In unconsolidated sandstone reservoirs,presence of numerous movable grains and a complex grain size composition necessitates a clear understanding of the physical clogging process for effective groundwater recharge in...In unconsolidated sandstone reservoirs,presence of numerous movable grains and a complex grain size composition necessitates a clear understanding of the physical clogging process for effective groundwater recharge in groundwater-source heat pump systems.To investigate this,a series of seepage experiments was conducted under in situ stress conditions using unconsolidated sandstone samples with varying grain compositions.The clogging phenomenon arises from the combined effects of grain migration and compaction,wherein the migration of both original and secondary crushed fine-grain particles blocks the seepage channels.Notably,grain composition influences the migration and transport properties of the grains.For samples composed of smaller grains,the apparent permeability demonstrates a transition from stability to decrease.In contrast,samples with larger grains experience a skip at the stability stage and directly enter the decrease stage,with a minor exception of a slight increase observed.Furthermore,a unique failure mode characterized by diameter shrinkage in the upper part of the sample is observed due to the combined effects of grain migration and in situ stress-induced compaction.These testing results contribute to a better understanding of the clogging mechanism caused by the coupled effects of grain migration and compaction during groundwater recharge in unconsolidated sandstone reservoirs used in groundwater-source heat pump systems.展开更多
The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking c...The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking central heating. However, as a major component of space heating, heating terminals might not fit well with ASHP in order to achieve both intermittency and comfort. Therefore, this study proposes a novel radiation-adjustable heating terminal combined with an ASHP to achieve electrification, intermittency, and better thermal comfort. Radiant terminals currently suffer from three major problems: limited maximum heating capacity, inability to freely adapt, and difficulty with combining them with ASHPs. These problems were solved by improving the structural design of the novel terminal (Improvement A–E). Results showed that the maximum heating capacity increased by 23.6% and radiation heat transfer ratio from 10.1% to 30.9% was provided for users with the novel terminal. Further, new flat heat pipe (FHP) design improved stability (compressor oil return), intermittency (refrigerant thermal inertia), and safety (refrigerant leakage risk) by reducing the length of exposed refrigerant pipes. Furthermore, a new phased operation strategy was proposed for the novel terminal, and the adjustability of the terminal was improved. The results can be used as reference information for decarbonizing buildings by electrifying heating terminals.展开更多
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr...To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.展开更多
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e...For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.展开更多
With the implementation of electric energy alternatives,the large-scale application of electric energy substitution represented by air-source heat pumps has replaced traditional coal-fired heating,which is beneficial ...With the implementation of electric energy alternatives,the large-scale application of electric energy substitution represented by air-source heat pumps has replaced traditional coal-fired heating,which is beneficial for the environment and alleviates air pollution.However,the large-scale application of airsource heat pumps has brought power quality problems such as voltage sags,harmonic pollution,and three-phase imbalance to the distribution network.This paper studies the fixed-frequency and variablefrequency air-source heat pump,introduces its working principle,analyzes the mechanism of its power quality problem.Moreover,the paper establishes a simulation model for the fixed-frequency heat pump and variable-frequency heat pump to connect to the distribution network.This research mainly studies the impact of large-scale fixed-frequency heat pumps on the depth of voltage sags in the distribution network and the impact of large-scale variable-frequency heat pumps on the harmonic content of the distribution network under different penetration rates and uses measured data to verify the reliability of the simulation results.This paper uses experimental data for the first time to verify the real power quality problems of large-scale heat pumps,which can provide a reference for determining the power quality standards for heat pumps connected to the power grid.At the same time,it can also provide a reference for the power quality management of the distribution network that is actually connected to electric heating.展开更多
The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ...The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ternary mixture. The proposed scheme is optimized via the simulated annealing algorithm and minimum total annual cost(TAC) is used as objective functions. To minimize energy consumption,heat pump is added on the basis of optimal heterogeneous azeotropic distillation and heat integration technology is used to further improve the energy recovery. The TAC, gas emission, energy consumption and exergy destruction are used to discuss the economy and environmental protection of processes.Among all the processes, the heat pump with higher preheating temperature(HPT) assisted HAD process by combining with heat integration(HAD-HPT-HI) has best performances on economic, environment,energy and exergy. Compared with conventional HAD process, the HAD-HPT-HI achieves the reductions of 52.17%, 68.86%, 65.87% and 65.46% on TAC, total energy consumption, gas emissions and exergy destruction, respectively.展开更多
The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column...The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column. However, the separation of wide-boiling binary mixtures leads to substantial temperature differences between the top and bottom of the column. This limits the applicability of conventional VRHP due to high capital costs and strict performance requirements of the compressor. To overcome these challenges and to accommodate compressor operating conditions, a novel synthesis and design method is introduced to integrate VRHPs with wide-boiling binary mixture distillation columns(WBMDCs). This method enables quick determination of an initial configuration for the integrated WBMDC-VRHP system and helps identify the optimum configuration with the minimum total annual cost. Two examples, namely the separation of benzene/toluene and isopropanol/chlorobenzene, are employed to derive optimum configurations of the WBMDC-VRHP and compare them with the WBMDC. A systematic comparison between the WBMDC-VRHP and WBMDC demonstrates the superior steady-state performance and economic efficiency of the WBMDC-VRHP.展开更多
A hybrid heat pump(compression/absorption)with an integrated thermal photovoltaic unit is studied.The considered working fluids are organic mixtures:R245fa/DMAC and R236fa/DMAC,chosen for their low Global Warming Pote...A hybrid heat pump(compression/absorption)with an integrated thermal photovoltaic unit is studied.The considered working fluids are organic mixtures:R245fa/DMAC and R236fa/DMAC,chosen for their low Global Warming Potential.The main objective is the optimization of energy efficiency in order to minimize the environmental impact through the implementation of a sustainable strategy.It is shown that Exergy Analysis itself is a valuable tool in energy integration.Within the imposed framework of minimizing total annual costs,entropy analysis can be instrumental in determining the optimal plant concept,optimizing energy conversion and use,and improving profitability.The present results are discussed under the optimistic hope that they may help to define new energy and environmental policies.展开更多
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is...Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price.展开更多
Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public...Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public buildings,play a key role in adapting to PDEF systems.This research studied the basic principles and operational control strategies of a DC inverter heat pump using a DC distribution network with the aim of contributing to the development and application of small DC distribution systems.Along with the characteristics of a DC distribution network and different operating conditions,a DC inverter heat pump has the ability to adapt to changes in the DC bus voltage and adds flexibility to the system.Theoretical models of the DC inverter heat pump integrated with an ice storage unit were developed.The control strategies of the DC inverter heat pump system considered the influence of both room temperature and varied bus voltage.A simulation study was conducted using MATLAB&Simulink software with simulation results validated by experimental data.The results showed that:(1)The bus fluctuation under the rated working voltage had little effect on the operation of the unit;(2)When the bus voltage was fluctuating from 80%-90%or 105%-107%,the heat pump could still operate normally by reducing the frequency;(3)When the bus voltage was less than 80%or more than 107%,the unit needed to be shut down for the sake of equipment safety,so that the energy storage device could adjust to the sharp decrease or rise of voltage.展开更多
The paper deals with the impact of a mechanical compression heat pump, operated by electrical energy, on the environment. Irrespective of its origin and the history of its production, this energy pollutes the environm...The paper deals with the impact of a mechanical compression heat pump, operated by electrical energy, on the environment. Irrespective of its origin and the history of its production, this energy pollutes the environment as waste heat. The operational energy, obtained from the so-called alternative energy sources (wind, water energy), also burdens the environment as waste heat. This is not the case with the solar energy. A direct conversion of the Sun’s rays into electricity does not additionally affect the environment, compared to their direct conversion into heat without our intervention.展开更多
In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400...In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 °C) and condenser water inlet temperature(30-50 °C). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 °C to 17.8 °C, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 °C to 50 °C. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature.展开更多
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ...An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.展开更多
A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water t...A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.展开更多
An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The...An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs.展开更多
The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, ...The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, the major obstacle hindering the utilization of this technology is the high initial cost, especially for the installation of ground coupled heat exchanger. The horizontal closed-loop system offers lower installation cost, as it requires no vertical borehole construction. Instead, the heat exchangers can be installed in shallow trenches that may be excavated, by small excavator or even by human labor. This paper presents the comparison of two different heat exchangers, namely, the capillary mat and the widely used slinky pipe. Both heat exchangers are connected to a heat pump, where continuous heating tests were carried out for 165 hours (~7 days) for each configuration. The purpose of this research is to show the performance of capillary mat in comparison to slinky pipe. Despite during the entire test for capillary mat required 6% higher electricity consumption, compared to slinky heat exchanger, the results still suggest the potential use of capillary mat as alternative to slinky heat exchanger. Additionally, the results also highlight the high hydraulic resistance of installed capillary mat heat exchangers may become the major disadvantage of the capillary mat.展开更多
The building sector contributes a large ratio of final energy consumption,and improving building energy efficiency is expected to play a significant role in mitigating its carbon dioxide emission.Herein,we collected t...The building sector contributes a large ratio of final energy consumption,and improving building energy efficiency is expected to play a significant role in mitigating its carbon dioxide emission.Herein,we collected the on-site measurement data to investigate the techno-economic performances of different heat pump types that exist in building space heating projects in Qingdao,China.An in-depth analysis revealed the temperature variations of measured low-grade heat sources over the whole heating supply period,and urban sewage water shows high stable heat energy quality compared with seawater and geothermal heat resources.Operational behaviors including cycling inlet and outlet temperature of the selected heat pumps were illustrated,and analysis evaluated detailed effects of operational parameters on energy efficiency performances.Then the relationship between COPs distributions of heat pumps and operational conditions was examined further,and the positive effect of the rising temperature of heat sources on energy efficiency improvement of heat pump is highlighted when the heating supply temperature is higher.Furthermore,we analyzed the economic and carbon emission performance of the heat pump system,and results show that electricity price plays a vital role in the lifespan energy cost saving potential,and the heat pump could serve as a promising approach in reducing CO_(2) related to the building space heating.Finally,we recommended suggestions for improving the overall energy efficiency and cost competitiveness of decentralized heat pump systems for building space heating.展开更多
The screw air-source heat pump can cause incessant high noise levels during operation,which might hinder adoption of this energy-efficient heat pump.First,acoustic measurements and comparison testing were performed in...The screw air-source heat pump can cause incessant high noise levels during operation,which might hinder adoption of this energy-efficient heat pump.First,acoustic measurements and comparison testing were performed in this research.The measurements revealed that the compressor is the main noise source of the heat pump,and it shows a multipeak frequency distribution and a wide frequency spectrum under different work conditions,with multiple peaks at 63,250,and 1000 Hz.Then,a compressor sound insulation cover with broadband absorption was proposed,and it was experimentally proven that the insulation cover can reduce the maximum sound pressure level of one unit from 89.8 dBA to 79.1 dBA.Third,we proposed several noise reduction strategies and compared their noise reduction effects using computer simulation.The results showed that the noise problem can be effectively improved through the rational design of the sound barrier and the layout and opening options of heat pump.The distance between the sound barrier and heat pump and the sound attenuation due to diffraction ALa exhibit a U-shaped relation.For buildings of different heights,the optimal heights of noise barrier are proposed.The 5.5-meter is the optimal height of the sound barrier for single-story buildings.The conclusions can be applied to other building projects for heat pump noise reduction.展开更多
This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calcu...This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively.展开更多
基金supported by the National Key Research and Development Program of China(Grant No.2022YFE0137200)National Natural Science Foundation of China(Grant Nos.52309147 and 52179114).
文摘In unconsolidated sandstone reservoirs,presence of numerous movable grains and a complex grain size composition necessitates a clear understanding of the physical clogging process for effective groundwater recharge in groundwater-source heat pump systems.To investigate this,a series of seepage experiments was conducted under in situ stress conditions using unconsolidated sandstone samples with varying grain compositions.The clogging phenomenon arises from the combined effects of grain migration and compaction,wherein the migration of both original and secondary crushed fine-grain particles blocks the seepage channels.Notably,grain composition influences the migration and transport properties of the grains.For samples composed of smaller grains,the apparent permeability demonstrates a transition from stability to decrease.In contrast,samples with larger grains experience a skip at the stability stage and directly enter the decrease stage,with a minor exception of a slight increase observed.Furthermore,a unique failure mode characterized by diameter shrinkage in the upper part of the sample is observed due to the combined effects of grain migration and in situ stress-induced compaction.These testing results contribute to a better understanding of the clogging mechanism caused by the coupled effects of grain migration and compaction during groundwater recharge in unconsolidated sandstone reservoirs used in groundwater-source heat pump systems.
基金supported by the National Science Foundation for Distinguished Young Scholars of China(51825802).
文摘The electrification of building heating is an effective way to meet the global carbon target. As a clean and sustainable electrified heating technology, air-source heat pumps (ASHPs) are widely used in areas lacking central heating. However, as a major component of space heating, heating terminals might not fit well with ASHP in order to achieve both intermittency and comfort. Therefore, this study proposes a novel radiation-adjustable heating terminal combined with an ASHP to achieve electrification, intermittency, and better thermal comfort. Radiant terminals currently suffer from three major problems: limited maximum heating capacity, inability to freely adapt, and difficulty with combining them with ASHPs. These problems were solved by improving the structural design of the novel terminal (Improvement A–E). Results showed that the maximum heating capacity increased by 23.6% and radiation heat transfer ratio from 10.1% to 30.9% was provided for users with the novel terminal. Further, new flat heat pipe (FHP) design improved stability (compressor oil return), intermittency (refrigerant thermal inertia), and safety (refrigerant leakage risk) by reducing the length of exposed refrigerant pipes. Furthermore, a new phased operation strategy was proposed for the novel terminal, and the adjustability of the terminal was improved. The results can be used as reference information for decarbonizing buildings by electrifying heating terminals.
文摘To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001)Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
文摘For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.
基金Science and Technology Project of State Grid Corporation of China,Scale application and benefit evaluation of typical power substitution technology considering the influence of power quality(52182018000H).
文摘With the implementation of electric energy alternatives,the large-scale application of electric energy substitution represented by air-source heat pumps has replaced traditional coal-fired heating,which is beneficial for the environment and alleviates air pollution.However,the large-scale application of airsource heat pumps has brought power quality problems such as voltage sags,harmonic pollution,and three-phase imbalance to the distribution network.This paper studies the fixed-frequency and variablefrequency air-source heat pump,introduces its working principle,analyzes the mechanism of its power quality problem.Moreover,the paper establishes a simulation model for the fixed-frequency heat pump and variable-frequency heat pump to connect to the distribution network.This research mainly studies the impact of large-scale fixed-frequency heat pumps on the depth of voltage sags in the distribution network and the impact of large-scale variable-frequency heat pumps on the harmonic content of the distribution network under different penetration rates and uses measured data to verify the reliability of the simulation results.This paper uses experimental data for the first time to verify the real power quality problems of large-scale heat pumps,which can provide a reference for determining the power quality standards for heat pumps connected to the power grid.At the same time,it can also provide a reference for the power quality management of the distribution network that is actually connected to electric heating.
基金financial support provided by the National Natural Science Foundation of China (22178030, 21878025, and 22078026)。
文摘The conventional distillation is hard to accomplish the separation of acetonitrile/ethyl acetate/n-hexane mixture. Herein, a heterogeneous azeotropic distillation(HAD) without adding entrainer is proposed to separate ternary mixture. The proposed scheme is optimized via the simulated annealing algorithm and minimum total annual cost(TAC) is used as objective functions. To minimize energy consumption,heat pump is added on the basis of optimal heterogeneous azeotropic distillation and heat integration technology is used to further improve the energy recovery. The TAC, gas emission, energy consumption and exergy destruction are used to discuss the economy and environmental protection of processes.Among all the processes, the heat pump with higher preheating temperature(HPT) assisted HAD process by combining with heat integration(HAD-HPT-HI) has best performances on economic, environment,energy and exergy. Compared with conventional HAD process, the HAD-HPT-HI achieves the reductions of 52.17%, 68.86%, 65.87% and 65.46% on TAC, total energy consumption, gas emissions and exergy destruction, respectively.
文摘The vapor recompression heat pump(VRHP) distillation technology offers significant improvements in energy efficiency for distillation systems with small temperature differences between the top and bottom of the column. However, the separation of wide-boiling binary mixtures leads to substantial temperature differences between the top and bottom of the column. This limits the applicability of conventional VRHP due to high capital costs and strict performance requirements of the compressor. To overcome these challenges and to accommodate compressor operating conditions, a novel synthesis and design method is introduced to integrate VRHPs with wide-boiling binary mixture distillation columns(WBMDCs). This method enables quick determination of an initial configuration for the integrated WBMDC-VRHP system and helps identify the optimum configuration with the minimum total annual cost. Two examples, namely the separation of benzene/toluene and isopropanol/chlorobenzene, are employed to derive optimum configurations of the WBMDC-VRHP and compare them with the WBMDC. A systematic comparison between the WBMDC-VRHP and WBMDC demonstrates the superior steady-state performance and economic efficiency of the WBMDC-VRHP.
文摘A hybrid heat pump(compression/absorption)with an integrated thermal photovoltaic unit is studied.The considered working fluids are organic mixtures:R245fa/DMAC and R236fa/DMAC,chosen for their low Global Warming Potential.The main objective is the optimization of energy efficiency in order to minimize the environmental impact through the implementation of a sustainable strategy.It is shown that Exergy Analysis itself is a valuable tool in energy integration.Within the imposed framework of minimizing total annual costs,entropy analysis can be instrumental in determining the optimal plant concept,optimizing energy conversion and use,and improving profitability.The present results are discussed under the optimistic hope that they may help to define new energy and environmental policies.
基金supported by the Carbon Peak and Carbon Neutralization Science and Technology Innovation Special Fund of Jiangsu Province,China(No.BE2022859)Natural Science Foundation of Guangdong Province,China(No.2021A1515011763).
文摘Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price.
基金funded by State Grid Science&Technology Project“Research and Demonstration of Key Technologies on Electric-Heating Collaboration Cross-Network Mutual Supply for Typical Regional Clean Energy”,Grant Number 5400-202111575A-0-5-SF.
文摘Photovoltaics,energy storage,direct current and flexibility(PEDF)are important pillars of achievement on the path to manufacturing nearly zero energy buildings(NZEBs).HVAC systems,which are an important part of public buildings,play a key role in adapting to PDEF systems.This research studied the basic principles and operational control strategies of a DC inverter heat pump using a DC distribution network with the aim of contributing to the development and application of small DC distribution systems.Along with the characteristics of a DC distribution network and different operating conditions,a DC inverter heat pump has the ability to adapt to changes in the DC bus voltage and adds flexibility to the system.Theoretical models of the DC inverter heat pump integrated with an ice storage unit were developed.The control strategies of the DC inverter heat pump system considered the influence of both room temperature and varied bus voltage.A simulation study was conducted using MATLAB&Simulink software with simulation results validated by experimental data.The results showed that:(1)The bus fluctuation under the rated working voltage had little effect on the operation of the unit;(2)When the bus voltage was fluctuating from 80%-90%or 105%-107%,the heat pump could still operate normally by reducing the frequency;(3)When the bus voltage was less than 80%or more than 107%,the unit needed to be shut down for the sake of equipment safety,so that the energy storage device could adjust to the sharp decrease or rise of voltage.
文摘The paper deals with the impact of a mechanical compression heat pump, operated by electrical energy, on the environment. Irrespective of its origin and the history of its production, this energy pollutes the environment as waste heat. The operational energy, obtained from the so-called alternative energy sources (wind, water energy), also burdens the environment as waste heat. This is not the case with the solar energy. A direct conversion of the Sun’s rays into electricity does not additionally affect the environment, compared to their direct conversion into heat without our intervention.
基金Project(hx2013-87)supported by the Qingdao Economic and Technology Development Zone Haier Water-Heater Co.Ltd.,China
文摘In order to evaluate the heating performance of gas engine heat pump(GEHP) for air-conditioning and hot water supply, a test facility was developed and experiments were performed over a wide range of engine speed(1400-2600 r/min), ambient air temperature(2.4-17.8 °C) and condenser water inlet temperature(30-50 °C). The results show that as engine speed increases from 1400 r/min to 2600 r/min, the total heating capacity and energy consumption increase by about 30% and 89%, respectively; while the heat pump coefficient of performance(COP) and system primary energy ratio(PER) decrease by 44% and 31%, respectively. With the increase of ambient air temperature from 2.4 °C to 17.8 °C, the heat pump COP and system PER increase by 32% and 19%, respectively. Moreover, the heat pump COP and system PER decrease by 27% and 15%, respectively, when the condenser water inlet temperature changes from 30 °C to 50 °C. So, it is obvious that the effect of engine speed on the performance is more significant than the effects of ambient air temperature and condenser water inlet temperature.
基金Supported bythe"11th Five-Year Plan"for National Plans of Major Technology Projects
文摘An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.
基金Project(2006BAJ03A06) supported by National Science and Technology Pillar Program During 11th Five-Year Plan
文摘A solar-water compound source heat pump for radiant floor heating (SWHP-RFH) experimental system was introduced and analyzed. The SWHP-RFH system mainly consists of 11.44 m2 vacuum tube solar collector,1 000 L water tank assisted 3 kW electrical heater,a water source heat pump,the radiant floor heating system with cross-linked polyethylene (PE-X) of diameter 20 mm,temperature controller and solar testing system. The SWHP-RFH system was tested from December to February during the heating season in Beijing,China under different operation situations. The test parameters include the outdoor air temperature,solar radiation intensity,indoor air temperature,radiation floor average surface temperature,average surface temperature of the building envelope,the inlet and outlet temperatures of solar collector,the temperature of water tank,the heat medium temperatures of heat pump condenser side and evaporator side,and the power consumption includes the water source heat pump system,the solar source heat pump system,the auxiliary heater and the radiant floor heating systems etc. The experimental results were used to calculate the collector efficiency,heat pump dynamic coefficient of performance (COP),total energy consumption and seasonal heating performance during the heating season. The results indicate that the performance of the compound source heat pump system is better than that of the air source heat pump system. Furthermore,some methods are suggested to improve the thermal performance of each component and the whole SWHP-RFH system.
基金supported by the National Key Research and Development Program of China(No.2016YFB0601602)National Natural Science Foundation of China(No.51676199)
文摘An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs.
文摘The cooling and heating of spaces are among the largest sources for household’s energy demand. Ground Source Heat Pump (GSHP) is a promising technology to reduce the energy for cooling and heating purposes. However, the major obstacle hindering the utilization of this technology is the high initial cost, especially for the installation of ground coupled heat exchanger. The horizontal closed-loop system offers lower installation cost, as it requires no vertical borehole construction. Instead, the heat exchangers can be installed in shallow trenches that may be excavated, by small excavator or even by human labor. This paper presents the comparison of two different heat exchangers, namely, the capillary mat and the widely used slinky pipe. Both heat exchangers are connected to a heat pump, where continuous heating tests were carried out for 165 hours (~7 days) for each configuration. The purpose of this research is to show the performance of capillary mat in comparison to slinky pipe. Despite during the entire test for capillary mat required 6% higher electricity consumption, compared to slinky heat exchanger, the results still suggest the potential use of capillary mat as alternative to slinky heat exchanger. Additionally, the results also highlight the high hydraulic resistance of installed capillary mat heat exchangers may become the major disadvantage of the capillary mat.
基金This research was funded by Development of the Healthy and Low-Carbon Residential House with Smart Home Environment Management System,Grant No.2019GSF110003Research on the energy efficiency and health performance improvement of building operations based on lifecycle carbon emissions reduction Grant No.2018YFE0106100.We gratefully acknowledge the help from ASSURAN International Scholarship Foundation.
文摘The building sector contributes a large ratio of final energy consumption,and improving building energy efficiency is expected to play a significant role in mitigating its carbon dioxide emission.Herein,we collected the on-site measurement data to investigate the techno-economic performances of different heat pump types that exist in building space heating projects in Qingdao,China.An in-depth analysis revealed the temperature variations of measured low-grade heat sources over the whole heating supply period,and urban sewage water shows high stable heat energy quality compared with seawater and geothermal heat resources.Operational behaviors including cycling inlet and outlet temperature of the selected heat pumps were illustrated,and analysis evaluated detailed effects of operational parameters on energy efficiency performances.Then the relationship between COPs distributions of heat pumps and operational conditions was examined further,and the positive effect of the rising temperature of heat sources on energy efficiency improvement of heat pump is highlighted when the heating supply temperature is higher.Furthermore,we analyzed the economic and carbon emission performance of the heat pump system,and results show that electricity price plays a vital role in the lifespan energy cost saving potential,and the heat pump could serve as a promising approach in reducing CO_(2) related to the building space heating.Finally,we recommended suggestions for improving the overall energy efficiency and cost competitiveness of decentralized heat pump systems for building space heating.
基金supported by the National Key R&D Program of China(No.2021YFB1507203)the National Natural Science Foundation of China(No.51838007).
文摘The screw air-source heat pump can cause incessant high noise levels during operation,which might hinder adoption of this energy-efficient heat pump.First,acoustic measurements and comparison testing were performed in this research.The measurements revealed that the compressor is the main noise source of the heat pump,and it shows a multipeak frequency distribution and a wide frequency spectrum under different work conditions,with multiple peaks at 63,250,and 1000 Hz.Then,a compressor sound insulation cover with broadband absorption was proposed,and it was experimentally proven that the insulation cover can reduce the maximum sound pressure level of one unit from 89.8 dBA to 79.1 dBA.Third,we proposed several noise reduction strategies and compared their noise reduction effects using computer simulation.The results showed that the noise problem can be effectively improved through the rational design of the sound barrier and the layout and opening options of heat pump.The distance between the sound barrier and heat pump and the sound attenuation due to diffraction ALa exhibit a U-shaped relation.For buildings of different heights,the optimal heights of noise barrier are proposed.The 5.5-meter is the optimal height of the sound barrier for single-story buildings.The conclusions can be applied to other building projects for heat pump noise reduction.
基金Supported by National Natural Science Foundation of China(No.1272263)
文摘This paper presents the heating performance and energy distribution of a system with the combination of ground-source heat pump and solar collector or a solar-assisted ground-source heat pump system (SAGSHPS) by calculation and experiment.The results show that the average absolute error is less than 0.6 ℃ and the relative error is less than 5% under the pulse load when the analytical solution to the 2-D solid cylindrical source model is used for the SAGSHPS.The coefficient of performance (COP) of the SAGSHPS is 2.95-4.70.The average fluid temperature in the borehole heat exchanger can increase by 3 ℃ with the assistance of solar collector,which will improve the COP of the heat pump by approximately 10% from the experimental data.The energy contributions to the total heating load of soil,electricity and solar are 56.30%,36.87% and 6.83%,respectively.