期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
急性前壁心梗心电图与梗死相关血管的关系 被引量:4
1
作者 田江华 张海澄 卢广平 《保健医学研究与实践》 2013年第2期43-44,47,共3页
目的探讨ST段抬高型急性前壁心肌梗塞(AAMI)心电图改变与梗死相关冠状动脉(IRA)的关系。方法对84例经冠状动脉造影(CAG)证实的ST段抬高型AAMI患者的体表心电图进行回顾性分析。结果 AAMI有I、AVL导联ST段抬高,Ⅲ、AVF下移。闭塞部位多... 目的探讨ST段抬高型急性前壁心肌梗塞(AAMI)心电图改变与梗死相关冠状动脉(IRA)的关系。方法对84例经冠状动脉造影(CAG)证实的ST段抬高型AAMI患者的体表心电图进行回顾性分析。结果 AAMI有I、AVL导联ST段抬高,Ⅲ、AVF下移。闭塞部位多在左前降支(LAD)近段或远段并第一对角支病变,其敏感性、特异性分别为67.6%和84.0%。AAMI伴有Ⅱ、Ⅲ、AVF导联ST段抬高者,病变血管多见于LAD近段、中段合并左回旋支(LCX)或LAD远段,其敏感性为61.5%,特异性为97.5%。结论心电图可用于初步判断ST段抬高型AAMI患者,并与动脉血管闭塞部位有相关性,对临床有重要的参考价值。 展开更多
关键词 AAMI 体表心电图 zra LAD RCA LCX
下载PDF
316L与X65在模拟流动地层水中电偶腐蚀行为 被引量:5
2
作者 罗睿 余世杰 +1 位作者 袁鹏斌 欧阳志英 《装备环境工程》 CAS 2016年第4期162-167,共6页
目的研究316L与X65在模拟流动地层水中电偶腐蚀行为,方法进行复合管材料X65和316L耦合在模拟流动地层水饱和CO2环境中的浸泡实验,通过电化学工作站测量电偶电流、电偶电位、开路电位及试样在不同温度和流速下极化曲线和交流阻抗图谱,另... 目的研究316L与X65在模拟流动地层水中电偶腐蚀行为,方法进行复合管材料X65和316L耦合在模拟流动地层水饱和CO2环境中的浸泡实验,通过电化学工作站测量电偶电流、电偶电位、开路电位及试样在不同温度和流速下极化曲线和交流阻抗图谱,另外通过电子扫描显微镜观察腐蚀形貌,对复合管电偶腐蚀行为进行分析。结果在模拟流速为0,0.2 m/s地层水中,X65耦合后的腐蚀速率分别为0.883,1.169 mm/a。结论 X65阳极反应极化程度较小,316L的阴极反应过程是整体反应速度的控制步骤。X65表面不仅发生阳极溶解,还伴随阴极反应。 展开更多
关键词 复合管 电偶腐蚀 零电阻电流 Tafel
下载PDF
Corrosion Behaviour of Carbon Steel Fasteners in Neutral Chloride Solution 被引量:3
3
作者 Enobong Felix Daniel Junhua Dong +5 位作者 Xiaofang Li Ini-Ibehe Nabuk Etim Inime Ime Udoh Rongyao Ma Lei Chen Changgang Wang 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2022年第4期563-576,共14页
An experimental model for simulating the corrosion of carbon steel fasteners(bolt and nut) composed of a contact carbon steel electrode(CCSE) and an exposed bare carbon steel plate electrode(BCSE) was designed. The ef... An experimental model for simulating the corrosion of carbon steel fasteners(bolt and nut) composed of a contact carbon steel electrode(CCSE) and an exposed bare carbon steel plate electrode(BCSE) was designed. The effect of coupling on the corrosion process of the galvanically coupled carbon steel electrode was evaluated and compared with the self-corrosion process observed independently at the exposed and contact regions. Results obtained indicated that at an equal area ratio and uncoupled conditions, the corrosion rate is accelerated in the surface directly exposed to bulk solution compared to the bolt surface in contact with the nut. A coupling current was recorded when the exposed surface(BCSE) was electrically connected with the contact surface(CCSE);with the CCSE acting as the anode thereby suppressing the corrosion process in the exposed surface. By implication, the galvanic coupling between CCSE and BCSE increased the corrosion rate of CCSE. The diff erence in oxygen supply was responsible for the coupling effect observed in the system as there was no decrease in the solution pH. Moreover, varying the cathode-to-anode area( S c/S a) ratio significantly influenced the corrosion current density as increased S c/S a ratio resulted in an accelerated galvanic corrosion process. The corroded surfaces and interfaces were analysed using stereomicroscopy and scanning electron microscopy. X-ray diff ractometry was adopted for corrosion product characterization. The results obtained showed supportive evidence of the corrosion behaviour in carbon steel fasteners. 展开更多
关键词 Bolt and nut Galvanic current density Zero resistance ammetry(zra) Coupling potential Differential aeration cell Carbon steel fasteners
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部