期刊文献+
共找到11,431篇文章
< 1 2 250 >
每页显示 20 50 100
Factors Influencing the Spatial Variability of Air Temperature Urban Heat Island Intensity in Chinese Cities
1
作者 Heng LYU Wei WANG +3 位作者 Keer ZHANG Chang CAO Wei XIAO Xuhui LEE 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2024年第5期817-829,共13页
Few studies have investigated the spatial patterns of the air temperature urban heat island(AUHI)and its controlling factors.In this study,the data generated by an urban climate model were used to investigate the spat... Few studies have investigated the spatial patterns of the air temperature urban heat island(AUHI)and its controlling factors.In this study,the data generated by an urban climate model were used to investigate the spatial variations of the AUHI across China and the underlying climate and ecological drivers.A total of 355 urban clusters were used.We performed an attribution analysis of the AUHI to elucidate the mechanisms underlying its formation.The results show that the midday AUHI is negatively correlated with climate wetness(humid:0.34 K;semi-humid:0.50 K;semi-arid:0.73 K).The annual mean midnight AUHI does not show discernible spatial patterns,but is generally stronger than the midday AUHI.The urban–rural difference in convection efficiency is the largest contributor to the midday AUHI in the humid(0.32±0.09 K)and the semi-arid(0.36±0.11 K)climate zones.The release of anthropogenic heat from urban land is the dominant contributor to the midnight AUHI in all three climate zones.The rural vegetation density is the most important driver of the daytime and nighttime AUHI spatial variations.A spatial covariance analysis revealed that this vegetation influence is manifested mainly through its regulation of heat storage in rural land. 展开更多
关键词 air temperature urban heat island spatial variations biophysical drivers Chinese cities climate model
下载PDF
Mathematical Modelling and Design of Helical Coil Heat Exchanger for Production of Hot Air for Fluidized Bed Dryer
2
作者 Iniubong James Uwa Uwem Ekwere Inyang Innocent Oseribho Oboh 《Advances in Chemical Engineering and Science》 CAS 2024年第3期125-136,共12页
In global industrialization, efforts have been made to increase the rate of heat transfer in heat exchanger, minimizing the size of heat exchanger to reduce cost as well as increasing the effectiveness. Helical coil h... In global industrialization, efforts have been made to increase the rate of heat transfer in heat exchanger, minimizing the size of heat exchanger to reduce cost as well as increasing the effectiveness. Helical coil heat exchanger (HCHE) has been proven to be effective in improving heat transfer due to its large surface area. In this study, HCHE was designed to provide hot air needed for fluidized bed drying processes. The HCHE design model was fabricated and evaluated to study the efficiency of the hot air output for a laboratory fluidized bed dryer. The mathematical model for estimation of the final (output) temperature of air, Taf, passing through the HCHE was developed and validated experimentally. The drying of bitter kola particulates was carried out with a drying temperature of 50C 3C and a bed height-to-bed diameter ratio (H/D) of 1.5. The time taken to dry bitter kola particulates to 0.4% moisture content was 1 hour 45 minutes. Hence, HCHE is recommended for use in the production of hot for laboratory-scale fluidized bed dryers. 展开更多
关键词 Helical Coil heat exchanger Fluidized Bed Dryer heat Transfer Output air Temperature
下载PDF
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
3
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
4
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
A Study on the Performances of Solar Air Collectors Having a Hemispherical Dimple on the Absorber Plate
5
作者 Shuilian Li Fan Zeng Xinli Wei 《Fluid Dynamics & Materials Processing》 EI 2024年第5期939-955,共17页
In order to increase the efficiency of solar air collectors,a new variant with a protrusion is proposed in this study,and its performances are analyzed from two points of view,namely,in terms of optics and thermodynam... In order to increase the efficiency of solar air collectors,a new variant with a protrusion is proposed in this study,and its performances are analyzed from two points of view,namely,in terms of optics and thermodynamics aspects.By comparing and analyzing the light paths of the protrusion and the dimple,it can be concluded that when sunlight shines on the dimple,it is reflected and absorbed multiple times,whereas for the sunlight shining on the protrusion,there is no secondary reflection or absorption of light.When the lighting area and the properties of the surfaces are the same,the absorption rate of the dimple is 10.3 percentage points higher than that of the protrusion.In the range of Reynolds number from 3000 to 11000,numerical simulations about the effects of the relative height(e/Dh=0.033–0.1)and relative spacing(p/e=4.5–8.5)of protrusions on air heat transfer and flow resistance show that,in terms of comprehensive evaluation coefficient(PF),the best relative height is 0.085,when the relative spacing is 5.A correlation of Nu and f with Re,e/Dh and p/e is obtained by linear regression of the results,in order to provide a useful reference for the design and optimization of this kind of solar air collector. 展开更多
关键词 heat transfer hemispherical protrusion DIMPLE solar air collector CORRELATION
下载PDF
Operating Parameters of the District Heating Substation Cooperating With the Installation of Technological Air Conditioning With High Efficiency of Heat Recovery
6
作者 Żarski Kazimierz Kryża Mariusz 《Chinese Business Review》 2024年第1期1-12,共12页
The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange... The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated. 展开更多
关键词 ventilation of operating theatre air conditioning flow control in heating circuit
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
7
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2023年第8期61-85,共17页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned heat Pipe heat exchanger Thermal Efficiency Thermal Effectiveness air Conditioning Freon R404A
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
8
作者 Élcio Nogueira 《Journal of Modern Physics》 2023年第8期61-85,共6页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned heat Pipe heat exchanger Thermal Efficiency Thermal Effectiveness air Conditioning Freon R404A
下载PDF
Adaptive inverse control of air supply flow for proton exchange membrane fuel cell systems 被引量:2
9
作者 李春华 朱新坚 +2 位作者 隋升 胡万起 胡鸣若 《Journal of Shanghai University(English Edition)》 CAS 2009年第6期474-480,共7页
To prevent the oxygen starvation and improve the system output performance, an adaptive inverse control (AIC) strategy is developed to regulate the air supply flow of a proton exchange membrane fuel cell (PEMFC) s... To prevent the oxygen starvation and improve the system output performance, an adaptive inverse control (AIC) strategy is developed to regulate the air supply flow of a proton exchange membrane fuel cell (PEMFC) system in this paper. The PEMFC stack and the air supply system including a compressor and a supply manifold are modeled for the purpose of performance analysis and controller design. A recurrent fuzzy neural network (RFNN) is utilized to identify the inverse model of the controlled system and generates a suitable control input during the abrupt step change of external disturbances. Compared with the PI controller, numerical simulations are performed to validate the effectiveness and advantages of the proposed AIC strategy. 展开更多
关键词 proton exchange membrane fuel cell (PEMFC) air supply system COMPRESSOR adaptive inverse control (AIC) recurrent fuzzy neural network (RFNN)
下载PDF
Techno-economic feasibility assessment of a diesel exhaust heat recovery system to preheat mine intake air in remote cold climate regions 被引量:1
10
作者 Marco Antonio Rodrigues de Brito Durjoy Baidya Seyed Ali Ghoreishi-Madiseh 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2020年第4期517-523,共7页
Underground mines in Arctic and Subarctic regions require the preheating of mine intake air during winter.The cold fresh air of those remote areas can be as severe as40℃ and commonly needs to be heated to around+3℃... Underground mines in Arctic and Subarctic regions require the preheating of mine intake air during winter.The cold fresh air of those remote areas can be as severe as40℃ and commonly needs to be heated to around+3℃.This extensive amount of heating is usually provided by employing large-size air heaters,fueled by diesel,propane,natural gas,or heavy oil,leading to high energy costs and large carbon footprints.At the same time,the thermal energy content of a diesel generator sets(gen-sets)exhaust is known to be one-third of the total heating value of its combusted fuel.Exhaust heat recovery from diesel gen-sets is a growing technology that seeks to mitigate the energy costs by capturing and redirecting this commonly rejected exhaust heat to other applications such as space heating or pre-heating of the mine intake air.The present study investigated the possibility of employing a simple system based on off-theshelf heat exchanger technology,which can recover the waste heat from the exhaust of the power generation units(diesel gen-sets)in an off-grid,cold,remote mine in Canada for heating of the mine intake air.Data from a real mine was used for the analysis along with environmental data of three different location-scenarios with distinct climates.After developing a thermodynamic model,the heat savings were calculated,and an economic feasibility evaluation was performed.The proposed system was found highly viable with annual savings of up to C$6.7 million and capable enough to provide an average of around 75%of the heating demand for mine intake air,leading to a payback period of about eleven months or less for all scenarios.Deployment of seasonal thermal energy storage has also been recommended to mitigate the mismatch between supply and demand,mainly in summertime,possibly allowing the system to eliminate fuel costs for intake air heating. 展开更多
关键词 Exhaust heat recovery Mine energy management Mine heating Alternative energy Intake air heating
下载PDF
Modeling of Air Temperature for Heat Exchange due to Vertical Turbulence and Horizontal Air Flow
11
作者 ZHANG Lei,MENG Qing-lin(State Key Laboratory of Subtropical Building Science,South China University of Technology,Guangzhou,Guangdong 510640,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期45-50,共6页
In order to calculate the air temperature of the near surface layer in urban environment,the surface layer air was divided into several layers in the vertical direction,and some energy balance equations were developed... In order to calculate the air temperature of the near surface layer in urban environment,the surface layer air was divided into several layers in the vertical direction,and some energy balance equations were developed for each air layer,in which the heat exchange due to vertical turbulence and horizontal air flow was taken into account.Then,the vertical temperature distribution of the surface layer air was obtained through the coupled calculation using the energy balance equations of underlying surfaces and building walls.Moreover,the measured air temperatures in a small area(with a horizontal scale of less than 500 m)and a large area(with a horizontal scale of more than 1 000 m)in Guangzhou in summer were used to validate the proposed model.The calculated results agree well with the measured ones,with a maximum relative error of 4.18%.It is thus concluded that the proposed model is a high-accuracy method to theoretically analyze the urban heat island and the thermal environment. 展开更多
关键词 TURBULENT heat exchange urban thermal environment near surface layer air temperature calculation model
下载PDF
Achieving Cooler Soil as an Effective Heat Sink for Earth-to-Air Heat Exchanger (EAHE) Cooling Technology in Malaysia Tropical Climate
12
作者 Aliyah Nur Zafirah Sanusi Aidil Azlan Ahmad Zamri 《Natural Resources》 2014年第13期804-809,共6页
This research is intended to explore the capacity of Malaysia soil in becoming a more effective heat sink for the application of Earth-to-Air Heat Exchanger (EAHE) Cooling Technology in Malaysia. EAHE Cooling Technolo... This research is intended to explore the capacity of Malaysia soil in becoming a more effective heat sink for the application of Earth-to-Air Heat Exchanger (EAHE) Cooling Technology in Malaysia. EAHE Cooling Technology consists of buried pipes underground where the ambient air is channeled through from the pipe inlet and produces cooler air at its outlet. Within the buried pipes, heat exchange process occurs between the air and the soil that surrounding the pipe. This building cooling technology has been applied in many countries, mostly in temperate or hot and arid climate where the diurnal temperature is large. However, minimal resources were found on the study of EAHE application to buildings in Malaysia, hence there is room to develop. A parametric study on EAHE cooling application in Malaysia was done through field experiment and concluded that among many parameters affecting the technology performance, the soil temperature which surrounded the pipe was the most influential factor. The study recommended to further reduce the soil temperature to achieve a cooler outlet temperature. In response to that, this research conducted a parametric study of soil temperature under three different soil surface conditions: bare, shaded with timber pallettes and insulated with used tyres at 1.0 m and 1.5 m underground. The data was logged for a month and the result has shown significant reduction in the soil temperature underground below the shaded and insulated soil surface as compared to below bare soil surface condition. The insulated soil surface produced the best result where the soil temperature was reduced up to 26.9°C. The main contribution of this paper is to highlight that the soil surface treatment can be used to reduce solar heat gain within the soil underground and thus improving the performance of EAHE Cooling Technology particularly for the application in Malaysia tropical climate. 展开更多
关键词 Ground COOLING Green Technology Earth-to-air heat exchangeR Cooled SOIL
下载PDF
Soil Nature Effect Investigation on the Ground-to-Air Heat Exchanger for the Passive Cooling of Rooms
13
作者 Kokou N’wuitcha Yendouban Kolani +2 位作者 Yawovi Nougblega Magolmèèna Banna Belkacem Zeghmati 《Open Journal of Fluid Dynamics》 CAS 2022年第4期321-341,共21页
The building sector consumes much energy either for cooling or heating and is associated to greenhouse gas emissions. To meet energy and environmental challenges, the use of ground-to-air heat exchangers for preheatin... The building sector consumes much energy either for cooling or heating and is associated to greenhouse gas emissions. To meet energy and environmental challenges, the use of ground-to-air heat exchangers for preheating and cooling buildings has recently received considerable attention. They provide substantial energy savings and contribute to the improvement of thermal comfort in buildings. For these systems, the ground temperature plays the main role. The present work aims to investigate numerically the influence of the nature of soil on the thermal behavior of the ground-to-air heat exchanger used for building passive cooling. We have taken into account in this work the influence of the soil nature by considering three types of dry soil: clay soil, sandy-clay soil and sandy soil. The mixed convection equations governing the heat transfers in the earth-to-air heat exchanger have been presented and discretized using the finite difference method with an Alternate Direction Implicit (ADI) scheme. The resulting algebraic equations are then solved using the algorithm of Thomas combined with an iterative Gauss-Seidel procedure. The results show that the flow is dominated by forced convection. The examination of the sensitivity of the model to the type of soil shows that the distributions of contours of streamlines, isotherms, isovalues of moisture are less affected by the variations of the nature of soil through the variation of the diffusivity of the soil. However, it is observed that the temperature values obtained for the clay soil are higher while the sandy soil shows lower temperature values. The values of the ground-to-air heat exchanger efficiency are only slightly influenced by the nature of the soil. Nevertheless, we note a slightly better efficiency for the sandy soil than for the sandy-clayey silt and clayey soils. This result shows that a sandy soil would be more suitable for geothermal system installations. 展开更多
关键词 Soil Temperature Laminar Regime Ground-to-air heat exchanger heat Transfer Geothermal system
下载PDF
The relation between ambulance transports due to heat stroke and air temperature using daily data in Okayama prefecture, Japan 被引量:1
14
作者 Nobuyuki Miyatake Noriko Sakano Shoko Murakami 《Open Journal of Preventive Medicine》 2012年第1期112-115,共4页
The aim of this study was to investigate the link between ambulance transports due to heat stroke and air temperature by using daily data of ambulance transports in Okayama prefecture, Japan. Daily observations for am... The aim of this study was to investigate the link between ambulance transports due to heat stroke and air temperature by using daily data of ambulance transports in Okayama prefecture, Japan. Daily observations for ambulance transports due to heat stroke from July to September in 2010 in Okayama prefecture, Japan were obtained from Fire and Disaster Management Agency in Japan. Data of meteorological parameters in Okayama prefecture, Japan were also obtained from Japan Meteorological Agency. Effect of meteorological parameters on ambulance transports due to heat stroke was analyzed. A total of 1133 ambulance transports due to heat stroke were observed in from July to September of 2010 in Okayama prefecture, Japan. Ambulance transports due to heat stroke was significantly correlated with air temperature. In addition, number of subjects with ambulance transports due to heat stroke over 34°C in the highest air temperature was 21.2 ± 9.8 per day. Higher air temperature was closely associated with higher ambulance transports due to heat stroke by using daily data in Okayama, prefecture, Japan. 展开更多
关键词 heat Stroke AMBULANCE TRANSPORTS Okayama air Temperature DAILY DATA
下载PDF
Influence of Different Vortex Generators on Heat Transfer in Direct Air-Cooled Condensers 被引量:17
15
作者 ZHOU Guobing YANG Laishun 《中国电机工程学报》 EI CSCD 北大核心 2012年第5期I0001-I0020,共20页
通过数值模拟研究了矩形小翼、三角小翼、梯形小翼、柱面梯形翼、柱面三角翼和柱面矩形翼等6种涡流发生器分别安装于直接空冷凝汽器单排蛇形翅片扁管中的压降和换热性能。Re数在600~1800范围内,涡流发生器采用相同高宽比、尾高、攻角以... 通过数值模拟研究了矩形小翼、三角小翼、梯形小翼、柱面梯形翼、柱面三角翼和柱面矩形翼等6种涡流发生器分别安装于直接空冷凝汽器单排蛇形翅片扁管中的压降和换热性能。Re数在600~1800范围内,涡流发生器采用相同高宽比、尾高、攻角以及安装位置。结果表明:矩形小翼的换热及压降增大最多,Re=1729时,相比平直翅片分别增加了14.27%和18.32%。Re=1 729时,柱面梯形翼的压力损失比矩形小翼少4.7%,换热低1.5%。当以(j/j0)/(f/f0)1/3作为综合换热性能评价标准时,柱面梯形翼的综合换热性能最好。另外,考察了柱面梯形翼倾角的影响(0°、6°、12°、20°、24°和26°),相同工况下,倾角为12°的柱面梯形翼换热最好(较平直翅片增强4.29%~14.1%)、压降最小(增大7.5%~12.8%)且综合换热性能最好。柱面梯形翼因其迎流面积与斜边长度的匹配以及流线型柱面,具有良好的强化传热效果以及较小的压降。 展开更多
关键词 直接空冷凝汽器 涡发生器 传热 涡流发生器 风冷冷凝器 空气冷却 化学工业 热交换器
下载PDF
The higher air temperature was closely associated with higher ambulance transports due to heat stroke in elderly Japanese 被引量:1
16
作者 Nobuyuki Miyatake Noriko Sakano Shoko Murakami 《Open Journal of Epidemiology》 2011年第1期1-4,共4页
To investigate the link between higher air temperature and ambulance transports due to heat stroke, especially in elderly subjects, using daily data in Sai-tama prefecture in August, 2010, Japan. We obtained daily dat... To investigate the link between higher air temperature and ambulance transports due to heat stroke, especially in elderly subjects, using daily data in Sai-tama prefecture in August, 2010, Japan. We obtained daily data of air temperature in Saitama prefecture in August, 2010, Japan from Japan Meteorological Agency. Number of ambulance transports due to heat stroke was also used by Saitama prefecture official website. The effect of high air temperature on am-bulance transports due to heat stroke was evaluated. A total of 1688 ambulance transports due to heat stroke was observed in Saitama prefecture in August, 2010, Japan. Seven hundred and twenty one subjects (42.7%) were over the age of 65. Mean air temperature, the highest air temperature and day light hours were significantly associated with ambulance transports due to heat stroke in total subjects (mean air temperature: r = 0.749, p < 0.0001) and the over the age of 7. In addition, by separate analysis as classified by age groups, the correlation coefficient between ambulance transports due to heat stroke and mean air temperature was the highest in subjects with over 65. However, the lowest air temperature was not cor-related with ambulance transports due to heat stroke. Higher air temperature was closely associated with higher ambulance transports due to heat stroke using daily data in Saitama prefecture in August, 2010, Ja-pan, especially in elderly subjects. 展开更多
关键词 air Temperature AMBULANCE TRANSPORTS heat Stroke Saitama Prefecture Japan
下载PDF
Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump 被引量:7
17
作者 董建锴 姜益强 +1 位作者 姚杨 张雪丹 《Journal of Central South University》 SCIE EI CAS 2011年第6期2163-2169,共7页
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho... To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting. 展开更多
关键词 逆循环除霜 除霜方法 空气源热泵 热能储存 经营业绩 对比实验 持续时间 能源消耗
下载PDF
Air-sea heat flux exchange over the South China Sea under different weather conditions before and after southwest monsoon onset in 2000 被引量:8
18
作者 Junyue Yan, Huadong Yao, Jianglong Li, Zhiyi Tang, Guorong Jiang, Wenyu Sha, Xunqiang Li, Yiguo Xiao National Climate Center, Beijing 100081, China. E-mail: yanjy@cma.gov.cnPLA University of Science Technology, Nanjing 211101, China 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2003年第3期369-383,共15页
With the data observed from the Second SCS Air-Sea Flux Experiment on the Xisha air-sea flux research tower, the radiation budget, latent, sensible heat fluxes and net oceanic heat budgets were caculated before and af... With the data observed from the Second SCS Air-Sea Flux Experiment on the Xisha air-sea flux research tower, the radiation budget, latent, sensible heat fluxes and net oceanic heat budgets were caculated before and after summer monsoon onset. It is discovered that, after summer monsoon onset, there are considerable changes in air-sea fluxes, especially in latent heat fluxes and net oceanic heat budget. Furthermore, the analyzed results of five synoptic stages are compared. And the characteristics of the flux transfer during different stages around onset of South China Sea monsoon are discussed. The flux change shows that there is an oceanic heat accumulating process during the pre-onset and the break period, as same as oceanic heat losing process during the onset period. Moreover, latent fluxes, the water vapor moving to the continent, even the rainfall appearance in Chinese Mainland also can be influenced by southwester. Comparing Xisha fluxes with those obtained from the Indian Ocean and the western Pacific Ocean, their differences may be observed. It is the reason why SSTs can keep stable over the South China Sea while they decrease quickly over the Arabian Sea and the Bay of Bengal after monsoon onset. 展开更多
关键词 South China Sea air-sea heat fluxes South China Sea monsoon
下载PDF
Energy Efficient Air Conditioning System Using Geothermal Cooling-Solar Heating in Gujarat, India 被引量:1
19
作者 Sneha Shahare T. Harinarayana 《Journal of Power and Energy Engineering》 2016年第1期57-71,共15页
It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, t... It is well known that one unit of electrical energy saved is equal to more than two units produced. One way of economizing the power is utilization of energy efficient systems at all locations. In the present study, the air conditioning system is analysed and an innovative way is suggested. We use natural low temperature of shallow sub surface (1 - 3 m) of the earth—geothermal cooling system. It is known that majority of the households and the apartment complexes in India have two tanks for water storage. One is the underground water sump and the other is the overhead water tank. In our study, we use these two water storage systems for space cooling during summer and also for heating during winter. The main aim of our paper is air-conditioning of the space in an economic way to save electricity. It is based on a simple idea of transferring the low temperature from underground water sump to the room in the house using water as a mode of transport. Since India is a tropical country located at low latitude, most of the year, the air temperature is high and demands space cooling. However, for a couple of months during severe winter months (Dec.-Jan.) at Ahmedabad, heating of the space is required. For heating the space, we suggest to use the well-known solar water heater. Effective use of heat exchanger is shown through computation, modelling schemes and lab experiment. We recommend geothermal cooling for 10 months in a year and solar hot water system during 2 months of winter. It is observed that the ambient air temperature of 35°C - 40°C in the room can be brought down to 26°C without much consumption of electricity. In a similar manner, the room temperature at night (13°C) during winter in Ahmedabad can be increased to 27°C through circulation of water from solar water heater in the heat exchanger. 展开更多
关键词 Energy Efficiency Geothermal Cooling air Conditioning CFD Thermal Comfort Earth Water heat exchanger
下载PDF
Entropy Assessment on Environmental Influence of Condense Heat in Recovery System in Air-Conditioning Refrigerating Machine 被引量:2
20
作者 TANG Wen-wu1,2,WANG Han-qing1,2(1.School of Energy Science and Engineering,Central South University,Changsha,Hunan 410083,China 2.School of Civil Engineering,Hunan University of Technology,Zhuzhou,Hunan 412008,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期96-101,共6页
This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ... This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%). 展开更多
关键词 air-CONDITIONING refrigerating MACHINE condense heat ENTROPY evaluation LS-SVM
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部