期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Electrical Characteristics of an Alternating Current Plasma Igniter in Airflow
1
作者 赵兵兵 何立明 +1 位作者 杜宏亮 张华磊 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第4期370-373,共4页
The electrical characteristics of an alternating current (AC) plasma igniter were investigated for a working gas of air at atmospheric pressure. The discharge voltage and current were measured in air in both breakdo... The electrical characteristics of an alternating current (AC) plasma igniter were investigated for a working gas of air at atmospheric pressure. The discharge voltage and current were measured in air in both breakdown and stable combustion processes, respectively, and the current-zero phenomena, voltage-current (V-I) characteristics were studied for different working gas flow rates. The results indicated that the working gas between anode and cathode could be ionized to generate gas discharge when the voltage reached 8 kV, and the maximum current was 33.36 A. When the current came to zero, current-zero phenomena appeared with duration of 2 #s. At the current-zero moment, dynamic resistance between electrodes became extremely high, and the maximum value could reach 445 kf~, which was the main factor to restrain the current. With increasing working gas flow rates, the gradient of V-I characteristic curves was increased, as was the dynamic resistance. At a constant driven power, the discharge voltage increased. 展开更多
关键词 alternating current discharge plasma igniter voltage-current characteristic current-zero phenomena
下载PDF
Flow separation control over an airfoil using continuous alternating current plasma actuator 被引量:1
2
作者 Jian-Guo Zheng 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第3期346-355,共10页
The flow separation control over an NACA 0015 airfoil using continuous alternating current(AC)dielectric barrier discharge(DBD)plasma actuator is investigated experimentally and numerically.This work is intended to re... The flow separation control over an NACA 0015 airfoil using continuous alternating current(AC)dielectric barrier discharge(DBD)plasma actuator is investigated experimentally and numerically.This work is intended to report some observations made from our experiment,to which little attention is paid in the previous studies,but which is thought to be important to the understanding of control of complex flow separation with AC DBD.To this end,the response of separated flow to AC plasma actuation is visualized through the time-resolved particle image velocimetry(PIV)measurement,whereas numerical simulation is carried out to complement the experiment.The flow control process at chord-based Reynolds number(Re)of 3.31×105 is investigated.It is found that the response of external flow to plasma forcing is delayed for up to tens of milliseconds and the delay time increases with angle of attack increasing.Also observed is that at the intermediate angle of attack near stall,the forced flow features a well re-organized flow pattern.However,for airfoil at high post-stall angle of attack,the already well suppressed flow field can recover to the massively separated flow state and then reattach to airfoil surface with the flow pattern fluctuating between the two states in an irregular manner.This is contrary to one’s first thought that the forced flow at any angles of attack will become well organized and regular,and reflects the complexity of flow separation control. 展开更多
关键词 dielectric barrier discharge plasma actuator alternating current plasma discharge flow separation flow control delayed response
下载PDF
Comparison of the effect of different external electrodes on discharge plasma-assisted diffusion flame stabilization
3
作者 Siyin ZHOU Xiang LIU +1 位作者 Wansheng NIE Shuhui YUAN 《Plasma Science and Technology》 SCIE EI CAS 2024年第10期123-132,共10页
To optimize the design of plasma injectors,the influence of different external electrodes on plasma-assisted flame stabilization was assessed by using a nonequilibrium plasma injector flame control setup.The electrica... To optimize the design of plasma injectors,the influence of different external electrodes on plasma-assisted flame stabilization was assessed by using a nonequilibrium plasma injector flame control setup.The electrical characteristics of the injector,flame structure parameters,flame intensity,discharge power,and cost-to-effectiveness ratio under different external electrodes(four mesh electrodes and one copper foil electrode)were analyzed using electrical and optical methods.The results show that reducing the mesh size of the external electrode leads to a decrease in breakdown voltage.Compared with a ceramic dielectric barrier-based injector,an injector with a quartz dielectric barrier produces a higher breakdown voltage under the same conditions.For the same actuation voltage,the discharge current increases as the mesh size of the external electrode decreases,and combustion is enhanced by the discharge plasma;therefore,it is better to adopt a smaller mesh hole size to realize good flame stabilization under a lower actuation voltage.However,under the studied working conditions,reducing the mesh hole size of the external electrode increases the cost-to-effectiveness ratio of plasma injector-based flame stabilization.Thus,considering the cost-to-effectiveness ratio and the weight of the injector,an external electrode with a larger mesh hole size should be chosen,which contradicts the above rule. 展开更多
关键词 flame stabilization alternating current driven dielectric barrier discharge plasma injector plasma-assisted combustion external electrode
下载PDF
AC operation and runaway electron behaviour in HT-7 tokamak
4
作者 卢洪伟 胡立群 +10 位作者 周瑞杰 林士耀 钟国强 王少锋 陈开云 许平 张继宗 凌必利 毛松涛 段艳敏 HT-7 Team 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第6期375-384,共10页
Operation of HT-7 tokamak in a multicycle alternating square wave plasma current regime is reported. A set of AC operation experiments, including LHW heating to enhance plasma ionization during the current transition ... Operation of HT-7 tokamak in a multicycle alternating square wave plasma current regime is reported. A set of AC operation experiments, including LHW heating to enhance plasma ionization during the current transition and current sustainment, is described. The behaviour of runaway electrons is analysed by four HXR detectors tangentially viewing the plasma in the equatorial plane, within energy ranges 0.3-1.2 MeV and 0.3-7 MeV, separately. High energy runaway electrons (~MeV) axe found to circulate predominantly in the opposite direction to the plasma current, while the number of low energy runaway electrons (~tens to hundreds of keV) circulating along the plasma current is comparable to that in the direction opposite to the plasma current. AC operation with lower hybrid current drive (LHCD) is observed to have an additional benefit of suppressing the runaway electrons if the drop of the loop voltage is large enough. 展开更多
关键词 runaway electron alternating current (AC) discharge lower hybrid current drive loop voltage
下载PDF
Effect of actuating frequency on plasma assisted detonation initiation
5
作者 周思引 车学科 +1 位作者 王迪 聂万胜 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第2期468-475,共8页
Aiming at studying the influence of actuating frequency on plasma assisted detonation initiation by alternating current dielectric barrier discharge, a loosely coupled method is used to simulate the detonation initiat... Aiming at studying the influence of actuating frequency on plasma assisted detonation initiation by alternating current dielectric barrier discharge, a loosely coupled method is used to simulate the detonation initiation process of a hydrogenoxygen mixture in a detonation tube at different actuating frequencies. Both the discharge products and the detonation forming process which is assisted by the plasma are analyzed. It is found that the patterns of the temporal and spatial distributions of discharge products in one cycle are not changed by the actuating frequency. However, the concentration of every species decreases as the actuating frequency rises, and atom O is the most sensitive to this variation, which is related to the decrease of discharge power. With respect to the reaction flow of the detonation tube, the deflagration-todetonation transition(DDT) time and distance both increase as the actuating frequency rises, but the degree of effect on DDT development during flow field evolution is erratic. Generally, the actuating frequency affects none of the amplitude value of the pressure, temperature, species concentration of the flow field, and the combustion degree within the reaction zone. 展开更多
关键词 alternating current dielectric barrier discharge plasma assisted detonation initiation actuating frequency deflagration to detonation active particles
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部