期刊文献+
共找到23,063篇文章
< 1 2 250 >
每页显示 20 50 100
Research on Condenser Deterioration Evolution Trend Based on ANP-EWM Fusion Health Degree
1
作者 Hong Qian Haixin Wang +1 位作者 Guangji Wang Qingyun Yan 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第4期679-698,共20页
This study presents a proposed method for assessing the condition and predicting the future status of condensers operating in seawater over an extended period.The aim is to address the problems of scaling and corrosio... This study presents a proposed method for assessing the condition and predicting the future status of condensers operating in seawater over an extended period.The aim is to address the problems of scaling and corrosion,which lead to increased loss of cold resources.The method involves utilising a set of multivariate feature parameters associated with the condenser as input for evaluation and trend prediction.This methodology offers a precise means of determining the optimal timing for condenser cleaning,with the ultimate goal of improving its overall performance.The proposed approach involves the integration of the analytic network process with subjective expert experience and the entropy weightmethod with objective big data analysis to develop a fusion health degreemodel.The mathematical model is constructed quantitatively using the improved Mahalanobis distance.Furthermore,a comprehensive prediction model is developed by integrating the improved Informer model and Markov error correction.This model takes into account the health status of the equipment and several influencing factors,includingmultivariate feature characteristics.This model facilitates the objective examination and prediction of the progression of equipment deterioration trends.The present study involves the computation and verification of the field time series data,which serves to demonstrate the accuracy of the condenser health-related models proposed in this research.These models effectively depict the real condition and temporal variations of the equipment,thus offering a valuable method for determining the precise cleaning time required for the condenser. 展开更多
关键词 condenser health degree improved Mahalanobis distance GC-Informer model Markov error correction
下载PDF
Effect of Heatpipe Array Condenser Section Length on Thermal Cooling of Li-Ion Batteries
2
作者 Olanrewaju M.Oyewola Olawale S.Ismail Adetokunbo A.Awonusi 《Frontiers in Heat and Mass Transfer》 EI 2024年第2期475-490,共16页
One of the new methods for ensuring that the battery in a thermal energy storage system is kept at the proper temperature is the heat pipe-based ThermalManagement System(TMS).In this study,the improvement of cooling p... One of the new methods for ensuring that the battery in a thermal energy storage system is kept at the proper temperature is the heat pipe-based ThermalManagement System(TMS).In this study,the improvement of cooling performance of a heat pipe based TMS is examined through the variation of condenser section length of heat pipes in an array.The TMSs with an array of heat pipes with different condenser section lengths are considered.The system performances are evaluated using a validated numerical method.The results show that a heat pipebased TMS provides the best cooling performance when a wavy-like variation is employed and when the condenser section length of the last set of the heat pipe in the array is greater than that of the penultimate set.The maximum cell temperature and the maximum temperature difference within the cell of this TMS are decreased by 4.2 K and 1.1 K,respectively,when compared to the typical heat pipe based TMS with zero variation in its condenser section length.Conclusively,the strategy offers an improvement in the thermal uniformity for all the TMS cases. 展开更多
关键词 Thermal cooling condenser section length Li-ion battery heatpipe
下载PDF
Nonlinear online process monitoring and fault diagnosis of condenser based on kernel PCA plus FDA 被引量:5
3
作者 张曦 阎威武 +1 位作者 赵旭 邵惠鹤 《Journal of Southeast University(English Edition)》 EI CAS 2007年第1期51-56,共6页
A novel online process monitoring and fault diagnosis method of condenser based on kernel principle component analysis (KPCA) and Fisher discriminant analysis (FDA) is presented. The basic idea of this method is:... A novel online process monitoring and fault diagnosis method of condenser based on kernel principle component analysis (KPCA) and Fisher discriminant analysis (FDA) is presented. The basic idea of this method is: First map data from the original space into high-dimensional feature space via nonlinear kernel function and then extract optimal feature vector and discriminant vector in feature space and calculate the Euclidean distance between feature vectors to perform process monitoring. Similar degree between the present discriminant vector and optimal discriminant vector of fault in historical dataset is used for diagnosis. The proposed method can effectively capture the nonlinear relationship among process variables. Simulating results of the turbo generator's fault data set prove that the proposed method is effective. 展开更多
关键词 NONLINEAR kernel PCA FDA process monitoring fault diagnosis condenser
下载PDF
Development and Application of On-Line Corrosion Monitoring Device for Condenser Tube 被引量:1
4
作者 曹杰玉 宋敬霞 +2 位作者 汪德良 龙国军 孙本达 《Electricity》 2004年第2期31-35,共5页
This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current te... This paper introduces the development and industrial application of an on-line corrosion monitoring device for condenser tubes. Corrosion sensors are made up of representative condenser tubes chosen by eddy current test, which enable the monitoring result to be consistent with the corrosion of actual condenser tubes. Localized corrosion rate of condenser tubes can be measured indirectly by a galvanic couple made up of tube segments with and without pits. Using this technology, corrosion problems can be found in time and accurately, and anticorrosive measures be made more economic and effective. Applications in two power plants showed the corrosion measurements are fast and accurate. 展开更多
关键词 condenser tube CORROSION on-line monitoring INSTRUMENTATION
下载PDF
Air interaction around outdoor air-cooled condensers 被引量:1
5
作者 王树刚 张腾飞 张剑 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期222-226,共5页
In order to increase cooling or heating efficiency,a porous computational fluid dynamics(CFD)model is employed to predict the thermo-fluid status and optimize the placement of outdoor units.A full scale model is est... In order to increase cooling or heating efficiency,a porous computational fluid dynamics(CFD)model is employed to predict the thermo-fluid status and optimize the placement of outdoor units.A full scale model is established to validate the accuracy of CFD simulation in terms of velocity and temperature distributions.The comparison between the measurement and the simulation shows a good agreement.By evaluating the condensers' sucked air temperature with CFD for three units installed in a row,it is found that the minimum separation distance among neighboring units is 0.2 m;a vertical wall should be apart from the unit line by at least 0.8 m;and large different operating pressures among units do not impact the flow rate and the heat transfer of the other units meaningfully. 展开更多
关键词 air-cooled condensers flow interaction heat transfer optimization computational fluid dynamics(CFD) MEASUREMENT
下载PDF
Fabrication of Silicon Condenser Microphone Using Oxidized Porous Silicon as Sacrificial Layer
6
作者 宁瑾 刘忠立 +1 位作者 刘焕章 葛永才 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2003年第5期449-453,共5页
A new technique to fabricate silicon condenser microphone is presented.The technique is based on the use of oxidized porous silicon as sacrificial layer for the air gap and the heavy p+-doping silicon of approximately... A new technique to fabricate silicon condenser microphone is presented.The technique is based on the use of oxidized porous silicon as sacrificial layer for the air gap and the heavy p+-doping silicon of approximately 15μm thickness for the stiff backplate.The measured sensitivity of the microphone fabricated with this technique is in the range from -45dB(5.6mV/Pa) to -55dB(1.78mV/Pa) under the frequency from 500Hz to 10kHz,and shows a gradual increase at higher frequency.The cut-off frequency is above 20kHz. 展开更多
关键词 silicon condenser microphone oxidized porous silicon sacrificial layer
下载PDF
New Model and Simulation of Condenser for Ship Nuclear Power Plant 被引量:2
7
作者 BIAN Xin-Qian, YANG Ben-kun, SHI JiCallege of Power and Nuclear Engineering, Harbin Engineering University, Harbin 150001 , China 《Journal of Marine Science and Application》 2002年第1期35-40,共6页
A new reasonably perfect dynamic mathematic model has been established for condenser used in ship nuclear power plant according to its structural features and operating principle. The model has been solved by the Rung... A new reasonably perfect dynamic mathematic model has been established for condenser used in ship nuclear power plant according to its structural features and operating principle. The model has been solved by the Runge-Kutta method. And an analysis program has been developed for dynamic numerical simulation under steady operation condition, disturbance condition, and accident condition. The dynamic characteristics of condenser has been calculated and analyzed under several kinds of disturbances, and the results of calculation are in good agreement with the theoretical analysis. 展开更多
关键词 condenser dynamic mathematical model Runger Kutta method numerical simulation
下载PDF
Fluid Flow and Convective Heat Transfer in a Water Chemical Condenser 被引量:4
8
作者 Mounir Kriraa Khalid Souhar +2 位作者 Driss Achemlal Youssef Ait Yassine Abdelmajid Farchi 《Fluid Dynamics & Materials Processing》 EI 2020年第2期199-209,共11页
In this paper,a detailed investigation of water(Pr=7.0)convection in a chemical condenser is carried out.Two openings are located along one side of the cavity.The Navier-Stokes equations are solved in the frame of a c... In this paper,a detailed investigation of water(Pr=7.0)convection in a chemical condenser is carried out.Two openings are located along one side of the cavity.The Navier-Stokes equations are solved in the frame of a control volume method using the SIMPLEC algorithm to implement adequate coupling of pressure and velocity.Special emphasis is given to the influence of the Reynolds number,the tilt of the channel and the Rayleigh number on the convective heat transfer.Results are presented and discussed allowing the control parameters to span relatively wide intervals:Rayleigh number(10^(4)≤Ra≤5×10^(5)),channel inclination(0°≤90°)and Reynolds number(10≤Re≤1000).On the basis of these results,a new correlation of the Nusselt number is elaborated. 展开更多
关键词 Chemical condenser tilted channel CONVECTION numerical study heat transfer
下载PDF
Performance Analysis of Automated Control System for Condenser Water Treatment Unit 被引量:3
9
作者 Abdulmajeed Saeed Al-Ghamdi 《Engineering(科研)》 2012年第1期55-67,共13页
The air conditioning system in the Umm Al-Qura University (Albdiya Campus) was conceived to be a district cooling by a remote chilled water plant. Recently, there are two chilled water plants in the university install... The air conditioning system in the Umm Al-Qura University (Albdiya Campus) was conceived to be a district cooling by a remote chilled water plant. Recently, there are two chilled water plants in the university installed strategically to provide chilled water to all the academic and administrative buildings of the university through distribution network with total capacity approximately of 12,000 tons of refrigeration. The plants were built based on cooling towers with open water cycle as heat rejection system. Water treatment chemicals has been used to protect the cooling systems from corrosion, scaling and microbiological fouling accompanied with dissolved and suspended water impurities. Different methods are being used to determine and control the treatment chemical concentrations and system performance indicators. Traditional chemical controller has drawback of indirect measurements and set points. The purpose of this paper is to present a solution to overcome the problems of traditional and conventional chemical treatment and control sys-tems. Central cooling plant number (1) assigned to perform experimental setup using new chemical treatment technology. Advanced automatic chemical treatment controller installed on condensers (1, 2 and 3), and certain key performance indicators were selected and monitored such as chemical and water consumption, power, energy saving, and maintaining system integrity and efficiency. Satisfactory results were obtained in terms of performance and cost of operation. 展开更多
关键词 Chilled WATER Plants condenserS Cooling TOWERS WATER TREATMENT Chemicals Automatic Chemical TREATMENT Controller Performance INDICATORS
下载PDF
Theoretical Analysis of a Shell and Tubes Condenser with R134a Working Refrigerant and Water-Based Oxide of Aluminum Nanofluid (Al<sub>2</sub>O<sub>3</sub>) 被引量:1
10
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2020年第11期1-22,共22页
The article analyzes a shell and tube type condenser’s thermal performance using concepts of efficiency and effectiveness. Freon 134a is used as a coolant flowing through the shell. Water or water-based aluminum oxid... The article analyzes a shell and tube type condenser’s thermal performance using concepts of efficiency and effectiveness. Freon 134a is used as a coolant flowing through the shell. Water or water-based aluminum oxide nanoparticles are at relatively low saturation pressure in the tube. The condenser consists of 36 tubes divided into three central regions for analysis: superheated steam, saturated steam, and subcooled liquid. The three regions contain four tubes with three steps each, that is, 12 tubes. Region I, superheated steam, includes three horizontal baffles. Profiles of temperature, efficiency, and effectiveness are presented graphically for the three regions, with fixed refrigerant flow equal to 0.20 kg/s and fluid flow rate in the tube ranging from 0.05 kg/s to 0.40 kg/s. The experimental result for vapor pressure equal to 1.2 MPa and water flow equal to 0.41 kg/s was used as one of the references for the model’s physical compatibility. 展开更多
关键词 Heat Exchanger condenser Shell and Tubes Freon 134a NANOFLUID
下载PDF
Independent component analysis approach for fault diagnosis of condenser system in thermal power plant 被引量:6
11
作者 Ajami Ali Daneshvar Mahdi 《Journal of Central South University》 SCIE EI CAS 2014年第1期242-251,共10页
A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is t... A statistical signal processing technique was proposed and verified as independent component analysis(ICA) for fault detection and diagnosis of industrial systems without exact and detailed model.Actually,the aim is to utilize system as a black box.The system studied is condenser system of one of MAPNA's power plants.At first,principal component analysis(PCA) approach was applied to reduce the dimensionality of the real acquired data set and to identify the essential and useful ones.Then,the fault sources were diagnosed by ICA technique.The results show that ICA approach is valid and effective for faults detection and diagnosis even in noisy states,and it can distinguish main factors of abnormality among many diverse parts of a power plant's condenser system.This selectivity problem is left unsolved in many plants,because the main factors often become unnoticed by fault expansion through other parts of the plants. 展开更多
关键词 condenser fault detection and diagnosis independent component analysis independent component analysis (ICA) principal component analysis (PCA) thermal power plant
下载PDF
Enhancement of freshwater production of the seawater greenhouse condenser 被引量:1
12
作者 Tahani K BAIT SUWAILAM Abdulrahim M AL-ISMAILI +2 位作者 Nasser A AL-AZRI L H Janitha JEEWANTHA Hemesiri KOTAGAMA 《Journal of Arid Land》 SCIE CSCD 2021年第4期397-412,共16页
Seawater greenhouse(SWGH)is a technology established to overcome issues related to open field cultivation in arid areas,such as the high ambient temperature and the shortage of freshwater.It adopts the humidification-... Seawater greenhouse(SWGH)is a technology established to overcome issues related to open field cultivation in arid areas,such as the high ambient temperature and the shortage of freshwater.It adopts the humidification-dehumidification concept where evaporated moisture from a saline water source is condensed to produce freshwater within the greenhouse body.Various condenser designs are adopted to increase freshwater production in order to meet the irrigation demand.The aim of this study was to experimentally investigate the practicality of using the packed-type direct contact condenser in the SWGH to produce more freshwater at low costs,simple design and high efficiency,and to explore the impact of the manipulating six operational variables(inlet air temperature of the humidifier,air mass flowrate of the humidifier,inlet water temperature of the humidifier,water mass flowrate of the humidifier,inlet water temperature of the dehumidifier and water mass flowrate of the dehumidifier)on freshwater condensation rate.For this purpose,a direct contact condenser was designed and manufactured.Sixty-four full factorial experiments were conducted to study the effect of the six operational variables.Each variable was operated at two levels(high and low flowrate),and each experiment lasted for 10 min and followed by a 30-min waiting time.Results showed that freshwater production varied between 0.257 and 2.590 L for every 10 min.When using Minitab statistical software to investigate the significant variables that contributed to the maximum freshwater production,it was found that the inlet air temperature of the humidifier had the greatest influence,followed by the inlet water temperature of the humidifier;the former had a negative impact while the latter had a positive impact on freshwater production.The response optimizer tool revealed that the optimal combination of variables contributed to maximize freshwater production when all variables were in the high mode and the inlet air temperature of the humidifier was in the low mode.The comparison between the old plastic condenser and the new proposed direct contact condenser showed that the latter can produce 75.9 times more freshwater at the same condenser volume. 展开更多
关键词 seawater greenhouse HUMIDIFICATION-DEHUMIDIFICATION direct contact condenser freshwater production water desalination
下载PDF
METHODS FOR CALCULATING SHELL-SIDE CONDENSATION HEAT TRANSFER AND PRESSURE DROP OF RODBAFFLE CONDENSER
13
作者 思勤 刘昌俊 黄鸿鼎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1996年第1期93-97,共5页
1 INTRODUCTIONGentry,Yong and Small [1-3]have described their Rodbaffle heat exchangers,whichare geometrically shell-and-tube exchangers consisting of a series of shell-side bafflesas an array of supporting rods.The s... 1 INTRODUCTIONGentry,Yong and Small [1-3]have described their Rodbaffle heat exchangers,whichare geometrically shell-and-tube exchangers consisting of a series of shell-side bafflesas an array of supporting rods.The supporting-rod matrix creates an unobstructedflow path and makes the flow field in the shell-side of the heat exchangerpredominantly longitudinal bringing along flow-induced tube vibration in a cross flowheat-exchanger.With neither bundle cross flow form drag nor repeated flow reversal ef-fects being present,the shell-side pressure losses in Rodbaffle heat exchangers are low.Rodbaffle heat exchangers also offer an enhanced thermal performance. 展开更多
关键词 condensATION heat transfer pressure DROP Rodbaffle condenser
下载PDF
A STUDY ON HEAT TRANSFER IN INCLINED REFLUX CONDENSERS
14
作者 李修伦 刘杰 +1 位作者 谷俊杰 黄鸿鼎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1992年第1期39-48,共10页
The condensation heat transfer in the inclined reflux condensers is investigated at various inclinations. A condensation heat transfer model is set up. The calculated values of the model agree well with the experiment... The condensation heat transfer in the inclined reflux condensers is investigated at various inclinations. A condensation heat transfer model is set up. The calculated values of the model agree well with the experimental data. Both the experimental data and the theoretical calculations show that the condensation heat transfer coefficient in the inclined reflux condensers varies with the inclinations and will be maximum when the inclination angle is about 10°. 展开更多
关键词 heat transfer REFLUX condenser INCLINATION condensATION
下载PDF
Evaporative Condensers in Comfortable Air Conditioning System
15
作者 YIN Ying-de1,ZHU Dong-sheng1,DU Gui-mei2,LI Yuan-xi1,SUN He-jing1,LIU Qing-ming1(1.Key Lab of Enhancement Heat Transfer and Energy Conservation,the Ministry of Education,South China University of Technology,Guangzhou,Guangdong 510641,China 2.College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期136-140,共5页
The operating theory of an evaporative condenser was expatiated.The difference between an evaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and th... The operating theory of an evaporative condenser was expatiated.The difference between an evaporative condensing refrigeration system and a general refrigeration system was analyzed.Compared with the air-cooled and the water-cooled,the virtues of energy-conservation and water-conservation of evaporative condensers were analyzed.Some questions existing in the application of evaporative condensers were pointed out,the corresponding solving methods were analyzed accordingly,and the development trend of evaporative condensing technique in mechanical refrigeration system field and the applied foreground of evaporative condensers in comfortable air conditioning were prospected. 展开更多
关键词 EVAPORATIVE condenserS EVAPORATIVE condensing REFRIGERATION SYSTEM general REFRIGERATION SYSTEM comfortable AIR CONDITIONING SYSTEM
下载PDF
A STUDY ON FLOODING VELOCITIES IN INCLINED REFLUX CONDENSERS
16
作者 李修伦 刘杰 +1 位作者 谷俊杰 黄鸿鼎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1992年第1期49-58,共10页
This paper deals with the flooding velocities of the reflux condensers with various inclinations.The flooding phenomena and two-phase flow patterns in such condensers have been observed. A physical and a mathematical ... This paper deals with the flooding velocities of the reflux condensers with various inclinations.The flooding phenomena and two-phase flow patterns in such condensers have been observed. A physical and a mathematical models for calculating flooding velocities are developed, which agree well with the experimental data. The flooding velocity in an inclined reflux condenser varies with the inclination and may reach the maximum value when the inclination is between 30° and 50°. 展开更多
关键词 FLOODING velocity REFLUX condenser INCLINATION
下载PDF
Measurement Methodology for Monitoring Fouling Resistance in Condenser of Chiller
17
作者 YU Dan1,3,GAN Li-si1,CAO Yong2(1.Beijing University of Technology,Beijing 100022,China 2.Build Environment and Energy Efficiency,China Academy of Building Research,Beijing 100013,China 3.Beijing Institute of Civil Engineering and Architecture,Beijing 100044,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期119-122,共4页
This paper established an on-line monitoring model for fouling resistance of cooling water based on heat transfer theory,which was mainly applied to the fouling resistance test for condenser of chiller in operation,an... This paper established an on-line monitoring model for fouling resistance of cooling water based on heat transfer theory,which was mainly applied to the fouling resistance test for condenser of chiller in operation,and the test requirements were presented.It proves that the load ratio of chiller has big influence on the test result,and the best load ratio for test is the range of 80%~100%.A case has been executed to validate the model's feasibility. 展开更多
关键词 FOULING resistance MONITORING condenser COOLING water
下载PDF
Experimental Study of Condensation Heat Transfer on Tube Bundles in Large Power Plant Condensers 被引量:1
18
作者 Koichi Inoue Issaku Fujita +2 位作者 Kotaro Machii Satoshi Hiraoka Manabu Ishihara 《Journal of Energy and Power Engineering》 2014年第5期920-928,共9页
In order to clarify the effect of condensate inundation on steam condensation in a large tube bundle, condensation heat transfer and the condensate flow pattern in the tube bundle have been experimentally investigated... In order to clarify the effect of condensate inundation on steam condensation in a large tube bundle, condensation heat transfer and the condensate flow pattern in the tube bundle have been experimentally investigated. Test tube bundle consists of 36 cooling tubes, 12 condensate supply tubes and 24 un-cooled dummy tubes. Cooling test tubes are made of copper and have an outer diameter of 19.1 mm and condensing length of 150 mm, Steam flows horizontally through the test tube bundle at gap velocities 15-27 m/s at pressures of 8.8 kPa. In this study, experimental data about condensate flow pattern and condensation heat transfer in a tube bundle were collected for the optimization of tube arrangement in large power plant condensers. 展开更多
关键词 condensATION INUNDATION condenser tube bundle tube arrangement power station.
下载PDF
Novel interface engineering of LDH-based materials on Mg alloy for efficient photocatalytic systems considering the geometrical linearity of condensed phosphates 被引量:3
19
作者 Mosab Kaseem Ananda Repycha Safira Arash Fattah-alhosseini 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第1期267-280,共14页
This study presents a facile and rapid method for synthesizing novel Layered Double Hydroxide(LDH)nanoflakes,exploring their application as a photocatalyst,and investigating the influence of condensed phosphates'g... This study presents a facile and rapid method for synthesizing novel Layered Double Hydroxide(LDH)nanoflakes,exploring their application as a photocatalyst,and investigating the influence of condensed phosphates'geometric linearity on their photocatalytic properties.Herein,the Mg O film,obtained by plasma electrolysis of AZ31 Mg alloys,was modified by growing an LDH film,which was further functionalized using cyclic sodium hexametaphosphate(CP)and linear sodium tripolyphosphate(LP).CP acted as an enhancer for flake spacing within the LDH structure,while LP changed flake dispersion and orientation.Consequently,CP@LDH demonstrated exceptional efficiency in heterogeneous photocatalysis,effectively degrading organic dyes like Methylene blue(MB),Congo red(CR),and Methyl orange(MO).The unique cyclic structure of CP likely enhances surface reactions and improves the catalyst's interaction with dye molecules.Furthermore,the condensed phosphate structure contributes to a higher surface area and reactivity in CP@LDH,leading to its superior photocatalytic performance compared to LP@LDH.Specifically,LP@LDH demonstrated notable degradation efficiencies of 93.02%,92.89%,and 88.81%for MB,MO,and CR respectively,over a 40 min duration.The highest degradation efficiencies were observed in the case of the CP@LDH sample,reporting 99.99%for MB,98.88%for CR,and 99.70%for MO.This underscores the potential of CP@LDH as a highly effective photocatalyst for organic dye degradation,offering promising prospects for environmental remediation and water detoxification applications. 展开更多
关键词 Plasma electrolysis Layered Double Hydroxide condensed phosphates Adsorption capacity Photocatalytic efficiency
下载PDF
The Condenser Performance Test and Thermal Performance Analysis of Variable Conditions in TQNPC
20
作者 Qingsen Zhao Debing Deng +4 位作者 Yong Liu Wei Chen Jiayong Wang Jun Xiang Song Hu 《Energy and Power Engineering》 2013年第4期566-569,共4页
Condenser is one of the important auxiliary equipments in nuclear power plants. The thermal efficiency of the entire unit was depended on the condenser performance. Cleanliness factor and condenser corrected pressure ... Condenser is one of the important auxiliary equipments in nuclear power plants. The thermal efficiency of the entire unit was depended on the condenser performance. Cleanliness factor and condenser corrected pressure are the two most important evaluation indexes. The definition and derivation of these two evaluation indexes were elaborated and clarified in this paper. And the condenser performance at variable conditions was analyzed. The seawater temperature, pipe plugging rate and seawater volume rate effect on unit output was calculated. The calculation method was simple, which can provide reference guidance for similar power plant. 展开更多
关键词 condenser PERFORMANCE TEST VARIABLE CONDITION TQNPC
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部