期刊文献+
共找到11,063篇文章
< 1 2 250 >
每页显示 20 50 100
Relative peripheral refraction in school children with different refractive errors using a novel multispectral refraction topographer
1
作者 Hui-Ling Hu Serena Zhe-Chuang Li +3 位作者 Ai-Ying Feng Hao-Xi Zhong Jing-Feng Mu Mei-Zhou Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1477-1482,共6页
AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 e... AIM:To compare relative peripheral refraction(RPR)in Chinese school children with different refractive errors using multispectral refraction topography(MRT).METHODS:A total of 713 eyes of primary school children[172 emmetropia(E),429 low myopia(LM),80 moderate myopia(MM),and 32 low hypermetropia(LH)]aged 10 to 13y were analyzed.RPRs were measured using MRT without mydriasis.MRT results showed RPR at 0-15°(RPR 0-15),15°-30°(RPR 15-30),and 30°-45°(RPR 30-45)annular in the inferior(RPR-I),superior(RPR-S),nasal(RPR-N),and temporal(RPR-T)quadrants.Spherical equivalent(SE)was detected and calculated using an autorefractor.RESULTS:There were significant differences of RPR 15-30 between groups MM[0.02(-0.12;0.18)]and LH[-0.13(-0.36;0.12)](P<0.05),MM and E[-0.06(-0.20;0.10)](P<0.05),and LM[-0.02(-0.15;0.15)]and E(P<0.05).There were also significant differences of RPR 30-45 between groups MM[0.45(0.18;0.74)]and E[0.29(-0.09;0.67)](P<0.05),and LM[0.44(0.14;0.76)]and E(P<0.001).RPR values increased from the hyperopic to medium myopic group in each annular.There were significant differences of RPR-S between groups MM[-0.02(-0.60;0.30)]and E[-0.44(-0.89;-0.04)](P<0.001),and LM[-0.28(-0.71;0.12)]and E(P<0.05).There were also significant differences of RPR-T between groups MM[0.37(0.21;0.78)]and LH[0.14(-0.52;0.50)](P<0.05),LM[0.41(0.06;0.84)]and LH(P<0.05),and LM and E[0.29(-0.10;0.68),P<0.05].A Spearman’s correlation analysis showed a negative correlation between RPR and SE in the 15°-30°(P=0.005),30°-45°(P<0.05)annular(P=0.002),superior(P<0.001),and temporal(P=0.001)quadrants.CONCLUSION:Without pupil dilation,values for RPR 15-30,30-45,RPR-S,and T shows significant differences between myopic eyes and emmetropia,and the differences are negatively correlated with SE. 展开更多
关键词 relative peripheral refraction MYOPIA school children multispectral refraction topography
下载PDF
Reconfigurable mechanism-based metamaterials for ternary-coded elastic wave polarizers and programmable refraction control
2
作者 Zhou HU Zhibo WEI +1 位作者 Yan CHEN Rui ZHU 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第7期1225-1242,共18页
Elastic metamaterials with unusual elastic properties offer unprecedented ways to modulate the polarization and propagation of elastic waves.However,most of them rely on the resonant structural components,and thus are... Elastic metamaterials with unusual elastic properties offer unprecedented ways to modulate the polarization and propagation of elastic waves.However,most of them rely on the resonant structural components,and thus are frequency-dependent and unchangeable.Here,we present a reconfigurable 2D mechanism-based metamaterial which possesses transformable and frequency-independent elastic properties.Based on the proposed mechanism-based metamaterial,interesting functionalities,such as ternarycoded elastic wave polarizer and programmable refraction,are demonstrated.Particularly,unique ternary-coded polarizers,with 1-trit polarization filtering and 2-trit polarization separating of longitudinal and transverse waves,are first achieved.Then,the strong anisotropy of the proposed metamaterial is harnessed to realize positive-negative bi-refraction,only-positive refraction,and only-negative refraction.Finally,the wave functions with detailed microstructures are numerically verified. 展开更多
关键词 elastic metamaterial elastic wave reconfigurable design zero mode ternary code programmable refraction
下载PDF
A robust triaxial localization method of AE source using refraction path
3
作者 Yichao Rui Jie Chen +4 位作者 Jiongkun Chen Jiadong Qiu Zilong Zhou Wenzhong Wang Jinyang Fan 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第4期521-530,共10页
Acoustic emission(AE)localization algorithms based on homogeneous media or single-velocity are less accurate when applied to the triaxial localization experiments.To the end,a robust triaxial localization method of AE... Acoustic emission(AE)localization algorithms based on homogeneous media or single-velocity are less accurate when applied to the triaxial localization experiments.To the end,a robust triaxial localization method of AE source using refraction path is proposed.Firstly,the control equation of the refraction path is established according to the sensor coordinates and arrival times.Secondly,considering the influence of time-difference-of-arrival(TDOA)errors,the residual of the governing equation is calculated to estimate the equation weight.Thirdly,the refraction points in different directions are solved using Snell’s law and orthogonal constraints.Finally,the source coordinates are iteratively solved by weighted correction terms.The feasibility and accuracy of the proposed method are verified by pencil-lead breaking experiments.The simulation results show that the new method is almost unaffected by the refraction ratio,and always holds more stable and accurate positioning performance than the traditional method under different ratios and scales of TDOA outliers. 展开更多
关键词 Acoustic emission(AE) Source localization Robust method refraction paths Weight estimations
下载PDF
Treadmill exercise in combination with acousto-optic and olfactory stimulation improves cognitive function in APP/PS1 mice through the brain-derived neurotrophic factor-and Cygb-associated signaling pathways
4
作者 Biao Xiao Chaoyang Chu +6 位作者 Zhicheng Lin Tianyuan Fang Yuyu Zhou Chuxia Zhang Jianghui Shan Shiyu Chen Liping Li 《Neural Regeneration Research》 SCIE CAS 2025年第9期2706-2726,共21页
A reduction in adult neurogenesis is associated with behavioral abnormalities in patients with Alzheimer's disease.Consequently,enhancing adult neurogenesis represents a promising therapeutic approach for mitigati... A reduction in adult neurogenesis is associated with behavioral abnormalities in patients with Alzheimer's disease.Consequently,enhancing adult neurogenesis represents a promising therapeutic approach for mitigating disease symptoms and progression.Nonetheless,nonpharmacological interventions aimed at inducing adult neurogenesis are currently limited.Although individual non-pharmacological interventions,such as aerobic exercise,acousto-optic stimulation,and olfactory stimulation,have shown limited capacity to improve neurogenesis and cognitive function in patients with Alzheimer's disease,the therapeutic effect of a strategy that combines these interventions has not been fully explored.In this study,we observed an age-dependent decrease in adult neurogenesis and a concurrent increase in amyloid-beta accumulation in the hippocampus of amyloid precursor protein/presenilin 1 mice aged 2-8 months.Amyloid deposition became evident at 4 months,while neurogenesis declined by 6 months,further deteriorating as the disease progressed.However,following a 4-week multifactor stimulation protocol,which encompassed treadmill running(46 min/d,10 m/min,6 days per week),40 Hz acousto-optic stimulation(1 hour/day,6 days/week),and olfactory stimulation(1 hour/day,6 days/week),we found a significant increase in the number of newborn cells(5'-bromo-2'-deoxyuridine-positive cells),immature neurons(doublecortin-positive cells),newborn immature neurons(5'-bromo-2'-deoxyuridine-positive/doublecortin-positive cells),and newborn astrocytes(5'-bromo-2'-deoxyuridine-positive/glial fibrillary acidic protein-positive cells).Additionally,the amyloid-beta load in the hippocampus decreased.These findings suggest that multifactor stimulation can enhance adult hippocampal neurogenesis and mitigate amyloid-beta neuropathology in amyloid precursor protein/presenilin 1 mice.Furthermore,cognitive abilities were improved,and depressive symptoms were alleviated in amyloid precursor protein/presenilin 1 mice following multifactor stimulation,as evidenced by Morris water maze,novel object recognition,forced swimming test,and tail suspension test results.Notably,the efficacy of multifactor stimulation in consolidating immature neurons persisted for at least 2weeks after treatment cessation.At the molecular level,multifactor stimulation upregulated the expression of neuron-related proteins(NeuN,doublecortin,postsynaptic density protein-95,and synaptophysin),anti-apoptosis-related proteins(Bcl-2 and PARP),and an autophagyassociated protein(LC3B),while decreasing the expression of apoptosis-related proteins(BAX and caspase-9),in the hippocampus of amyloid precursor protein/presenilin 1 mice.These observations might be attributable to both the brain-derived neurotrophic factor-mediated signaling pathway and antioxidant pathways.Furthermore,serum metabolomics analysis indicated that multifactor stimulation regulated differentially expressed metabolites associated with cell apoptosis,oxidative damage,and cognition.Collectively,these findings suggest that multifactor stimulation is a novel non-invasive approach for the prevention and treatment of Alzheimer's disease. 展开更多
关键词 acousto-optic stimulation adult neurogenesis Alzheimer's disease amyloid precursor protein/presenilin 1 mice amyloid-beta deposition brain cell apoptosis cognitive impairment depression-like behavior involuntary treadmill exercise olfactory stimulation serum metabolites
下载PDF
Acousto-optic scanning spatial-switching multiphoton lithography 被引量:5
5
作者 Binzhang Jiao Fayu Chen +6 位作者 Yuncheng Liu Xuhao Fan Shaoqun Zeng Qi Dong Leimin Deng Hui Gao Wei Xiong 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2023年第3期597-606,共10页
Nano-3D printing has obtained widespread attention owing to its capacity to manufacture end-use components with nano-scale features in recent years.Multiphoton lithography(MPL)is one of the most promising 3D nanomanuf... Nano-3D printing has obtained widespread attention owing to its capacity to manufacture end-use components with nano-scale features in recent years.Multiphoton lithography(MPL)is one of the most promising 3D nanomanufacturing technologies,which has been widely used in manufacturing micro-optics,photonic crystals,microfluidics,meta-surface,and mechanical metamaterials.Despite of tremendous potential of MPL in laboratorial and industrial applications,simultaneous achievement of high throughput,high accuracy,high design freedom,and a broad range of material structuring capabilities remains a long-pending challenge.To address the issue,we propose an acousto-optic scanning with spatial-switching multispots(AOSS)method.Inertia-free acousto-optic scanning and nonlinear swept techniques have been developed for achieving ultrahigh-speed and aberration-free scanning.Moreover,a spatial optical switch concept has been implemented to significantly boost the lithography throughput while maintaining high resolution and high design freedom.An eight-foci AOSS system has demonstrated a record-high 3D printing rate of 7.6×10^(7)voxel s^(-1),which is nearly one order of magnitude higher than earlier scanning MPL,exhibiting its promise for future scalable 3D nanomanufacturing. 展开更多
关键词 3D nano-printing acousto-optic scanning aberration-free wavefront spatial-switching
下载PDF
Observation of peripheral refraction in myopic anisometropia in young adults 被引量:2
6
作者 Yu-Qin Du Yue-Hua Zhou +3 位作者 Ming-Wei Ding Ming-Xu Zhang Yu-Juan Guo Shan-Shan Ge 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第12期2082-2088,共7页
AIM:To investigate the differences in retinal refraction difference values(RDVs)of adult patients with myopic anisometropia compared with those without myopic anisometropia,and to investigate the relationship between ... AIM:To investigate the differences in retinal refraction difference values(RDVs)of adult patients with myopic anisometropia compared with those without myopic anisometropia,and to investigate the relationship between ocular biometric measurements and relative peripheral refraction.METHODS:This clinical observation study included 130 patients with myopia(-0.25 to-10.00 D)between October 2022 and January 2023 aged between 18 and 40y.The patients were divided into anisometropia(n=63;difference in binocular anisometropia≥1.00 D)and non-anisometropia(n=67;difference in binocular anisometropia<1.00 D)groups accordingly.Ocular biometric measurements were performed by optical biometrics and corneal topography to assess the steep keratometry(Ks),flap keratometry(Kf),axial length(AL),corneal astigmatism(CYL;Ks-Kf),surface regularity index(SRI),surface asymmetry index(SAI),and central corneal thickness(CCT).The RDV was measured at five retinal areas from the fovea to 53 degrees(RDV-0-10,RDV-10-20,RDV-20-30,RDV-30-40,and RDV-40-53),the total RDV(TRDV)of 53 degrees,and four regions,including RDV-superior,RDV-inferior,RDV-temporal,and RDV-nasal.An analysis of Spearman correlation was carried out to examine the correlation between RDV and the spherical equivalent(SE)and ocular biological parameters.RESULTS:Within RDV-20-53,both groups showed relative hyperopic defocus,and the increase in RDV corresponds to the increase in eccentricity.In the myopic anisometropia group,the TRDV,RDV-20-53,RDV-superior,and more myopic eyes had significantly higher RDVtemporal values than less myopic eyes.(P<0.05).In the non-anisometropia group,there was no significant difference in the RDV between the more and less myopic eyes at different eccentricities(P>0.05).There was a negative correlation between SE and TRDV(r=-0.205,P=0.001),RDV-20-53(r=-0.281,-0.183,-0.176,P<0.05),RDV-superior(r=-0.251,P<0.001),and RDV-temporal(r=-0.230,P<0.001),a negative correlation between CYL and RDV-10-30(r=-0.147,-0.180,P<0.05),and a negative correlation between SRI and RDV-0-20(r=-0.190,-0.170,P<0.05).AL had a positive correlation with RDV-20-30(r=0.164,P=0.008)and RDV-temporal(r=0.160,P=0.010).CONCLUSION:More myopic eyes in patients with myopic anisometropia show more peripheral hyperopic defocus.Diopter and corneal morphology may affect peripheral retinal defocus. 展开更多
关键词 MYOPIA ANISOMETROPIA peripheral refraction multispectral refractive topography axial length
下载PDF
Auto-refraction versus subjective refraction in different phakic and pseudophakic conditions:the Tehran Geriatric Eye Study(TGES) 被引量:1
7
作者 Hassan Hashemi Amir Asharlous +3 位作者 Alireza Jamali Abolghasem Mortazavi Alireza Hashemi Mehdi Khabazkhoob 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1309-1316,共8页
AIM:To compare the subjective refraction data with non-cycloplegic auto-refraction findings in the geriatric population above 60 years of age according to the different crystalline lens conditions.METHODS:This report ... AIM:To compare the subjective refraction data with non-cycloplegic auto-refraction findings in the geriatric population above 60 years of age according to the different crystalline lens conditions.METHODS:This report is a part of the Tehran Geriatric Eye Study(TGES)that was conducted from January 2019 to January 2020 on elderly population 60 years of age and above in Tehran.The samples were selected by multistage stratified random cluster sampling.Of 3791 individual invitees,3310(response rate:87.3%)participated in this study.All study participants underwent non-cycloplegic autorefraction(auto-refractometer/keratometer Nidek ARK-510)and subjective refraction.RESULTS:Regarding the sphere,eyes with mixed cataract had the worst limits of agreement(LoA:-1.24 to 0.87)and the best agreement was related to the pseudophakic eyes(LoA:-0.83 to 0.54).The highest(0.27±0.31 D)and lowest(0.21±0.27 D)differences between the two methods regarding the cylinder power were observed in eyes with cortical cataract and normal eyes,respectively.The worst LoA between the two methods in measuring the cylinder power was related to the eyes with mixed cataract(LoA:-0.44 to 0.96).Regarding the J0(horizontal/vertical components of astigmatism),the mean values of J0 obtained by auto-refraction were tended more toward against the rule direction in all crystalline lens conditions,and the two methods had the greatest difference in cortical cataract cases(0.05±0.17 D).Regarding the J45(oblique components of astigmatism),the lowest(0±0.11 D)and highest(-0.01±0.12 D)differences were observed in normal eyes and eyes with cortical cataract,respectively.CONCLUSION:The auto-refractometer/keratometer Nidek ARK-510 results in the elderly with different phakic and pseudophakic conditions do not correspond well with subjective refraction findings.This discrepancy in spherical findings is more pronounced in individuals with mixed cataract than in other cases. 展开更多
关键词 refraction SUBJECTIVE GERIATRIC noncycloplegic autorefraction
下载PDF
High-power xenon lamp-pumped Er:YAP pulse laser operated in free-running and acousto-optical Q-switching modes
8
作者 权聪 孙敦陆 +7 位作者 张会丽 罗建乔 韩志远 乔阳 陈玙威 王镇涛 程毛杰 张庆礼 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期472-476,共5页
We demonstrate a high-energy and high-power pulse laser on a xenon lamp-pumped Er:YAP crystal. The laser performance and thermal focal lengths under different working frequencies are discussed. The results show that t... We demonstrate a high-energy and high-power pulse laser on a xenon lamp-pumped Er:YAP crystal. The laser performance and thermal focal lengths under different working frequencies are discussed. The results show that the thermal lens effect is gradually aggravated with the increase of working frequencies, and even working at 100 Hz, a single pulse energy of 234 m J can be achieved. A maximum average power of 41.5 W is achieved with a working frequency of 20 Hz and slope efficiency of 2.82%. This output power is much higher than other xenon lamp-pumped erbium laser devices.A Q-switched laser is demonstrated by using the TeO2crystal, the maximum output energies of 11.5 m J and 3.5 m J are obtained at 50 and 100 Hz, the corresponding peak powers are 93.4 k W and 17.2 kW, respectively.The laser wavelengths and beam quality factors are also characterized in the free-running and Q-switched modes. A higher pulse energy and peak power laser could be achieved further by improving the damage threshold of TeO2acousto-optical Q-switching. All the experimental results illustrate that the xenon lamp-pumped Er:YAP laser is a promising candidate for high-power and high-frequency mid-infrared laser devices. 展开更多
关键词 Er:YAP crystal xenon lamp-pumped mid-infrared laser acousto-optical Q-switching
下载PDF
Prevalence of visual impairment and estimation of refractive errors among school children in Kakamega,Kenya 被引量:1
9
作者 Isabel Signes-Soler Alfred Ragot +2 位作者 Sheilah Nangena Andrew Wekesa Raúl Montalbán Llamusí 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期932-939,共8页
AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was... AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was cross-sectional.Totally 3343 participants were included in the study.The initial examination involved assessing the uncorrected distance visual acuity(UDVA)and visual acuity(VA)while using a+2.00 D lens.The inclusion criteria for a subsequent comprehensive cycloplegic eye examination,performed by an optometrist,were as follows:a UDVA<0.6 decimal(0.20 logMAR)and/or a VA with+2.00 D≥0.8 decimal(0.96 logMAR).RESULTS:The sample had a mean age of 10.92±2.13y(range 4 to 17y),and 51.3%of the children were female(n=1715).The majority of the children(89.7%)fell within the age range of 8 to 14y.Among the ethnic groups,the highest representation was from the Luhya group(60.6%)followed by Luo(20.4%).Mean logMAR UDVA choosing the best eye for each student was 0.29±0.17(range 1.70 to 0.22).Out of the total,246 participants(7.4%)had a full eye examination.The estimated prevalence of myopia(defined as spherical equivalent≤-0.5 D)was found to be 1.45%of the total sample.While around 0.18%of the total sample had hyperopia value exceeding+1.75 D.Refractive astigmatism(cil<-0.75 D)was found in 0.21%(7/3343)of the children.The VI prevalence was 1.26%of the total sample.Among our cases of VI,76.2%could be attributed to uncorrected refractive error.Amblyopia was detected in 0.66%(22/3343)of the screened children.There was no statistically significant correlation observed between age or gender and refractive values.CONCLUSION:The primary cause of VI is determined to be uncorrected refractive errors,with myopia being the most prevalent refractive error observed.These findings underscore the significance of early identification and correction of refractive errors in school-aged children as a means to alleviate the impact of VI. 展开更多
关键词 visual impairment refractive errors MYOPIA AMBLYOPIA sustainable development goals
下载PDF
Unidirectional Negative Refraction at an Exceptional Point of Acoustic P T-Symmetric Systems
10
作者 刘宸 蓝君 +1 位作者 顾仲明 祝捷 《Chinese Physics Letters》 SCIE EI CAS CSCD 2023年第12期56-61,共6页
We demonstrate a method to realize unidirectional negative refraction in an acoustic parity-time(P T)-symmetric system, which is composed of a pair of metasurfaces sandwiching an air gap. The pair of metasurfaces poss... We demonstrate a method to realize unidirectional negative refraction in an acoustic parity-time(P T)-symmetric system, which is composed of a pair of metasurfaces sandwiching an air gap. The pair of metasurfaces possesses loss and gain modulations. The unidirectional negative refraction, which is strictly limited to the case of incident wave imposing on the loss end of the metasurface, is demonstrated at the exception point(EP) in this P T-symmetric system, while the incidence from the other side leads to strong reflection. Based on rigorous calculations, we explicitly show the underlying mechanism of this model to achieve unidirectional wave scatterings around the EP in the parametric space. In addition, the perfect imaging of a point source in the three-dimensional space, as a signature of negative refraction, is simulated to provide a verification of our work. We envision that this work may sharpen the understanding of P T-symmetric structures and inspire more acoustic functional devices. 展开更多
关键词 refraction UNIDIRECTIONAL SYMMETRIC
下载PDF
Nonreciprocal negative refraction in a dense hot atomic medium
11
作者 易海 张红军 孙辉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期50-57,共8页
We investigate the electromagnetic properties of a four-level dense atomic gas medium with Doppler effect.It is shown that the relative permittivity and relative permeability of the medium can be negative simultaneous... We investigate the electromagnetic properties of a four-level dense atomic gas medium with Doppler effect.It is shown that the relative permittivity and relative permeability of the medium can be negative simultaneously with low absorption in the same detuning interval on account of electromagnetically induced transparency.Furthermore,with the suitable parameters,the nonreciprocal negative refraction can be obtained due to the Doppler effect,and the nonreciprocity frequency band can be regulated by adjusting the temperature,the intensity of the control field and the atomic density in this hot atomic medium. 展开更多
关键词 negative refraction NONRECIPROCITY Doppler effect atomic system
下载PDF
Development of miniaturized SAF-LIBS with high repetition rate acousto-optic gating for quantitative analysis
12
作者 陈斐 侯佳佳 +10 位作者 王刚 赵洋 李佳轩 王树青 张雷 张婉飞 马晓飞 刘珍荣 罗学彬 尹王保 贾锁堂 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期157-164,共8页
The self-absorption effect in laser-induced breakdown spectroscopy(LIBS)reduces the accuracy of quantitative measurement results.The self-absorption-free LIBS(SAF-LIBS)has been proved to directly capture the optically... The self-absorption effect in laser-induced breakdown spectroscopy(LIBS)reduces the accuracy of quantitative measurement results.The self-absorption-free LIBS(SAF-LIBS)has been proved to directly capture the optically thin plasma spectra by setting an appropriate exposure time.In this work,a novel SAF-LIBS technique with high repetition rate acousto-optic gating is developed,in which an acousto-optic modulator is used as the shutter to diffract the optically thin fluorescence,and a high repetition rate laser is used to produce quasi-continuous plasmas to enhance the integral spectral intensity,so that the CCD spectrometer can replace an intensified CCD(ICCD)and echelle spectrometer in SAF-LIBS.Experimental results show that the average absolute prediction error of aluminum is reduced to 0.18%,which is equivalent to that of traditional SAF-LIBS.This technique not only effectively shields continuous background radiation and broadened spectral lines in optically thick plasma,but also has advantages of miniaturization,low cost,convenience and reliability. 展开更多
关键词 self-absorption-free LIBS(SAF-LIBS) self-absorption effect optically thin plasma high repetition rate laser acousto-optic gating
下载PDF
Prevalence of Refractive Errors among School Children Aged 5 to 15 Years Old at CHU-IOTA
13
作者 Kadiatou Ba Aichata Tall +19 位作者 Mory Coulibaly Cheick Sogodogo Zoumana Bagayogo Aoua Ibrahim Toure Ousmane Toure Brainima Coulibaly Fatoumata Tata Sidibe Aly Konipo Roucky Sangare Seydou Diallo Moro Sidibe Oumar Diallo Assiatou Simaga Gounon Saye Modibo Sissoko Mamadou Kole Sidibe Sidi Diarra Nouhoum Guirou Abdoulaye Napo Adama Guindo 《Surgical Science》 2024年第8期480-491,共12页
Introduction: Undetected refractive errors constitute a health problem among school children who cannot take advantage of educational opportunities. The authors studied the prevalence of refractive errors in school ch... Introduction: Undetected refractive errors constitute a health problem among school children who cannot take advantage of educational opportunities. The authors studied the prevalence of refractive errors in school children aged 5 to 15 at CHU-IOTA. Patients and Method: This is a prospective, descriptive cross-sectional study carried out in the ophthalmic-pediatrics department of CHU-IOTA, from October to November 2023. Results: We received 340 school children aged 5 to 15, among whom 111 presented ametropia, i.e. a prevalence of 32.65%. The average age was 11.42 ± 2.75 years and a sex ratio of 0.59. The average visual acuity was 4/10 (range 1/10 and 10/10). We found refractive defects: astigmatism 73.87%, hyperopia 23.87% of cases and myopia 2.25%. The decline in distance visual acuity was the most common functional sign. Ocular abnormalities associated with ametropia were dominated by allergic conjunctivitis (26.13%) and papillary excavation (6.31%) in astigmatics;allergic conjunctivitis (9.01%) and papillary excavation (7.20%) in hyperopic patients;turbid vitreous (0.90%), myopic choroidosis (0.45%) and allergic conjunctivitis (0.45%) in myopes. Conclusion: Refractive errors constitute a reality and a major public health problem among school children. 展开更多
关键词 refractive Errors PREVALENCE CHILD CHU-IOTA
下载PDF
A Transparent Photoresist Made of Titanium Dioxide Nanoparticle-Embedded Acrylic Resin with a Tunable Refractive Index for UV-Imprint Lithography
14
作者 Yinglu Liu Dan Wang +7 位作者 Changlin Liu Qianqian Hao Jian Li Jie-Xin Wang Xiuyun Chen Peng Zhong Xibin Shao Jian-Feng Chen 《Engineering》 SCIE EI CAS CSCD 2024年第6期96-104,共9页
Transparent photoresists with a high refractive index(RI)and high transmittance in visible wavelengths have promising functionalities in optical fields.This work reports a kind of tunable optical material composed of ... Transparent photoresists with a high refractive index(RI)and high transmittance in visible wavelengths have promising functionalities in optical fields.This work reports a kind of tunable optical material composed of titanium dioxide nanoparticles embedded in acrylic resin with a high RI for ultraviolet(UV)-imprint lithography.The hybrid film exhibits a tunable RI of up to 1.67(589 nm)after being cured by UV light,while maintaining both a high transparency of over 98%in the visible light range and a low haze of less than 0.05%.The precision machining of optical microstructures can be imprinted easily and efficiently using the hybrid resin,which acts as a light guide plate(LGP)to guide the light from the side to the top in order to conserve the energy of the display device.These preliminary studies based on both laboratory and commercial experiments pave the way for exploiting the unparalleled optical properties of nanocomposite resins and promoting their industrial application. 展开更多
关键词 PHOTORESIST Tunable refractive index Hanson solubility Ultraviolet imprint Organic-inorganic composites
下载PDF
Two different autorefractors for vision screening in children and adolescents
15
作者 Xiao-Jun Chen Lin-Jie Liu +5 位作者 Bing Sun Dan-Dan Jiang Shu-Shu Zuo Yan-Hui Wang Chun-Hua Zhang Yan-Yan Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期331-338,共8页
AIM:To compare the consistency of two autorefractors(Tianle RM-9000 and Topcon KR-800)for school-age myopia children,and to provide a basis for largescale data analysis and comparison.METHODS:The refractive error in 9... AIM:To compare the consistency of two autorefractors(Tianle RM-9000 and Topcon KR-800)for school-age myopia children,and to provide a basis for largescale data analysis and comparison.METHODS:The refractive error in 909 subjects(age 4–18y)were measured using both autorefractors without cycloplegia.The data were analyzed using Fourier decomposition and the correlation coefficients,intraclass correlation coefficients(ICC),and Bland-Altman limits of agreement(LoA)for each parameter were calculated.RESULTS:There was a strong correlation between the spherical equivalent(SE),sphere diopter(DS),and cylinder diopter(DC)readings of the Tianle RM-9000 and those of the Topcon KR-800,with correlation coefficient values of 0.98,0.98 and 0.83 and ICC values of 0.99,0.99 and 0.93,respectively.However,the correlation coefficients and ICC values of J0 and J45 were unreliable(R=-0.004,-0.034;both ICC<0.10).Bland-Altman analysis revealed that SE,DS,and DC measured by the Tianle RM-9000 were significantly biased toward myopia compared with the Topcon KR-800,and the mean differences were-0.072,-0.026,-0.091 D,respectively(all P<0.01).The minimum absolute value of the difference within the 95%LoA for SE,DS,and DC was 0.63 D,0.50 D,0.62 D,respectively;all these values were in the clinically acceptable range.For J0 and J45,the mean differences were close to zero(P=0.43,0.84);however,the 95%LoA were relatively wide(J0 SD:0.53;95%CI:-1.00,1.10;J45 SD:0.52;95%CI:-1.00,1.00).CONCLUSION:The two autorefractors are consistent with each other,as the differences in SE,DS,and DC were within the clinically acceptable range.Readers can compare the data measured by either device in different studies and use the two devices in the same study to generate a dataset that can be analyzed together.However,the J0 and J45 vectors are unreliable and should not be used to assess astigmatism. 展开更多
关键词 refractive error autorefractors school-age myopia children
下载PDF
Surface phonon resonance:A new mechanism for enhancing photonic spin Hall effect and refractive index sensor
16
作者 程杰 汪承龙 +3 位作者 李一铭 张亚林 刘胜利 董鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期254-261,共8页
Metal-based surface plasmon resonance(SPR)plays an important role in enhancing the photonic spin Hall effect(SHE)and developing sensitive optical sensors.However,the very large negative permittivities of metals limit ... Metal-based surface plasmon resonance(SPR)plays an important role in enhancing the photonic spin Hall effect(SHE)and developing sensitive optical sensors.However,the very large negative permittivities of metals limit their applications beyond the near-infrared regime.In this work,we theoretically present a new mechanism to enhance the photonic SHE by taking advantage of SiC-supported surface phonon resonance(SPhR)in the mid-infrared regime.The transverse displacement of photonic SHE is very sensitive to the wavelength of incident light and the thickness of SiC layer.Under the optimal parameter setup,the calculated largest transverse displacement of SiC-based SPhR structure reaches up to 163.8 ym,which is much larger than the condition of SPR.Moreover,an NO_(2) gas sensor based on the SPhR-enhanced photonic SHE is theoretically proposed with the superior sensing performance.Both the intensity and angle sensitivity of this sensor can be effectively manipulated by varying the damping rate of SiC.The results may provide a promising paradigm to enhance the photonic SHE in the mid-infrared region and open up new opportunity of highly sensitive refractive index sensors. 展开更多
关键词 photonic spin Hall effect refractive index sensor surface phonon resonance SIC
下载PDF
Fabrication of UV-Curing Linalool-Polysiloxane Hybrid Films with High Refractive Index and Transparency
17
作者 Wenqing Xiao Lewen Tan +2 位作者 Xunjun Chen Qiaoguang Li Yunqing Ruan 《Journal of Renewable Materials》 EI CAS 2024年第3期569-583,共15页
In this article,a series of high refractive indices(1.50-1.53)thiol phenyl polysiloxane(TPS)were synthesized via hydrolytic sol-gel reaction.The Fourier transform infrared spectra(FT-IR)and nuclear magnetic resonance ... In this article,a series of high refractive indices(1.50-1.53)thiol phenyl polysiloxane(TPS)were synthesized via hydrolytic sol-gel reaction.The Fourier transform infrared spectra(FT-IR)and nuclear magnetic resonance spectra(NMR)results showed that TPS conformed to the predicted structures.Natural terpene linalool was exploited as photocrosslinker to fabricate UV-curing linalool-polysiloxane hybrid films(LPH)with TPS via photoinitiated thiol-ene reaction.LPH rapidly cured under UV irradiation at the intensity of 80 mW/cm^(2) in 30 s,exhibiting good UV-curing properties.The optical transmittance of LPH in the wavelength of 300-800 nm was over 90%,exhibiting good optical transparency.The water contact angle and water vapor permeability results showed that the introduction of phenyl groups enhance the hydrophobicity and water vapor barrier properties of LPH.The results indicated the potential of LPHs in the applications of optical functional coatings. 展开更多
关键词 UV-CURING polysiloxane hybrid films high refractive index TRANSPARENCY
下载PDF
Prevalence and Factors Associated with Refractive Errors among University Students at Mbarara University of Science and Technology, Uganda
18
作者 Denis Kamara John Onyango +5 位作者 Simon Arunga Mwanja Pius Pliers Denis Tusingwire Mary Assumpta Ayoo Eric Ronald Mulongo Barnabas Atwiine 《Open Journal of Ophthalmology》 2024年第3期324-338,共15页
Introduction: WHO estimated that uncorrected refractive errors are the leading cause of visual impairment and second leading cause of blindness globally. University students are prone to developing refractive errors d... Introduction: WHO estimated that uncorrected refractive errors are the leading cause of visual impairment and second leading cause of blindness globally. University students are prone to developing refractive errors due to their curriculum that requires a lot of near work affecting their performance and quality of life unknowingly. Genetic and environmental factors are thought to play a role in the development of refractive errors. This study addresses the paucity of knowledge about refractive errors among university students in East Africa, providing a foundation for further research. Objectives: To determine the prevalence and factors associated with refractive errors among students in the Faculty of Medicine at Mbarara University of Science and Technology. Methodology: This was a cross-sectional descriptive and analytical study in which 368 undergraduate students selected using random sampling were assessed for refractive errors from March 2021-July 2021. Eligible participants were recruited and their VA assessment done after answering a questionnaire. Students whose VA improved on pin hole had subjective retinoscopy and results were compiled and imported to STATA 14 for analysis. Results: The prevalence of refractive errors was 26.36% with (95% CI) among university students especially myopia. Myopia is most predominant at 60%, followed by 37% Astigmatism and hyperopia of 3% among medical students. Astigmatism consisted of largely myopic astigmatism 72% (26) and 28% (10) compound/mixed astigmatism only. Student positive family history of refractive error was found to have a statistically significant relationship with refractive errors with AOR 1.68 (1.04 - 2.72) (95% CI) and P (0.032). Conclusion: The prevalence of refractive errors among university students, especially myopia, was found to be high and family history was associated with students having refractive errors. 展开更多
关键词 refractive Errors PREVALENCE Myopia ASTIGMATISM HYPEROPIA HYPERMETROPIA UNIVERSITY Students BLINDNESS Visual Impairment
下载PDF
Relative peripheral refractive errors in Chinese children with myopic anisometropia
19
作者 Yu-Ting Tong Yu-Qin Du +4 位作者 Shan-Shan Ge Li Chen Xiao-Qi Ma Yu-Juan Guo Yue-Hua Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第11期2074-2081,共8页
AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-section... AIM:To compare relative peripheral refractive errors(RPREs)in Chinese children with and without myopic anisometropia(MAI)and to explore the relationship between RPRE and myopia.METHODS:This observational cross-sectional study included 160 children divided into two groups according to the interocular spherical equivalent refraction(SER)difference≥1.0 D in the MAI group(n=80)and<1.0 D in the non-MAI group(n=80).The MAI group was further divided into two subgroups:ΔSER<2.0 D group and ΔSER≥2.0 D group.Basic ocular biometric parameters of axial length(AL),average keratometry(Ave K),cylinder(CYL),surface regularity index(SRI),and surface asymmetry index(SAI)were recorded.In addition,multispectral refraction topography was performed to measure RPRE,and the parameters were recorded as total refraction difference value(TRDV),refraction difference value(RDV)0-10,RDV10-20,RDV20-30,RDV30-40,RDV40-53,RDV-superior(RDV-S),RDV-inferior(RDV-I),RDV-temporal(RDV-T)and RDV-nasal(RDV-N).RESULTS:In the non-MAI group,the interocular differences of all parameters of RPRE were not significant.In the MAI group,the interocular differences of TRDV,RDV10-53,RDV-S,RDV-I,RDV-T,and RDV-N were significant.In subgroup analysis,the interocular differences of TRDV,RDV30-53,RDV-I,and RDV-T were significant in ΔSER<2.0 D group and ΔSER≥2.0 D group,but the interocular differences of RDV10-30,RDV-S and RDV-N were only significant in the ΔSER≥2.0 D group.In correlation analysis,ΔTRDV,ΔRDV 10-53,ΔRDV-S,and ΔRDV-N were negatively correlated with ΔSER but positively correlated with ΔAL.CONCLUSION:The more myopic eyes have larger hyperopic RPRE in Chinese children with MAI in certain retinal range,and partialΔRPRE is closely associated with ΔSER and ΔAL. 展开更多
关键词 MYOPIA ANISOMETROPIA relative peripheral refractive error ocular biometric parameters
下载PDF
Determination of the time of refractive stability after uneventful phacoemulsification in Indian eyes
20
作者 Ashok Kumar Nanda Bijnya Birajita Panda +1 位作者 Asish Swain Logesh Balakrishnan 《World Journal of Experimental Medicine》 2024年第2期89-96,共8页
BACKGROUND Knowledge about refractive stabilization and the accuracy of postoperative refractive error measurements are crucial for improved patient outcomes after phacoemulsification.Existing guidelines typically rec... BACKGROUND Knowledge about refractive stabilization and the accuracy of postoperative refractive error measurements are crucial for improved patient outcomes after phacoemulsification.Existing guidelines typically recommend waiting 4-6 wk before prescribing corrective lenses.Our research focused on identifying factors that influence refractive errors in the early stages of post-cataract surgery,thus contributing to the existing literature on this topic.AIM To investigate the time required for refraction stability after uneventful phacoemulsification surgery.METHODS We compared the variation and statistical significance of the difference in spherical,cylindrical components,and the spherical equivalent between the 1-and 6-wk follow-up period in a group of 257 eyes that underwent uneventful phacoemulsification with foldable intraocular lens implantation,all performed by a single experienced surgeon.The Wilcoxon-Signed Rank Test was utilized to assess the magnitude of the change and determine its statistical significance.The refractive stability was defined as the point at which the change in spherical equivalent was within±0.5 dioptres for two consecutive visits.RESULTS The average age of the patients was 64.9±8.9 yr.The differences observed in both the visits in spherical power(0.1±0.2),cylinder power(0.3±0.4),and spherical equivalent(0.2±0.2)were minimal and not statistically significant.The majority of eyes(93.4%)achieved refractive stability within 6 wk after the surgery.The cylindrical power differed between age groups at the 6th wk post-operative and the difference was statistically significant(P value 0.013).There were no significant differences in refractive stability when considering sex and axial length.CONCLUSION Phacoemulsification with foldable intraocular lens implantation results in no significant changes in refraction for the majority of cases during the 6-wk follow-up period.Therefore,a spectacle prescription can be given at the completion of 1 wk. 展开更多
关键词 Cataract surgery PHACOEMULSIFICATION refraction stability Visual acuity Spherical equivalent
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部