Our objective is to describe a novel ligamentolysis approach using a subcoronal incision technique and to determine its safety and efficacy. During the last 7 years, 82 consecutive patients had penile augmentation sur...Our objective is to describe a novel ligamentolysis approach using a subcoronal incision technique and to determine its safety and efficacy. During the last 7 years, 82 consecutive patients had penile augmentation surgery. Ligamentolysis, through a lower abdominal incision (V-Y plasty) in the first 35 males, was performed (Group A), followed by circumcision ligamentolysis in the next 47 males (Group B). The operation time, complications, and the preoperative and postoperative values of penile length and girth along with the self-esteem and relations questionnaire score as well as satisfaction score was calculated before and after the surgery, and a comparison was conducted between the groups. The mean age at presentation was 32 years (range: 18-56 years). Seventy-nine patients suffered from penile dysmorphophobia, and three patients had micropenises (length 〈7.5 cm). The mean surgical times were 150.7 and 125.2 rain for Groups A and B, respectively (P=0.005). Postoperatively, four Group A patients and three Group B patients (11% versus 6%, respectively) experienced penile retraction (P=0.453). Hypertrophic scars were observed in 18 men (51%) in the former group. In the circumcision group, no major wound complications were recorded. The length and girth improvements between the groups were similar. In terms of satisfaction and SEAR improvement, the resulting difference for both variables favored the circumcision group (P=0.007 and 〈0.001, respectively). With strict selection criteria, the circumcision ligamentolysis procedure compared to the V-Y plasty demonstrated improved results in terms of safety, operation time, retraction rate and cosmetic appearance without any compromise in the gained penile size.展开更多
The reconstruction of the vascular outflow tract of partial liver grafts has received considerable attention in the past, especially in the setting of right liver grafts with undrained segments. Hepatic venous outflow...The reconstruction of the vascular outflow tract of partial liver grafts has received considerable attention in the past, especially in the setting of right liver grafts with undrained segments. Hepatic venous outflow reconstruction is an important factor for successful living donor liver transplantation outcome. However, in presence of undrained anterior sector and presence of multiple short hepatic veins that drain substantial portions of liver, outflow reconstruction without backtable venoplasty may lead to severe graft congestion and subsequent graft dysfunction. Various backtable venoplasty techniques in presence of multiple hepatic veins that can be used in either right- or leftlobe liver transplantation are devised to ensure a single, wide outflow channel. In this overview, various techniques to overcome the hepatic venous variations of liver allograft and outflow reconstruction are discussed.展开更多
文摘Our objective is to describe a novel ligamentolysis approach using a subcoronal incision technique and to determine its safety and efficacy. During the last 7 years, 82 consecutive patients had penile augmentation surgery. Ligamentolysis, through a lower abdominal incision (V-Y plasty) in the first 35 males, was performed (Group A), followed by circumcision ligamentolysis in the next 47 males (Group B). The operation time, complications, and the preoperative and postoperative values of penile length and girth along with the self-esteem and relations questionnaire score as well as satisfaction score was calculated before and after the surgery, and a comparison was conducted between the groups. The mean age at presentation was 32 years (range: 18-56 years). Seventy-nine patients suffered from penile dysmorphophobia, and three patients had micropenises (length 〈7.5 cm). The mean surgical times were 150.7 and 125.2 rain for Groups A and B, respectively (P=0.005). Postoperatively, four Group A patients and three Group B patients (11% versus 6%, respectively) experienced penile retraction (P=0.453). Hypertrophic scars were observed in 18 men (51%) in the former group. In the circumcision group, no major wound complications were recorded. The length and girth improvements between the groups were similar. In terms of satisfaction and SEAR improvement, the resulting difference for both variables favored the circumcision group (P=0.007 and 〈0.001, respectively). With strict selection criteria, the circumcision ligamentolysis procedure compared to the V-Y plasty demonstrated improved results in terms of safety, operation time, retraction rate and cosmetic appearance without any compromise in the gained penile size.
文摘The reconstruction of the vascular outflow tract of partial liver grafts has received considerable attention in the past, especially in the setting of right liver grafts with undrained segments. Hepatic venous outflow reconstruction is an important factor for successful living donor liver transplantation outcome. However, in presence of undrained anterior sector and presence of multiple short hepatic veins that drain substantial portions of liver, outflow reconstruction without backtable venoplasty may lead to severe graft congestion and subsequent graft dysfunction. Various backtable venoplasty techniques in presence of multiple hepatic veins that can be used in either right- or leftlobe liver transplantation are devised to ensure a single, wide outflow channel. In this overview, various techniques to overcome the hepatic venous variations of liver allograft and outflow reconstruction are discussed.