The horseshoe vortex generated around the sail-body junction of submarine has an important influence on the non-uniformity of submarine wake at propeller disc. The flow characteristics in the horseshoe vortex generate...The horseshoe vortex generated around the sail-body junction of submarine has an important influence on the non-uniformity of submarine wake at propeller disc. The flow characteristics in the horseshoe vortex generated area are analyzed, and a new method of vortex control baffler is presented. The influence of vortex control baffler on the flow field around submarine main body with sail is numerically simulated. The wind tunnel experiment on submarine model is carried out, and it is proved that the vortex control baffler can weaken the hoi-seshoe vortex and decrease the non-uniformity of the wake at propeller disc. It is shown from the experiment results that the effect of vortex control baffler depends on its installation position; with a proper installation position, the non-uniform coefficient of submarine wake would be declined by about 50%; the Reynolds number of submarine model has an influence on the effect of vortex control baffler too, and the higher the Reynolds number is, the better the effect of the vortex control baffler is.展开更多
An air-lift has been more recently applied in the dredging, deep-seated beach placer mining and underground mining engineering. However, the influence and mechanism of various parameters on the air-lift performance ar...An air-lift has been more recently applied in the dredging, deep-seated beach placer mining and underground mining engineering. However, the influence and mechanism of various parameters on the air-lift performance are not quite clear, especially the influence of flow pattern on lifting efficiency. Focusing on the problems mentioned above, the key part of the air-lift (namely, the air injector) was proposed aimed to reduce friction loss in the inner pipe according to improving flow field performance, thus increase the lifting efficiency. The study of relative factors of the performance of an air-lift is performed and the river sand is used as simulation of underground ore bed. The total lifting height of the experimental system is 3 m, the water flux, mass flow of solid particles, concentration of particles and lifting efficiency are measured under the same submergence ratios by changing the air injector, which is divided into nine specifications of air injection in this research. The experimental results indicate that the optimal air flow rate corresponding to excellent performance of the air-lift can be obtained in the range of 35-40 m3/h. The air injection method has a great effect on the performance of the air-lift, the air injector with three nozzles is better than that in the case of one or two nozzles. Further more, the air injection angle and arrangement of air injection pipes also have great effect on the performance of an air-lift. The proposed research results have guiding significance for engineering application.展开更多
为了提高氧化沟内水流的混掺能力,降低系统的运行能耗,对卡鲁塞尔(Carrousel)氧化沟的结构进行优化研究。采用数值计算方法求解气液两相流时均方程,辅以RNGk-ε紊流模型封闭时均方程组,自由面的追踪采用VOF(volume of fluid)方法处理,...为了提高氧化沟内水流的混掺能力,降低系统的运行能耗,对卡鲁塞尔(Carrousel)氧化沟的结构进行优化研究。采用数值计算方法求解气液两相流时均方程,辅以RNGk-ε紊流模型封闭时均方程组,自由面的追踪采用VOF(volume of fluid)方法处理,对六沟道试验氧化沟在曝气推流设备后增设导流板与无导流板2种工况下的水力特性进行研究。通过对比2种工况下的流速分布规律,得出在曝气转盘下游加装导流板时,不会导致氧化沟中上部污泥滞留,并能增大氧化沟底部水流速度,改善沟内垂线上的流速分布。在曝气推流设备后增设导流板来改善水力特性有利于消除氧化沟池底积泥现象,延长水气混掺时间,提高水处理效率。展开更多
Nitrogen removal from synthetic wastewater was investigated in an airlift bioreactor (ALB), augmented with a novel heterotrophic nitrifier Pseudonocardia ammonioxydans H9^T under organic carbon to nitrogen ratios (...Nitrogen removal from synthetic wastewater was investigated in an airlift bioreactor (ALB), augmented with a novel heterotrophic nitrifier Pseudonocardia ammonioxydans H9^T under organic carbon to nitrogen ratios (Corg/N) ranging from 0 to 12. Effect of the inoculated strain was also determined on the settling properties and the removal of chemical oxygen demand (COD). Two laboratory scale reactors were set up to achieve a stable nitrifying state under the same physicochemical conditions of hydraulic retention time (HRT), temperature, pH and dissolved oxygen (DO), and operated under the sequencing batch mode. The level of DO was kept at 0.5- 1.5 mg/L by periodic stirring and aeration. Each specific Corg/N ratio was continued for duration of 3 weeks. One of the reactors (BR2) was inoculated with P ammonioxydans H9^T periodically at the start of each Corg/N ratio. Sludge volumetric index (SVI) improved with the increasing Corg/N ratio, but no significant difference was detected between the two reactors. BR2 showed higher levels of nitrogen removal with the increasing heterotrophic conditions, and the ammonia removal reached to the level of 82%-88%, up to10% higher than that in the control reactor (BR1) at Corg/N ratios higher than 6; however, the ammonia removal level in experimental reactor was up to 8% lower than that in control reactor at Corg/N ratios lower than 2. The COD removal efficiency progressively increased with the increasing Corg/N ratios in both of the reactors. The COD removal percentage up to peak values of 88%-94% in BR2, up to 11% higher than that in BR1 at Corg/N ratio higher than 4. The peak values of ammonia and COD removal almost coincided with the highest number (18%-27% to total bacterial number) of the exogenous bacterium in the BR2, detected as colony forming units (CFU). Furthermore, the removal of ammonia and COD in BR2 was closely related to the number of the inoculated strain with a coefficient index (R2) up to 0.82 and 0.85 for ammonia and COD, respectively. These results suggest that it was more efficient for both the ammonia and carbon nutrient removals in a reactor inoculated with a heterotrophic nitrifier at high Corg/N ratio, inferring that the heterotrophic nitrifers would be practically more available in the treatment of wastewater with high level of ammonia and COD.展开更多
基金supported by the State Key Laboratory of Ocean Engineering,Shanghai Jiao Tong University(Grant No.0708)
文摘The horseshoe vortex generated around the sail-body junction of submarine has an important influence on the non-uniformity of submarine wake at propeller disc. The flow characteristics in the horseshoe vortex generated area are analyzed, and a new method of vortex control baffler is presented. The influence of vortex control baffler on the flow field around submarine main body with sail is numerically simulated. The wind tunnel experiment on submarine model is carried out, and it is proved that the vortex control baffler can weaken the hoi-seshoe vortex and decrease the non-uniformity of the wake at propeller disc. It is shown from the experiment results that the effect of vortex control baffler depends on its installation position; with a proper installation position, the non-uniform coefficient of submarine wake would be declined by about 50%; the Reynolds number of submarine model has an influence on the effect of vortex control baffler too, and the higher the Reynolds number is, the better the effect of the vortex control baffler is.
基金supported by Ministry of Science and Technology of China (Grant No. 2008DFA70300)
文摘An air-lift has been more recently applied in the dredging, deep-seated beach placer mining and underground mining engineering. However, the influence and mechanism of various parameters on the air-lift performance are not quite clear, especially the influence of flow pattern on lifting efficiency. Focusing on the problems mentioned above, the key part of the air-lift (namely, the air injector) was proposed aimed to reduce friction loss in the inner pipe according to improving flow field performance, thus increase the lifting efficiency. The study of relative factors of the performance of an air-lift is performed and the river sand is used as simulation of underground ore bed. The total lifting height of the experimental system is 3 m, the water flux, mass flow of solid particles, concentration of particles and lifting efficiency are measured under the same submergence ratios by changing the air injector, which is divided into nine specifications of air injection in this research. The experimental results indicate that the optimal air flow rate corresponding to excellent performance of the air-lift can be obtained in the range of 35-40 m3/h. The air injection method has a great effect on the performance of the air-lift, the air injector with three nozzles is better than that in the case of one or two nozzles. Further more, the air injection angle and arrangement of air injection pipes also have great effect on the performance of an air-lift. The proposed research results have guiding significance for engineering application.
文摘为了提高氧化沟内水流的混掺能力,降低系统的运行能耗,对卡鲁塞尔(Carrousel)氧化沟的结构进行优化研究。采用数值计算方法求解气液两相流时均方程,辅以RNGk-ε紊流模型封闭时均方程组,自由面的追踪采用VOF(volume of fluid)方法处理,对六沟道试验氧化沟在曝气推流设备后增设导流板与无导流板2种工况下的水力特性进行研究。通过对比2种工况下的流速分布规律,得出在曝气转盘下游加装导流板时,不会导致氧化沟中上部污泥滞留,并能增大氧化沟底部水流速度,改善沟内垂线上的流速分布。在曝气推流设备后增设导流板来改善水力特性有利于消除氧化沟池底积泥现象,延长水气混掺时间,提高水处理效率。
基金This work was supported by the National Natural Science Foundation of China (No. 30470024).
文摘Nitrogen removal from synthetic wastewater was investigated in an airlift bioreactor (ALB), augmented with a novel heterotrophic nitrifier Pseudonocardia ammonioxydans H9^T under organic carbon to nitrogen ratios (Corg/N) ranging from 0 to 12. Effect of the inoculated strain was also determined on the settling properties and the removal of chemical oxygen demand (COD). Two laboratory scale reactors were set up to achieve a stable nitrifying state under the same physicochemical conditions of hydraulic retention time (HRT), temperature, pH and dissolved oxygen (DO), and operated under the sequencing batch mode. The level of DO was kept at 0.5- 1.5 mg/L by periodic stirring and aeration. Each specific Corg/N ratio was continued for duration of 3 weeks. One of the reactors (BR2) was inoculated with P ammonioxydans H9^T periodically at the start of each Corg/N ratio. Sludge volumetric index (SVI) improved with the increasing Corg/N ratio, but no significant difference was detected between the two reactors. BR2 showed higher levels of nitrogen removal with the increasing heterotrophic conditions, and the ammonia removal reached to the level of 82%-88%, up to10% higher than that in the control reactor (BR1) at Corg/N ratios higher than 6; however, the ammonia removal level in experimental reactor was up to 8% lower than that in control reactor at Corg/N ratios lower than 2. The COD removal efficiency progressively increased with the increasing Corg/N ratios in both of the reactors. The COD removal percentage up to peak values of 88%-94% in BR2, up to 11% higher than that in BR1 at Corg/N ratio higher than 4. The peak values of ammonia and COD removal almost coincided with the highest number (18%-27% to total bacterial number) of the exogenous bacterium in the BR2, detected as colony forming units (CFU). Furthermore, the removal of ammonia and COD in BR2 was closely related to the number of the inoculated strain with a coefficient index (R2) up to 0.82 and 0.85 for ammonia and COD, respectively. These results suggest that it was more efficient for both the ammonia and carbon nutrient removals in a reactor inoculated with a heterotrophic nitrifier at high Corg/N ratio, inferring that the heterotrophic nitrifers would be practically more available in the treatment of wastewater with high level of ammonia and COD.