The present work has dealt extensively and systematically with the fading characteristics of polystyrene-alanine dosimeters irradiated at different dose rates and total doses under various temperatures (10-70 ℃) and ...The present work has dealt extensively and systematically with the fading characteristics of polystyrene-alanine dosimeters irradiated at different dose rates and total doses under various temperatures (10-70 ℃) and stored a period of time in different conditions (5, 25, room temperature, 40 ℃). Detail investigation on this effect in practical irradiation condition is very important. Because it is difficult to correct this effect using correction coefficients so far. So the temperature coefficients and fading rates have been given along with a lot of experimental data to try to make approximation of radical formation or decay behavior.展开更多
In this report, the results of preliminary research on L-alanine/ESR electron dosimeters are described. They include the designs of modelling tools and experimental capsules, the preparation and irradiation of very th...In this report, the results of preliminary research on L-alanine/ESR electron dosimeters are described. They include the designs of modelling tools and experimental capsules, the preparation and irradiation of very thin dosimeters, the measurement of ESR signal spectrum and the calibration method. The physical, chemical and dosimetric properties of the alanine free radical dosimeters, such as the smallest thickness, average density, lowest detectable limit, repeatability of the method, reproducibility resulted in directivity and location in resonance cavity, linearity regions as well as relative scattering of the response to identical doses, are summarized.展开更多
Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurem...Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurements are required. Electron Spin Resonance (ESR) is a well-established Reference Standard Dosimetry system in industrial applications of ionising radiation, and its use is also proposed in radiation therapy and accident dosimetry. In the present experimental work, PGA solid state dosimeter (SSD) has been investigated using ESR spectroscopy to study the gamma radiation response of this material and to evaluate its dosimetric characteristics: dose response, room temperature fading, heat treatment effect during post-irradiation storage. Results obtained up to now confirm that PGA seems to be suitable material for ESR dosimetry applications.展开更多
Dose inter-comparison studies for Co γ-ray and 10 MeV electron beam irradiation were carried out 60 from July to October in 2002. The purpose of the studies was to check the reliability of the alanine-PE film dosime-...Dose inter-comparison studies for Co γ-ray and 10 MeV electron beam irradiation were carried out 60 from July to October in 2002. The purpose of the studies was to check the reliability of the alanine-PE film dosime- ters made by CIAE, which will be used as transfer standard dosimetry system mainly for electron beam irradiation. The expanded uncertainty of CIAE alanine/EPR dosimetry system was 4.1% for doses not higher than 10 kGy and 5.4% for those above 10 kGy (k=2). CIAE alanine-PE film dosimeters were sent to JAERI, RISO (National Labora- tory in Denmark) and INCT respectively, which were irradiated by Co gamma-rays or electron beams in each labo- 60 ratory. The irradiated dosimeters were then sent back to CIAE for electron paramagnetic resonance (EPR) analysis. The agreements were obtained to be ±1.9% for gamma-ray dose measurement and ±4.3% for electron beam dose measurement, which were all within the combined uncertainty of the reference and CIAE alanine/EPR dosimetry system. Furthermore, the overall mean ratio was found to be 0.995 with 1.8% in the coefficient of variation (CV). The preliminary inter-comparison studies indicated that CIAE film alanine/EPR dosimetry system had the potential to be used as a transfer dosimetry system for high dose measurement.展开更多
基金The Project was Supported by IAEA and Completed in Japanese Atomic Energy Research Institute
文摘The present work has dealt extensively and systematically with the fading characteristics of polystyrene-alanine dosimeters irradiated at different dose rates and total doses under various temperatures (10-70 ℃) and stored a period of time in different conditions (5, 25, room temperature, 40 ℃). Detail investigation on this effect in practical irradiation condition is very important. Because it is difficult to correct this effect using correction coefficients so far. So the temperature coefficients and fading rates have been given along with a lot of experimental data to try to make approximation of radical formation or decay behavior.
基金This project was supported by IAEA under the research contact No. 4236/RB/R1
文摘In this report, the results of preliminary research on L-alanine/ESR electron dosimeters are described. They include the designs of modelling tools and experimental capsules, the preparation and irradiation of very thin dosimeters, the measurement of ESR signal spectrum and the calibration method. The physical, chemical and dosimetric properties of the alanine free radical dosimeters, such as the smallest thickness, average density, lowest detectable limit, repeatability of the method, reproducibility resulted in directivity and location in resonance cavity, linearity regions as well as relative scattering of the response to identical doses, are summarized.
文摘Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurements are required. Electron Spin Resonance (ESR) is a well-established Reference Standard Dosimetry system in industrial applications of ionising radiation, and its use is also proposed in radiation therapy and accident dosimetry. In the present experimental work, PGA solid state dosimeter (SSD) has been investigated using ESR spectroscopy to study the gamma radiation response of this material and to evaluate its dosimetric characteristics: dose response, room temperature fading, heat treatment effect during post-irradiation storage. Results obtained up to now confirm that PGA seems to be suitable material for ESR dosimetry applications.
文摘Dose inter-comparison studies for Co γ-ray and 10 MeV electron beam irradiation were carried out 60 from July to October in 2002. The purpose of the studies was to check the reliability of the alanine-PE film dosime- ters made by CIAE, which will be used as transfer standard dosimetry system mainly for electron beam irradiation. The expanded uncertainty of CIAE alanine/EPR dosimetry system was 4.1% for doses not higher than 10 kGy and 5.4% for those above 10 kGy (k=2). CIAE alanine-PE film dosimeters were sent to JAERI, RISO (National Labora- tory in Denmark) and INCT respectively, which were irradiated by Co gamma-rays or electron beams in each labo- 60 ratory. The irradiated dosimeters were then sent back to CIAE for electron paramagnetic resonance (EPR) analysis. The agreements were obtained to be ±1.9% for gamma-ray dose measurement and ±4.3% for electron beam dose measurement, which were all within the combined uncertainty of the reference and CIAE alanine/EPR dosimetry system. Furthermore, the overall mean ratio was found to be 0.995 with 1.8% in the coefficient of variation (CV). The preliminary inter-comparison studies indicated that CIAE film alanine/EPR dosimetry system had the potential to be used as a transfer dosimetry system for high dose measurement.