期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Investigation on Flow Accelerated Corrosion Mitigation for Secondary Circuit Piping of the Third Qinshan Nuclear Power Plant 被引量:3
1
作者 ZHAO Liang HU Jianqun +1 位作者 WU Zhigang WANG Kin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第2期214-219,共6页
Flow accelerated corrosion(FAC) is the main failure cause of the secondary circuit carbon steel piping in nuclear power plants.The piping failures caused by FAC have resulted in numerous unplanned outages and tragic... Flow accelerated corrosion(FAC) is the main failure cause of the secondary circuit carbon steel piping in nuclear power plants.The piping failures caused by FAC have resulted in numerous unplanned outages and tragic fatalities.The existing researches focus on the main factors contributing to FAC,which include metallurgical factors,environmental factors and hydrodynamic factors. Some effective FAC management methods and programs with long term monitoring and inspection data analysis are recommended.But a comprehensive FAC management system should be developed in order to mitigate and manage FAC systematically.In this paper,the FAC influencing factors are analyzed in combination with the operating conditions of the secondary circuit piping in the Third Qinshan Nuclear Power Plant(TQNPP),China(Third Qinshan Nuclear Power Company Limited,China).A comprehensive FAC mitigation and management system is developed for TQNPP secondary circuit piping.The system is composed of five processes,viz.materials substitution,water chemical optimization,long-term monitor strategy for the susceptible piping,integrity evaluation of the local thinning defects,and repair or replacement.With the implementation of the five processes,the material of FAC sensitive pipe fittings are modified from carbon steel to stainless steel,N_2H_4 and NH_3 are finally selected as the water chemical regulator of secondary circuit,the secondary circuit pips are classified according to FAC susceptibility in order to conduct long term monitoring strategy,and an integrity evaluation flow for local thinning caused by FAC in carbon steel piping is developed.If the component with local thinning defects is not fit-for-service,corresponding repair or replacement should be conducted.The comprehensive FAC mitigation and management system with five interrelated processes would be a cost-effective method of increasing personnel safety,plant safety and availability. 展开更多
关键词 flow accelerated corrosion nuclear power plant secondary circuit piping
下载PDF
Evaluation of Corrosion Degradation Law of Recycled Reinforced Concrete in Saline Soil Under Electrified Environment
2
作者 李琼 乔宏霞 LI Aoyang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2023年第3期632-644,共13页
In order to investigate the corrosion mechanism of recycled reinforced concrete (RRC) under harsh environments,four recycled coarse aggregate (RCA) contents were selected,and saline soil was used as an electrolyte to ... In order to investigate the corrosion mechanism of recycled reinforced concrete (RRC) under harsh environments,four recycled coarse aggregate (RCA) contents were selected,and saline soil was used as an electrolyte to perform electrified accelerated corrosion experiments.The relative dynamic elastic modulus and relative corrosion current density were considered to describe the deterioration law of the RRC in saline soil.The results indicated that as the energization time increased,the corrosion current density,corrosion potential,and polarization resistance of the steel bar decreased gradually.Compared with ordinary reinforced concrete,when the RCA content was 30%,the ability of the RRC to resist corrosion was improved slightly;however,when the RCA content exceeded 30%,the corrosion resistance of the RRC deteriorated rapidly.Scanning electron microscopy revealed that for a dense RRC,less corrosion products were generated in the pores inside the concrete and on the surface of the steel bar.X-ray diffraction results indicated that SO_(4)^(2-) can generate ettringite and other corrosion products,along with volume expansion.The main corrosion products generated on the surface of the steel bars included Fe_(2)O_(3),Fe_(3)O_(4) and FeO(OH),which were the corrosion products generated by steel bars under natural environments.Therefore,using saline soil as an electrolyte is more consistent with the actual service environments of RRC.Both the relative dynamic mode and relative corrosion current density of the degradation parameters conform to the Weibull distribution;furthermore,the relative dynamic mode is more sensitive and the corresponding reliability curve can better describe the degradation law of RRC under saline soil environments. 展开更多
关键词 recycled aggregate concrete corrosion mechanism saline soil accelerated corrosion durability evaluation parameters
下载PDF
Effect of nonmetallic inclusions on localized corrosion of spring steel 被引量:3
3
作者 Wei-ning Shi Shu-feng Yang Jing-she Li 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2021年第3期390-397,共8页
Certain inclusions in high-strength 60Si2Mn-Cr spring steel result in poor resistance to localized corrosion.In this work,to study the effect of inclusions on the localized corrosion behavior of spring steel,accelerat... Certain inclusions in high-strength 60Si2Mn-Cr spring steel result in poor resistance to localized corrosion.In this work,to study the effect of inclusions on the localized corrosion behavior of spring steel,accelerated corrosion tests were performed by immersing spring steel in 3wt%FeCl_(3)solution for different times.The results show that severe corrosion occurred in areas of clustered CaS inclusions.Sulfide inclusions containing Ca and Mg induced the strongest localized corrosion susceptibility.For the case of(Ca,Mn,Mg)S inclusions,the ability to induce localized corrosion susceptibility is ranked as follows:MgS>CaS>MnS.Moreover,CaS,(Ca,Mn)S,and(Ca,Mn,Mg)S inclusions were mainly responsible for inducing environmental embrittlement. 展开更多
关键词 STEEL localized corrosion INCLUSIONS accelerated corrosion tests
下载PDF
Effect of Thermal Shock Process in Accelerated Environment Spectrum on the Fatigue Life of 7B04-T6 Aluminum Alloy 被引量:1
4
作者 崔腾飞 刘道新 +1 位作者 ZHANG Xiaohua YU Shouming 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2016年第5期1109-1116,共8页
The effect of thermal shock, in an accelerated-corrosion environment spectrum, on the fatigue and corrosion behavior of 7B04-T6 aluminum alloy, was determined. The environment spectrum consists of two modules, namely... The effect of thermal shock, in an accelerated-corrosion environment spectrum, on the fatigue and corrosion behavior of 7B04-T6 aluminum alloy, was determined. The environment spectrum consists of two modules, namely: salt-spray corrosion and thermal shock. The effect of thermal shock on the mechanical properties was determined via tensile tests; SEM, DCS, and XRD were used to determine the effect of thermal shock on the corrosion products. In addition, the corrosion resistance of the products was ascertained through electrochemical testing. The results show that the mechanical properties and fatigue life of the aluminum alloy will decline with prolonged thermal shock time. The thermal shock process may result in denser surface corrosion products than those formed on the no thermal shock specimens, and transformation of some Al(OH)_3 into Al OOH. Al OOH may have resulted in improved corrosion resistance and hence a lower decrease in the fatigue life after corrosion, compared with that of the no thermal shock specimen. Repeated corrosion/thermal shock may have delayed further decease in the fatigue life. Therefore, selection of an appropriate equivalent thermal shock temperature and time was essential for designing the environmental spectrum. 展开更多
关键词 accelerated corrosion environment spectrum thermal shock corrosion fatigue aluminum alloy
下载PDF
Comparison between FAC Analysis Result Using ToSPACE &CHECWORKS Programs and Experimental Result
5
作者 K. M. Hwang H. Yun +4 位作者 H. K. Seo E. J. Jung J. S. Im K. M. Kim D. J. Kim 《World Journal of Nuclear Science and Technology》 2020年第4期158-170,共13页
A number of piping components in the secondary system of nuclear power plants (NPPs) have been exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), cavitation, flashing, LDIE (Liquid Droplet Impingeme... A number of piping components in the secondary system of nuclear power plants (NPPs) have been exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), cavitation, flashing, LDIE (Liquid Droplet Impingement Erosion), and SPE (Solid Particle Erosion). Those mechanisms may lead to thinning, leaking, or the rupture of components. Due to the pipe ruptures caused by wall thinning of Surry Unit 2 in 1986 and Mihama Unit 3 in 2004, pipe wall thinning management has emerged as one of the most important issues in the nuclear industry. To manage the wall thinning of pipes caused by FAC and erosion, KEPCO-E & C has developed ToSPACE program. It can predict both FAC & erosion phenomena, and also be utilized in the pipe wall thinning management works such as susceptibility analysis, UT (Ultrasonic Test) data evaluation as well as establishment of long-term inspection plan. Even though the ToSPACE can predict the five aging mechanisms mentioned above, only the FAC prediction result using ToSPACE was compared herein with the experimental result using FACTS (Flow Accelerated Corrosion Test System) to verify the ToSPACE’s capability. In addition, the FAC prediction result using ToSPACE was also compared with that of CHECWORKS that is widely used all over the world. 展开更多
关键词 ToSPACE FACTS (Flow accelerated corrosion Test System) Pipe Wall Thinning Flow-accelerated corrosion (FAC)
下载PDF
Laboratory and field testing of bolting systems subjected to highly corrosive environments 被引量:2
6
作者 Meikle Tom Tadolini Stephen C. +1 位作者 Sainsbury Bre-Anne Bolton John 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2017年第1期101-106,共6页
The capacity of ground support components which have been affected by corrosion is reduced and may ultimately lead to dynamic failure of the component and the strata. In order to maintain an effective,long-term ground... The capacity of ground support components which have been affected by corrosion is reduced and may ultimately lead to dynamic failure of the component and the strata. In order to maintain an effective,long-term ground support system, significant campaigns of rehabilitation are often required in corrosion affected areas which also expose the workers to hazardous conditions. The most common corrosion protection for steel ground support utilises sacrificial systems such as galvanising. Galvanising has previously been proven to be susceptible to some corrosion processes. Stainless steel is the most effective in resistance to corrosion, but can be cost prohibitive, and its mechanical properties often make it unsuited to use in ground support components. Providing an outer protective plastic coating to bolts has proven to be an effective means of protecting the inner steel bar from corrosion. However, these support systems tend to be susceptible to coating damage, and require post cement grouting to provide full encapsulation. In comparison to a standard bolt/resin system, they can be slow to install and expensive.These systems have also been shown to reduce overall load transfer performance of the bolting system. In order to provide a higher level of corrosion protection whilst maintaining current installation practices and bolting cycle times, Minova has developed the Enduro^(TM)steel ground support range. The Enduro^(TM) range consists of standard Minova steel ground support components which have been treated with a unique coating process. The Enduro^(TM)coating has been tested in the harshest of conditions, in laboratory controlled conditions and in underground trials. It has been proven to effectively resist or completely eliminate the formation of corrosion, even in the most aggressive environments. This paper explains the process and provides the details of the laboratory and underground corrosion performance testing carried out on Enduro^(TM)ground support products. 展开更多
关键词 corrosion COATINGS Galvanised Salt spray accelerated corrosion testing
下载PDF
Bond Strength Degradation of Corrosive Reinforced Lightweight Concrete
7
作者 陈月顺 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2007年第2期354-357,共4页
The influence of reinforced bar corrosion on the bond degradation in lightweight concrete was studied. Accelerated constant current corrosion tests were performed on lightweight reinforced concrete samples, and the in... The influence of reinforced bar corrosion on the bond degradation in lightweight concrete was studied. Accelerated constant current corrosion tests were performed on lightweight reinforced concrete samples, and the influential factors, such as protective layer thickness, reinforced bar diameter and corrosive level were investigated. The constant current step method was used to measure the electric resistance of the concrete protective cover, which was used to characterize the corrosion level of the rebar. Experimental results indicated that the corrosive resistance increased with increasing the cover dimension and decreasing the reinforced bar diameter, and the rate of decrease in the specimen impedance after cracking depended on the cover dimension. A new medium was offered for the further research on the performance degradation of corrosion lightweight concrete. 展开更多
关键词 Faraday law lightweight concrete accelerated corrosion constant current step accelerated corrosion
下载PDF
Calculation of corrosion rate for reinforced concrete beams based on corrosive crack width 被引量:4
8
作者 Feng WU Jing-hai GONG Zhang ZHANG 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2014年第3期197-207,共11页
This paper deals with a correction method for corrosive crack width caused by non-uniform corrosion. Considering the corrosion cracking characteristics of a reinforced concrete structure, a correction model of corrosi... This paper deals with a correction method for corrosive crack width caused by non-uniform corrosion. Considering the corrosion cracking characteristics of a reinforced concrete structure, a correction model of corrosive crack width involving the mutual impacts between adjacent measuring points is established. The calculation model for steel bar corrosion rate for single point is obtained through quantitative analysis and accelerated corrosion tests on more than 70 reinforced cubic members. Two methods are suggested by combining two models, the correction and the corrosion calculation ones. Electrolyte accelerated cor- rosion tests on seven beams are carried out to verify these methods. The experimental results show that the ratio between the maximum corrosion rate by the indirect method and the measured average value ranges from 1.4 to 2.4, and the indirect method is shown to be an effective method for calculating the maximum corrosion rate. 展开更多
关键词 Corrosive crack width Non-uniform corrosion corrosion rate Electrolyte accelerated corrosion test Reinforced cubic beams
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部