期刊文献+
共找到4,358篇文章
< 1 2 218 >
每页显示 20 50 100
Remote Control of Unitary Air Conditioner Based on Manufacturing Message Specification
1
作者 黄伟红 陈圣权 吴介一 《Journal of Southeast University(English Edition)》 EI CAS 1999年第2期43-48,共6页
Traditional air conditioner used to be in local control mode. However, with the development of modern information technology, the control of air conditioner will have to support many more functions. As a first step ... Traditional air conditioner used to be in local control mode. However, with the development of modern information technology, the control of air conditioner will have to support many more functions. As a first step in such a development, we have implemented a remote monitoring system of unitary air conditioners, using the manufacturing message specification (MMS). MMS is an OSI application protocol designed for the remote control and monitoring of real devices. The functions supported are those that an operator would do normally at the console of the unitary air conditioner. Due to the accomplishment of UMCS (Unitary air conditioner MMS Control System), there will be a leap of the application of MMS and the control technology of unitary air conditioner. 展开更多
关键词 remote control manufacturing message specification unitary air conditioner
下载PDF
DISPLACEMENT CONTROL AND KINETIC ANALYSIS OF A NOVEL VARIABLE DISPLACEMENT COMPRESSOR FOR AUTOMOTIVE AIR CONDITIONER 被引量:7
2
作者 Yuan Xiaomei,Chen Zhijiu (Institute of Refrigeration and Cryogenics Engineering, Shanghai Jiaotong University) 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2001年第4期325-329,共5页
A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of... A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of pneumatic valve the displacement is controlled by electronic control valve. In order to know the control mechanism well and get a good control effect, a mathematical model for the variable displacement mechanism is developed according to the geometrical and kinematical information of the compressor. Using the model, the effect of relevant parameters on variable displace control is estimated. It is helpful to make the optimum decision in the flow control of AAC. As the novel displacement control device, the structure and control rule of electronic control valve is introduced. It can get better effect than the conventional pneumatic valves. And by using this new electronic control device, the optimum systemic control of AAC is available. 展开更多
关键词 Displacement control Kinetic analysis Automotive air conditioner (AAC) Variable displacement compressor(VDC)
下载PDF
A Study on the Reduction of the Aerodynamic Drag and Noise Generated By the Roof Air Conditioner of High-Speed Trains 被引量:5
3
作者 Jiali Liu Mengge Yu +1 位作者 Dawei Chen Zhigang Yang 《Fluid Dynamics & Materials Processing》 EI 2020年第1期21-30,共10页
In order to investigate how the aerodynamic drag and noise produced by the roof air conditioner of a high-speed train can be reduced,the related unsteady flow in the near-field was computed using the method of large e... In order to investigate how the aerodynamic drag and noise produced by the roof air conditioner of a high-speed train can be reduced,the related unsteady flow in the near-field was computed using the method of large eddy simulation.In this way,the aerodynamic source for noise generation has initially been determined.Then,the far-field aerodynamic noise has been computed in the framework of the Lighthill’s acoustics analogy theory.The propulsion height and flow-guide angle of the roof air conditioner were set as the design variables.According to the computational results,a lower propulsion height or flow-guide angle is beneficial in terms of aerodynamic drag and noise mitigation.However,compared to the design scheme with propulsion height of 0mm,the aerodynamic drag coefficient of the configuration with propulsion height of 190mm and flow-guide angle of 30°is slightly larger,while the aerodynamic noise is obviously reduced.Thus,from the viewpoint of the aerodynamic drag and noise,the design scheme with propulsion height of 190 mm and flow-guide angle of 30°is the optimal configuration in the range of conditions examined in the present work. 展开更多
关键词 Aerodynamic drag aerodynamic noise roof air conditioner large eddy simulation acoustics analogy theory
下载PDF
Air-condition process for scalable fabrication of CdS/ZnS 1D/2D heterojunctions toward efficient and stable photocatalytic hydrogen production
4
作者 Dongdong Zhang Jie Teng +7 位作者 Hongli Yang Zhi Fang Kai Song Lin Wang Huilin Hou Xianlu Lu Chris RBowen Weiyou Yang 《Carbon Energy》 SCIE CSCD 2023年第7期1-14,共14页
We report the scalable fabrication of CdS/ZnS 1D/2D heterojunctions under ambient air conditions(i.e.,room temperature and atmospheric pressure)in which ZnS nanoparticles are anchored on the surface of CdS nanosheets.... We report the scalable fabrication of CdS/ZnS 1D/2D heterojunctions under ambient air conditions(i.e.,room temperature and atmospheric pressure)in which ZnS nanoparticles are anchored on the surface of CdS nanosheets.The as-formed heterojunctions exhibit a significantly enhanced photocatalytic H_(2) evolution rate of 14.02 mmol h^(-1) g^(-1) when irradiated with visible light,which is~10 and 85 times higher than those of pristine CdS nanosheets and CdS nanoparticles,respectively,and superior to most of the CdS-based photocatalysts reported to date.Furthermore,they provide robust photocatalytic performance with demonstratable stability over 58 h,indicating their potential for practical applications.The formation of 1D/2D heterojunctions not only provides improved exposed active sites that respond to illumination but also provides a rapid pathway to generate photogenerated carriers for efficient separation and transfer through the matrix of single-crystalline CdS nanosheets.In addition,first-principles simulations demonstrate that the existence of rich Zn vacancies increases the energy level of the ZnS valence band maximum to construct type-II and Z-scheme mixed heterojunctions,which plays a critical role in suppressing the recombination of carriers with limited photocorrosion of CdS to enhance photocatalytic behavior. 展开更多
关键词 air condition CDS HETEROJUNCTIONS photocatalytic hydrogen production ZNS
下载PDF
A PROSPECTIVE HYDROGEN STORAGE ALLOY PAIR FOR BUS AIR CONDITIONERS 被引量:1
5
作者 Wang Xinhua and Chen Changpin Department of Materials Science and Engineering,Zhejiang University, Hangzhou 310027, P. R. China 《中国有色金属学会会刊:英文版》 CSCD 1998年第1期57-60,共4页
APROSPECTIVEHYDROGENSTORAGEALLOYPAIRFORBUSAIRCONDITIONERS①WangXinhuaandChenChangpinDepartmentofMaterialsScie... APROSPECTIVEHYDROGENSTORAGEALLOYPAIRFORBUSAIRCONDITIONERS①WangXinhuaandChenChangpinDepartmentofMaterialsScienceandEnginering,... 展开更多
关键词 hydride HYDROGEN STORAGE ALLOY BUS heat pump air conditioner
下载PDF
Girth welding system for vortex type refrigeration compressor of air conditioner 被引量:1
6
作者 刘小文 马彩霞 +1 位作者 杨思乾 胡记生 《China Welding》 EI CAS 2006年第1期57-60,共4页
According to the requirements of welding process for vortex type compressor of air conditioner manufactured in product line, a special girth welding machine with PLC as control core was developed, which had both uprig... According to the requirements of welding process for vortex type compressor of air conditioner manufactured in product line, a special girth welding machine with PLC as control core was developed, which had both upright and 45 ° incline service positions. And some key technologies were researched, such as structural design of machine body, reliable conduction of rotary weldments and quality control of welding process and so on. The experimental results showed that this machine could satisfy the requirements of welding quality and girth welding technology, results also proved the machine was a high-effwiency and low-cost automatic welding device. 展开更多
关键词 air conditioner compressor girth welding welding machine
下载PDF
A Comparative Study on the Performance and Environmental Characteristics of Alternatives to R22 in Residential Air Conditioners for Tunisian Market 被引量:1
7
作者 M.C. Zaghdoudi S. Maalej +1 位作者 Y. Saad M. Bouchaala 《Journal of Environmental Science and Engineering》 2010年第12期37-56,共20页
This paper presents the simulation results of a 9000 BTU/h air conditioner with some selected fluids that have been assessed for their suitability as alternatives to R22 for air conditioners. Only those refrigerants w... This paper presents the simulation results of a 9000 BTU/h air conditioner with some selected fluids that have been assessed for their suitability as alternatives to R22 for air conditioners. Only those refrigerants with zero Ozone Depletion Potential (ODP) are considered. The performances of 11 refrigerants were comparatively studied using the simulation software NIST Cycle_D. R134a, R290, R600, R404A, R407A, R407B, R407C, 407D, R410A, R410B, and R417A are considered in this study. The thermal performances, which are obtained with R 134a and R290, are very close to those of R22. The power consumptions of the unit operating with R404A, R407C, and R410A are higher in the range 22-31% with respect of R22. For the units operating with 407A, R407B, R407D, R407E, and R410B, the electric consumptions are higher in the range 10-23%. For R600, the power consumptions are in the range 6-8%. For all the fluids, the COP is lower by 7-24% than R22, except for R600 for which the COP is higher by 7-9%, and R134a and R290 which exhibit the same COP as R22. When considering the thermal and environmental parameters, R290 is identified as the best candidate for R22, provided the safety aspects of using R290 are addressed. 展开更多
关键词 air conditioner REFRIGERANT REPLACEMENT simulation PERFORMANCE COP
下载PDF
Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner 被引量:3
8
作者 WU Chengjun LIU Jiang PAN Jie 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第4期836-845,共10页
DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structu... DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m3·h~(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice. 展开更多
关键词 DC-inverter split air-conditioner outdoor unit surrounding structure computational fluid dynamics(CFD) computational aerodynamic acoustics(CAA) simulation improved design
下载PDF
Optimal Scheduling of Air Conditioners for Energy Efficiency
9
作者 K.Venkatesan Uppu Ramachandraiah 《Journal of Electronic Science and Technology》 CAS CSCD 2018年第2期110-122,共13页
Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy... Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy efficiency. The main contribution of this work is modeling the telecommunication building for the fabric cooling load to schedule the operation of air conditioners. The time series data of the fabric cooling load of the building envelope is taken by simulation by using Energy Plus, Building Control Virtual Test Bed (BCVTB), and Matlab. This pre-computed data and other internal thermal loads are used for scheduling in air conditioners. Energy savings obtained for the whole year are about 4% to 6% by simulation and the field study, respectively. 展开更多
关键词 Building fabric cooling load energy balanced air conditioning energy efficiency scheduling of air conditioners
下载PDF
Quality Testing of Air Conditioner Condensate and Its Potential in Water Conservation
10
作者 Apurva Sabnis Madhuvanti Kale +1 位作者 Manik Dhanorkar Sharad P. Kale 《Journal of Water Resource and Protection》 2020年第2期93-101,共9页
A major part of world is facing water shortages today. While the world’s population has grown to more than 7.75 billion, the quantity of sweet water has remained the same. The ever increasing use of water by such a l... A major part of world is facing water shortages today. While the world’s population has grown to more than 7.75 billion, the quantity of sweet water has remained the same. The ever increasing use of water by such a large population has resulted in pollution of many water sources. The developing world where a large fraction of total world population is located faces water scarcity in a more severe manner than the developed world. The developed world has managed to control human population and preserve natural water resources more effectively. As a result of this and also due to stabilized population, they face lesser problems for water availability. Indian population stands at 1.386 billion as nowadays. The erratic monsoon rains over last few years have resulted in floods and subsequent water shortages in summer months in major part of the country. A similar situation is faced by many Asian and African countries. The means of recycling and using every possible source of water are always welcome in these countries. Since many of these countries lie in tropical or semitropical zone, the average relative humidity is more than 50% for most of the year. Changing life styles in these countries and spread of information technology based sectors have resulted in a growth spurt in air conditioning facilities. An air conditioner draws heat from surrounding air and cools the premises to desired temperature. During this process, a large amount of moisture in the atmosphere gets condensed and is drained out. There are no efforts made to recover this water in India and neighbouring countries. We have undertaken studies to check the quality of this water and see the feasibility of its use in a decentralized but effective manner. The results show that this water condensate from air conditioners is highly pure, substantial and available almost round the year. This can help in recovering millions of litres of good quality water daily. This water would find uses in industries, laboratories, households and farming. It would also create good business opportunities. 展开更多
关键词 WATER Conservation Resource Sustainability air conditioner CONDENSATE Relative Humidity Distilled WATER Demineralized WATER Total Dissolved SOLIDS (TDS) HARD WATER
下载PDF
Water, land, and energy use efficiencies and financial evaluation of air conditioner cooled greenhouses based on field experiments
11
作者 Ibtihal AL-MANTHRIA Abdulrahim M AL-ISMAILIA +2 位作者 Hemesiri KOTAGAMAB Mumtaz KHANC L H Janitha JEEWANTHAD 《Journal of Arid Land》 SCIE CSCD 2021年第4期375-387,共13页
High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial asp... High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial aspects of the AC-cooled greenhouse as compared to the evaporative cooled(EV-cooled)greenhouse in winter and summer seasons.Two quonset single-span prototype greenhouses were built in the Agriculture Experiment Station of Sultan Qaboos University,Oman,with dimensions of 6.0 m long and 3.0 m wide.The AC-cooled greenhouse was covered by a rockwool insulated polyethylene plastic sheet and light emitting diodes(LED)lights were used as a source of light,while the EV-cooled greenhouse was covered by a transparent polyethylene sheet and sunlight was used as light source.Three cultivars of high-value lettuce were grown for experimentation.To evaluate the technical efficiency of greenhouse performance,we conducted measures on land use efficiency(LUE),water use efficiency(WUE),gross water use efficiency(GWUE)and energy use efficiency(EUE).Financial analysis was conducted to compare the profitability of both greenhouses.The results showed that the LUE in winter were 10.10 and 14.50 kg/m^(2) for the AC-and EV-cooled greenhouses,respectively.However,the values reduced near to 6.80 kg/m^(2) in both greenhouses in summer.The WUE of the AC-cooled greenhouse was higher than that of the EV-cooled greenhouse by 3.8%in winter and 26.8%in summer.The GWUE was used to measure the total yield to the total greenhouse water consumption including irrigation and cooling water;it was higher in the AC-cooled greenhouse than in the EV-cooled greenhouse in both summer and winter seasons by almost 98.0%–99.4%.The EUE in the EV-cooled greenhouse was higher in both seasons.Financial analysis showed that in winter,gross return,net return and benefit-to-cost ratio were better in the EVcooled greenhouse,while in summer,those were higher in the AC-cooled greenhouse.The values of internal rate of return in the AC-and EV-cooled greenhouses were 63.4%and 129.3%,respectively.In both greenhouses,lettuce investment was highly sensitive to changes in price,yield and energy cost.The financial performance of the AC-cooled greenhouse in summer was better than that of the EV-cooled greenhouse and the pattern was opposite in winter.Finally,more studies on the optimum LED light intensity for any particular crop have to be conducted over different growing seasons in order to enhance the yield quantity and quality of crop. 展开更多
关键词 land use efficiency energy use efficiency water use efficiency gross water use efficiency financial evaluation air conditioner cooled greenhouse evaporative cooled greenhouse
下载PDF
Evaluation of Energy-Efficiency Standards for Room Air Conditioners in the US
12
作者 Alex Lekov Victor Franco Steve Meyers 《Open Journal of Energy Efficiency》 2012年第2期9-20,共12页
This article describes an analysis of the energy and economic impacts of possible energy efficiency standards for room air conditioners on both U.S. consumers and the nation as a whole. We used two metrics to determin... This article describes an analysis of the energy and economic impacts of possible energy efficiency standards for room air conditioners on both U.S. consumers and the nation as a whole. We used two metrics to determine the effect of standards on a representative sample of U.S. consumers: life-cycle cost change and payback period. For the national impact analysis, we evaluated national energy savings attributable to each potential standard, the monetary value of the energy savings to consumers of room air conditioners, the increased total installed costs because of standards, and the net present value of the difference between the value of energy savings and increased total installed costs. Our analysis indicates that standards for room air conditioners at efficiency level 3, which is 17% more efficient than today’s typical unit in the case of room air conditioners less than 6000 Btu/h with louvers and 12% more efficient in the case of room air conditioners 8000 - 13,999 Btu/h with louvers, would save close to one quad of energy over 30 years and have a net present value of consumer benefit of between ?$0.14 billion and $1.82 billion, depending on the discount rate. In addition, such standards would reduce carbon dioxide emissions and NOx emissions. 展开更多
关键词 ENERGY Efficiency STANDARDS Room air conditioners Consumer Benefit ENERGY SAVINGS LIFE-CYCLE Cost Payback Period Emissions REDUCTIONS
下载PDF
Guangdong Rowa Air Conditioner Co, Ltd.
13
《China's Foreign Trade》 2002年第6期31-31,共1页
THE COMPANYGuangdong Rowa Air Conditioner Company Limited, a subsidiary of Great Wall Cybertech Limited, is a leading air conditioner manufacturer in the People’s Republic of China. It was formerly the Guangdong Sann... THE COMPANYGuangdong Rowa Air Conditioner Company Limited, a subsidiary of Great Wall Cybertech Limited, is a leading air conditioner manufacturer in the People’s Republic of China. It was formerly the Guangdong Sanning Air-Conditioner Co., Ltd. 展开更多
关键词 OT OI Guangdong Rowa air conditioner Co LTD
下载PDF
Effect of air-conditioner exposure on semen quality
14
作者 Min-LiLu Jun-QingWu +2 位作者 Qiu-YingYang Wei-JinZhou Er-ShengGao 《Asian Journal of Andrology》 SCIE CAS CSCD 2004年第4期354-354,共1页
Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for prem... Aim: To investigate the effect of air-conditioner exposure on semen quality. Methods: The data came from the healthy male volunteers, aged 22 to 30 years, who went to centers for maternity and children health for premarital physical examination in Shanghai, Henan, Zhejiang and Hebei from December 1998 to February 2000. The sampling size is 304. Results: Among the subjects, 90 (29.6 %) had air-conditioner at home and the rest did not. X2-test and multiple logistic regression analyses showed that, the difference between the exposure and control groups was statistically significant in semen volume, sperm density and proportion of sperm with normal morphology. The three indexes were lower in the exposure group. Conclusion: Air-conditioner exposure possibly influences the semen quality. 展开更多
关键词 semen quality air-conditioner influencing factors
下载PDF
Window Air Conditioners Transition and Restriction in Saudi Arabia
15
作者 Essam Al Ammar Abdulhakim Bin Dayil 《Journal of Power and Energy Engineering》 2022年第5期1-21,共21页
This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spr... This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us. 展开更多
关键词 air conditioners (AC) Terawatt-Hour (TWh) Saudi Standards Metrology and Quality Organization (SASO) Energy-Efficiency Ratio (EER) High Efficiency air conditioning (HEAC) Carbon Dioxide (CO2) Heating Ventilation and air conditioning (HVAC) Saudi Building Code (SBC) Saudi Energy Efficiency Center (SEEC)
下载PDF
Jirong Air Conditioners
16
《China's Foreign Trade》 1997年第11期37-37,共1页
Various kinds of cabinet air conditioners,roof top air conditioners, cool-water set of air conditioners, and air treatment apparatuses,produced by Guangdong Jirong Air Conditioner Equipment Corporation, using world na... Various kinds of cabinet air conditioners,roof top air conditioners, cool-water set of air conditioners, and air treatment apparatuses,produced by Guangdong Jirong Air Conditioner Equipment Corporation, using world namebrand compressors, blower fans, computers,and control devices and other materials imported from abroad, are widely used in industrial and civil projects. The quality of the products is reliable, with low noise, easy operation, and high precision for control. Their main quotas for specifications are up to the international advanced standards. The output of Jirong cabinet and roof-top air conditioners is the leader in the country. The variety of cabinet conditioners includes water-cool and air-coon ones 展开更多
关键词 Jirong air conditioners
下载PDF
The Energy Efficiency Label to Be Attached on the Air Conditioner and Refrigerator
17
《China Standardization》 2005年第2期5-5,共1页
It is reported that from March 1 st, 2005, the energy efficiency label will be attached on the household refrigerators and air conditioners in China.
关键词 BE The Energy Efficiency Label to Be Attached on the air conditioner and Refrigerator
下载PDF
First Nano RE Air- conditioner
18
《China Rare Earth Information》 2002年第5期3-3,共1页
关键词 NANO First Nano RE air conditioner RE
下载PDF
Estimation of Vapor Quality at Compressor Suction of Air Conditioner
19
作者 Kazuhiro Endoh 《Journal of Energy and Power Engineering》 2015年第4期367-374,共8页
To evaluate performance and reliability of an air conditioner, the states of its refrigerant in the refrigeration cycle need to be understood. Since the isentropic exponent of the next-generation refrigerant R32 is la... To evaluate performance and reliability of an air conditioner, the states of its refrigerant in the refrigeration cycle need to be understood. Since the isentropic exponent of the next-generation refrigerant R32 is larger than that of conventional refrigerant R410A, the compressor discharge temperature of R32 is higher than that of R410A. When a wet refrigerant is entered into a compressor suction line to decrease the discharge temperature, it is generally difficult to estimate the vapor quality at the suction. This paper describes a method that estimates a vapor quality at the compressor suction by applying energy balances on the compressor with the values of suction pressure, discharge pressure, discharge temperature, etc. In the air conditioner test, the vapor qualities at the compressor suction estimated with this method agreed well with those estimated with the conventional method by measuring liquid and vapor flow-rates. Moreover, this paper derived a relational expression for estimating a compressor suction state from a discharge state and discusses the characteristics of the coefficients in the expression calculated from the test results. 展开更多
关键词 air conditioner COMPRESSOR wet refrigerant vapor quality R32.
下载PDF
Three National Compulsory Standards on Energy Efficiency of Air Conditioners Approved
20
《China Standardization》 2004年第6期12-13,共2页
关键词 Three National Compulsory Standards on Energy Efficiency of air conditioners Approved
下载PDF
上一页 1 2 218 下一页 到第
使用帮助 返回顶部