The expressions of the second harmonic(2f) signal are derived on the basis of absorption spectral and lock-in theories.A parametric study indicates that the phase shift between the intensity and wavelength modulatio...The expressions of the second harmonic(2f) signal are derived on the basis of absorption spectral and lock-in theories.A parametric study indicates that the phase shift between the intensity and wavelength modulation makes a great contribution to the 2f signal.A self-calibration wavelength modulation spectroscopy(WMS) method based on tunable diode laser absorption spectroscopy(TOLAS) is applied,combining the advantages of ambient pressure,temperature suppression,and phase-shift influences elimination.Species concentration is retrieved simultaneously from selected 2f signal pairs of measured and reference WMS-2f spectra.The absorption line of acetylene(C2H2) at 1530.36 nm near-infrared is selected to detect C2H2 concentrations in the range of 0-400 ppmv.System sensitivity,detection precision and limit are markedly improved,demonstrating that the self-calibration method has better detecting performance than the conventional WMS.展开更多
Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrat...Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and 2.5 kHz respectively to achieve wavelength modulation. The linearity with 0.9907 fitting coefficient is obtained by measuring different concentrations in a 100 ppmv–400 ppmv range. Furthermore, the stability of the system is analyzed by detecting 50 ppmv and 100 ppmv standard gases for 2 h under room temperature and ambient pressure conditions respectively. The precision of 11 ppmv is achieved by calculating the standard deviation. Therefore, the measuring system of C_2H_2 detection can be applied in practical applications.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61172047,61502538,and 61501525)
文摘The expressions of the second harmonic(2f) signal are derived on the basis of absorption spectral and lock-in theories.A parametric study indicates that the phase shift between the intensity and wavelength modulation makes a great contribution to the 2f signal.A self-calibration wavelength modulation spectroscopy(WMS) method based on tunable diode laser absorption spectroscopy(TOLAS) is applied,combining the advantages of ambient pressure,temperature suppression,and phase-shift influences elimination.Species concentration is retrieved simultaneously from selected 2f signal pairs of measured and reference WMS-2f spectra.The absorption line of acetylene(C2H2) at 1530.36 nm near-infrared is selected to detect C2H2 concentrations in the range of 0-400 ppmv.System sensitivity,detection precision and limit are markedly improved,demonstrating that the self-calibration method has better detecting performance than the conventional WMS.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61172047 and 61071025)
文摘Sensitive detection of acetylene(C_2H_2) is performed by absorption spectroscopy and wavelength modulation spectroscopy(WMS) based on Fiber Fabry–Perot tunable filter(FFP-TF) at 1530.32 nm. After being calibrated by Fiber Bragg Grating(FBG), FFP-TF is frequency-multiplexed and modulated at 20 Hz and 2.5 kHz respectively to achieve wavelength modulation. The linearity with 0.9907 fitting coefficient is obtained by measuring different concentrations in a 100 ppmv–400 ppmv range. Furthermore, the stability of the system is analyzed by detecting 50 ppmv and 100 ppmv standard gases for 2 h under room temperature and ambient pressure conditions respectively. The precision of 11 ppmv is achieved by calculating the standard deviation. Therefore, the measuring system of C_2H_2 detection can be applied in practical applications.