期刊文献+
共找到740篇文章
< 1 2 37 >
每页显示 20 50 100
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
1
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 x-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering x-ray source Monte Carlo simulation
下载PDF
Accuracy analysis of iron content of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum
2
作者 WANG Jingjing CHEN Yanfei 《Baosteel Technical Research》 CAS 2023年第4期35-40,共6页
The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectro... The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectrometry, sometimes it exceeds the quality control limit.Influences, such as current, voltage, equipment(internal circulating water, 10%CH4+90%Ar, and vacuum) checking, instrument monitoring, sample cleaning, and oper-ators, were investigated by means of 6-sigma and lean operations to improve accuracy. 展开更多
关键词 x-ray fluorescence spectrometer Lspectrum galvanized coating iron content
下载PDF
Glancing incidence x-ray fluorescence spectrometry based on a single-bounce parabolic capillary
3
作者 邵尚坤 李惠泉 +4 位作者 袁天语 孙学鹏 华路 刘志国 孙天希 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期247-250,共4页
Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this in... Glancing incidence x-ray fluorescence spectrometry using a single-bounce parabolic capillary is proposed for the analysis of layered samples.The divergence of the x-ray beam was 0.33 mrad.In this paper,we used this instrumental setup to analyze a Si single crystal and a 50 nm HfO_(2) single-layer film deposited on a Si substrate. 展开更多
关键词 single-bounce parabolic capillary glancing incident x-ray fluorescence(GIXRF) atomic layer deposition film analysis
下载PDF
Elemental composition x-ray fluorescence analysis with a TES-based high-resolution x-ray spectrometer
4
作者 吴秉骏 夏经铠 +4 位作者 张硕 傅强 章辉 谢晓明 刘志 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第9期67-73,共7页
The accurate analysis of the elemental composition plays a crucial role in the research of functional materials.The emitting characteristic x-ray fluorescence(XRF)photons can be used for precisely discriminating the s... The accurate analysis of the elemental composition plays a crucial role in the research of functional materials.The emitting characteristic x-ray fluorescence(XRF)photons can be used for precisely discriminating the specified element.The detection accuracy of conventional XRF methodology using semiconductor detector is limited by the energy resolution,thus posing a challenge in accurately scaling the actual energy of each XRF photon.We adopt a novel high-resolution x-ray spectrometer based on the superconducting transition-edge sensor(TES)for the XRF spectroscopy measurement of different elements.Properties including high energy resolution,high detection efficiency and precise linearity of the new spectrometer will bring significant benefits in analyzing elemental composition via XRF.In this paper,we study the Ledge emission line profiles of three adjacent rare earth elements with the evenly mixed sample of their oxide components:terbium,dysprosium and holmium.Two orders of magnitude better energy resolution are obtained compared to a commercial silicon drift detector.With this TES-based spectrometer,the spectral lines overlapped or interfered by background can be clearly distinguished,thus making the chemical component analysis more accurate and quantitative.A database of coefficient values for the line strength of the spectrum can then be constructed thereafter.Equipped with the novel XRF spectrometer and an established coefficient database,a direct analysis of the composition proportion of a certain element in an unknown sample can be achieved with high accuracy. 展开更多
关键词 x-ray emission spectra and fluorescence superconducting transition-edge sensor rare earth elements chemical composition analysis
下载PDF
A seven-crystal spectrometer for high-energy resolution X-ray spectroscopy at Shanghai Synchrotron Radiation Facility
5
作者 Bing-Bao Mei Liang-Xin Wang +6 位作者 Song-Qi Gu Xiao-Zhi Su Shuo Zhang Yao Wei Jing-Yuan Ma Zheng Jiang Fei Song 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期82-91,共10页
A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facili... A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facility(SSRF).This spectrometer was utilized to implement X-ray emission spectroscopy(XES),high-energy resolution fluorescence-detected X-ray absorption spectroscopy(HERFD-XAS),and resonant inelastic X-ray scattering.Seven spherically bent crystals were positioned on the respective vertical 500-mm-diameter Rowland circles,adopting an area detector to increase the solid angle to 1.75%of 4πsr,facilitating the study of low-concentrate systems under complex reaction conditions.Operated under the atmosphere pressure,the spectrometer covers the energy region from 3.5 to 18 keV,with the Bragg angle ranging from 73°to 86°during vertical scanning.It offers a promised energy resolution of sub-eV(XES)and super-eV(HERFD-XAS).Generally,these comprehensive core-level spectroscopy methods based on hard X-rays at the E-line with an extremely high photon flux can meet the crucial requirements of a green energy strategy.Moreover,they provide substantial support for scientific advances in fundamental research. 展开更多
关键词 x-ray emission spectroscopy High-energy-resolution x-ray spectrometer Johann geometry Energy materials SSRF
下载PDF
Optimized online filter stack spectrometer for ultrashort X-ray pulses
6
作者 Jia-Xing Wen Ge Ma +17 位作者 Ming-Hai Yu Yu-Chi Wu Yong-Hong Yan Shao-Yi Wang Huai-Zhong Gao Lu-Shan Wang Yu-Gang Zhou Qiang Li Yue Yang Fang Tan Xiao-Hui Zhang Jie Zhang Wen-Bo Mo Jing-Qin Su Wei-Min Zhou Yu-Qiu Gu Ming Zeng Zong-Qing Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期85-98,共14页
Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c... Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities. 展开更多
关键词 Filter stack spectrometer Laser plasma diagnostics x-ray diagnostics Scintillator PIN diode
下载PDF
L-shell x-ray fluorescence relative intensities for elements with 62≤Z≤83 at 18 keV and 23 keV by synchrotron radiation
7
作者 M Alqadi S AL-Humaidi +1 位作者 H Alkhateeb F Alzoubi 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期270-273,共4页
The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of... The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of the Synchrotron Light Center for Experimental Science and Applications in the Middle East(SESAME),Jordan.The experimentally measured results of the relative intensities were compared with the calculated results using the subshell fluorescence yield and the Coster-Kronig transition probabilities recommended by Campbell and the values based on the Dirac-Hartree-Slater model by Puri.The experimental and theoretical results are in agreement.In this work,L XRF relative intensities for the elements Sm,Gd,Tb,Er,Ta,W,Re,Hg,Pb and Bi at energies of 18 keV and 23 keV were measured. 展开更多
关键词 L shell x-ray fluorescence(XRF) relative intensities synchrotron radiation
下载PDF
Geochemical analysis of marine sediments using fused glass disc by X-ray fluorescence spectrometry 被引量:7
8
作者 夏宁 张勤 +1 位作者 姚德 李国会 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2008年第4期475-479,共5页
A method was developed for content determination of Na, Mg, A1, Si, P,S, C1, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Nb, Zr, Y, Sr, Rb, Ba, La and Ce etc. covering 26 major, minor, and trace elements in marine sedim... A method was developed for content determination of Na, Mg, A1, Si, P,S, C1, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Nb, Zr, Y, Sr, Rb, Ba, La and Ce etc. covering 26 major, minor, and trace elements in marine sediment samples using fused glass disc by X-ray Fluorescence spectrometry. Calibration was made using marine sediment certified reference materials and the synthetic standard samples prepared by mixing several marine sediments with stream sediment and carbonate standard samples in different proportions. The matrix effect was corrected using theoretical alpha coefficients, experience coefficients and the scattered radiation as the internal standard (for the trace elements). The accuracy of the method was evaluated by analysis of certified reference materials GBW07314, GBW07334 and GSMS6. The results are in good agreement with the certified values of the standards with RSD less than 2.60%, except for Y, Cr, Ga, Ce, La, Nb, Rb, and V with RSD less than 9.0% (n=12). 展开更多
关键词 marine sediment x-ray fluorescence spectrometry geochemical analysis multi-element analysis
下载PDF
X-ray fluorescence spectrometry determination of open-hearth furnace slag by pressed powder briquetting
9
作者 ZHANG Qiao TIAN Yi-Guang GUO Wu-Xue 《China Foundry》 SCIE CAS 2006年第1期36-40,共5页
A rapid analysis method of determining content of eight compounds of open-hearth furnace slag was developed using X-ray fluorescence spectrometry and pressed powder briquettes. Matrix effect was corrected using theore... A rapid analysis method of determining content of eight compounds of open-hearth furnace slag was developed using X-ray fluorescence spectrometry and pressed powder briquettes. Matrix effect was corrected using theoretical alpha coefficient. Grains-size effect was eliminated by optimized sample preparation technique parameters. Mineral effect was corrected with standard curve of specially made standard samples. The analysis results of TiO2, TFe, SiO2, MgO, Al2O3, CaO, MnO and P2O5 in slag samples showed that both precision and accuracy are comparable with that of chemical method. 展开更多
关键词 x-ray fluorescence spectrometry SLAG powder briquetting
下载PDF
Determination of Content of Eight Elements in Metal Coating Smeared on Waste Plastics by X-ray Fluorescence Spectrometry
10
作者 Zhou Liming Huang Shijie Yu Yangfeng 《Meteorological and Environmental Research》 CAS 2017年第4期66-68,共3页
X-ray fluorescence spectrometry was used to detect the content of eight elements in metal coating smeared on waste plastics,and effects of sample cups,elements in plastic substrate,and interaction of elements in metal... X-ray fluorescence spectrometry was used to detect the content of eight elements in metal coating smeared on waste plastics,and effects of sample cups,elements in plastic substrate,and interaction of elements in metal coating on detection results were analyzed. The results show that the RSD of the method used to detect element content in the metal coating smeared on the waste plastics ranged from 0.008% to 0.044%; the determination range of the eight elements was 0.002%-52.0%,and their detection limit ranged from 0.0002% to 0.0008%. The determination results of X-ray fluorescence spectrometry were consistent with that of ICP-AES. The method can provide technical support for the determination of damage and pollution caused by metal coating smeared on waste plastics. 展开更多
关键词 x-ray fluorescence spectrometRY ELEMENTS Metal coating WASTE PLASTICS
下载PDF
SMONTE CARLO CALCULATION FOR CALIBRATION FUNCTIONS IN TOTAL REFLECTION X-RAY FLUORESCENCE SPECTROMETRY
11
作者 范钦敏 刘亚雯 魏成连 《Nuclear Science and Techniques》 SCIE CAS CSCD 1995年第1期14-17,共4页
Simulation approach includes such processes as photon emissions from X-ray tube with a spectral distribution, total reflection on the sample support, photoelectric effect in thin layer sample, as well as characteristi... Simulation approach includes such processes as photon emissions from X-ray tube with a spectral distribution, total reflection on the sample support, photoelectric effect in thin layer sample, as well as characteristic line absorption and detection. The calculation results are in agreement with experimental ones. 展开更多
关键词 Total reflection x-ray fluorescence analysis Calibration function Monte Carlo simulation
下载PDF
Quantitative Analysis of FeMo Alloys by X-Ray Fluorescence Spectrometry
12
作者 Sung-Mo Jung 《American Journal of Analytical Chemistry》 2014年第12期766-774,共9页
A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation... A quantitative analysis method of molybdenum in FeMo alloys by X-ray spectrometry using borate fusion technique was compared with that with pressed pellet. The complete pre-oxidation of FeMo alloys for the preparation of homogeneous fused discs was achieved by employing an automated fusion machine equipped with specially designed O2-blowing nozzles, which used lithium tetra-borate as flux with the addition of lithium nitrate (LiNO3) as oxidizer. The calibration curves of Mo and Fe were used in the quantitative analysis of standard materials and unknown plant samples with satisfactory accuracy and precision, utilizing the corrections of the matrix effects and line overlap. It was confirmed that the newly proposed method of preparing fused glass discs of FeMo alloys can replace the conventional wet chemical analyses requiring the labor intensive and time consuming procedure. 展开更多
关键词 FeMo ALLOYS x-ray fluorescence spectrometRY BORATE FUSION PRE-OXIDATION Calibration Standard Quantification
下载PDF
Potential Applications of X-ray Fluorescence Core Scanner in Elemental Analyses of the Muddy Sediments on the Coastal Shelves of China and in Ecological Study 被引量:2
13
作者 ZHOU Xin SUN Liguang +1 位作者 LIU Yi WANG Yuhong 《Journal of Ocean University of China》 SCIE CAS 2013年第4期619-623,共5页
Large areas of muddy sediments on the coastal shelves of China provide important samples for studying climate and ecological changes. Analysis of a large number of such samples, which is essential for systematic study... Large areas of muddy sediments on the coastal shelves of China provide important samples for studying climate and ecological changes. Analysis of a large number of such samples, which is essential for systematic study on environmental information recorded in mud areas because of complicated sedimentary environment and variable sedimentary rate, requires a fast and economical method. In this study, we investigated the potential of X-ray fluorescence core scanner (XRFS), a fast analytical instrument for measuring the elemental concentrations of muddy sediments, and observed a significant correlation between the element concentrations of muddy sediments determined by regular X-ray fluorescence spectrometer (XRF) and XRFS, respectively. The correlations are mainly determined by excitation energy of elements, but also influenced by solubility of element ions. Furthermore, we found a striking link between A1 concentrations and marine-originated organic carbon (MOC), a proxy of marine primary productivity. This indicates that MOC is partly controlled by sedimentary characteristics. Therefore, XRFS method has a good potential in fast analysis of a large number of muddy sediment samples, and it can also be used to calibrate MOC in ecological study of coastal seas. 展开更多
关键词 x-ray fluorescence core scanner x-ray fluorescence spectrometer muddy sediment marine-originated organic carbon ecological study
下载PDF
Quantitative energy-dispersive X-ray fluorescence analysis for unknown samples using full-spectrum least-squares regression 被引量:6
14
作者 Yong-Li Liu Qing-Xian Zhang +2 位作者 Jian Zhang Hai-Tao Bai Liang-Quan Ge 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期149-159,共11页
The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectr... The full-spectrum least-squares(FSLS) method is introduced to perform quantitative energy-dispersive X-ray fluorescence analysis for unknown solid samples.Based on the conventional least-squares principle, this spectrum evaluation method is able to obtain the background-corrected and interference-free net peaks, which is significant for quantization analyses. A variety of analytical parameters and functions to describe the features of the fluorescence spectra of pure elements are used and established, such as the mass absorption coefficient, the Gi factor, and fundamental fluorescence formulas. The FSLS iterative program was compiled in the C language. The content of each component should reach the convergence criterion at the end of the calculations. After a basic theory analysis and experimental preparation, 13 national standard soil samples were detected using a spectrometer to test the feasibility of using the algorithm. The results show that the calculated contents of Ti, Fe, Ni, Cu, and Zn have the same changing tendency as the corresponding standard content in the 13 reference samples. Accuracies of 0.35% and 14.03% are obtained, respectively, for Fe and Ti, whose standard concentrations are 8.82% and 0.578%, respectively. However, the calculated results of trace elements (only tens of lg/g) deviate from the standard values. This may be because of measurement accuracy and mutual effects between the elements. 展开更多
关键词 Energy-dispersive x-ray fluorescence analysis Full-spectrum LEAST-SQUARES METHOD Effective atomic number Mass attenuation coefficient Fundamental parameter METHOD
下载PDF
Design and calibration of an elliptical crystal spectrometer for the diagnosis of proton-induced x-ray emission(PIXE)
15
作者 方言律 李东彧 +9 位作者 程浩 高原 申泽清 杨童 李昱泽 夏亚东 晏炀 颜莎 林晨 颜学庆 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期220-225,共6页
Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spur... Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spurted within nanoseconds and accompanied by strong electromagnetic pulses(EMP), so traditional multi-channel detectors are no longer applicable.In this work, we designed a reflective elliptical crystal spectrometer for the diagnosis of laser-PIXE. The device can detect the energy range of 1 keV–11 ke V with a high resolution. A calibration experiment was completed on the electrostatic accelerator of Peking University using samples of Al, Ti, Cu, and ceramic artifacts. The detection efficiency of the elliptical crystal spectrometer was obtained in the order of 10-9. 展开更多
关键词 elliptical crystal spectrometer proton-induced x-ray emission applications of laser ion accelera-tion
下载PDF
Elemental and proximate analysis of coal by x-ray fluorescence assisted laser-induced breakdown spectroscopy 被引量:4
16
作者 Zhihui TIAN Xiaolin LI +9 位作者 Gang WANG Lei ZHANG Jiaxuan LI Shuqing WANG Yu BAI Wanfei ZHANG Han YUE Xiaofei MA Wangbao YIN Suotang JIA 《Plasma Science and Technology》 SCIE EI CAS CSCD 2022年第8期55-63,共9页
Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in therm... Although laser-induced breakdown spectroscopy(LIBS),as a fast on-line analysis technology,has great potential and competitiveness in the analysis of chemical composition and proximate analysis results of coal in thermal power plants,the measurement repeatability of LIBS needs to be further improved due to the difficulty in controlling the stability of the generated plasmas at present.In this paper,we propose a novel x-ray fluorescence(XRF) assisted LIBS method for high repeatability analysis of coal quality,which not only inherits the ability of LIBS to directly analyze organic elements such as C and H in coal,but also uses XRF to make up for the lack of stability of LIBS in determining other inorganic ash-forming elements.With the combination of elemental lines in LIBS and XRF spectra,the principal component analysis and the partial least squares are used to establish the prediction model and perform multi-elemental and proximate analysis of coal.Quantitative analysis results show that the relative standard deviation(RSD) of C is 0.15%,the RSDs of other elements are less than 4%,and the standard deviations of calorific value,ash content,sulfur content and volatile matter are 0.11 MJ kg,0.17%,0.79% and 0.41%respectively,indicating that the method has good repeatability in determination of coal quality.This work is helpful to accelerate the development of LIBS in the field of rapid measurement of coal entering the power plant and on-line monitoring of coal entering the furnace. 展开更多
关键词 laser-induced breakdown spectroscopy(LIBS) x-ray fluorescence spectrometry(XRF) high repeatability measurement spectral calibration instability analysis
下载PDF
Use of portable X-ray fluorescence in the analysis of surficial sediments in the exploration of hydrothermal vents on the Southwest Indian Ridge 被引量:5
17
作者 LIAO Shili TAO Chunhui +3 位作者 LI Huaiming ZHANG Guoyin LIANG Jin YANG Weifang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第7期66-76,共11页
Hydrothermal plumes released from the eruption of sea floor hydrothermal fluids contain large amounts of oreforming materials. They precipitate within certain distances from the hydrothermal vent. Six surficial sedime... Hydrothermal plumes released from the eruption of sea floor hydrothermal fluids contain large amounts of oreforming materials. They precipitate within certain distances from the hydrothermal vent. Six surficial sediment samples from the Southwest Indian Ridge(SWIR) were analyzed by a portable X-ray fluorescence(PXRF) analyzer on board to find a favorable method fast and efficient enough for sea floor sulfide sediment geochemical exploration. These sediments were sampled near, at a moderate distance from, or far away from hydrothermal vents. The results demonstrate that the PXRF is effective in determining the enrichment characteristics of the oreforming elements in the calcareous sediments from the mid-ocean ridge. Sediment samples(〉40 mesh) have high levels of elemental copper, zinc, iron, and manganese, and levels of these elements in sediments finer than 40 mesh are lower and relatively stable. This may be due to relatively high levels of basalt debris/glass in the coarse sediments, which are consistent with the results obtained by microscopic observation. The results also show clear zoning of elements copper, zinc, arsenic, iron, and manganese in the surficial sediments around the hydrothermal vent. Sediments near the vent show relatively high content of the ore-forming elements and either high ratios of copper to iron content and zinc to iron content or high ratios of copper to manganese content and zinc to manganese content. These findings show that the content of the ore-forming elements in the sediments around hydrothermal vents are mainly influenced by the distance of sediments to the vent, rather than grain size. In this way, the PXRF analysis of surface sediment geochemistry is found to satisfy the requirements of recognition geochemical anomaly in mid-ocean ridge sediments. Sediments with diameters finer than 40 mesh should be used as analytical samples in the geochemical exploration for hydrothermal vents on mid-oceanic ridges. The results concerning copper, zinc, arsenic, iron, and manganese and their ratio features can be used as indicators in sediment geochemical exploration of seafloor sulfides. 展开更多
关键词 mid-ocean ridge sediments hydrothermal activity portable x-ray fluorescence geochemical exploration
下载PDF
Spatial resolution and image processing for pinhole camera-based X-ray fluorescence imaging: a simulation study 被引量:1
18
作者 Ze He Ning Huang +2 位作者 Peng Wang Zi-Han Chen Bo Peng 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第5期135-153,共19页
Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reco... Spatial resolution and image-processing methods for full-field X-ray fluorescence(FF-XRF)imaging using X-ray pinhole cameras were studied using Geant4simulations with different geometries and algorithms for image reconstruction.The main objectives were:(1)calculating the quantum efficiency curves of specific cameras,(2)studying the relationships between the spatial resolution and the pinhole diameter,magnification,and camera binning value,and(3)comparing image-processing methods for pinhole camera systems.Several results were obtained using a point and plane source as the X-ray fluorescence emitter and an array of 100×100 silicon pixel detectors as the X-ray camera.The quantum efficiency of a back-illuminated deep depletion(BI-DD)structure was above 30%for the XRF energies in the 0.8–9 keV range,with the maximum of 93.7%at 4 keV.The best spatial resolution of the pinhole camera was 24.7μm and 31.3 lp/mm when measured using the profile function of the point source,with the diameter of 20μm,magnification of 3.16,and camera bin of 1.A blind deconvolution algorithm with Gaussian filtering performed better than the Wiener filter and Richardson iterative methods on FF-XRF images,with the signal-to-noise ratio of 7.81 dB and improved signalto-noise ratio of 7.24 dB at the diameter of 120μm,magnification of 1.0,and camera bin of 1. 展开更多
关键词 Full-field x-ray fluorescence(FF-XRF) x-ray pinhole camera Spatial resolution Image processing
下载PDF
Simulation Study of Quantitative X-Ray Fluorescence Analysis of Ore Slurry Using Partial Least-Squares Regression 被引量:1
19
作者 林才寿 毛莉 +1 位作者 黄宁 安竹 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第5期427-430,共4页
X-ray fluorescence (XRF) in combination with partial least-squares (PLS) regression was employed to analyze the ore slurry grade. Using the Monte Carlo simulation code PENELOPE, X-ray fluorescence spectra of ore s... X-ray fluorescence (XRF) in combination with partial least-squares (PLS) regression was employed to analyze the ore slurry grade. Using the Monte Carlo simulation code PENELOPE, X-ray fluorescence spectra of ore samples were obtained. Good accuracy was achieved when this method was used to analyze elements with concentrations of several percent or above. It was demonstrated that the more the number of X-ray fluorescence spectra used to calibrate, the better the obtained accuracy. In this method detector resolution was found to have little or no effect on the results of quantitative analysis. The effect of the concentration of water was investigated as well, and it was found to have little influence on the results. 展开更多
关键词 x-ray fluorescence PLS ore slurry grade Monte Carlo simulation
下载PDF
Impact of Different Grinding Aids on Standard Deviation in X-Ray Fluorescence Analysis of Cement Raw Meal 被引量:3
20
作者 Andrew Aondoaver Tyopine Aondo Joseph Wangum Edwin Ameh Idoko 《American Journal of Analytical Chemistry》 2015年第5期492-494,共3页
X-ray fluorescence (XRF) analysis utilizes particle size which is resulted from milling of a material. The milling ensures uniform and fine grained powder. The finer and more uniform the particle size is, the better t... X-ray fluorescence (XRF) analysis utilizes particle size which is resulted from milling of a material. The milling ensures uniform and fine grained powder. The finer and more uniform the particle size is, the better the result and easier it is for material quality control. To ensure uniformity in particle size and finer powder, a comparative analysis was conducted with different grinding aids and pressed pellet method was used in obtaining analysis results. Pressed pellets of cement raw meal sample milled with different grinding aids (graphite, aspirin and lithium borate) were subjected to XRF. Graphite produced better particle size uniformity with a corresponding standard deviation that made quality control of raw meal easier and better than aspirin and lithium borate. 展开更多
关键词 x-ray fluorescence Pressed PELLETS Standard Deviation GRINDING AID Particle Size UNIFORMITY Comparative Analysis Cement RAW MEAL Quality Control
下载PDF
上一页 1 2 37 下一页 到第
使用帮助 返回顶部