Direct Oxidation of Ethene to Acetic Acid
1
作者 Ke Gong FANG Xin Ping WANG +1 位作者 Jian Lu ZHANG Tian Xi CAI 《Chinese Chemical Letters》 SCIE CAS CSCD 2001年第2期125-126,共2页
Direct oxidation of ethene to acetic acid over Pd-SiW12/SiO2 catalysts prepared by several methods was studied. A better method for reducing palladium composition of the catalysts was found. Acetic acid was obtained w... Direct oxidation of ethene to acetic acid over Pd-SiW12/SiO2 catalysts prepared by several methods was studied. A better method for reducing palladium composition of the catalysts was found. Acetic acid was obtained with selectivity of 82.7% and once-through space time yield (STY) of 257.4 g/h .L. 展开更多
关键词 Pd-SiW12/SiO2 catalyst acetic acid production ethene oxidation.
下载PDF
A comparative study of liquid and solid inner contact roxatidine acetate ion-selective electrode membranes
2
作者 Mohamed K.Abd El-Rahman Hala E.Zaazaa +3 位作者 Samah S.Abbas Badr El-Zeany Zeinab A.EL-Sherif Dalia A.EL-Haddad 《Chinese Chemical Letters》 SCIE CAS CSCD 2015年第6期714-720,共7页
A comparative study was conducted using two designs of a roxatidine acetate (ROX)-selective electrode; a conventional liquid inner contact called electrode A and a graphite-coated solid contact called electrode 13. ... A comparative study was conducted using two designs of a roxatidine acetate (ROX)-selective electrode; a conventional liquid inner contact called electrode A and a graphite-coated solid contact called electrode 13. The fabrication of electrodes was based on roxatidine-tetraphenylborate (ROX-TPB) as an ion-association complex in a PVC matrix using different plasticizers. Electrode A has a linear dynamic range of 2.2 ×10^-5 mol/L to 1.0 ×10^-2 mol/L, with a Nernstian slope of 54.7 mV/decade and a detection limit of 1.4 ×10^-6 mol/L. Electrode B shows linearity over the concentration range of 1.0×10^-6 mol/L to 1.0×10^-2 tool/L, with a Nernstian slope of 51.2 mV/decade and a limit of detection of 1.1×10^7 mol/L which is remarkably improved as a result of diminishing ion fluxes in this solid contact, ion-selective electrode. The proposed sensors display useful analytical characteristics for the determination of ROX in bulk powder and its pharmaceutical formulation. The present electrodes show clear discrimination of ROX from several inorganic, organic ions, sugars, some common drug excipients and the degradation product (3-[3-(1-piperidinyl methyl) phenoxy] propyl amine) of ROX. Furthermore, the proposed electrodes were utilized for the determination of ROX in human plasma, where electrode B covers drug Cmax which indicated its applicability to pharmacokinetic, bioavailability and bioequivalent studies. The results obtained by the proposed electrodes were statistically analyzed and compared with those obtained by a reported HPLC method. No significant difference for either accuracy or precision was observed. 展开更多
关键词 Comparative study Roxatidine acetate Liquid inner contact electrode Solid contact electrode Degradation product Plasma