期刊文献+
共找到3,550篇文章
< 1 2 178 >
每页显示 20 50 100
Trajectory of Walking Function in Late-Stage Older Individuals Managed with a Regular Exercise Program: A 5-Year Longitudinal Tracking with an IoT Gait Analysis System Using Accelerometers
1
作者 Taisuke Ito 《Open Journal of Therapy and Rehabilitation》 2024年第2期174-184,共11页
Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized fo... Purpose: This study focused on maintaining and improving the walking function of late-stage older individuals while longitudinally tracking the effects of regular exercise programs in a day-care service specialized for preventive care over 5 years, using detailed gait function measurements with an accelerometer-based system. Methods: Seventy individuals (17 male and 53 female) of a daycare service in Tokyo participated in a weekly exercise program, meeting 1 - 2 times. The average age of the participants at the start of the program was 81.4 years. Gait function, including gait speed, stride length, root mean square (RMS) of acceleration, gait cycle time and its standard deviation, and left-right difference in stance time, was evaluated every 6 months. Results: Gait speed and stride length improved considerably within six months of starting the exercise program, confirming an initial improvement in gait function. This suggests that regular exercise programs can maintain or improve gait function even age groups that predictably have a gradual decline in gait ability due to enhanced age. In the long term, many indicators tended to approach baseline values. However, the exercise program seemingly counteracts age-related changes in gait function and maintains a certain level of function. Conclusions: While a decline in gait ability with aging is inevitable, establishing appropriate exercise habits in late-stage older individuals may contribute to long-term maintenance of gait function. 展开更多
关键词 Late-Stage Elderly Exercise Gait Function ACCELEROMETER IoT-Based Gait Analysis Device
下载PDF
ATTITUDE MEASUREMENT ON HIGH-SPINNING PROJECTILE USING MAGNETIC SENSORS AND ACCELEROMETERS 被引量:5
2
作者 李玎 卜雄洙 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2008年第2期106-112,共7页
In allusion to the limitations of the traditional attitude measurement system consisting of a three-axis magnetic sensor and two accelerometers on high-spinning projectile, a new scheme comprised of two magnetic senso... In allusion to the limitations of the traditional attitude measurement system consisting of a three-axis magnetic sensor and two accelerometers on high-spinning projectile, a new scheme comprised of two magnetic sensors and two accelerometers installed in a particular way is given. The configuration of the sensors is described. The calculation method and the mathematical model of the projectile attitude based on the sensor configuration are discussed. The basic calculation method including the Magsonde Window, the proof of the ratios of maximums and minimums and the calculation of the attitude angles are analyzed in theory. Finally, the system is simulated under the given conditions. The simulation result indicates that the estimated attitude angles are in agreement with the true attitude angles. 展开更多
关键词 PROJECTILE MAGNETOMETERS accelerometers attitude solution digital simulation
下载PDF
System-Level Modeling and Simulation of Force-Balance MEMS Accelerometers 被引量:1
3
作者 张宇峰 刘晓为 陈伟平 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2008年第5期917-922,共6页
This paper presents two approaches for system-level simulation of force-balance accelerometers. The derivation of the system-level model is elaborated and simulation results are obtained from the implementation of tho... This paper presents two approaches for system-level simulation of force-balance accelerometers. The derivation of the system-level model is elaborated and simulation results are obtained from the implementation of those strategies on the fabricated silicon force-balance MEMS accelerometer. The mathematical model presented is implemented in VHDL- AMS and SIMULINK TM,respectively. The simulation results from the two approaches are compared and show a slight difference. Using VHDL-AMS is flexible,reusable,and more accurate. But there is not a mature solver developed for the language and this approach takes more time, while the simulation model can be easily built and quickly evaluated using SIMULINK. 展开更多
关键词 MEMS force-balance accelerometers system-level simulation mathematical model
下载PDF
Review of micromachined optical accelerometers:from mg to sub-μg 被引量:14
4
作者 Qianbo Lu Yinan Wang +3 位作者 Xiaoxu Wang Yuan Yao Xuewen Wang Wei Huang 《Opto-Electronic Advances》 SCIE 2021年第3期1-24,共24页
Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume... Micro-Opto-Electro-Mechanical Systems(MOEMS)accelerometer is a new type of accelerometer which combines the merits of optical measurement and Micro-Electro-Mechanical Systems(MEMS)to enable high precision,small volume and anti-electromagnetic disturbance measurement of acceleration.In recent years,with the in-depth research and development of MOEMS accelerometers,the community is flourishing with the possible applications in seismic monitoring,inertial navigation,aerospace and other industrial and military fields.There have been a variety of schemes of MOEMS accelerometers,whereas the performances differ greatly due to different measurement principles and corresponding application requirements.This paper aims to address the pressing issue of the current lack of systematic review of MOEMS accelerometers.According to the optical measurement principle,we divide the MOEMS accelerometers into three categories:the geometric optics based,the wave optics based,and the new optomechanical accelerometers.Regarding the most widely studied category,the wave optics based accelerometers are further divided into four sub-categories,which is based on grating interferometric cavity,Fiber Bragg Grating(FBG),Fabry-Perot cavity,and photonic crystal,respectively.Following a brief introduction to the measurement principles,the typical performances,advantages and disadvantages as well as the potential application scenarios of all kinds of MOEMS accelerometers are discussed on the basis of typical demonstrations.This paper also presents the status and development tendency of MOEMS accelerometers to meet the ever-increasing demand for high-precision acceleration measurement. 展开更多
关键词 ACCELEROMETER Micro-Opto-Electro-Mechanical Systems(MOEMS) integrated optics accelerometer review
下载PDF
Design and application of single-antenna GPS/accelerometers attitude determination system 被引量:4
5
作者 He Jie Huang Xianlin Wang Guofeng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第2期220-227,共8页
In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system ... In view of the problem that the current single-antenna GPS attitude determination system can only determine the body attitude when the sideslip angle is zero and the multiantenna GPS/SINS integrated navigation system is of large volume, high cost, and complex structure, this approach is presented to determine the attitude based on vector space with single-antenna GPS and accelerometers in the micro inertial measurement unit (MIMU). It can provide real-time and accurate attitude information. Subsequently, the single-antenna GPS/SINS integrated navigation system is designed based on the combination of position, velocity, and attitude. Finally the semi- physical simulations of single-antenna GPS attitude determination system and single-antenna GPS/SINS integrated navigation system are carried out. The simulation results, based on measured data, show that the single-antenna GPS/SINS system can provide more accurate navigation information compared to the GPS/SINS system, based on the combination of position and velocity. Furthermore, the single-antenna GPS/SINS system is characteristic of lower cost and simpler structure. It provides the basis for the application of a single-antenna GPS/SINS integrated navigation system in a micro aerial vehicle (MAV). 展开更多
关键词 single-antenna GPS attitude determination vector space ACCELEROMETER integrated navigation MAV.
下载PDF
Effect of annealing temperature on the microstructure and optoelectrical properties of ZnO thin films and their application in self-powered accelerometers 被引量:2
6
作者 Xiao-zhou Zhang Yan-ping Xia +3 位作者 Xing Liu Yi-ming Zhong Hai-bo Zhao Pei-hong Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2019年第9期1186-1193,共8页
This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron spu... This paper reports a piezoelectric nanogenerator(NG) with a thickness of approximately 80 μm for miniaturized self-powered acceleration sensors. To deposit the piezoelectric zinc oxide(ZnO) thin film, a magnetron sputtering machine was used. Polymethyl methacrylate(PMMA) and aluminum-doped zinc oxide(AZO) were used as the insulating layer and the top electrode of the NG, respectively. The experimental results show that the ZnO thin films annealed at 150℃ exhibited the highest crystallinity among the prepared films and an optical band gap of 3.24 eV. The NG fabricated with an AZO/PMMA/ZnO/stainless steel configuration exhibited a higher output voltage than the device with an AZO/ZnO/PMMA/stainless steel configuration. In addition, the annealing temperature affected the open-circuit voltage of the NGs;the output voltage reached 3.81 V when the annealing temperature was 150℃. The open-circuit voltage of the prepared self-powered accelerometer increased linearly with acceleration. In addition, the small NG-based accelerometer, which exhibited excellent fatigue resistance, can be used for acceleration measurements of small and lightweight devices. 展开更多
关键词 piezoelectric ZnO thin film RF MAGNETRON SPUTTERING ANNEALING temperature ACCELEROMETER
下载PDF
An iterative calibration method for nonlinear coefficients of marine triaxial accelerometers 被引量:2
7
作者 杨杰 吴文启 +1 位作者 武元新 练军想 《Journal of Central South University》 SCIE EI CAS 2013年第11期3103-3115,共13页
Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.Howe... Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.However,two significant accelerometer nonlinear errors need to be attacked to improve the modulation effect.Firstly,the asymmetry scale factor inaccuracy enlarges the errors of frequent zero-cross oscillating specific force measured by non-axial accelerometers.Secondly,the traditional linear model of accelerometers can hardly measure the continued or intermittent acceleration accurately.These two nonlinear errors degrade the high-precision specific force measurement and the calibration of nonlinear coefficients because triaxial accelerometers is urgent for the marine navigation.Based on the digital signal sampling property,the square coefficients and cross-coupling coefficients of accelerometers are considered.Meanwhile,the asymmetry scale factors are considered in the I-F conversion unit.Thus,a nonlinear model of specific force measurement is established compared to the linear model.Based on the three-axis turntable,the triaxial gyroscopes are utilized to measure the specific force observation for triaxial accelerometers.Considering the nonlinear combination,the standard calibration parameters and asymmetry factors are separately estimated by a two-step iterative identification procedure.Besides,an efficient specific force calculation model is approximately derived to reduce the real-time computation cost.Simulation results illustrate the sufficient estimation accuracy of nonlinear coefficients.The experiments demonstrate that the nonlinear model shows much higher accuracy than the linear model in both the gravimetry and sway navigation validations. 展开更多
关键词 ship navigation single-axis rotation inertial system laser gyroscopes quartz accelerometers nonlinear calibration
下载PDF
Understanding Tremor in Rapid Upper Limb Movements Using 3D Accelerometers Data 被引量:3
8
作者 Paula Pascoal-Faria Miguel Patrício +4 位作者 Adriana Leal Francisco Caramelo António Freire Cristina Januário Miguel Castelo-Branco 《Neuroscience & Medicine》 2014年第5期205-213,共9页
Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss ... Tremor is a manifestation of a variety of human neurodegenerative diseases, notably Parkinson’s disease (PD) and Essential Tremor (ET), both affecting millions worldwide. PD is primarily caused by a progressive loss of dopamine neurons in the nigrostriatal system that leads to widespread motor symptoms such as bradykinesia, rigidity, tremor and postural instability. ET typically involves a tremor of the arms, hands or fingers. No definitive test or biomarker is yet available for PD or ET, so the rate of misdiagnosis is relatively high. As tremor is a very common feature at the onset of both diseases, it is crucial to be able to characterize it. This is made possible using acce?lerometers to quantify the tremor amplitude and frequency. In this work we aim to find tasks involving upper limb movements that are suitable to modulate both types of tremor. Four tasks were tested, differing on whether the arms moved together or alternatingly and whether loads were added. Significant differences in tremor measures were found when patients were asked to perform simultaneous rapid arms movements with loads placed on their wrists. These results may allow the design of an efficient fMRI protocol for identifying the cortical circuits responsible for the modulation of tremor. 展开更多
关键词 DISEASE ESSENTIAL TREMOR TREMOR Quantification TREMOR MODULATION accelerometers
下载PDF
Suitable triggering algorithms for detecting strong ground motions using MEMS accelerometers 被引量:1
9
作者 Ravi Sankar Jakka Siddharth Garg 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期27-35,共9页
With the recent development of digital Micro Electro Mechanical System (MEMS) sensors, the cost of monitoring and detecting seismic events in real time can be greatly reduced. Ability of MEMS accelerograph to record... With the recent development of digital Micro Electro Mechanical System (MEMS) sensors, the cost of monitoring and detecting seismic events in real time can be greatly reduced. Ability of MEMS accelerograph to record a seismic event depends upon the efficiency of triggering algorithm, apart from the sensor's sensitivity. There are several classic triggering algorithms developed to detect seismic events, ranging from basic amplitude threshold to more sophisticated pattern recognition. Algorithms based on STA/LTA are reported to be computationally efficient for real time monitoring. In this paper, we analyzed several STA/LTA algorithms to check their efficiency and suitability using data obtained from the Quake Catcher Network (network of MEMS accelerometer stations). We found that most of the STA/LTA algorithms are suitable for use with MEMS accelerometer data to accurately detect seismic events. However, the efficiency of any particular algorithm is found to be dependent on the parameter set used (i.e., window width of STA, LTA and threshold level). 展开更多
关键词 strong ground motion triggering algorithms seismic event detection MEMS accelerometers STA/LTA based algorithms
下载PDF
Summary of Research Status and Application of MEMS Accelerometers 被引量:3
10
作者 Weimeng Niu Liqing Fang +4 位作者 Lei Xu Xu Li Ruikun Huo Deqing Guo Ziyuan Qi 《Journal of Computer and Communications》 2018年第12期215-221,共7页
The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS ac... The rapid development of MEMS technology has made MEMS accelerometers mature and the application range has been expanded. Many kinds of MEMS accelerometers are researched. According to the working principle of MEMS accelerometer, it can be divided into: piezoresistive, piezoelectric, capacitive, tunnel, resonant, electromagnetic, thermocouple, optical, inductive, etc. Due to its outstanding features in terms of size, quality, power consumption and reliability, MEMS sensors are used in military applications and where high environmental resistance is required. MEMS accelerometers are developing rapidly and have good application prospects. In order to make MEMS accelerometers more widely understood, the advantages of MEMS accelerometers are expounded. The research status of MEMS accelerometers is introduced, and MEMS are analyzed. The application of accelerometers in real-world environments, and the development trend of MEMS accelerometers in the future. More scholars will invest in MEMS accelerometer research, pursuing high performance, low power consumption, high precision, multi-function, and interaction. Strong MEMS accelerometers will be ubiquitous in the future. 展开更多
关键词 MEMS TECHNOLOGY MEMS ACCELEROMETER
下载PDF
Rigid Bridges Health Dynamic Monitoring Using 100 Hz GPS Single-Frequency and Accelerometers 被引量:1
11
作者 Joao Olympio de Araújo Neto Jorge Luiz Alves Trabanco +2 位作者 Ana Paula C.Larocca Andre Luiz Cunha Marcelo Carvalho dos Santos 《Positioning》 2019年第2期17-33,共17页
This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was p... This article presents the modal frequency recordings of a rigid bridge, monitored by the GPS receivers (Global Positioning System) with a data recording rate of 100 Hz and accelerometers. The GPS data processing was performed through the double-difference phase, using the adjusted interferometry technique (i.e. phase residue method—PRM&reg). In the method, the double-difference phase of the carrier L1 is realized by using two satellites only, one was positioned at the zenith of the structure and the other satellite was positioned near the horizon. The results of the parametric adjustment of the PRM observations were finalized through software Interferometry, mathematical algorithm were applied and compared with the accelerometer. The comparison served to validate the use of GPS as a fast and reliable instrument for the preliminary monitoring of the dynamic behavior of the bridge, road artworks which are common in several countries, especially in the Brazilian road network. The data time series from the GPS and accelerometers were processed using the Wavelet. The detection of frequencies means that the combination of 100 Hz GPS receivers and the PRM allows detecting vibrations up to 5 mm. It presented significant results which were never obtained by the Fourier Transform. 展开更多
关键词 GPS Rigid Bridge Modal Frequency Wavelet ACCELEROMETER Health Monitoring
下载PDF
Measurement of six degree-of-freedom ground motion by using eight accelerometers
12
作者 杨振宇 沈毅 刘志言 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第2期229-232,共4页
A new integrated measuring system with eight force-balance accelerometers is proposed to obtain a direct measurement of six degree-of freedom (DOF) ground motions, including three rotational and three actual transla... A new integrated measuring system with eight force-balance accelerometers is proposed to obtain a direct measurement of six degree-of freedom (DOF) ground motions, including three rotational and three actual translational acceleration components without gyroscopes. In the proposed measuring system, the relationship between the output from eight force-balance accelerometer and the six DOF motion of the measuring system under an earthquake are described by differential equations. These equations are derived from the positions and directions of the eight force-balance accelerometers in the measuring system. The third-order Runge-Kutta algorithm is used to guarantee the accuracy of the numerical calculation. All the algorithms used to compute the six DOF components of the ground motion are implemented in a real-time in Digital Signal Processor (DSP). The distortion of the measured results caused by position and direction errors of the accelerometers in the measuring system are reduced by multiplying a compensation coefficient C to the output and subtracting static zero drift from the measured results, respectively. 展开更多
关键词 six degree-of-freedom ground motion force-balance accelerometer translational acceleration rotational acceleration
下载PDF
A Survey of Error Analysis and Calibration Methods for MEMS Triaxial Accelerometers
13
作者 Bo Xiao Yinghang Jiang +2 位作者 Qi Liu Xiaodong Liu Mingxu Sun 《Computers, Materials & Continua》 SCIE EI 2020年第7期389-399,共11页
MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safe... MEMS accelerometers are widely used in various fields due to their small size and low cost,and have good application prospects.However,the low accuracy limits its range of applications.To ensure data accuracy and safety we need to calibrate MEMS accelerometers.Many authors have improved accelerometer accuracy by calculating calibration parameters,and a large number of published calibration methods have been confusing.In this context,this paper introduces these techniques and methods,analyzes and summarizes the main error models and calibration procedures,and provides useful suggestions.Finally,the content of the accelerometer calibration method needs to be overcome. 展开更多
关键词 MEMS ACCELEROMETER CALIBRATION error analysis accelerometer calibration
下载PDF
Multiple dependent reliability estimation of large range MEMS accelerometers in high temperature environment
14
作者 QIN Li HE Cheng +2 位作者 YU Li-xia WANG Wei QIN Li-jun 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第1期9-15,共7页
In the past,only one performance parameter was considered in the reliability estimation of micro-electro-mechanical system (MEMS) accelerometers,resulting in a one-sided reliability evaluation. Aiming at the failure c... In the past,only one performance parameter was considered in the reliability estimation of micro-electro-mechanical system (MEMS) accelerometers,resulting in a one-sided reliability evaluation. Aiming at the failure condition of large range MEMS accelerometers in high temperature environment,the corresponding accelerated degradation test is designed. According to the degradation condition of zero bias and scale factor,multiple dependent reliability estimation of large range MEMS accelerometers is carried out. The results show that the multiple dependent reliability estimation of the large range MEMS accelerometers can improve the accuracy of the estimation and get more accurate results. 展开更多
关键词 large range MEMS accelerometers zero bias scale factor multiple dependent reliability estimation accelerated degradation test
下载PDF
内蒙古地区强震动台站背景噪声与数据质量分析 被引量:1
15
作者 安全 韩晓明 +3 位作者 包文超 翟浩 赵铁锁 赵星 《地震学报》 CSCD 北大核心 2024年第3期490-501,共12页
计算了内蒙古地区193个强震动台站2022年连续观测数据的加速度功率谱密度,通过绘制不同时空、不同加速度计、不同频段的功率谱密度和功率谱概率密度函数图及背景噪声速度均方根值分布图,评估了该区强震动台站的背景噪声变化特征,对出现... 计算了内蒙古地区193个强震动台站2022年连续观测数据的加速度功率谱密度,通过绘制不同时空、不同加速度计、不同频段的功率谱密度和功率谱概率密度函数图及背景噪声速度均方根值分布图,评估了该区强震动台站的背景噪声变化特征,对出现的功率谱密度异常进行了具体分析,并针对强震动台站数据异常检测及处理提出了相应的建议。研究结果显示:不同加速度计、不同时空强震动台站的背景噪声功率谱密度昼夜差异主要体现在1 Hz以上频段,且不同区域的昼夜差异变化较大;QA-2g型、JS-A2型和TDA-33M型三种加速度计在2 s频点的背景噪声功率谱密度随区域和三分向变化较小;从强震动台站2 s频点背景噪声的监控能得到可靠的观测数据异常,数据异常主要由加速度计零点漂移大、加速度计故障、脉冲干扰、系统参数有误造成,建议优化站点观测环境,进一步规范仪器安装、调试及JOPENS系统的参数配置和审核。 展开更多
关键词 强震动台站 功率谱密度(PSD)值 速度均方根 数据质量 加速度计
下载PDF
基于MEMS加速度计与磁力计的位移计设计 被引量:1
16
作者 王晓初 刘湘邦 +1 位作者 张胜辉 刘强 《机电工程技术》 2024年第1期81-85,共5页
基坑水平位移监测是基坑安全的重要检测项目之一。针对现有的阵列式位移计在基坑水平位移监测中容易产生扭转误差的问题,设计了一种基于MEMS加速度计与磁力计的位移计,能够同时满足基坑水平位移与沉降位移监测的需求。介绍了位移计自动... 基坑水平位移监测是基坑安全的重要检测项目之一。针对现有的阵列式位移计在基坑水平位移监测中容易产生扭转误差的问题,设计了一种基于MEMS加速度计与磁力计的位移计,能够同时满足基坑水平位移与沉降位移监测的需求。介绍了位移计自动化实时监测系统组成。对位移计的结构以及监测节的硬件电路进行了设计,并制作完成了位移计样机。阐述了位移计通过对加速度计与磁力计的数据进行融合,计算位移坐标的测量原理和扭转误差校正的方法。最后通过模拟监测节间发生扭转时位移计水平位移监测的实验,以及位移计沉降位移监测试验。实验结果表明,该位移计能够精确测量水平与沉降位移,并能够有效校正位移计竖直安装时监测节扭转带来的扭转误差。 展开更多
关键词 MEMS加速度计 磁力计 姿态解析 扭转校正
下载PDF
一种摆式谐振加速度计的微杠杆结构设计与分析
17
作者 周严 张宇轩 +3 位作者 姚志超 吴天豪 苏岩 张晶 《中国惯性技术学报》 EI CSCD 北大核心 2024年第3期290-299,共10页
为提升摆式谐振式加速度计性能,设计了一种将质量块与微杠杆结构一体化的摆式微杠杆结构,实现惯性力的敏感与放大,提升结构的鲁棒性。首先建立了微杠杆结构力学模型,并进行了关键参数计算。其次,根据微杠杆结构放大倍数影响机理,分析了... 为提升摆式谐振式加速度计性能,设计了一种将质量块与微杠杆结构一体化的摆式微杠杆结构,实现惯性力的敏感与放大,提升结构的鲁棒性。首先建立了微杠杆结构力学模型,并进行了关键参数计算。其次,根据微杠杆结构放大倍数影响机理,分析了质量块、支撑梁及微杠杆结构尺寸参数对放大倍数的影响;理论分析与有限元仿真结果均表明,支点梁与输出梁的宽度应作为该类微杠杆的关键优化参数。最后,根据上述结论对现有结构尺寸进行优化,优化后的微杠杆放大倍数为15.68,系统放大倍数为12.88,标度因数为70.52 Hz/g,较优化前分别提升了36.94%、36.87%和36.88%,验证了优化方法的有效性。 展开更多
关键词 谐振式加速度计 摆式结构 微杠杆 放大倍数
下载PDF
某型摆式加速度计自动盖总成装配系统
18
作者 任同群 吴晗 +2 位作者 蒋锐锋 介迪 王晓东 《光学精密工程》 EI CAS CSCD 北大核心 2024年第18期2772-2782,共11页
摆式加速度计广泛应用于航空航天、船舶等领域的惯性导航系统中,其装配作业目前主要依赖于人工操作,产品一致性难以保证。鉴于此,本文针对某型摆式加速度计研制了一套自动装配系统。基于宏微结合的设计策略,搭建基于高精度运动滑台的微... 摆式加速度计广泛应用于航空航天、船舶等领域的惯性导航系统中,其装配作业目前主要依赖于人工操作,产品一致性难以保证。鉴于此,本文针对某型摆式加速度计研制了一套自动装配系统。基于宏微结合的设计策略,搭建基于高精度运动滑台的微动平台,以及基于单轴机器人的宏动平台。确立了以微动平台为精调核心,以宏动平台辅助压装并实现不同功能模块工作位置调整的装配机制,同时设计功能模块上中下三层的立体分层式结构,在保证精度的同时避免作业空间的拥挤。引入六轴协作机器人并集成视觉系统,实现作业空间的全覆盖识别和自动化上下料功能。针对磁钢零件磁性力对装配精度的影响,采用零件内部辅助限位的方式,实现零件装配精度的保持。基于刚体变换,对系统进行误差分析并推导了误差补偿模型。实验结果验证,该装配系统的角度装配精度优于±0.03°,压装力精度优于±0.5 N,扭力精度优于±0.003 N·m,满足装配要求,为该型摆式加速度计的批量化生产提供了有力保障。 展开更多
关键词 摆式加速度计 装配精度 微动平台 作业空间 零件装配 装配作业 装配系统 视觉系统
下载PDF
轻小型高可靠回收控制器设计与实现
19
作者 刘靖雷 闫云龙 +3 位作者 裴晓燕 孙希昀 刘海烨 乔茂永 《航天返回与遥感》 CSCD 北大核心 2024年第4期29-38,共10页
针对某商用返回式卫星回收系统轻小型、高可靠的约束要求,设计了一种新型回收控制器产品,该装置基于微电子机械系统(Micro Electro Mechanical Systems,MEMS)过载传感器进行弹道过载测量,采用双核四进程“与或”逻辑实现冗余控制,基于... 针对某商用返回式卫星回收系统轻小型、高可靠的约束要求,设计了一种新型回收控制器产品,该装置基于微电子机械系统(Micro Electro Mechanical Systems,MEMS)过载传感器进行弹道过载测量,采用双核四进程“与或”逻辑实现冗余控制,基于容性释能半导体桥点火器起爆技术实现火工品管理。策划了针对返回过程的弹道过载触发验证试验,针对容性释能电容阵列放电特性,开展了容性释能系统不同初始电压、不同电容阵列容值以及不同回路阻值下的点火效能仿真分析。结果表明该回收控制器在轻小型约束下返回弹道过载感知精度达到±0.28 g,可实现开伞逻辑高可靠控制。半导体桥点火器容性释能电路优化参数为初始电压大于24 V、回路阻值小于0.3Ω、初始电容大于22μF,可实现点火器高可靠点火控制。该设计在不显著增加硬件基础上,大大降低产品质量,可为航空航天用同类电子系统设计提供参考。 展开更多
关键词 回收控制器 过载传感器 开伞控制 容性释能
下载PDF
陀螺加速度计精细化建模仿真方法研究
20
作者 荣吉利 杨梓航 +4 位作者 周晓俊 李亮 李剑峰 刘睿 程修妍 《北京理工大学学报》 EI CAS CSCD 北大核心 2024年第12期1233-1240,共8页
研究陀螺加速度计精细化建模仿真分析方法.对整表结构进行了有限元网格划分,采用螺栓单元法进行简化处理,通过虚质量法对高密度浮油进行建模,计算外环轴轴承相关参数,并通过刚度轴承建模法进行仿真,建立了精细化陀螺加速度计有限元仿真... 研究陀螺加速度计精细化建模仿真分析方法.对整表结构进行了有限元网格划分,采用螺栓单元法进行简化处理,通过虚质量法对高密度浮油进行建模,计算外环轴轴承相关参数,并通过刚度轴承建模法进行仿真,建立了精细化陀螺加速度计有限元仿真模型.通过模态测试与模态仿真相对比,验证了有限元仿真模型的有效性.基于有限元模型,分析研究了在过载条件下外环轴轴承预紧力对仪表浮子质心偏移的影响,并据此进一步分析了预紧力对整表精度的影响.结果表明:适当提升外环轴预紧力有助于提高整表精度;过高的预紧力会导致精度下降,预紧力对于精度的影响大小也与视加速度相关. 展开更多
关键词 陀螺加速度计 有限元仿真 模态测试 误差预示
下载PDF
上一页 1 2 178 下一页 到第
使用帮助 返回顶部