enhancement in the vasculature of a mouse brain in vivo.This study takes advantage of the strong near-infrared absorption(peak at700 nm)of GNRs and the ability to adjust the hemodynamics of acupuncture.Experimental results show that photoacoustic tomography(PAT)successfully reveals the optical absorption variation of the vasculature of the mouse brain in response to intravenous administration of GNRs and acupuncture at the Zusanli acupoint(ST36)both individually and combined.The quantitative measurement of contrast enhancement indicates that the composite contrast agents(integration of acupuncture and GNRs)would greatly enhance the photoacoustic imaging contrast.The quantitative results also have the potential to estimate the local concentration of GNRs and even the real-time effects of acupuncture. 展开更多
关键词 Photoacoustic tomography ACUPUNCTURE contrast agent NANORODS Zusanli acupoint
下载PDF
Study on Multi-density Contrast Agent Fillers of Duct Casting Based on CT Three-Dimensional Reconstruction 被引量:5
16
作者 黄海龙 陈进军 +2 位作者 王瑜 陈小宇 龚达聪 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第2期300-306,共7页
The three-dimensional visualization model of human body duct is based on virtual anatomical structure reconstruction with duct angiography,which realizes virtual model transferred from two-dimensional,planar and stati... The three-dimensional visualization model of human body duct is based on virtual anatomical structure reconstruction with duct angiography,which realizes virtual model transferred from two-dimensional,planar and static images into three-dimensional,stereoscopic and dynamic ones repectively.In recent years,the multi-duct segmentation and division of the same specimen(or organ) is the focus of attention shared by surgeons and clinical anatomists.On the basis of 4.22 g/cm3 body bone density,this study has screened out metal oxide contract agent with different density for infusion and modeling,as well as compared and analyzed the effects of three-dimensional image of CT virtual bronchoscopy(CTVB),three-dimensional image of CT maximum intensity projection and three-dimensional model.This experiment result showed synchronously infusing multi-duct of same specimen(or organ) with contrast agent in different densities could reconstruct three-dimensional models of all ducts once only and adjust threshold to develop single or multiple ducts.It was easier to segment and observe the duct structure,anastomosis,directions and crossing in different parts,which was beyond comparison with three-dimensional image of CTVB.Although the existing three-dimensional duct reconstruction techniques still cannot be applied in living bodies temporarily,this study focused on a creative design of ducts segmentation in different density,which proposed a new experimental idea for developing multi-duct three-dimensional model in living body in the future.It will play a significant role in disease diagnosis and individual design in surgical treatment program.Therefore,this study observes the three-dimensional status of human duct with the application of contrast agent fillers in different density,combined with three-dimensional reconstruction technology.It provides an innovative idea and method for constructing three-dimensional model of digital multi-duct specimen,and the ultimate goal is to develop the digitized virtual human and precise medical treatment better and faster. 展开更多
关键词 bronchi of pig lung three-dimensional reconstruction contrast agent density difference duct casting
下载PDF
A new method for information retrieval in two-dimensional grating-based X-ray phase contrast imaging 被引量:1
17
作者 王志立 高昆 +4 位作者 陈健 葛昕 朱佩平 田扬超 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第11期547-553,共7页
Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refr... Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refraction directions. Recently, we have developed a novel reverse-projection (RP) method, which is capable of retrieving the object information efficiently with one-dimensional (1D) grating-based phase contrast imaging. In this contribution, we present its extension to the 2D grating-based X-ray phase contrast imaging, named the two-dimensional reverse- projection (2D-RP) method, for information retrieval. The method takes into account the nonlinear contributions of two refraction directions and allows the retrieval of the absorption, the horizontal and the vertical refraction images. The obtained information can be used for the reconstruction of the three-dimensionak phase gradient field, and for an improved phase map retrieval and reconstruction. Numerical experiments are carried out, and the results confirm the validity of the 2D-RP method. 展开更多
关键词 x-ray imaging phase contrast information retrieval shifting curve
下载PDF
X-ray diagnosis with a bloating agent for foreign object ingestion 被引量:1
18
作者 Hirokazu Tomishige Zenichi Morise +4 位作者 Tatsuya Suzuki Fujio Hara Masahito Hibi Takazumi Kato Takashi Hashimoto 《World Journal of Clinical Cases》 SCIE 2014年第5期157-159,共3页
The location of an ingested foreign object is often difficult to determine by X-ray if gastric air bubbles are not clear in the image.Methods that provide negative contrast can facilitate precise object localization,w... The location of an ingested foreign object is often difficult to determine by X-ray if gastric air bubbles are not clear in the image.Methods that provide negative contrast can facilitate precise object localization,which is important for object retrieval and treatment of the patient.This case report describes a male child,2 years and 2 mo of age,who accidentally swallowed a lithium battery while playing at home.A plain X-ray showed that the battery was in the abdomen,but it was unclear whether the object was still inside the stomach.A second X-ray examination performed after oral administration of a bloating agent to produce expansion of the stomach and provide negative contrast confirmed that the ingested battery was still in the stomach.The battery was then carefully removed using magnetic and balloon catheters under fluoroscopic guidance.This case report describes the successful use of an orally administered bloating agent without pain to the child in orderto determine the precise location of a foreign object in the abdomen. 展开更多
关键词 ACCIDENTAL ingestion BLOATING agent x-ray Minimal INVASION FOREIGN OBJECT
下载PDF
A contrast study on different gasifying agents of underground coal gasification at Huating Coal Mine 被引量:13
19
作者 WANG Zuo-tang HUANG Wen-gang +1 位作者 ZHANG Peng XIN Lin 《Journal of Coal Science & Engineering(China)》 2011年第2期181-186,共6页
关键词 煤炭地下气化 气化剂 华亭煤矿 两阶段气化 蒸汽分解 空气气化 氧气浓度 实验值
下载PDF
FEASIBILITY STUDY OF AN ULTRASOUND CONTRAST AGENT(LEVOVIST) IN COLOR DOPPLER IMAGING OF LIVER NEOPLASMS 被引量:6
20
作者 姜玉新 戴晴 +4 位作者 刘吉斌 张缙熙 常欣 蔡胜 谭莉 《Chinese Medical Sciences Journal》 CAS CSCD 1999年第3期167-169,共3页
INTRODUCTIONColorDopplerimaging(CDI)forthenoninvasiveassesmentofbothnormalandabnormallivervascularityhaveo... INTRODUCTIONColorDopplerimaging(CDI)forthenoninvasiveassesmentofbothnormalandabnormallivervascularityhaveoferedasignificant... 展开更多
关键词 肝脏肿瘤 彩色多普勒显像 诊断 超声波检查
下载PDF
上一页 1 2 143 下一页 到第
使用帮助 返回顶部