The location of exhaust air vents of an evaporative cooling system can have significant effects on providing thermal comfort and controlling humidity, temperature and air distribution in buildings. In the current stud...The location of exhaust air vents of an evaporative cooling system can have significant effects on providing thermal comfort and controlling humidity, temperature and air distribution in buildings. In the current study, four different strategies have been evaluated for exhaust air vent locations to provide the optimum thermal comfort inside a typical residential house. This study provides a numerical solution for temperature and relative humidity profiles in the residential house and within the living space in each room typically at a height of 1.8 m or less. By evaluating different exhaust air vent locations in a room, the best strategy(ies) to provide more appropriate thermal comfort condition and obtained and as a conclusion, the exhaust vents should be located on furthest wall away from the entrance of the room and in the middle. The results provided in the current study can eventually be applied in the design of evaporative cooler exhaust vent systems in residential buildings and lead to improve the performance of these systems.展开更多
A novel hood structure has been designed for the dust control system in the foundry in order to improve the working environment. A composite strategy has been applied for comparative analysis of the optimal venting vo...A novel hood structure has been designed for the dust control system in the foundry in order to improve the working environment. A composite strategy has been applied for comparative analysis of the optimal venting volume and the airflow distribution between the conventional hood and the novel one in this study. A Computational Fluid Dynamic (CFD) method is used to simulate the airflow fields and dust-polluted air moving paths. The CFD results show that a two-outlet hood, with one outlet located on the left of the hood, is better for improving dust-polluted air than the hood with one outlet only. It can be concluded that the number of the outlets as well as their location on the hood has a significant influence on the air flow pattern in the hood. The optimal venting volume is also a major consideration that is discussed in the study. The venting volume should be designed by considering both the effective level of air flow velocity around the dust source and the energy saving. The optimal airflow distribution may reduce the turbulence in the hood system.展开更多
A spillway aerator should guarantee favorable flow conditions in the coupled water-air system even if the aerator is unconventionally wide. Eight air-vent configurations are devised and incorporated into a 35-m wide c...A spillway aerator should guarantee favorable flow conditions in the coupled water-air system even if the aerator is unconventionally wide. Eight air-vent configurations are devised and incorporated into a 35-m wide chute aerator for a generalized study. Computational fluid dynamics(CFD) simulations are performed to explore their effects on water-jet and air-cavity features. The Re-normalisation group(RNG) k-ε turbulence model and the two-fluid model are combined to predict the two-phase flow field. The results demonstrate appreciable influences of the vent layouts on the water-air flow. The air vents stir the air motion and re-distribute the cavity air pressure. Once the vent layout is modified, reciprocal adjustments exist between the jet behavior and air-pressure field in the cavity, thus leading to considerable differences in air-flow rate, jet-trajectory length, vent air-flow distribution across the chute, etc. The large width plays a discernable role in affecting the aerated flow. Telling differences exist between the near-wall region and the central part of the chute. To improve the duct pressure propagation, a gradual augment of the vent area should be assigned towards the chute center. Relative to single-slot vents across the flow, the layouts with segregated vents gain by comparison. A designer should see to it that a vented aerator operates satisfactorily for a given range of flow discharges.展开更多
Experimental investigations were conducted on the process of combustion and explosion vent in a 200 mm (diame- ter)×400 mm (length) vertical cylindrical vessel. When CH4-air mixture gases were used and the vent d...Experimental investigations were conducted on the process of combustion and explosion vent in a 200 mm (diame- ter)×400 mm (length) vertical cylindrical vessel. When CH4-air mixture gases were used and the vent diameter was 55 mm, conditions of Φ (equivalent ratio)=0.8, Φ=1.0 and Φ=1.3 and two ignition positions (at the cylinder center and bottom) were selected. The venting processes and the correlated factors are discussed in this paper.展开更多
文摘The location of exhaust air vents of an evaporative cooling system can have significant effects on providing thermal comfort and controlling humidity, temperature and air distribution in buildings. In the current study, four different strategies have been evaluated for exhaust air vent locations to provide the optimum thermal comfort inside a typical residential house. This study provides a numerical solution for temperature and relative humidity profiles in the residential house and within the living space in each room typically at a height of 1.8 m or less. By evaluating different exhaust air vent locations in a room, the best strategy(ies) to provide more appropriate thermal comfort condition and obtained and as a conclusion, the exhaust vents should be located on furthest wall away from the entrance of the room and in the middle. The results provided in the current study can eventually be applied in the design of evaporative cooler exhaust vent systems in residential buildings and lead to improve the performance of these systems.
基金supported by the Shanghai Leading Academic Discipline Project(B604)the Henan Science and Technology Breakthrough Major Project(102102210440)+1 种基金the High School Funding Scheme for Key Young Teachersthe Education Department of Henan Province,2010
文摘A novel hood structure has been designed for the dust control system in the foundry in order to improve the working environment. A composite strategy has been applied for comparative analysis of the optimal venting volume and the airflow distribution between the conventional hood and the novel one in this study. A Computational Fluid Dynamic (CFD) method is used to simulate the airflow fields and dust-polluted air moving paths. The CFD results show that a two-outlet hood, with one outlet located on the left of the hood, is better for improving dust-polluted air than the hood with one outlet only. It can be concluded that the number of the outlets as well as their location on the hood has a significant influence on the air flow pattern in the hood. The optimal venting volume is also a major consideration that is discussed in the study. The venting volume should be designed by considering both the effective level of air flow velocity around the dust source and the energy saving. The optimal airflow distribution may reduce the turbulence in the hood system.
基金part of research project "Hydraulic design of spillway aerators"funded in part by Swedish Hydropower Centre(SVC)+2 种基金Vattenfall R&DFortum GenerationUniper/Sweco have indirectly facilitated the study
文摘A spillway aerator should guarantee favorable flow conditions in the coupled water-air system even if the aerator is unconventionally wide. Eight air-vent configurations are devised and incorporated into a 35-m wide chute aerator for a generalized study. Computational fluid dynamics(CFD) simulations are performed to explore their effects on water-jet and air-cavity features. The Re-normalisation group(RNG) k-ε turbulence model and the two-fluid model are combined to predict the two-phase flow field. The results demonstrate appreciable influences of the vent layouts on the water-air flow. The air vents stir the air motion and re-distribute the cavity air pressure. Once the vent layout is modified, reciprocal adjustments exist between the jet behavior and air-pressure field in the cavity, thus leading to considerable differences in air-flow rate, jet-trajectory length, vent air-flow distribution across the chute, etc. The large width plays a discernable role in affecting the aerated flow. Telling differences exist between the near-wall region and the central part of the chute. To improve the duct pressure propagation, a gradual augment of the vent area should be assigned towards the chute center. Relative to single-slot vents across the flow, the layouts with segregated vents gain by comparison. A designer should see to it that a vented aerator operates satisfactorily for a given range of flow discharges.
基金Project (No. 19832030) supported by the National Natural Science Foundation of China
文摘Experimental investigations were conducted on the process of combustion and explosion vent in a 200 mm (diame- ter)×400 mm (length) vertical cylindrical vessel. When CH4-air mixture gases were used and the vent diameter was 55 mm, conditions of Φ (equivalent ratio)=0.8, Φ=1.0 and Φ=1.3 and two ignition positions (at the cylinder center and bottom) were selected. The venting processes and the correlated factors are discussed in this paper.