PASSIVE-ACTIVE CONTROL OF A FLEXIBLE ISOLATION SYSTEM
1
作者 Song KongjieZhang BingSun LinglingSun YuguoSchool of Mechanical Engineering, Shandong University, Jinan 250061, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2003年第4期408-410,416,共4页
Passive-active control of a flexible isolation system is investigated from the viewpoint of power flow. Dynamic transfer equations of the system are deduced based on a matrix method which uses mobility or impedance re... Passive-active control of a flexible isolation system is investigated from the viewpoint of power flow. Dynamic transfer equations of the system are deduced based on a matrix method which uses mobility or impedance representations of three substructures: the source of vibration, the receiver and the mounting system which connects the source to the receiver. The cancellation of axial input forces to the receiver is considered as the active control strategy and its effects are discussed. The results of the study show that the strategy adopted herein can effectively reduce the power transmitted to the receiver. 展开更多
关键词 Flexible isolation system Power flow active control
下载PDF
DOUBLE LOOP ACTIVE VIBRATION CONTROL OF PNEUMATIC ISOLATOR WITH TWO SEPARATE CHAMBERS
2
作者 YANG Qingjun LI Jun WANG Zuwen 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2006年第4期610-613,共4页
A newly designed pneumatic spring with two separate chambers is promoted and double-loop active control is introduced to overcome the following drawbacks of passive pneumatic isolation: ① The low frequency resonance... A newly designed pneumatic spring with two separate chambers is promoted and double-loop active control is introduced to overcome the following drawbacks of passive pneumatic isolation: ① The low frequency resonances introduced into the system; ② Conflict between lower isolation frequency and stiffness high enough to limit quasi-static stroke;③ Inconsistent isolation level with different force load. The design of two separate chambers is for the purpose of tuning support frequency and force independently and each chamber is controlled by a different valve. The inner one of double-loop structure is pressure control, and in order to obtain good performance, nonlinearities compensation and motion flow rate compensation (MFRC) are added besides the basic cascade compensation, and the influence of tube length is studied. The outer loop has two functions: one is to eliminate the resonance caused by isolation support and to broaden the isolation frequency band by payload velocity feedback and base velocity feed forward, and the other is to tune support force and support stiffness simultaneously and independently, which means the support force will have no effect on support stiffness. Theoretical analysis and experiment results show that the three drawbacks are overcome simultaneously. 展开更多
关键词 Pneumatic isolator active vibration control Double-loop control Two separate chambers Mass flow rate compensation (MFRC)
下载PDF
Simplified performance indices and active control force of vibration isolation systems with elastic base
3
作者 SUN Hongling 《Chinese Journal of Acoustics》 CSCD 2018年第1期69-88,共20页
Influence of the elasticity of the base on vibration isolation performances of single layer, double layer and floating raft vibration isolation systems is investigated systematically. Characteristics of vibration coup... Influence of the elasticity of the base on vibration isolation performances of single layer, double layer and floating raft vibration isolation systems is investigated systematically. Characteristics of vibration coupling between different vibration isolation systems and different elastic bases are analyzed. Moreover the characteristics of vibration acceleration level difference and force transmissibility of different vibration isolation systems are discussed and their simpli- fled expressions are given. In addition the required control forces of active vibration isolation under different installations of actuators for different vibration isolation systems are compared. The results show that for all vibration isolation systems, the addition of the stiffness and damping of the base can enhance their vibration acceleration level difference and force transmissibility. Moreover for floating raft vibration isolation system, the addition of the stiffness and damping of the raft can enhance its vibration isolation performance and reduce the control force required bv active vibration isolation. 展开更多
关键词 In Simplified performance indices and active control force of vibration isolation systems with elastic base
原文传递