Acetabular cups,which are among themost important implants in total hip arthroplasty,are usually made from titanium alloys with high porosity and adequate mechanical properties.The current three-dimensional(3D)printin...Acetabular cups,which are among themost important implants in total hip arthroplasty,are usually made from titanium alloys with high porosity and adequate mechanical properties.The current three-dimensional(3D)printing approaches to fabricate customized acetabular cups have some inherent disadvantages such as high cost and energy consumption,residual thermal stress,and relatively low efficiency.Thus,in this work,a direct ink writing method was developed to print a cup structure at room temperature,followed by multi-step heat treatment to form microscale porous structure within the acetabular cup.Our method is facilitated by the development of a self-supporting titanium-6 aluminum-4 vanadium(Ti64)ink that is composed of Ti64 particles,bentonite yield-stress additive,ultraviolet curable polymer,and photo-initiator.The effects of Ti64 and bentonite concentrations on the rheological properties and printability of inks were systematically investigated.Moreover,the printing conditions,geometrical limitations,and maximum curing depth were explored.Finally,some complex 3D structures,including lattices with different gap distances,honeycomb with a well-defined shape,and an acetabular cup with uniformly distributed micropores,were successfully printed/fabricated to validate the effectiveness of the proposed method.展开更多
Clinical two-dimensional linear wear rate data for acetabular cup liners fabricated using approved brands of highly cross-linked ultra-high-molecular-weight polyethylene, as reported in 39 articles in the literature, ...Clinical two-dimensional linear wear rate data for acetabular cup liners fabricated using approved brands of highly cross-linked ultra-high-molecular-weight polyethylene, as reported in 39 articles in the literature, were analyzed using a statistical technique called response surface methodology. The output was a series comprising16 acceptable combinations of femoral head diameter (HD), femoral head material (HM), and HXLPE brand (PB), each of which would yield the optimum wear rate (herein taken to be a wear rate of practically zero). An example of such a combination is 28- mm-diameter Oxinium? femoral head articulated against an acetabular cup liner fabricated from ReflectionTM HXLPE. The findings in this work may guide an orthopaedic surgeon’s selection of the combination of HD, HM, and PB to use in a primary total hip joint replacement.展开更多
目的设计一种三维角度仪,将其应用在全髋关节置换术(total hip arthroplasty,THA)中,以测量髋臼臼杯把持杆的倾斜角度,评估其是否能提高髋臼臼杯植入角度(外展角和前倾角)的精准度。方法将2020年9月至2022年10月武汉中西医结合骨科医院...目的设计一种三维角度仪,将其应用在全髋关节置换术(total hip arthroplasty,THA)中,以测量髋臼臼杯把持杆的倾斜角度,评估其是否能提高髋臼臼杯植入角度(外展角和前倾角)的精准度。方法将2020年9月至2022年10月武汉中西医结合骨科医院收治的30例患者分成测量仪组(采用三维角度仪辅助进行THA组,15例)和传统组(传统THA组,15例),两组术前规划髋臼臼杯置入的外展角为38º、前倾角为20º,比较两组术后X线片上所测得髋臼臼杯置放的角度(外展角和前倾角)与其术前所规划臼杯置入角度之间的误差。结果测量仪组术后髋臼臼杯置放的角度(外展角和前倾角)与术前所规划角度的误差明显小于传统组。结论相对于传统THA术中医生用肉眼瞄髋臼臼杯置入方向而言,采用此三维角度仪辅助进行THA,能在术中对髋臼臼杯置入的方向进行刻度化测量,能提高髋臼臼杯置入角度的精准度,其操作简单,值得推广。展开更多
目的评估利用“双杯”技术(去除钛环的钽金属翻修臼杯作为增强块)治疗PaproskyⅢ型髋臼缺损的早期临床效果。方法回顾性地分析评估了2017—2023年在中国科学技术大学附属第一医院(安徽省立医院)接受“双杯”技术进行治疗的54例全髋关节...目的评估利用“双杯”技术(去除钛环的钽金属翻修臼杯作为增强块)治疗PaproskyⅢ型髋臼缺损的早期临床效果。方法回顾性地分析评估了2017—2023年在中国科学技术大学附属第一医院(安徽省立医院)接受“双杯”技术进行治疗的54例全髋关节翻修术病例。其中男女性患者数量一致,均为27例,年龄30~92岁,平均年龄(65.8±12.3)岁。通过记录患者术前和末次随访时Harris髋关节评分、Oxford髋关节评分和36项健康调查简表(36-item short form survey,SF-36)功能评分来评估临床功能结果;对术前、术后髋关节旋转中心位置和双下肢长度差在影像学上进行评估;评估有无假体松动等术后并发症的发生。结果54例患者均获随访,随访时间为8~80个月,平均(35.3±20.9)个月。术前Harris髋关节评分、Oxford髋关节评分和SF-36功能评分分别为(35.6±10.5)分、(24.4±7.1)分和(805.7±47.5)分,末次随访时分别为(90.6±11.5)分、(44.0±4.2)分和(859.4±47.4)分,患者临床功能结果得到显著改善(P<0.001)。此外,末次随访的影像学结果显示,无论是髋关节旋转中心位置还是双下肢长度差与术前相比都有明显改善(P<0.001),实现了良好的生物力学重建。术后无假体周围感染,6例患者发生假体脱位,但只有1例患者在随访中因假体反复脱位进行了二次手术。结论“双杯”技术是进行PaproskyⅢA和ⅢB型严重髋臼缺损重建的可靠选择,其并发症少、安全性高、功能恢复好,值得在临床上大力推广。展开更多
背景:髋关节置换是治疗股骨头坏死、骨性关节炎、髋关节发育不良以及老年股骨颈骨折等髋关节疾病最有效的方法,因此有必要对髋关节置换的生物力学行为展开研究。目的:采用有限元仿真的方法模拟髋关节置换后骨小梁结构髋臼杯和实体结构...背景:髋关节置换是治疗股骨头坏死、骨性关节炎、髋关节发育不良以及老年股骨颈骨折等髋关节疾病最有效的方法,因此有必要对髋关节置换的生物力学行为展开研究。目的:采用有限元仿真的方法模拟髋关节置换后骨小梁结构髋臼杯和实体结构髋臼杯模型的接触应力和米氏应力大小和分布情况,分析其对假体及髋关节的影响。方法:通过3-Matic Research 11.0软件设计了2种不同结构的髋关节假体组件模型:骨小梁结构髋臼杯和实体结构髋臼杯模型。并将设计好的模型经Hypermesh 14.0软件划分网格并赋予材料属性,最后导入有限元分析软件Abaqus 6.13软件中仿真分析,比较相同状态下2种髋臼杯的应力值和应力分布情况。结果与结论:骨小梁结构髋臼杯的应力呈散点状分布,分布范围广。实体结构髋臼杯容易出现应力集中现象,应力分布集中在受力点附近。骨小梁结构髋臼杯相对于实体结构髋臼杯而言,应力分布范围更大,应力分布更均匀,从而可以减轻髋关节假体之间的磨损,降低髋关节假体发生无菌性松动的风险。展开更多
基金supported by the Micro Grant (PG20473) at the University of Nevada, Reno, USA
文摘Acetabular cups,which are among themost important implants in total hip arthroplasty,are usually made from titanium alloys with high porosity and adequate mechanical properties.The current three-dimensional(3D)printing approaches to fabricate customized acetabular cups have some inherent disadvantages such as high cost and energy consumption,residual thermal stress,and relatively low efficiency.Thus,in this work,a direct ink writing method was developed to print a cup structure at room temperature,followed by multi-step heat treatment to form microscale porous structure within the acetabular cup.Our method is facilitated by the development of a self-supporting titanium-6 aluminum-4 vanadium(Ti64)ink that is composed of Ti64 particles,bentonite yield-stress additive,ultraviolet curable polymer,and photo-initiator.The effects of Ti64 and bentonite concentrations on the rheological properties and printability of inks were systematically investigated.Moreover,the printing conditions,geometrical limitations,and maximum curing depth were explored.Finally,some complex 3D structures,including lattices with different gap distances,honeycomb with a well-defined shape,and an acetabular cup with uniformly distributed micropores,were successfully printed/fabricated to validate the effectiveness of the proposed method.
文摘Clinical two-dimensional linear wear rate data for acetabular cup liners fabricated using approved brands of highly cross-linked ultra-high-molecular-weight polyethylene, as reported in 39 articles in the literature, were analyzed using a statistical technique called response surface methodology. The output was a series comprising16 acceptable combinations of femoral head diameter (HD), femoral head material (HM), and HXLPE brand (PB), each of which would yield the optimum wear rate (herein taken to be a wear rate of practically zero). An example of such a combination is 28- mm-diameter Oxinium? femoral head articulated against an acetabular cup liner fabricated from ReflectionTM HXLPE. The findings in this work may guide an orthopaedic surgeon’s selection of the combination of HD, HM, and PB to use in a primary total hip joint replacement.
文摘目的设计一种三维角度仪,将其应用在全髋关节置换术(total hip arthroplasty,THA)中,以测量髋臼臼杯把持杆的倾斜角度,评估其是否能提高髋臼臼杯植入角度(外展角和前倾角)的精准度。方法将2020年9月至2022年10月武汉中西医结合骨科医院收治的30例患者分成测量仪组(采用三维角度仪辅助进行THA组,15例)和传统组(传统THA组,15例),两组术前规划髋臼臼杯置入的外展角为38º、前倾角为20º,比较两组术后X线片上所测得髋臼臼杯置放的角度(外展角和前倾角)与其术前所规划臼杯置入角度之间的误差。结果测量仪组术后髋臼臼杯置放的角度(外展角和前倾角)与术前所规划角度的误差明显小于传统组。结论相对于传统THA术中医生用肉眼瞄髋臼臼杯置入方向而言,采用此三维角度仪辅助进行THA,能在术中对髋臼臼杯置入的方向进行刻度化测量,能提高髋臼臼杯置入角度的精准度,其操作简单,值得推广。
文摘目的评估利用“双杯”技术(去除钛环的钽金属翻修臼杯作为增强块)治疗PaproskyⅢ型髋臼缺损的早期临床效果。方法回顾性地分析评估了2017—2023年在中国科学技术大学附属第一医院(安徽省立医院)接受“双杯”技术进行治疗的54例全髋关节翻修术病例。其中男女性患者数量一致,均为27例,年龄30~92岁,平均年龄(65.8±12.3)岁。通过记录患者术前和末次随访时Harris髋关节评分、Oxford髋关节评分和36项健康调查简表(36-item short form survey,SF-36)功能评分来评估临床功能结果;对术前、术后髋关节旋转中心位置和双下肢长度差在影像学上进行评估;评估有无假体松动等术后并发症的发生。结果54例患者均获随访,随访时间为8~80个月,平均(35.3±20.9)个月。术前Harris髋关节评分、Oxford髋关节评分和SF-36功能评分分别为(35.6±10.5)分、(24.4±7.1)分和(805.7±47.5)分,末次随访时分别为(90.6±11.5)分、(44.0±4.2)分和(859.4±47.4)分,患者临床功能结果得到显著改善(P<0.001)。此外,末次随访的影像学结果显示,无论是髋关节旋转中心位置还是双下肢长度差与术前相比都有明显改善(P<0.001),实现了良好的生物力学重建。术后无假体周围感染,6例患者发生假体脱位,但只有1例患者在随访中因假体反复脱位进行了二次手术。结论“双杯”技术是进行PaproskyⅢA和ⅢB型严重髋臼缺损重建的可靠选择,其并发症少、安全性高、功能恢复好,值得在临床上大力推广。
文摘背景:髋关节置换是治疗股骨头坏死、骨性关节炎、髋关节发育不良以及老年股骨颈骨折等髋关节疾病最有效的方法,因此有必要对髋关节置换的生物力学行为展开研究。目的:采用有限元仿真的方法模拟髋关节置换后骨小梁结构髋臼杯和实体结构髋臼杯模型的接触应力和米氏应力大小和分布情况,分析其对假体及髋关节的影响。方法:通过3-Matic Research 11.0软件设计了2种不同结构的髋关节假体组件模型:骨小梁结构髋臼杯和实体结构髋臼杯模型。并将设计好的模型经Hypermesh 14.0软件划分网格并赋予材料属性,最后导入有限元分析软件Abaqus 6.13软件中仿真分析,比较相同状态下2种髋臼杯的应力值和应力分布情况。结果与结论:骨小梁结构髋臼杯的应力呈散点状分布,分布范围广。实体结构髋臼杯容易出现应力集中现象,应力分布集中在受力点附近。骨小梁结构髋臼杯相对于实体结构髋臼杯而言,应力分布范围更大,应力分布更均匀,从而可以减轻髋关节假体之间的磨损,降低髋关节假体发生无菌性松动的风险。