AIM:To evaluate the Z-line visualization by the PillCamTM SB2 using three different ingestion protocols. METHODS:Ninety consecutive patients undergoing small bowel capsule endoscopy(SBCE)between January and May 2008 w...AIM:To evaluate the Z-line visualization by the PillCamTM SB2 using three different ingestion protocols. METHODS:Ninety consecutive patients undergoing small bowel capsule endoscopy(SBCE)between January and May 2008 were included in the study. They swallowed the capsule in the standing(Group A= 30),supine(Group B=30)and right supine positions (Group C=30).Baseline patient characteristics, difficulties in capsule ingestion,esophageal transit times(ETT)and Z-line visualization were noted. RESULTS:No significant differences were found between the groups with regard to baseline patient characteristics,ingestion difficulties and complete SB examinations(P>0.05).At least 1 frame of the Z-line was detected in 15.8%,46.7%and 90%of patients in groups A,B and C,respectively(P<0.001).The average number of Z-line images was 0.21±0.53,3.23 ±6.59 and 5.53±7.55 and the mean%of the Z-linedetected was 71.3,25.1 and 8.3,in groups A,B and C, respectively(both P<0.001).ETT times were longer in the supine group followed by the right supine and the standing groups(median of 237 s vs 64 s and 39 s, respectively;P<0.001). CONCLUSION:Z-line visualization in patients undergoing SBCE can be accurately achieved in most cases when the capsule is swallowed in the right supine position.展开更多
介绍了一种用于丝阵Z箍缩(Z-pinch)内爆实验研究的脉冲放电模块的设计。模块基于直线型变压器驱动器(LTD)技术,包含34个放电支路,通过4个铁基非晶磁芯耦合。每支路由2个40nF电容器和1只4间隙串联气体开关组成,回路电感为220nH。设计了...介绍了一种用于丝阵Z箍缩(Z-pinch)内爆实验研究的脉冲放电模块的设计。模块基于直线型变压器驱动器(LTD)技术,包含34个放电支路,通过4个铁基非晶磁芯耦合。每支路由2个40nF电容器和1只4间隙串联气体开关组成,回路电感为220nH。设计了水电阻负载检验模块输出性能,在匹配状态下,负载上的输出电流峰值916 k A,上升时间99.8 ns。设计了磁绝缘传输线将输出脉冲传输至Z-pinch丝阵负载,并利用"零维模型"对LTD模块和负载的耦合放电进行了模拟计算。结果显示,丝阵负载上的放电电流峰值可达960 k A,上升时间为114 ns。展开更多
文摘AIM:To evaluate the Z-line visualization by the PillCamTM SB2 using three different ingestion protocols. METHODS:Ninety consecutive patients undergoing small bowel capsule endoscopy(SBCE)between January and May 2008 were included in the study. They swallowed the capsule in the standing(Group A= 30),supine(Group B=30)and right supine positions (Group C=30).Baseline patient characteristics, difficulties in capsule ingestion,esophageal transit times(ETT)and Z-line visualization were noted. RESULTS:No significant differences were found between the groups with regard to baseline patient characteristics,ingestion difficulties and complete SB examinations(P>0.05).At least 1 frame of the Z-line was detected in 15.8%,46.7%and 90%of patients in groups A,B and C,respectively(P<0.001).The average number of Z-line images was 0.21±0.53,3.23 ±6.59 and 5.53±7.55 and the mean%of the Z-linedetected was 71.3,25.1 and 8.3,in groups A,B and C, respectively(both P<0.001).ETT times were longer in the supine group followed by the right supine and the standing groups(median of 237 s vs 64 s and 39 s, respectively;P<0.001). CONCLUSION:Z-line visualization in patients undergoing SBCE can be accurately achieved in most cases when the capsule is swallowed in the right supine position.
文摘介绍了一种用于丝阵Z箍缩(Z-pinch)内爆实验研究的脉冲放电模块的设计。模块基于直线型变压器驱动器(LTD)技术,包含34个放电支路,通过4个铁基非晶磁芯耦合。每支路由2个40nF电容器和1只4间隙串联气体开关组成,回路电感为220nH。设计了水电阻负载检验模块输出性能,在匹配状态下,负载上的输出电流峰值916 k A,上升时间99.8 ns。设计了磁绝缘传输线将输出脉冲传输至Z-pinch丝阵负载,并利用"零维模型"对LTD模块和负载的耦合放电进行了模拟计算。结果显示,丝阵负载上的放电电流峰值可达960 k A,上升时间为114 ns。