A multi-modal action control approach is proposed for an autonomous soccer robot when the bottom hardware is unchangeable. Different from existing methods, the proposed control approach defines actions with the princi...A multi-modal action control approach is proposed for an autonomous soccer robot when the bottom hardware is unchangeable. Different from existing methods, the proposed control approach defines actions with the principle of "perception-planning-action" inspired by human intelligence. Character extraction is used to divide the perception input into different modes. Different control modes are built by combining different control methods for the linear velocity and angular velocity. Based on production rules, the motion control is realized by connecting different perceptions to the corresponding control mode. Simulation and real experiments are conducted with the middle-sized robot Frontier-I, and the proposed method is compared with a proportional-integral-derivative (PID) control method to display its feasibility and performance. The results show that the multi-modal action control method can make robots react rapidly in a dynamic environment.展开更多
Purpose: To test the concept of Statistical Process Control (SPC) as a Quality Assurance (QA) procedure for dose verifications in external beam radiation therapy in conventional and 3D Conformal Radiotherapy (3D-CRT) ...Purpose: To test the concept of Statistical Process Control (SPC) as a Quality Assurance (QA) procedure for dose verifications in external beam radiation therapy in conventional and 3D Conformal Radiotherapy (3D-CRT) treatment of cervical cancer. Materials and Methods: A study of QA verification of target doses of 198 cervical cancer patients undergoing External Beam Radiotherapy (EBRT) treatments at two different cancer treatment centers in Kenya was conducted. The target doses were determined from measured entrance doses by the diode in vivo dosimetry. Process Behavior Charts (PBC) developed by SPC were applied for setting Action Thresholds (AT) on the target doses. The AT set was then proposed as QA limits for acceptance or rejection of verified target doses overtime of the EBRT process. Result and Discussion: Target doses for the 198 patients were calculated and SPC applied to test whether the action limits set by the Process Behavior Charts could be applied as QA for verified doses in EBRT. Results for the two sub-groups of n = 3 and n = 4 that were tested produced action thresholds which are within clinical dose specifications for both conventional AP/PA and 3D-CRT EBRT treatment techniques for cervical cancer. Conclusion: Action thresholds set by SPC were within the clinical dose specification of ±5% uncertainty for both conventional AP/PA and 3D-CRT EBRT treatment techniques for cervical cancer. So the concept of SPC could be applied in setting QA action limits for dose verifications in EBRT.展开更多
This paper provides a solution to generalize the integrator and the integral control action. It is achieved by defining two function sets to generalize the integrator and the integral control action, respectively, res...This paper provides a solution to generalize the integrator and the integral control action. It is achieved by defining two function sets to generalize the integrator and the integral control action, respectively, resorting to a stabilizing controller and adopting Lyapunov method to analyze the stability of the closed-loop system. By originating a powerful Lyapunov function, a universal theorem to ensure regionally as well as semi-globally asymptotic stability is established by some bounded information. Consequently, the justification of two propositions on the generalization of integrator and integral control action is verified. Moreover, the conditions used to define the function sets can be viewed as a class of sufficient conditions to design the integrator and the integral control action, respectively.展开更多
基金supported by National Natural Science Foundation of China (No.60443004)Science and Technology Project of CQ Education Committee (No.KJ080621)
文摘A multi-modal action control approach is proposed for an autonomous soccer robot when the bottom hardware is unchangeable. Different from existing methods, the proposed control approach defines actions with the principle of "perception-planning-action" inspired by human intelligence. Character extraction is used to divide the perception input into different modes. Different control modes are built by combining different control methods for the linear velocity and angular velocity. Based on production rules, the motion control is realized by connecting different perceptions to the corresponding control mode. Simulation and real experiments are conducted with the middle-sized robot Frontier-I, and the proposed method is compared with a proportional-integral-derivative (PID) control method to display its feasibility and performance. The results show that the multi-modal action control method can make robots react rapidly in a dynamic environment.
文摘Purpose: To test the concept of Statistical Process Control (SPC) as a Quality Assurance (QA) procedure for dose verifications in external beam radiation therapy in conventional and 3D Conformal Radiotherapy (3D-CRT) treatment of cervical cancer. Materials and Methods: A study of QA verification of target doses of 198 cervical cancer patients undergoing External Beam Radiotherapy (EBRT) treatments at two different cancer treatment centers in Kenya was conducted. The target doses were determined from measured entrance doses by the diode in vivo dosimetry. Process Behavior Charts (PBC) developed by SPC were applied for setting Action Thresholds (AT) on the target doses. The AT set was then proposed as QA limits for acceptance or rejection of verified target doses overtime of the EBRT process. Result and Discussion: Target doses for the 198 patients were calculated and SPC applied to test whether the action limits set by the Process Behavior Charts could be applied as QA for verified doses in EBRT. Results for the two sub-groups of n = 3 and n = 4 that were tested produced action thresholds which are within clinical dose specifications for both conventional AP/PA and 3D-CRT EBRT treatment techniques for cervical cancer. Conclusion: Action thresholds set by SPC were within the clinical dose specification of ±5% uncertainty for both conventional AP/PA and 3D-CRT EBRT treatment techniques for cervical cancer. So the concept of SPC could be applied in setting QA action limits for dose verifications in EBRT.
文摘This paper provides a solution to generalize the integrator and the integral control action. It is achieved by defining two function sets to generalize the integrator and the integral control action, respectively, resorting to a stabilizing controller and adopting Lyapunov method to analyze the stability of the closed-loop system. By originating a powerful Lyapunov function, a universal theorem to ensure regionally as well as semi-globally asymptotic stability is established by some bounded information. Consequently, the justification of two propositions on the generalization of integrator and integral control action is verified. Moreover, the conditions used to define the function sets can be viewed as a class of sufficient conditions to design the integrator and the integral control action, respectively.