期刊文献+
共找到429篇文章
< 1 2 22 >
每页显示 20 50 100
Shifting curves based on the detector integration effect for x-ray phase contrast imaging
1
作者 杨君 郭金川 +2 位作者 雷耀虎 易明皓 陈力 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期512-515,共4页
In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of... In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period.We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging. 展开更多
关键词 x-ray phase contrast imaging Talbot–Lau interferometer x-ray imaging
下载PDF
A new method for information retrieval in two-dimensional grating-based X-ray phase contrast imaging 被引量:1
2
作者 王志立 高昆 +4 位作者 陈健 葛昕 朱佩平 田扬超 吴自玉 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第11期547-553,共7页
Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refr... Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refraction directions. Recently, we have developed a novel reverse-projection (RP) method, which is capable of retrieving the object information efficiently with one-dimensional (1D) grating-based phase contrast imaging. In this contribution, we present its extension to the 2D grating-based X-ray phase contrast imaging, named the two-dimensional reverse- projection (2D-RP) method, for information retrieval. The method takes into account the nonlinear contributions of two refraction directions and allows the retrieval of the absorption, the horizontal and the vertical refraction images. The obtained information can be used for the reconstruction of the three-dimensionak phase gradient field, and for an improved phase map retrieval and reconstruction. Numerical experiments are carried out, and the results confirm the validity of the 2D-RP method. 展开更多
关键词 x-ray imaging phase contrast information retrieval shifting curve
下载PDF
Optical design of a novel near-infrared phase contrast imaging(NI-PCI)diagnostic on the HL-2A tokamak
3
作者 徐皓 龚少博 +11 位作者 余羿 许敏 兰涛 王志斌 石中兵 聂林 赵光义 刘灏 周艺轩 袁子豪 肖晨雨 陈坚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期31-37,共7页
The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of tr... The optical design of near-infrared phase contrast imaging(NI-PCI)diagnosis on HL-2A is introduced in this paper.This scheme benefits from the great progress of near-infrared laser technology and is a broadening of traditional phase contrast technology.This diagnostic can work as a keen tool to measure plasma wavenumber spectra by inferring string-integrated plasma density fluctuations.Design of both the front optical path which is the path before the laser transmitting into the tokamak plasma and the rear optics which is the path after the laser passing through the plasma is detailed.The 1550 nm laser is chosen as the probe beam and highprecision optical components are designed to fit the laser beam,in which a phase plate with a 194-nm-deep silver groove is the key.Compared with the conventional 10.6μm laser-based PCI system on HL-2A,NI-PCI significantly overcomes the unwanted phase scintillation effect and promotes the measurement capability of high-wavenumber turbulence with an increased maximal measurable wavenumber from 15 cm^(-1)to 32.6 cm^(-1). 展开更多
关键词 phase contrast imaging near infrared laser plasma laser diagnostic
下载PDF
Single-shot grating-based x-ray differential phase contrast imaging with a modified analyzer grating
4
作者 卫晨希 吴朝 +6 位作者 Faiz Wali 魏文彬 鲍园 骆荣辉 王磊 刘刚 田扬超 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期501-507,共7页
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa... X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging. 展开更多
关键词 x-ray phase contrast imaging single-shot decent resolution staggered grating computed tomography
下载PDF
A new method of detecting interferogram in differential phase-contrast imaging system based on special structured x-ray scintillator screen 被引量:6
5
作者 刘鑫 郭金川 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期193-197,共5页
An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and ... An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and difficulty of fabrication by a state of the art technique. On the basis of phase grating diffraction, a detecting model of the scintillator screen was built for analysing the phase and absorption information of objects. According to the analysis, a new method of phase retrievals based on two-images and the optimal structure of screen were presented. 展开更多
关键词 differential phase contrast x-ray scintillator screen phase retrieval
下载PDF
In-line X-ray phase-contrast imaging of murine liver microvasculature ex vivo 被引量:5
6
作者 LI Beilei XU Min +5 位作者 WU Weizhong PENG Guanyun ZHANG Xi PENG Yifeng SHI Hongcheng CHEN Shaoliang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2012年第1期10-14,共5页
Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.V... Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility.Barium sulfate and physiological saline were used as contrast agents for the blood vessels.Blood vessels of <Φ20μm could be detected by replacing resident blood with physiological saline or barium sulfate.An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image.It is demonstrated that selective angiography based on phase contrast X-ray imaging,with a physiological material of low Z elements (such as saline) being the contrast agent,is a viable imaging strategy.Further efforts will be focused on using the technique to image tumor angiogenesis. 展开更多
关键词 X射线成像 相衬成像 微血管 体外 小鼠 上海同步辐射装置 肿瘤血管生成 生理盐水
下载PDF
Nondestructive X-ray imaging of inner structure of soft tissues in phase contrast 被引量:2
7
作者 XIAOTi-Qiao ZHANGGui-Lin +3 位作者 XUHong-Jie TIANYu-Lian HUANGWan-Xia ZHUPei-Ping 《Nuclear Science and Techniques》 SCIE CAS CSCD 2003年第4期217-221,共5页
An experimental study on nondestructive X-ray imaging of inner structure of soft tissues in phase con-trast has been conducted with Beijing Synchrotron Radiation Facility (BSRF). Modification to the beamline setupwas ... An experimental study on nondestructive X-ray imaging of inner structure of soft tissues in phase con-trast has been conducted with Beijing Synchrotron Radiation Facility (BSRF). Modification to the beamline setupwas made to enlarge the X-ray beam section and consequently larger samples could be imaged. In-line setup was em-ployed for experiments. Results on a series of samples were given and soft-tissue details of less than 50 μm inside afresh goldfish were obtained. Diagnosis of tumor in its early stage was also investigated taking SD rats as the model.Tumor at the size of ~ 100μm was observed. Potential of this technique in clinic diagnosis was discussed. 展开更多
关键词 X射线成像 北京 同步加速器辐射装置 BSRF 肿瘤诊断
下载PDF
Simple phase extraction in x-ray differential phase contrast imaging
8
作者 刘鑫 郭金川 +2 位作者 雷耀虎 李冀 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第2期563-567,共5页
A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a stro... A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified. 展开更多
关键词 x-ray imaging x-ray interferometry Talbot and self-imaging effects phase contrast imaging
下载PDF
Influence of tube voltage and current on in-line phase contrast imaging using a microfocus x-ray source
9
作者 李晨 李政 +1 位作者 禹爱民 黎成权 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第8期2319-2324,共6页
In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehens... In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging. 展开更多
关键词 x-ray in-line phase contrast imaging Wigner distribution
下载PDF
Theory and method of dual-energy x-ray grating phase-contrast imaging
10
作者 荣锋 高艳 +2 位作者 郭翠娟 徐微 徐伟 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第10期597-602,共6页
The principle of dual-energy x-ray grating phase-contrast imaging(DEPCI) is clarified by using the theory of x-ray interference and Fresnel diffraction. A new method of retrieving phase from the two interferograms is ... The principle of dual-energy x-ray grating phase-contrast imaging(DEPCI) is clarified by using the theory of x-ray interference and Fresnel diffraction. A new method of retrieving phase from the two interferograms is proposed for DEPCI,and its feasibility is verified via simulation. Finally, the proposed method applied to DEPCI experiment demonstrates the effectiveness of the method. This paper lays the theoretical foundation for performance optimization of DEPCI and the further integration of DEPCI and computed tomography. 展开更多
关键词 x-ray imaging DUAL-ENERGY ANALYZER GRATING phase RETRIEVAL
下载PDF
Graphic Processing Unit Based Phase Retrieval and CT Reconstruction for Differential X-Ray Phase Contrast Imaging
11
作者 陈晓庆 王宇杰 孙建奇 《Journal of Shanghai Jiaotong university(Science)》 EI 2014年第5期550-554,共5页
Compared with the conventional X-ray absorption imaging, the X-ray phase-contrast imaging shows higher contrast on samples with low attenuation coefficient like blood vessels and soft tissues. Among the modalities of ... Compared with the conventional X-ray absorption imaging, the X-ray phase-contrast imaging shows higher contrast on samples with low attenuation coefficient like blood vessels and soft tissues. Among the modalities of phase-contrast imaging, the grating-based phase contrast imaging has been widely accepted owing to the advantage of wide range of sample selections and exemption of coherent source. However, the downside is the substantially larger amount of data generated from the phase-stepping method which slows down the reconstruction process. Graphic processing unit(GPU) has the advantage of allowing parallel computing which is very useful for large quantity data processing. In this paper, a compute unified device architecture(CUDA) C program based on GPU is introduced to accelerate the phase retrieval and filtered back projection(FBP) algorithm for grating-based tomography. Depending on the size of the data, the CUDA C program shows different amount of speed-up over the standard C program on the same Visual Studio 2010 platform. Meanwhile, the speed-up ratio increases as the size of data increases. 展开更多
关键词 grating-based phase contrast imaging parallel computing graphic processing unit(GPU) compute unified device architecture(CUDA) filtered back projection(FBP)
原文传递
Noise properties of multi-combination information in x-ray grating-based phase-contrast imaging
12
作者 Wali Faiz 李冀Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province,College of Physics and Optoelectronic Engineering,Shenzhen University +4 位作者 高昆 吴朝 雷耀虎 黄建衡 朱佩平 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第1期329-335,共7页
Grating-based x-ray phase contrast imaging has attracted increasing interest in recent decades as multimodal and laboratory source usable method.Specific efforts have been focused on establishing a new extraction meth... Grating-based x-ray phase contrast imaging has attracted increasing interest in recent decades as multimodal and laboratory source usable method.Specific efforts have been focused on establishing a new extraction method to perform practical applications.In this work,noise properties of multi-combination information of newly established information extraction method,so-called angular signal radiography method,are investigated to provide guidelines for targeted and specific applications.The results show that how multi-combination of images can be used in targeted practical applications to obtain a high-quality image in terms of signal-to-noise ratio.Our conclusions can also hold true for upcoming targeted practical applications such as biomedical imaging,non-destructive imaging,and materials science. 展开更多
关键词 grating-based phase-contrast imaging signal-to-noise ratio REFRACTION SCATTERING
下载PDF
Effects of Tube Voltage on Phase-Contrast Imaging for Different Microfocus X-Ray Tubes
13
作者 Jianbao Gui Zhanli Hu +1 位作者 Peter Z. Wu Hairong Zheng 《Engineering(科研)》 2013年第10期590-594,共5页
In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltag... In the past decade, phase-contrast imaging (PCI) has become a hot research with an increased improvement of the image contrast with respect to conventional absorption radiography. In this paper, effects of tube voltage (kVp) on propagation-based phase-contrast imaging have been investigated with two types of microfocus x-ray tubes, a conventional sealed x-ray tube with the focal spot size of 13 - 20 μm and an open x-ray tube with minimum focal spot size less than 2 μm. A cooled x-ray CCD detector with the pixel size of 24 μm was used to acquire digital images. Two thin plastic sheets with different thickness were used as radiography phantoms. Two different phenomena were observed for the two x-ray tubes. For the open tube, phase-contrast effect has a slight drop with the increasing of tube voltage, however, it is opposite for the sealed tube. A further investigation indicates that the variation of focal spot size causes the abnormal result for the sealed tube. It also shows that phase-contrast effect is more sensitive to focal spot size than tube voltage. 展开更多
关键词 phase-contrast imaging EDGE Enhancement x-ray TUBE VOLTAGE
下载PDF
Theory and verification of moiréfringes for x-ray three-phase grating interferometer
14
作者 单雨征 葛永帅 +5 位作者 杨君 郭大育 蔡学宝 刘晓珂 侯晓文 郭金川 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期532-540,共9页
Dual-phase and three-phase grating x-ray interference is a promising new technique for grating-based x-ray differential phase contrast imaging.Dual-phase grating interferometers have been relatively completely studied... Dual-phase and three-phase grating x-ray interference is a promising new technique for grating-based x-ray differential phase contrast imaging.Dual-phase grating interferometers have been relatively completely studied and discussed.In this paper,the corresponding imaging fringe formula of the three-phase grating interferometer is provided.At the same time,the similarities and differences between the three-phase grating interferometer and the dual-phase grating interferometer are investigated and verified,and that the three-phase grating interferometer can produce large-period moiréfringes without using the analyzing grating is demonstrated experimentally.Finally,a simple method of designing three-phase grating and multi-grating imaging systems from geometric optics based on the thin-lens theory of gratings is presented.These theoretical formulas and experimental results provide optimization tools for designing three-phase grating interferometer systems. 展开更多
关键词 x-ray phase contrast phase grating moiréfringe
下载PDF
X-ray phase-sensitive microscope imaging with a grating interferometer:Theory and simulation
15
作者 杨杰成 朱佩平 +2 位作者 梁栋 郑海荣 葛永帅 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第9期652-657,共6页
A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imagin... A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imaging and the improved image contrast.By using this theory,several key parameters of phase contrast imaging can be predicted,for instance,the fringe visibility and period,and the conversion condition from the differential phase imaging(DPI)to the phase difference imaging(PDI).Additionally,numerical simulations are performed with certain x-ray optical components and imaging geometry.Comparison with the available experimental measurement[Appl.Phys.Lett.113063105(2018)]demonstrates the accuracy of this developed quantitative analysis method of x-ray phase-sensitive microscope imaging. 展开更多
关键词 x-ray phase contrast imaging x-ray microscope grating interferometer
下载PDF
Progress of plasma density fluctuation measurements with phase contrast imaging on HL-2A tokamak 被引量:1
16
作者 龚少博 余羿 +15 位作者 许敏 孙爱萍 兰涛 聂林 柯锐 龙婷 刘灏 吴一帆 袁博达 王华杰 袁金榜 石中兵 钟武律 毛世峰 叶民友 段旭如 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第8期5-11,共7页
A CO2 laser-based phase contrast imaging(PCI) diagnostic has been developed on HL-2A tokamak.It can detect line integrated plasma density fluctuations by measuring the phase shift of laser beam after being scattered b... A CO2 laser-based phase contrast imaging(PCI) diagnostic has been developed on HL-2A tokamak.It can detect line integrated plasma density fluctuations by measuring the phase shift of laser beam after being scattered by the bulk plasma.The diagnosed radial region ranges from ρ≡r/a =0.625 to 0.7.32-channel HgCdTe detectors with alternative-current biased amplifiers are arranged in line at the imaging plane of the optical path.This PCI is able to diagnose density fluctuations with wavenumbers ranging from 2 to 15 cm-1 and the time resolution is better than 2 μs.The first experimental data were achieved in 2018 spring campaign of HL-2A tokamak.High performance is confirmed in different discharging configurations and makes it a keen tool in broadband turbulence investigations. 展开更多
关键词 phase contrast imaging phase SHIFT density FLUCTUATION TURBULENCE
下载PDF
Real time high accuracy phase contrast imaging with parallel acquisition speckle tracking 被引量:1
17
作者 胡哲 滑文强 王劼 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第6期282-286,共5页
X-ray speckle tracking based methods can provide results with best reported angular accuracy up to 2 nrad. However,duo to the multi-frame requirement for phase retrieval and the possible instability of the x-ray beam,... X-ray speckle tracking based methods can provide results with best reported angular accuracy up to 2 nrad. However,duo to the multi-frame requirement for phase retrieval and the possible instability of the x-ray beam, mechanical and background vibration, the actual accuracy will inevitably be degraded by these time-dependent fluctuations. Therefore,not only spatial position, but also temporal features of the speckle patterns need to be considered in order to maintain the superiority of the speckle-based methods. In this paper, we propose a parallel acquisition method with advantages of real time and high accuracy, which has potential applicability to dynamic samples imaging as well as on-line beam monitoring.Through simulations, we demonstrate that the proposed method can reduce the phase error caused by the fluctuations to1% at most compared with current speckle tracking methods. Meanwhile, it can keep the accuracy deterioration within0.03 nrad, making the high theoretical accuracy a reality. Also, we find that waveforms of the incident beam have a little impact on the phase retrieved and will not influence the actual accuracy, which relaxes the requirements for speckle-based experiments. 展开更多
关键词 phase contrast imaging near field speckle grating splitter
下载PDF
Contrast enhancement of medical ultrasound imaging with reversal phase-inversion pulse technology 被引量:1
18
作者 李琴 谭冠政 A.S.M.Libda 《Journal of Central South University》 SCIE EI CAS 2013年第3期696-701,共6页
A new ultrasound contrast imaging technique was proposed for eliminating the harmonic components from the emission signal transmitted by the broadband ultrasonic system.Reversal phase-inversion pulse was used for the ... A new ultrasound contrast imaging technique was proposed for eliminating the harmonic components from the emission signal transmitted by the broadband ultrasonic system.Reversal phase-inversion pulse was used for the first time to separate the contrast harmonics from the harmonics in the emission signal to improve the detection of contrast micro-bubbles.Based on the nonlinear acoustic theory of finite-amplitude effects and the associated distortion of the propagating wave,the Bessel-Fubini series model was applied to describe the nonlinear propagation effects of the reversal phase-inversion pulse,and the Church's equation for zero-thickness encapsulation model was used to produce the scattering-pulse of the bubble.For harmonic imaging,the experiment was performed using a 64-element linear array,which was simulated by Field II.The results show that the harmonic components from the emission signal can be completely cancelled,and the harmonics generated by the nonlinear propagation of the wave through the tissue,can be reduced by 15-30 dB.Compared with the short pulse,the reversal phase-inversion pulse can improve the contrast and definition of the harmonic image significantly. 展开更多
关键词 对比度增强 脉冲技术 超声成像 反转 相位 非线性传播 高次谐波 发射信号
下载PDF
Wide-Field Vibrational Phase Contrast Imaging Based on Coherent Anti-Stokes Raman Scattering Holography 被引量:1
19
作者 吕永钢 纪子衡 +2 位作者 董大山 施可彬 龚旗煌 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第7期86-89,共4页
We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microsco... We propose and implement a wide-field vibrational phase contrast detection to obtain imaging of imaginary components of third-order nonlinear susceptibility in a coherent anti-Stokes Raman scattering (CARS) microscope with full suppression of the non-resonant background. This technique is based on the unique ability of recovering the phase of the generated CARS signal based on holographic recording. By capturing the phase distributions of the generated CARS field from the sample and from the environment under resonant illumination, we demonstrate the retrieval of imaginary components in the CARS microscope and achieve background free coherent Raman imaging. 展开更多
关键词 Wide-Field Vibrational phase contrast imaging Based on Coherent Anti-Stokes Raman Scattering Holography
下载PDF
Elemental x-ray imaging using Zernike phase contras
20
作者 邵其刚 陈健 +5 位作者 Faiz Wali 鲍园 王志立 朱佩平 田扬超 高昆 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第10期545-548,共4页
We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images ar... We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images are subtracted to obtain the target element: one is at the absorption edge of the target element and the other is near the absorption edge. The x-ray exposure required by this method is expected to be significantly lower than that of conventional absorption-based x-ray elemental imaging methods. Numerical calculations confirm the advantages of this highly efficient imaging method. 展开更多
关键词 x-ray imaging Zernike phase contrast elemental imaging
下载PDF
上一页 1 2 22 下一页 到第
使用帮助 返回顶部