The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrin...The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrinkage polyester filaments.And the fabric was treated by a self-designed partial heat device,which can make the sensor be fixed in the fabric.The effects of yarn type,yarn linear density,fabric warp density,fabric structure,fabric layer numbers where the sensor is located,and the ambient temperature on the temperature measured value were investigated.The results demonstrated that when the higher thermal conductivity of yarns and lower density yarns were applied in the fabric as rawmaterials,they were favored to improve the measurement precision.Meanwhile,there were many factors that could make the measured values closer to the real value of the body,such as the plain fabric,the increased warp density of the fabric,the multiple-layer fabric where the sensor was located,the raised ambient testing temperature and the prolonged test time in the certain range.展开更多
The main reasons for the occurrence of temperature error and perspective directions of decreasing of its value are presented by improving the device design based on the phenomenon of surface plasmon resonance (SPR) an...The main reasons for the occurrence of temperature error and perspective directions of decreasing of its value are presented by improving the device design based on the phenomenon of surface plasmon resonance (SPR) and numerical methods of processing the results of measurements by this device. The most essential influence on changes in results of measurements can be rendered by temperature changes in the analyte refractive index. It is shown that the application of the integrated temperature stabilization of the device with the test substance, and numerical processing of the measurement results for compensation of temperature changes of the test substance and the use of film heaters it is possible to reduce the measurement error of the refractive index of the analyte at least 30 times from 2.4 × 10-4 to 7.6 × 10-6.展开更多
In order to determine the size measurement accuracy of the high temperature forging's multicolor CCD image by using computerprograms, this paper obtained the high temperature forging's CCD image by multicolor CCD ca...In order to determine the size measurement accuracy of the high temperature forging's multicolor CCD image by using computerprograms, this paper obtained the high temperature forging's CCD image by multicolor CCD camera and its fact size by thevernier caliper on the forging field, and then measured the size of the high temperature forging from its CCD image, compared thesize from the CCD image and the size from the vernier caliper, the result shows that the measurement accuracy satisfied theindustrial production.展开更多
Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram....Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface.展开更多
This paper analysis the developing of expendable conductivity temperature depth measuring system(XCTD)and introduce its principle of measuring about temperature,salinity and depth of ocean.Some key techniques are put ...This paper analysis the developing of expendable conductivity temperature depth measuring system(XCTD)and introduce its principle of measuring about temperature,salinity and depth of ocean.Some key techniques are put forward.According to the real needs of XCTD,conductivity sensor with high sensitivity is designed by principle of electromagnetic induce,the ocean conductivity from induced electromotive force has been calculated.Adding temperature correction circuit would help to reduce error of conductivity measurement because of sharply changing temperature.Advanced temperature measuring circuit of high precision and the constant current source is used to weaken effect of self-heating of resistance and fluctuation of the source.On respect of remote data transmission,LVDS is a good choice for the purpose of guarantee the quality of data transmitted and the transmission distance is reaching to thousand meters in the seawater.Modular programming method is also brought into this research aimed at improve the stability,reliability and maintainability of the whole measuring system.In February,2015,the trials in South China Sea demonstrate that the developed XCTD realize effective measurement at a speed of 6 knots and detection depth at 800 m.The consistency coefficient of the acquired data is greater than 0.99 and the success rate of probe launching is above 90%.展开更多
Single frequency GNSS receivers are the most widely used tools for tracking, navigation and geo-referencing around the world. It is estimated that over 75% of all GNSS receivers used globally are single frequency rece...Single frequency GNSS receivers are the most widely used tools for tracking, navigation and geo-referencing around the world. It is estimated that over 75% of all GNSS receivers used globally are single frequency receivers and users experience positioning error due to the ionosphere. To enable GNSS Single Frequency Precise Point Positioning (SFPPP), accurate a-prior information about the ionosphere is needed. The variation of the ionosphere is larger around the magnetic equator and therefore depends on latitude. It will be expected that SFPPP works better on latitude further from the magnetic equator. This present study aims to investigate the accuracy of some ionospheric error mitigation approaches used in single frequency precise point positioning (SFPPP) at several GNSS station in the new Nigerian GNSS Network (NIGNet) and two IGS sites in the low equatorial African region. This study covers two epochs of observation. The first consists of observation from three consecutive days (GPS week 1638;days 0, 1 and 2) that belongs to a period of low solar activities. The second epoch consists of observation from three consecutive days (GPS week 1647;days 2, 3 and 4) that belongs to a high solar activity and intense geomagnetic conditions. The estimated position for the GNSS stations from dual frequency measurement and their known ITRF solutions were used as a benchmark to assess the accuracy of SFPPP under four conditions i.e., SFPPP without ionospheric correction, SFPPP using final GIM models from the Centre for Orbit Determination in Europe( CODE), SFPPP with Klobuchar model, and SFPPP with a computed (local) model at each station. All computation was done using Leica Geo-office software. The result of the study clearly demonstrates the significance of removing or correcting for the effect of the ionosphere, which can result in up to 7 m displacement. It was recommended that GIMs from different organization should be investigated and also efforts should be towards improvement in algorithms and clock error modeling.展开更多
基于提升低温共烧陶瓷(low temperature co-fired ceramic,LTCC)厚度的检测精度、测量效率和可溯源性的需求,设计一套LTCC激光测厚系统。针对测量精度难以满足需求的问题,对存在误差进行分析,采用厚度测量用调整夹具消除同轴度误差和线...基于提升低温共烧陶瓷(low temperature co-fired ceramic,LTCC)厚度的检测精度、测量效率和可溯源性的需求,设计一套LTCC激光测厚系统。针对测量精度难以满足需求的问题,对存在误差进行分析,采用厚度测量用调整夹具消除同轴度误差和线性度误差,优化设计结构降低倾角误差,循环传感器标定消除重复度误差,通过数据优化和滤波处理降低机械振动误差,提高了系统测量精度。与实际产品厚度数据对比,最终精度误差≤5μm,符合产品的应用要求,具有广阔的应用市场。展开更多
基金Hubei Province Natural Science Fund Project,China(No.2013CFA090)
文摘The embedded temperature sensing fabric was designed and woven according to the heat transmission model of the fabric.The temperature sensors were embedded into the multi-layered fabric that weft yarns were high-shrinkage polyester filaments.And the fabric was treated by a self-designed partial heat device,which can make the sensor be fixed in the fabric.The effects of yarn type,yarn linear density,fabric warp density,fabric structure,fabric layer numbers where the sensor is located,and the ambient temperature on the temperature measured value were investigated.The results demonstrated that when the higher thermal conductivity of yarns and lower density yarns were applied in the fabric as rawmaterials,they were favored to improve the measurement precision.Meanwhile,there were many factors that could make the measured values closer to the real value of the body,such as the plain fabric,the increased warp density of the fabric,the multiple-layer fabric where the sensor was located,the raised ambient testing temperature and the prolonged test time in the certain range.
文摘The main reasons for the occurrence of temperature error and perspective directions of decreasing of its value are presented by improving the device design based on the phenomenon of surface plasmon resonance (SPR) and numerical methods of processing the results of measurements by this device. The most essential influence on changes in results of measurements can be rendered by temperature changes in the analyte refractive index. It is shown that the application of the integrated temperature stabilization of the device with the test substance, and numerical processing of the measurement results for compensation of temperature changes of the test substance and the use of film heaters it is possible to reduce the measurement error of the refractive index of the analyte at least 30 times from 2.4 × 10-4 to 7.6 × 10-6.
文摘In order to determine the size measurement accuracy of the high temperature forging's multicolor CCD image by using computerprograms, this paper obtained the high temperature forging's CCD image by multicolor CCD camera and its fact size by thevernier caliper on the forging field, and then measured the size of the high temperature forging from its CCD image, compared thesize from the CCD image and the size from the vernier caliper, the result shows that the measurement accuracy satisfied theindustrial production.
文摘Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface.
文摘This paper analysis the developing of expendable conductivity temperature depth measuring system(XCTD)and introduce its principle of measuring about temperature,salinity and depth of ocean.Some key techniques are put forward.According to the real needs of XCTD,conductivity sensor with high sensitivity is designed by principle of electromagnetic induce,the ocean conductivity from induced electromotive force has been calculated.Adding temperature correction circuit would help to reduce error of conductivity measurement because of sharply changing temperature.Advanced temperature measuring circuit of high precision and the constant current source is used to weaken effect of self-heating of resistance and fluctuation of the source.On respect of remote data transmission,LVDS is a good choice for the purpose of guarantee the quality of data transmitted and the transmission distance is reaching to thousand meters in the seawater.Modular programming method is also brought into this research aimed at improve the stability,reliability and maintainability of the whole measuring system.In February,2015,the trials in South China Sea demonstrate that the developed XCTD realize effective measurement at a speed of 6 knots and detection depth at 800 m.The consistency coefficient of the acquired data is greater than 0.99 and the success rate of probe launching is above 90%.
文摘Single frequency GNSS receivers are the most widely used tools for tracking, navigation and geo-referencing around the world. It is estimated that over 75% of all GNSS receivers used globally are single frequency receivers and users experience positioning error due to the ionosphere. To enable GNSS Single Frequency Precise Point Positioning (SFPPP), accurate a-prior information about the ionosphere is needed. The variation of the ionosphere is larger around the magnetic equator and therefore depends on latitude. It will be expected that SFPPP works better on latitude further from the magnetic equator. This present study aims to investigate the accuracy of some ionospheric error mitigation approaches used in single frequency precise point positioning (SFPPP) at several GNSS station in the new Nigerian GNSS Network (NIGNet) and two IGS sites in the low equatorial African region. This study covers two epochs of observation. The first consists of observation from three consecutive days (GPS week 1638;days 0, 1 and 2) that belongs to a period of low solar activities. The second epoch consists of observation from three consecutive days (GPS week 1647;days 2, 3 and 4) that belongs to a high solar activity and intense geomagnetic conditions. The estimated position for the GNSS stations from dual frequency measurement and their known ITRF solutions were used as a benchmark to assess the accuracy of SFPPP under four conditions i.e., SFPPP without ionospheric correction, SFPPP using final GIM models from the Centre for Orbit Determination in Europe( CODE), SFPPP with Klobuchar model, and SFPPP with a computed (local) model at each station. All computation was done using Leica Geo-office software. The result of the study clearly demonstrates the significance of removing or correcting for the effect of the ionosphere, which can result in up to 7 m displacement. It was recommended that GIMs from different organization should be investigated and also efforts should be towards improvement in algorithms and clock error modeling.
文摘基于提升低温共烧陶瓷(low temperature co-fired ceramic,LTCC)厚度的检测精度、测量效率和可溯源性的需求,设计一套LTCC激光测厚系统。针对测量精度难以满足需求的问题,对存在误差进行分析,采用厚度测量用调整夹具消除同轴度误差和线性度误差,优化设计结构降低倾角误差,循环传感器标定消除重复度误差,通过数据优化和滤波处理降低机械振动误差,提高了系统测量精度。与实际产品厚度数据对比,最终精度误差≤5μm,符合产品的应用要求,具有广阔的应用市场。