Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized fo...Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized for preventive care over 5 years, using detailed gait function measurements with an accelerometer-based system. Methods: Seventy individuals (17 male and 53 female) of a daycare service in Tokyo participated in a weekly exercise program, meeting 1 - 2 times. The average age of the participants at the start of the program was 81.4 years. Gait function, including gait speed, stride length, root mean square (RMS) of acceleration, gait cycle time and its standard deviation, and left-right difference in stance time, was evaluated every 6 months. Results: Gait speed and stride length improved considerably within six months of starting the exercise program, confirming an initial improvement in gait function. This suggests that regular exercise programs can maintain or improve gait function even age groups that predictably have a gradual decline in gait ability due to enhanced age. In the long term, many indicators tended to approach baseline values. However, the exercise program seemingly counteracts age-related changes in gait function and maintains a certain level of function. Conclusions: While a decline in gait ability with aging is inevitable, establishing appropriate exercise habits in late-stage older individuals may contribute to long-term maintenance of gait function.展开更多
Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss ...Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss of dopamine neurons in the nigrostriatal system that leads to widespread motor symptoms such as bradykinesia, rigidity, tremor and postural instability. ET typically involves a tremor of the arms, hands or fingers. No definitive test or biomarker is yet available for PD or ET, so the rate of misdiagnosis is relatively high. As tremor is a very common feature at the onset of both diseases, it is crucial to be able to characterize it. This is made possible using acce?lerometers to quantify the tremor amplitude and frequency. In this work we aim to find tasks involving upper limb movements that are suitable to modulate both types of tremor. Four tasks were tested, differing on whether the arms moved together or alternatingly and whether loads were added. Significant differences in tremor measures were found when patients were asked to perform simultaneous rapid arms movements with loads placed on their wrists. These results may allow the design of an efficient fMRI protocol for identifying the cortical circuits responsible for the modulation of tremor.展开更多
With the recent development of digital Micro Electro Mechanical System (MEMS) sensors, the cost of monitoring and detecting seismic events in real time can be greatly reduced. Ability of MEMS accelerograph to record...With the recent development of digital Micro Electro Mechanical System (MEMS) sensors, the cost of monitoring and detecting seismic events in real time can be greatly reduced. Ability of MEMS accelerograph to record a seismic event depends upon the efficiency of triggering algorithm, apart from the sensor's sensitivity. There are several classic triggering algorithms developed to detect seismic events, ranging from basic amplitude threshold to more sophisticated pattern recognition. Algorithms based on STA/LTA are reported to be computationally efficient for real time monitoring. In this paper, we analyzed several STA/LTA algorithms to check their efficiency and suitability using data obtained from the Quake Catcher Network (network of MEMS accelerometer stations). We found that most of the STA/LTA algorithms are suitable for use with MEMS accelerometer data to accurately detect seismic events. However, the efficiency of any particular algorithm is found to be dependent on the parameter set used (i.e., window width of STA, LTA and threshold level).展开更多
Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume...Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume and anti-electromagnetic disturbance measurement of acceleration.In recent years,with the in-depth research and development of MOEMS accelerometers,the community is flourishing with the possible applications in seismic monitoring,inertial navigation,aerospace and other industrial and military fields.There have been a variety of schemes of MOEMS accelerometers,whereas the performances differ greatly due to different measurement principles and corresponding application requirements.This paper aims to address the pressing issue of the current lack of systematic review of MOEMS accelerometers.According to the optical measurement principle,we divide the MOEMS accelerometers into three categories:the geometric optics based,the wave optics based,and the new optomechanical accelerometers.Regarding the most widely studied category,the wave optics based accelerometers are further divided into four sub-categories,which is based on grating interferometric cavity,Fiber Bragg Grating(FBG),Fabry-Perot cavity,and photonic crystal,respectively.Following a brief introduction to the measurement principles,the typical performances,advantages and disadvantages as well as the potential application scenarios of all kinds of MOEMS accelerometers are discussed on the basis of typical demonstrations.This paper also presents the status and development tendency of MOEMS accelerometers to meet the ever-increasing demand for high-precision acceleration measurement.展开更多
This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron spu...This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron sputtering machine was used. Polymethyl methacrylate(PMMA) and aluminum-doped zinc oxide(AZO) were used as the insulating layer and the top electrode of the NG, respectively. The experimental results show that the ZnO thin films annealed at 150℃ exhibited the highest crystallinity among the prepared films and an optical band gap of 3.24 eV. The NG fabricated with an AZO/PMMA/ZnO/stainless steel configuration exhibited a higher output voltage than the device with an AZO/ZnO/PMMA/stainless steel configuration. In addition, the annealing temperature affected the open-circuit voltage of the NGs;the output voltage reached 3.81 V when the annealing temperature was 150℃. The open-circuit voltage of the prepared self-powered accelerometer increased linearly with acceleration. In addition, the small NG-based accelerometer, which exhibited excellent fatigue resistance, can be used for acceleration measurements of small and lightweight devices.展开更多
In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system ...In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system is of large volume, high cost, and complex structure, this approach is presented to determine the attitude based on vector space with single-antenna GPS and accelerometers in the micro inertial measurement unit (MIMU). It can provide real-time and accurate attitude information. Subsequently, the single-antenna GPS/SINS integrated navigation system is designed based on the combination of position, velocity, and attitude. Finally the semi- physical simulations of single-antenna GPS attitude determination system and single-antenna GPS/SINS integrated navigation system are carried out. The simulation results, based on measured data, show that the single-antenna GPS/SINS system can provide more accurate navigation information compared to the GPS/SINS system, based on the combination of position and velocity. Furthermore, the single-antenna GPS/SINS system is characteristic of lower cost and simpler structure. It provides the basis for the application of a single-antenna GPS/SINS integrated navigation system in a micro aerial vehicle (MAV).展开更多
The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS ac...The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS accelerometer, it can be divided into: piezoresistive, piezoelectric, capacitive, tunnel, resonant, electromagnetic, thermocouple, optical, inductive, etc. Due to its outstanding features in terms of size, quality, power consumption and reliability, MEMS sensors are used in military applications and where high environmental resistance is required. MEMS accelerometers are developing rapidly and have good application prospects. In order to make MEMS accelerometers more widely understood, the advantages of MEMS accelerometers are expounded. The research status of MEMS accelerometers is introduced, and MEMS are analyzed. The application of accelerometers in real-world environments, and the development trend of MEMS accelerometers in the future. More scholars will invest in MEMS accelerometer research, pursuing high performance, low power consumption, high precision, multi-function, and interaction. Strong MEMS accelerometers will be ubiquitous in the future.展开更多
This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was p...This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was performed through the double-difference phase, using the adjusted interferometry technique (i.e. phase residue method—PRM®). In the method, the double-difference phase of the carrier L1 is realized by using two satellites only, one was positioned at the zenith of the structure and the other satellite was positioned near the horizon. The results of the parametric adjustment of the PRM observations were finalized through software Interferometry, mathematical algorithm were applied and compared with the accelerometer. The comparison served to validate the use of GPS as a fast and reliable instrument for the preliminary monitoring of the dynamic behavior of the bridge, road artworks which are common in several countries, especially in the Brazilian road network. The data time series from the GPS and accelerometers were processed using the Wavelet. The detection of frequencies means that the combination of 100 Hz GPS receivers and the PRM allows detecting vibrations up to 5 mm. It presented significant results which were never obtained by the Fourier Transform.展开更多
MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safe...MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safety we need to calibrate MEMS accelerometers.Many authors have improved accelerometer accuracy by calculating calibration parameters,and a large number of published calibration methods have been confusing.In this context,this paper introduces these techniques and methods,analyzes and summarizes the main error models and calibration procedures,and provides useful suggestions.Finally,the content of the accelerometer calibration method needs to be overcome.展开更多
A new integrated measuring system with eight force-balance accelerometers is proposed to obtain a direct measurement of six degree-of freedom (DOF) ground motions, including three rotational and three actual transla...A new integrated measuring system with eight force-balance accelerometers is proposed to obtain a direct measurement of six degree-of freedom (DOF) ground motions, including three rotational and three actual translational acceleration components without gyroscopes. In the proposed measuring system, the relationship between the output from eight force-balance accelerometer and the six DOF motion of the measuring system under an earthquake are described by differential equations. These equations are derived from the positions and directions of the eight force-balance accelerometers in the measuring system. The third-order Runge-Kutta algorithm is used to guarantee the accuracy of the numerical calculation. All the algorithms used to compute the six DOF components of the ground motion are implemented in a real-time in Digital Signal Processor (DSP). The distortion of the measured results caused by position and direction errors of the accelerometers in the measuring system are reduced by multiplying a compensation coefficient C to the output and subtracting static zero drift from the measured results, respectively.展开更多
Physical activity is consistently associated with reduced mortality,decreased risk for non-communicable diseases,and improved mental health in observational studies.Randomized controlled trials and observational Mende...Physical activity is consistently associated with reduced mortality,decreased risk for non-communicable diseases,and improved mental health in observational studies.Randomized controlled trials and observational Mendelian randomization studies support causal links between physical activity and health outcomes.However,the scarcity of evidence from randomized controlled trials,along with their inherent challenges like exposure contrasts,healthy volunteer biases,loss to follow-up,and limited real-world dose-response data,warrants a comprehensive approach.This review advocates synthesizing insights from diverse study designs to better understand the causal relationship between physical activity,mortality risk,and other health outcomes.Additionally,it summarizes recent research since the publication of current physical activity recommendations.Novel observational studies utilizing device-measured physical activity underscore the importance of every minute of activity and suggest that all intensity levels confer health benefits,with vigorous-intensity potentially requiring lower volumes for substantial benefits.Future guidelines,informed by device-measured physical activity studies,may offer refined age-specific recommendations,emphasize vigorous-intensity physical activity,and include daily step counts as a simple,easily assessable metric using commercial wearables.展开更多
Purpose:It is aimed to assess whether school uniforms are associated with population-level gender inequalities in physical activity,and whether associations differ by school level,country/region income,and assessment ...Purpose:It is aimed to assess whether school uniforms are associated with population-level gender inequalities in physical activity,and whether associations differ by school level,country/region income,and assessment method.Methods:An ecological study design was employed.We collected data about global uniform practices using an online survey.We searched for country/region-level estimates of school-aged youth meeting physical activity guidelines from international surveillance studies.Study selection was conducted in duplicate using a systematic process,and a random sample of all data was checked to ensure extraction and pooling processes were accurate.We calculated absolute and relative gender inequalities in physical activity for each country.Linear regression examined associations between country/region-level uniform practices(binary yes/no exposure variable) and country/region-level gender inequalities in physical activity guideline compliance(absolute and relative inequalities).We investigated moderation by school level,stratified analyses by income group,and repeated primary analyses using device-measured data.Results:Pooling data from 135 countries/regions(n=1,089,852),we found no association between population-level uniform practices and gender inequalities in physical activity across all ages(absolute:β=-0.2;95% confidence interval(95%CI):-1.7 to 1.3,p=0.74;relative:β=0.1;95%CI:-0.1 to 0.2,p=0.51).Subgroup analysis suggested a positive association in primary school settings(absolute:β=4.3;95%CI:-0.0 to 8.6,p=0.05).Among high-income countries,absolute inequalities were significantly greater in countries/regions with uniform practices(N=37) compared to those without(N=48)(9.1(SD=3.6) vs.7.8 percentage points(SD=4.3)).Repeating analyses using device-measured data(n=32,130;N=24) did not alter our primary finding.From initial descriptive statistics,we found that in countries/regions where a maj ority of schools(>50%) reportedly use uniforms,there was lower compliance with physical activity guidelines among all genders(median:16.0%,interquartile range:13.2%-19.9%,N=103) compared to generally non-uniform countries/regions(median:19.5%,interquartile range:16.4%-23.5 %,N=32)(z=3.04,p=0.002).(N=countries,regions and studies repre sented;n=sample size or participants included).Conclusion:School uniforms are associated with greater gender inequalities in physical activity in primary school settings and in high-income countries.Our population-level findings warrant testing using individual-level data across contexts.展开更多
Purpose:The purpose of this scoping review was to summarize and describe the methodology and results from population-based studies of physical activity and sedentary time measured with devices in the Nordic countries(...Purpose:The purpose of this scoping review was to summarize and describe the methodology and results from population-based studies of physical activity and sedentary time measured with devices in the Nordic countries(Denmark,Finland,Iceland,Norway,and Sweden)and published in 2000 or later.Methods:A systematic search was carried out in PubMed and Web of Science in June 2023 using predefined search terms.Results:Fourteen unique research projects or surveillance studies were identified.Additionally,2 surveillance studies published by national agencies were included,resulting in a total of 16 studies for inclusion.National surveillance systems exist in Finland and Norway,with regular survey waves in school-aged children/adolescents and adults.In Denmark,recent nationally representative data have been collected in school children only.So far,Sweden has no regular national surveillance system using device-based data collection.No studies were found from Iceland.The first study was conducted in 2001 and the most recent in 2022,with most data collected from 2016 to date.Five studies included children/adole scents 6-18 years,no study included preschoolers.In total 11 studies included adults,of which 8 also covered older adults.No study focused specifically on older adults.The analytical sample size ranged from 205 to 27,890.Detailed methodology is presented,such as information on sampling strategy,device type and placement,wear protocols,and physical activity classification schemes.Levels of physical activity and sedentary time in children/adolescents,adults,and older adults across the Nordic countries are presented.Conclusion:A growing implementation of device-based population surveillance of physical activity and sedentary behavior in the Nordic countries has been identified.The variety of devices,placement,and data procedures both within and between the Nordic countries highlights the challenges when it comes to comparing study outcomes as well as the need for more standardized data collection.展开更多
Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a populat...Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a population-based prospective cohort study.Methods:Altogether,88,000 participants(mean age=62.2±7.9 years,mean±SD)were included from the UK Biobank.Sleep duration(short:<6 h/day;normal:6-8 h/day;long:>8 h/day)and PA of different intensities were measured using a wrist-won accelerometer over a 7-day period between 2013 and 2015.PA was classified according to the median or World Health Organization-recommendation:total volume of PA(high,low),moderate-to-vigorous PA(MVPA)(recommended,not recommended),and light-intensity PA(high,low).Incidence of type 2diabetes was ascertained using hospital records or death registries.Results:During a median follow-up of 7.0 years,1615 incident type 2 diabetes cases were documented.Compared with normal sleep duration,short(hazard ratio(HR)=1.21,95%confidence interval(95%CI):1.03-1.41)but not long sleep duration(HR=1.01,95%CI:0.89-1.15)was associated with excessive type 2 diabetes risk.This increased risk among short sleepers seems to be protected against by PA.Compared with normal sleepers with high or recommended PA,short sleepers with low volume of PA(HR=1.81,95%CI:1.46-2.25),not recommended(below the World Health Organization-recommended level of)MVPA(HR=1.92,95%CI:1.55-2.36),or low light-intensity PA(HR=1.49,95%CI:1.13-1.90)had a higher risk of type 2 diabetes,while short sleepers with a high volume of PA(HR=1.14,95%CI:0.88-1.49),recommended MVPA(HR=1.02,95%CI:0.71-1.48),or high light-intensity PA(HR=1.14,95%CI:0.92-1.41)did not.Conclusion:Accelerometer-measured short but not long sleep duration was associated with a higher risk of incident type 2 diabetes.A higher level of PA,regardless of intensity,potentially ameliorates this excessive risk.展开更多
The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-s...The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-state platforms.In this paper,an acceleration sensing scheme based on NV spin–strain coupling is proposed,which can effectively eliminate the influence of the stray noise field introduced by traditional mechanical schemes.Through the finite element simulation,it is found that the measurement bandwidth of this ensemble NV spin system ranges from 3 kHz to hundreds of kHz with structure√optimization.The required power is at the sub-μW level,corresponding to a noise-limited sensitivity of 6.7×10^(-5) /√Hz.Compared with other types of accelerometers,this micro-sized diamond sensor proposed here has low power consumption,exquisite sensitivity,and integration potential.This research opens a fresh perspective to realize an accelerometer with appealing comprehensive performance applied in biomechanics and inertial measurement fields.展开更多
In view of the large scientific and technical interest in the microelectromechanical system(MEMS)accelerometer sensor and the limitations of capacitive,resistive piezo,and piezoelectric methods,we focus on the measure...In view of the large scientific and technical interest in the microelectromechanical system(MEMS)accelerometer sensor and the limitations of capacitive,resistive piezo,and piezoelectric methods,we focus on the measurement of the seismic mass displacement using a novel design of the all-optical sensor(AOS).The proposed AOS consists of two waveguides and a ring resonator in a two-dimensional rod-based photonic crystal(PhC)microstructure,and a holder which connects the central rod of a nanocavity to a proof mass.The photonic band structure of the AOS is calculated with the plane-wave expansion approach for TE and TM polarization modes,and the light wave propagation inside the sensor is analyzed by solving MaxwelFs equations using the finite-difference time-domain method.The results of our simulations demonstrate that the fundamental PhC has a free spectral range of about 730 nm covering the optical communication wavelength-bands.Simulations also show that the AOS has the resonant peak of 0.8 at 1.644μm,quality factor of 3288,full width at half maximum of 0.5nm,and figure of merit of 0.97.Furthermore,for the maximum 200nm nanocavity displacements in the x-or y-direction,the resonant wavelengths shift to 1.618μm and 1.547μm,respectively.We also calculate all characteristics of the nanocavity displacement in positive and negative directions of the jc-axis and y-axis.The small area of 104.35μm^(2)and short propagation time of the AOS make it an interesting sensor for various applications,especially in the vehicle navigation systems and aviation safety tools.展开更多
Low Earth Orbit satellite on-board accelerometers play an important role in improving our understanding of thermosphere density;however,the accelerometer-derived densities are subject to accelerometer calibration erro...Low Earth Orbit satellite on-board accelerometers play an important role in improving our understanding of thermosphere density;however,the accelerometer-derived densities are subject to accelerometer calibration errors.In this study,two different dynamic calibration schemes,the accelerometer parameter-incorporated orbit fitting and precise orbit determination(POD),are investigated with the Gravity Recovery And Climate Experiment(GRACE)satellite accelerometers for thermosphere density derivation during years 2004–2007(inclusive).We show that the GRACE accelerometer parametrization can be optimized by fixing scale coefficients and estimating biases every 60 min so that the orbit fitting and POD precision can be improved from 10 cm to 2 cm in the absence of empirical acceleration compensations and as a result the integrity of calibration parameters may be reserved.The orbit-fitting scheme demonstrates similar calibration precision with respect to POD.Their bias estimates in the along-track and cross-track components exhibit an offset within 0.1%and a standard deviation(STD)less than 0.3%.Correspondingly,a bias of 2.20%and a STD of 5.75%exists between their thermosphere density estimates.The orbit-fitting and POD-derived thermosphere densities are validated through the comparison against the results published by other institution.The comparison shows that either of them can achieve a precision level at 6%.To derive thermosphere density from the rapid-increasing amount of on-board accelerometer data sets,it is suggested to take full advantage of the orbit-fitting scheme due to its high efficiency as well as high precision.展开更多
Vector accelerometer has attracted much attention for its great application potential in underground seismic signal measurement. We propose and demonstrate a novel vector accelerometer based on the three fiber Bragg g...Vector accelerometer has attracted much attention for its great application potential in underground seismic signal measurement. We propose and demonstrate a novel vector accelerometer based on the three fiber Bragg gratings(FBGs)embedded in a silicone rubber compliant cylinder at 120° distributed uniformly. The accelerometer is capable of detecting the orientation of vibration with a range of 0°–360° and the acceleration through monitoring the central wavelength shifts of three FBGs simultaneously. The experimental results show that the natural frequency of the accelerometer is about 85 Hz, and the sensitivity is 84.21 pm/g in the flat range of 20 Hz–60 Hz. Through experimental calibration, the designed accelerometer can accurately obtain vibration vector information, including vibration orientation and acceleration. In addition, the range of resonant frequency and sensitivity can be expanded by adjusting the hardness of the silicone rubber materials. Due to the characteristics of small size and orientation recognition, the accelerometer can be applied to low-frequency vibration acceleration vector measurement in narrow spaces.展开更多
With the rapid advancement of wearable devices,Human Activities Recognition(HAR)based on these devices has emerged as a prominent research field.The objective of this study is to enhance the recognition performance of...With the rapid advancement of wearable devices,Human Activities Recognition(HAR)based on these devices has emerged as a prominent research field.The objective of this study is to enhance the recognition performance of HAR by proposing an LSTM-1DCNN recognition algorithm that utilizes a single triaxial accelerometer.This algorithm comprises two branches:one branch consists of a Long and Short-Term Memory Network(LSTM),while the other parallel branch incorporates a one-dimensional Convolutional Neural Network(1DCNN).The parallel architecture of LSTM-1DCNN initially extracts spatial and temporal features from the accelerometer data separately,which are then concatenated and fed into a fully connected neural network for information fusion.In the LSTM-1DCNN architecture,the 1DCNN branch primarily focuses on extracting spatial features during convolution operations,whereas the LSTM branch mainly captures temporal features.Nine sets of accelerometer data from five publicly available HAR datasets are employed for training and evaluation purposes.The performance of the proposed LSTM-1DCNN model is compared with five other HAR algorithms including Decision Tree,Random Forest,Support Vector Machine,1DCNN,and LSTM on these five public datasets.Experimental results demonstrate that the F1-score achieved by the proposed LSTM-1DCNN ranges from 90.36%to 99.68%,with a mean value of 96.22%and standard deviation of 0.03 across all evaluated metrics on these five public datasets-outperforming other existing HAR algorithms significantly in terms of evaluation metrics used in this study.Finally the proposed LSTM-1DCNN is validated in real-world applications by collecting acceleration data of seven human activities for training and testing purposes.Subsequently,the trained HAR algorithm is deployed on Android phones to evaluate its performance.Experimental results demonstrate that the proposed LSTM-1DCNN algorithm achieves an impressive F1-score of 97.67%on our self-built dataset.In conclusion,the fusion of temporal and spatial information in the measured data contributes to the excellent HAR performance and robustness exhibited by the proposed 1DCNN-LSTM architecture.展开更多
Background: Wearable monitors(WMs) are used to estimate the time spent in sedentary behaviors(SBs) and light-intensity physical activities(LPAs) and their associated energy cost; however, the accuracy of WMs in measur...Background: Wearable monitors(WMs) are used to estimate the time spent in sedentary behaviors(SBs) and light-intensity physical activities(LPAs) and their associated energy cost; however, the accuracy of WMs in measuring behaviors on the lower end of the intensity spectrum is unclear. The aim of this study was to assess the validity of 3 WMs(Acti Graph GT3X+; activ PAL, and Sense Wear 2) in estimating the intensity of SB and LPA in adults as compared with the criterion measure of oxygen uptake(VO_2) measured by indirect calorimetry.Methods: Sixteen participants(age: 25.38 ± 8.58 years) wore the ActiG raph GT3X+, activP AL, and SenseW ear 2 devices during 7 sedentary-to-light activities. VO_2(mL/kg/min) was estimated by means of a portable gas analyzer, Oxycon Mobile(Carefusion, Yorba Linda, CA, USA). All data were transformed into metabolic equivalents and analyzed using mean percentage error, equivalence plots, Bland-Altman plots, kappa statistics, and sensitivity/specificity.Results: Mean percentage error was lowest for the activ PAL for SB(14.9%) and LPA(9.3%) compared with other WMs, which were >21.2%.None of the WMs fell within the equivalency range of ±10% of the criterion mean value. Bland-Altman plots revealed narrower levels of agreement with all WMs for SB than for LPA. Kappa statistics were low for all WMs, and sensitivity and specificity varied by WM type.Conclusion: None of the WMs tested in this study were equivalent with the criterion measure(VO_2) in estimating sedentary-to-light activities;however, the activ PAL had greater overall accuracy in measuring SB and LPA than did the Acti Graph and Sense Wear 2 monitors.展开更多
文摘Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized for preventive care over 5 years, using detailed gait function measurements with an accelerometer-based system. Methods: Seventy individuals (17 male and 53 female) of a daycare service in Tokyo participated in a weekly exercise program, meeting 1 - 2 times. The average age of the participants at the start of the program was 81.4 years. Gait function, including gait speed, stride length, root mean square (RMS) of acceleration, gait cycle time and its standard deviation, and left-right difference in stance time, was evaluated every 6 months. Results: Gait speed and stride length improved considerably within six months of starting the exercise program, confirming an initial improvement in gait function. This suggests that regular exercise programs can maintain or improve gait function even age groups that predictably have a gradual decline in gait ability due to enhanced age. In the long term, many indicators tended to approach baseline values. However, the exercise program seemingly counteracts age-related changes in gait function and maintains a certain level of function. Conclusions: While a decline in gait ability with aging is inevitable, establishing appropriate exercise habits in late-stage older individuals may contribute to long-term maintenance of gait function.
文摘Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss of dopamine neurons in the nigrostriatal system that leads to widespread motor symptoms such as bradykinesia, rigidity, tremor and postural instability. ET typically involves a tremor of the arms, hands or fingers. No definitive test or biomarker is yet available for PD or ET, so the rate of misdiagnosis is relatively high. As tremor is a very common feature at the onset of both diseases, it is crucial to be able to characterize it. This is made possible using acce?lerometers to quantify the tremor amplitude and frequency. In this work we aim to find tasks involving upper limb movements that are suitable to modulate both types of tremor. Four tasks were tested, differing on whether the arms moved together or alternatingly and whether loads were added. Significant differences in tremor measures were found when patients were asked to perform simultaneous rapid arms movements with loads placed on their wrists. These results may allow the design of an efficient fMRI protocol for identifying the cortical circuits responsible for the modulation of tremor.
基金IIT Roorkee under the Faculty Initiation Grant No.100556
文摘With the recent development of digital Micro Electro Mechanical System (MEMS) sensors, the cost of monitoring and detecting seismic events in real time can be greatly reduced. Ability of MEMS accelerograph to record a seismic event depends upon the efficiency of triggering algorithm, apart from the sensor's sensitivity. There are several classic triggering algorithms developed to detect seismic events, ranging from basic amplitude threshold to more sophisticated pattern recognition. Algorithms based on STA/LTA are reported to be computationally efficient for real time monitoring. In this paper, we analyzed several STA/LTA algorithms to check their efficiency and suitability using data obtained from the Quake Catcher Network (network of MEMS accelerometer stations). We found that most of the STA/LTA algorithms are suitable for use with MEMS accelerometer data to accurately detect seismic events. However, the efficiency of any particular algorithm is found to be dependent on the parameter set used (i.e., window width of STA, LTA and threshold level).
基金supports from National Natural Science Foundation of China(No.62004166)Fundamental Research Funds for the Central Universities(No.31020190QD027)+2 种基金Natural Science Basic Research Program of Shaanxi(Program No.2020JQ-199)China National Postdoctoral Program for Innovative Talents(No.BX20200279)Key Research and Development Program of Shaanxi Province(2020GXLH-Z-027,2020ZDLGY04-08).
文摘Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume and anti-electromagnetic disturbance measurement of acceleration.In recent years,with the in-depth research and development of MOEMS accelerometers,the community is flourishing with the possible applications in seismic monitoring,inertial navigation,aerospace and other industrial and military fields.There have been a variety of schemes of MOEMS accelerometers,whereas the performances differ greatly due to different measurement principles and corresponding application requirements.This paper aims to address the pressing issue of the current lack of systematic review of MOEMS accelerometers.According to the optical measurement principle,we divide the MOEMS accelerometers into three categories:the geometric optics based,the wave optics based,and the new optomechanical accelerometers.Regarding the most widely studied category,the wave optics based accelerometers are further divided into four sub-categories,which is based on grating interferometric cavity,Fiber Bragg Grating(FBG),Fabry-Perot cavity,and photonic crystal,respectively.Following a brief introduction to the measurement principles,the typical performances,advantages and disadvantages as well as the potential application scenarios of all kinds of MOEMS accelerometers are discussed on the basis of typical demonstrations.This paper also presents the status and development tendency of MOEMS accelerometers to meet the ever-increasing demand for high-precision acceleration measurement.
基金supported by the National Natural Science Foundation of China (No. 61671017)Key Project of Excellent Youth Talent Support Program in Colleges and Universities of Anhui Province (No. gxyqZD2018004)+1 种基金Provincial Natural Science Foundation of Anhui Higher Education Institution of China (No. KJ2016A787)Anhui Provincial Natural Science Foundation of China (No. 1508085ME72)
文摘This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron sputtering machine was used. Polymethyl methacrylate(PMMA) and aluminum-doped zinc oxide(AZO) were used as the insulating layer and the top electrode of the NG, respectively. The experimental results show that the ZnO thin films annealed at 150℃ exhibited the highest crystallinity among the prepared films and an optical band gap of 3.24 eV. The NG fabricated with an AZO/PMMA/ZnO/stainless steel configuration exhibited a higher output voltage than the device with an AZO/ZnO/PMMA/stainless steel configuration. In addition, the annealing temperature affected the open-circuit voltage of the NGs;the output voltage reached 3.81 V when the annealing temperature was 150℃. The open-circuit voltage of the prepared self-powered accelerometer increased linearly with acceleration. In addition, the small NG-based accelerometer, which exhibited excellent fatigue resistance, can be used for acceleration measurements of small and lightweight devices.
基金the Astronautic Technology Foundation (HTZC0405)
文摘In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system is of large volume, high cost, and complex structure, this approach is presented to determine the attitude based on vector space with single-antenna GPS and accelerometers in the micro inertial measurement unit (MIMU). It can provide real-time and accurate attitude information. Subsequently, the single-antenna GPS/SINS integrated navigation system is designed based on the combination of position, velocity, and attitude. Finally the semi- physical simulations of single-antenna GPS attitude determination system and single-antenna GPS/SINS integrated navigation system are carried out. The simulation results, based on measured data, show that the single-antenna GPS/SINS system can provide more accurate navigation information compared to the GPS/SINS system, based on the combination of position and velocity. Furthermore, the single-antenna GPS/SINS system is characteristic of lower cost and simpler structure. It provides the basis for the application of a single-antenna GPS/SINS integrated navigation system in a micro aerial vehicle (MAV).
文摘The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS accelerometer, it can be divided into: piezoresistive, piezoelectric, capacitive, tunnel, resonant, electromagnetic, thermocouple, optical, inductive, etc. Due to its outstanding features in terms of size, quality, power consumption and reliability, MEMS sensors are used in military applications and where high environmental resistance is required. MEMS accelerometers are developing rapidly and have good application prospects. In order to make MEMS accelerometers more widely understood, the advantages of MEMS accelerometers are expounded. The research status of MEMS accelerometers is introduced, and MEMS are analyzed. The application of accelerometers in real-world environments, and the development trend of MEMS accelerometers in the future. More scholars will invest in MEMS accelerometer research, pursuing high performance, low power consumption, high precision, multi-function, and interaction. Strong MEMS accelerometers will be ubiquitous in the future.
文摘This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was performed through the double-difference phase, using the adjusted interferometry technique (i.e. phase residue method—PRM®). In the method, the double-difference phase of the carrier L1 is realized by using two satellites only, one was positioned at the zenith of the structure and the other satellite was positioned near the horizon. The results of the parametric adjustment of the PRM observations were finalized through software Interferometry, mathematical algorithm were applied and compared with the accelerometer. The comparison served to validate the use of GPS as a fast and reliable instrument for the preliminary monitoring of the dynamic behavior of the bridge, road artworks which are common in several countries, especially in the Brazilian road network. The data time series from the GPS and accelerometers were processed using the Wavelet. The detection of frequencies means that the combination of 100 Hz GPS receivers and the PRM allows detecting vibrations up to 5 mm. It presented significant results which were never obtained by the Fourier Transform.
基金This work has received funding from 5150 Spring Specialists(05492018012)the European Union Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant agreement No.701697,Major Program of the National Social Science Fund of China(Grant No.17ZDA092)+1 种基金Basic Research Programs(Natural Science Foundation)of Jiangsu Province(BK20180794)333 High-Level Talent Cultivation Project of Jiangsu Province(BRA2018332)and the PAPD fund.
文摘MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safety we need to calibrate MEMS accelerometers.Many authors have improved accelerometer accuracy by calculating calibration parameters,and a large number of published calibration methods have been confusing.In this context,this paper introduces these techniques and methods,analyzes and summarizes the main error models and calibration procedures,and provides useful suggestions.Finally,the content of the accelerometer calibration method needs to be overcome.
基金supported by the National Natural Science Foundation of China under Grant No.50378086the China Seismology United Foundation under Grant No.104139.
文摘A new integrated measuring system with eight force-balance accelerometers is proposed to obtain a direct measurement of six degree-of freedom (DOF) ground motions, including three rotational and three actual translational acceleration components without gyroscopes. In the proposed measuring system, the relationship between the output from eight force-balance accelerometer and the six DOF motion of the measuring system under an earthquake are described by differential equations. These equations are derived from the positions and directions of the eight force-balance accelerometers in the measuring system. The third-order Runge-Kutta algorithm is used to guarantee the accuracy of the numerical calculation. All the algorithms used to compute the six DOF components of the ground motion are implemented in a real-time in Digital Signal Processor (DSP). The distortion of the measured results caused by position and direction errors of the accelerometers in the measuring system are reduced by multiplying a compensation coefficient C to the output and subtracting static zero drift from the measured results, respectively.
文摘Physical activity is consistently associated with reduced mortality,decreased risk for non-communicable diseases,and improved mental health in observational studies.Randomized controlled trials and observational Mendelian randomization studies support causal links between physical activity and health outcomes.However,the scarcity of evidence from randomized controlled trials,along with their inherent challenges like exposure contrasts,healthy volunteer biases,loss to follow-up,and limited real-world dose-response data,warrants a comprehensive approach.This review advocates synthesizing insights from diverse study designs to better understand the causal relationship between physical activity,mortality risk,and other health outcomes.Additionally,it summarizes recent research since the publication of current physical activity recommendations.Novel observational studies utilizing device-measured physical activity underscore the importance of every minute of activity and suggest that all intensity levels confer health benefits,with vigorous-intensity potentially requiring lower volumes for substantial benefits.Future guidelines,informed by device-measured physical activity studies,may offer refined age-specific recommendations,emphasize vigorous-intensity physical activity,and include daily step counts as a simple,easily assessable metric using commercial wearables.
基金supported by the Economic and Social Research Council(ES/P000738/1)the Medical Research Council(MC_UU_00006/5)the University of Cambridge,and the National Health and Medical Research Council(GS2000053).
文摘Purpose:It is aimed to assess whether school uniforms are associated with population-level gender inequalities in physical activity,and whether associations differ by school level,country/region income,and assessment method.Methods:An ecological study design was employed.We collected data about global uniform practices using an online survey.We searched for country/region-level estimates of school-aged youth meeting physical activity guidelines from international surveillance studies.Study selection was conducted in duplicate using a systematic process,and a random sample of all data was checked to ensure extraction and pooling processes were accurate.We calculated absolute and relative gender inequalities in physical activity for each country.Linear regression examined associations between country/region-level uniform practices(binary yes/no exposure variable) and country/region-level gender inequalities in physical activity guideline compliance(absolute and relative inequalities).We investigated moderation by school level,stratified analyses by income group,and repeated primary analyses using device-measured data.Results:Pooling data from 135 countries/regions(n=1,089,852),we found no association between population-level uniform practices and gender inequalities in physical activity across all ages(absolute:β=-0.2;95% confidence interval(95%CI):-1.7 to 1.3,p=0.74;relative:β=0.1;95%CI:-0.1 to 0.2,p=0.51).Subgroup analysis suggested a positive association in primary school settings(absolute:β=4.3;95%CI:-0.0 to 8.6,p=0.05).Among high-income countries,absolute inequalities were significantly greater in countries/regions with uniform practices(N=37) compared to those without(N=48)(9.1(SD=3.6) vs.7.8 percentage points(SD=4.3)).Repeating analyses using device-measured data(n=32,130;N=24) did not alter our primary finding.From initial descriptive statistics,we found that in countries/regions where a maj ority of schools(>50%) reportedly use uniforms,there was lower compliance with physical activity guidelines among all genders(median:16.0%,interquartile range:13.2%-19.9%,N=103) compared to generally non-uniform countries/regions(median:19.5%,interquartile range:16.4%-23.5 %,N=32)(z=3.04,p=0.002).(N=countries,regions and studies repre sented;n=sample size or participants included).Conclusion:School uniforms are associated with greater gender inequalities in physical activity in primary school settings and in high-income countries.Our population-level findings warrant testing using individual-level data across contexts.
文摘Purpose:The purpose of this scoping review was to summarize and describe the methodology and results from population-based studies of physical activity and sedentary time measured with devices in the Nordic countries(Denmark,Finland,Iceland,Norway,and Sweden)and published in 2000 or later.Methods:A systematic search was carried out in PubMed and Web of Science in June 2023 using predefined search terms.Results:Fourteen unique research projects or surveillance studies were identified.Additionally,2 surveillance studies published by national agencies were included,resulting in a total of 16 studies for inclusion.National surveillance systems exist in Finland and Norway,with regular survey waves in school-aged children/adolescents and adults.In Denmark,recent nationally representative data have been collected in school children only.So far,Sweden has no regular national surveillance system using device-based data collection.No studies were found from Iceland.The first study was conducted in 2001 and the most recent in 2022,with most data collected from 2016 to date.Five studies included children/adole scents 6-18 years,no study included preschoolers.In total 11 studies included adults,of which 8 also covered older adults.No study focused specifically on older adults.The analytical sample size ranged from 205 to 27,890.Detailed methodology is presented,such as information on sampling strategy,device type and placement,wear protocols,and physical activity classification schemes.Levels of physical activity and sedentary time in children/adolescents,adults,and older adults across the Nordic countries are presented.Conclusion:A growing implementation of device-based population surveillance of physical activity and sedentary behavior in the Nordic countries has been identified.The variety of devices,placement,and data procedures both within and between the Nordic countries highlights the challenges when it comes to comparing study outcomes as well as the need for more standardized data collection.
基金supported by the National Key R&D Program of China(2021YFC2501500)National Natural Science Foundation of China(82171476)。
文摘Purpose:The aim of the current study was to investigate the association of accelerometer-measured sleep duration and different intensities of physical activity(PA)with the risk of incident type 2 diabetes in a population-based prospective cohort study.Methods:Altogether,88,000 participants(mean age=62.2±7.9 years,mean±SD)were included from the UK Biobank.Sleep duration(short:<6 h/day;normal:6-8 h/day;long:>8 h/day)and PA of different intensities were measured using a wrist-won accelerometer over a 7-day period between 2013 and 2015.PA was classified according to the median or World Health Organization-recommendation:total volume of PA(high,low),moderate-to-vigorous PA(MVPA)(recommended,not recommended),and light-intensity PA(high,low).Incidence of type 2diabetes was ascertained using hospital records or death registries.Results:During a median follow-up of 7.0 years,1615 incident type 2 diabetes cases were documented.Compared with normal sleep duration,short(hazard ratio(HR)=1.21,95%confidence interval(95%CI):1.03-1.41)but not long sleep duration(HR=1.01,95%CI:0.89-1.15)was associated with excessive type 2 diabetes risk.This increased risk among short sleepers seems to be protected against by PA.Compared with normal sleepers with high or recommended PA,short sleepers with low volume of PA(HR=1.81,95%CI:1.46-2.25),not recommended(below the World Health Organization-recommended level of)MVPA(HR=1.92,95%CI:1.55-2.36),or low light-intensity PA(HR=1.49,95%CI:1.13-1.90)had a higher risk of type 2 diabetes,while short sleepers with a high volume of PA(HR=1.14,95%CI:0.88-1.49),recommended MVPA(HR=1.02,95%CI:0.71-1.48),or high light-intensity PA(HR=1.14,95%CI:0.92-1.41)did not.Conclusion:Accelerometer-measured short but not long sleep duration was associated with a higher risk of incident type 2 diabetes.A higher level of PA,regardless of intensity,potentially ameliorates this excessive risk.
基金Project supported by the National Natural Science Foundation of China (Grant No.62071118)the Primary Research & Development Plan of Jiangsu Province (Grant No.BE2021004-3)。
文摘The nitrogen-vacancy (NV) center quantum systems have emerged as versatile tools in the field of precision measurement because of their high sensitivity in spin state detection and miniaturization potential as solid-state platforms.In this paper,an acceleration sensing scheme based on NV spin–strain coupling is proposed,which can effectively eliminate the influence of the stray noise field introduced by traditional mechanical schemes.Through the finite element simulation,it is found that the measurement bandwidth of this ensemble NV spin system ranges from 3 kHz to hundreds of kHz with structure√optimization.The required power is at the sub-μW level,corresponding to a noise-limited sensitivity of 6.7×10^(-5) /√Hz.Compared with other types of accelerometers,this micro-sized diamond sensor proposed here has low power consumption,exquisite sensitivity,and integration potential.This research opens a fresh perspective to realize an accelerometer with appealing comprehensive performance applied in biomechanics and inertial measurement fields.
文摘In view of the large scientific and technical interest in the microelectromechanical system(MEMS)accelerometer sensor and the limitations of capacitive,resistive piezo,and piezoelectric methods,we focus on the measurement of the seismic mass displacement using a novel design of the all-optical sensor(AOS).The proposed AOS consists of two waveguides and a ring resonator in a two-dimensional rod-based photonic crystal(PhC)microstructure,and a holder which connects the central rod of a nanocavity to a proof mass.The photonic band structure of the AOS is calculated with the plane-wave expansion approach for TE and TM polarization modes,and the light wave propagation inside the sensor is analyzed by solving MaxwelFs equations using the finite-difference time-domain method.The results of our simulations demonstrate that the fundamental PhC has a free spectral range of about 730 nm covering the optical communication wavelength-bands.Simulations also show that the AOS has the resonant peak of 0.8 at 1.644μm,quality factor of 3288,full width at half maximum of 0.5nm,and figure of merit of 0.97.Furthermore,for the maximum 200nm nanocavity displacements in the x-or y-direction,the resonant wavelengths shift to 1.618μm and 1.547μm,respectively.We also calculate all characteristics of the nanocavity displacement in positive and negative directions of the jc-axis and y-axis.The small area of 104.35μm^(2)and short propagation time of the AOS make it an interesting sensor for various applications,especially in the vehicle navigation systems and aviation safety tools.
基金the National Natural Science Foundation[grant numbers 42004020,42074032,41931075 and 42030109]National Defense Key Laboratory of Aerospace Flight Dynamics technology(grant number 6142210190101)+2 种基金China Postdoctoral Science Foundation[grant number 2021M692460]the Fundamental Research Funds for the Central Universities[grant number 2042021kf0060]Wuhan Science and Technology Bureau[grant number 2019010701011391].
文摘Low Earth Orbit satellite on-board accelerometers play an important role in improving our understanding of thermosphere density;however,the accelerometer-derived densities are subject to accelerometer calibration errors.In this study,two different dynamic calibration schemes,the accelerometer parameter-incorporated orbit fitting and precise orbit determination(POD),are investigated with the Gravity Recovery And Climate Experiment(GRACE)satellite accelerometers for thermosphere density derivation during years 2004–2007(inclusive).We show that the GRACE accelerometer parametrization can be optimized by fixing scale coefficients and estimating biases every 60 min so that the orbit fitting and POD precision can be improved from 10 cm to 2 cm in the absence of empirical acceleration compensations and as a result the integrity of calibration parameters may be reserved.The orbit-fitting scheme demonstrates similar calibration precision with respect to POD.Their bias estimates in the along-track and cross-track components exhibit an offset within 0.1%and a standard deviation(STD)less than 0.3%.Correspondingly,a bias of 2.20%and a STD of 5.75%exists between their thermosphere density estimates.The orbit-fitting and POD-derived thermosphere densities are validated through the comparison against the results published by other institution.The comparison shows that either of them can achieve a precision level at 6%.To derive thermosphere density from the rapid-increasing amount of on-board accelerometer data sets,it is suggested to take full advantage of the orbit-fitting scheme due to its high efficiency as well as high precision.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 61927812, 61735014, and 62105261)。
文摘Vector accelerometer has attracted much attention for its great application potential in underground seismic signal measurement. We propose and demonstrate a novel vector accelerometer based on the three fiber Bragg gratings(FBGs)embedded in a silicone rubber compliant cylinder at 120° distributed uniformly. The accelerometer is capable of detecting the orientation of vibration with a range of 0°–360° and the acceleration through monitoring the central wavelength shifts of three FBGs simultaneously. The experimental results show that the natural frequency of the accelerometer is about 85 Hz, and the sensitivity is 84.21 pm/g in the flat range of 20 Hz–60 Hz. Through experimental calibration, the designed accelerometer can accurately obtain vibration vector information, including vibration orientation and acceleration. In addition, the range of resonant frequency and sensitivity can be expanded by adjusting the hardness of the silicone rubber materials. Due to the characteristics of small size and orientation recognition, the accelerometer can be applied to low-frequency vibration acceleration vector measurement in narrow spaces.
基金supported by the Guangxi University of Science and Technology,Liuzhou,China,sponsored by the Researchers Supporting Project(No.XiaoKeBo21Z27,The Construction of Electronic Information Team supported by Artificial Intelligence Theory and Three-dimensional Visual Technology,Yuesheng Zhao)supported by the 2022 Laboratory Fund Project of the Key Laboratory of Space-Based Integrated Information System(No.SpaceInfoNet20221120,Research on the Key Technologies of Intelligent Spatiotemporal Data Engine Based on Space-Based Information Network,Yuesheng Zhao)supported by the 2023 Guangxi University Young and Middle-Aged Teachers’Basic Scientific Research Ability Improvement Project(No.2023KY0352,Research on the Recognition of Psychological Abnormalities in College Students Based on the Fusion of Pulse and EEG Techniques,Yutong Luo).
文摘With the rapid advancement of wearable devices,Human Activities Recognition(HAR)based on these devices has emerged as a prominent research field.The objective of this study is to enhance the recognition performance of HAR by proposing an LSTM-1DCNN recognition algorithm that utilizes a single triaxial accelerometer.This algorithm comprises two branches:one branch consists of a Long and Short-Term Memory Network(LSTM),while the other parallel branch incorporates a one-dimensional Convolutional Neural Network(1DCNN).The parallel architecture of LSTM-1DCNN initially extracts spatial and temporal features from the accelerometer data separately,which are then concatenated and fed into a fully connected neural network for information fusion.In the LSTM-1DCNN architecture,the 1DCNN branch primarily focuses on extracting spatial features during convolution operations,whereas the LSTM branch mainly captures temporal features.Nine sets of accelerometer data from five publicly available HAR datasets are employed for training and evaluation purposes.The performance of the proposed LSTM-1DCNN model is compared with five other HAR algorithms including Decision Tree,Random Forest,Support Vector Machine,1DCNN,and LSTM on these five public datasets.Experimental results demonstrate that the F1-score achieved by the proposed LSTM-1DCNN ranges from 90.36%to 99.68%,with a mean value of 96.22%and standard deviation of 0.03 across all evaluated metrics on these five public datasets-outperforming other existing HAR algorithms significantly in terms of evaluation metrics used in this study.Finally the proposed LSTM-1DCNN is validated in real-world applications by collecting acceleration data of seven human activities for training and testing purposes.Subsequently,the trained HAR algorithm is deployed on Android phones to evaluate its performance.Experimental results demonstrate that the proposed LSTM-1DCNN algorithm achieves an impressive F1-score of 97.67%on our self-built dataset.In conclusion,the fusion of temporal and spatial information in the measured data contributes to the excellent HAR performance and robustness exhibited by the proposed 1DCNN-LSTM architecture.
文摘Background: Wearable monitors(WMs) are used to estimate the time spent in sedentary behaviors(SBs) and light-intensity physical activities(LPAs) and their associated energy cost; however, the accuracy of WMs in measuring behaviors on the lower end of the intensity spectrum is unclear. The aim of this study was to assess the validity of 3 WMs(Acti Graph GT3X+; activ PAL, and Sense Wear 2) in estimating the intensity of SB and LPA in adults as compared with the criterion measure of oxygen uptake(VO_2) measured by indirect calorimetry.Methods: Sixteen participants(age: 25.38 ± 8.58 years) wore the ActiG raph GT3X+, activP AL, and SenseW ear 2 devices during 7 sedentary-to-light activities. VO_2(mL/kg/min) was estimated by means of a portable gas analyzer, Oxycon Mobile(Carefusion, Yorba Linda, CA, USA). All data were transformed into metabolic equivalents and analyzed using mean percentage error, equivalence plots, Bland-Altman plots, kappa statistics, and sensitivity/specificity.Results: Mean percentage error was lowest for the activ PAL for SB(14.9%) and LPA(9.3%) compared with other WMs, which were >21.2%.None of the WMs fell within the equivalency range of ±10% of the criterion mean value. Bland-Altman plots revealed narrower levels of agreement with all WMs for SB than for LPA. Kappa statistics were low for all WMs, and sensitivity and specificity varied by WM type.Conclusion: None of the WMs tested in this study were equivalent with the criterion measure(VO_2) in estimating sedentary-to-light activities;however, the activ PAL had greater overall accuracy in measuring SB and LPA than did the Acti Graph and Sense Wear 2 monitors.