A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic...A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic field through the plasma to directly measure the ratio of the plasma loop average electron density to collision frequency.An equivalent circuit model is used to analyze the relationship of the phase shift of the magnetic field component of LF electromagnetic waves with the plasma electron density and collision frequency.The applicable range of the LF method on a given plasma scale is analyzed.The upper diagnostic limit for the ratio of the electron density(unit:m^(-3))to collision frequency(unit:Hz)exceeds 1×10^(11),enabling an electron density to exceed 1×10^(20)m^(-3)and a collision frequency to be less than 1 GHz.In this work,the feasibility of using the LF phase shift to implement the plasma diagnosis is also assessed.Diagnosis experiments on shock tube equipment are conducted by using both the electrostatic probe method and LF method.By comparing the diagnostic results of the two methods,the inversion results are relatively consistent with each other,thereby preliminarily verifying the feasibility of the LF method.The ratio of the electron density to the collision frequency has a relatively uniform distribution during the plasma stabilization.The LF diagnostic path is a loop around the model,which is suitable for diagnosing the plasma that surrounds the model.Finally,the causes of diagnostic discrepancy between the two methods are analyzed.The proposed method provides a new avenue for diagnosing high-density enveloping plasma.展开更多
Biofouling has been a persistent problem in marine riser system, resulting in energy waste and equipment damage. Inthis study, a kind of water wave-driven contact-mode flexible triboelectric nanogeneration has been pr...Biofouling has been a persistent problem in marine riser system, resulting in energy waste and equipment damage. Inthis study, a kind of water wave-driven contact-mode flexible triboelectric nanogeneration has been prepared byusing graphene-doped PDMS as dielectric friction material. When the graphene content is 2%, the average outputvoltage can reach 46 V under the contact frequency 10 Hz. The flexible triboelectric nanogeneration encapsulationmodule is impinged by water waves to generate alternating microelectric field on the riser surface and destroy theadhesion conditions of microorganisms during the biofilm stage. In the biofouling experiments at different stages, thebiofouling area of the platymonas subcordiformis has been reduced by 53%, 62% and 61%. It provides a new ideafor effective treatment of biofouling of mussels, oysters and barnacles attached to risers.展开更多
The effects of alternating magnetic field on the corrosion morphologies, corrosion rate, and corrosion products of copper in 3.5% NaCl solution, sea water, and magnetized sea water were investigated using electrochemi...The effects of alternating magnetic field on the corrosion morphologies, corrosion rate, and corrosion products of copper in 3.5% NaCl solution, sea water, and magnetized sea water were investigated using electrochemical test, scanning electron microscopy/energy dispersive analysis system of X-ray (SEM/EDAX), and X-ray diffraction (XRD). The results show that the corrosion rate of copper in magnetized sea water is minimal. Moreover, the surface of the specimen in magnetized sea water is uniform and compact as compared with those in 3.5% NaCl solution and sea water. The corrosion products of copper in magnetized sea water are mainly Cu2O and CuCl2. However, the corrosion products in sea water are CuCl, Cu2Cl(OH)3, and FeCl3-6H2O. The electrochemical corrosion mechanisms of copper in the three media were also discussed.展开更多
Magnetotactic bacteria(MTB)intact cells have been applied in magnetic hyperthermia therapy of tumor,showing great efficiency in heating for tumor cell inhibition.However,the detailed magnetic hyperthermia properties a...Magnetotactic bacteria(MTB)intact cells have been applied in magnetic hyperthermia therapy of tumor,showing great efficiency in heating for tumor cell inhibition.However,the detailed magnetic hyperthermia properties and optimum heat production conditions of MTB cells are still poorly understood due to lack of standard measuring equipment.The specific absorption rate(SAR)of MTB cells is often measured by home-made equipment at a limited frequency and magnetic field amplitude.In this study,we have used a commercial standard system to implement a comprehensive study of the hyperthermic response of Magnetospirillum gryphiswaldense MSR-1 strain under 7 frequencies of 144-764 kHz,and 8 field amplitudes between 10 and 45 kA/m.The measurement results prove that the SAR of MTB cells increases with magnetic field frequency and amplitude within a certain range.In combination with the magnetic measurements,it is determined that the magnetic hyperthermia mechanism of MTB mainly follows the principle of hysteresis loss,and the heat efficiency of MTB cells in alternating magnetic field are mainly aff ected by three parameters of hysteresis loop,saturation magnetisation,saturation remanent magnetisation,and coercivity.Thus when we culture MTB in LA-2 medium containing sodium nitrate as source of nitrogen,the SAR of MTB LA-2 cells with magnetosomes arranged in chains can be as high as 4925.6 W/g(in this work,all SARs are calculated with iron mass)under 764 kHz and 30 kA/m,which is 7.5 times than current commercial magnetic particles within similar size range.展开更多
A magnetic abrasive finishing process using an alternating magnetic field is proposed for the finishing of complex surfaces.In an alternating field,the periodic changes in current will cause the magnetic cluster used ...A magnetic abrasive finishing process using an alternating magnetic field is proposed for the finishing of complex surfaces.In an alternating field,the periodic changes in current will cause the magnetic cluster used as a magnetic brush to fluctuate,which will not only continuously replace the abrasive particles in contact with the workpiece,but also periodically adjust the shape of the magnetic cluster to better fit the surface of the workpiece.In this paper,the influence of a combination of alternating and static magnetic fields on the magnetic field in the finishing area is analyzed.The feasibility of this process for finishing micro-grooves is investigated.Simulations and experimental measurements show that the combination of alternating and static magnetic fields can retain the advantages of the alternating field while increasing the magnetic flux density in the finishing area.The experimental results show that the process is feasible for finishing micro-grooves,with an excellent deburring effect on the groove edges.展开更多
We consider the radiation from the beam electrons traveling in a strong uniform axial magnetic field and an axial alternating electric field of wavelength Aw generated by a voltage-supplied pill-box cavity. The beam e...We consider the radiation from the beam electrons traveling in a strong uniform axial magnetic field and an axial alternating electric field of wavelength Aw generated by a voltage-supplied pill-box cavity. The beam electrons emit genuine laser radiation that propagates only in the axial direction through free-electron two- quantum Stark radiation. We find that laser radiation takes place only at the expense of the axial kinetic energy when Aw 〈〈 c/(ωc/γ), where ωc/γ is the relativistic electron--cyclotron frequency. We formulate the laser power based on quantum-wiggler electrodynamics, and envision a laser of length lore with estimated power 0.1 GW/(kA) in the 10-4 cm wavelength range.展开更多
Implant-related osteomyelitis is a formidable hurdle in the clinical setting and is characterized by inflammation,infection,and consequential bone destruction.Therefore,effective reactive oxygen species(ROS)scavenging...Implant-related osteomyelitis is a formidable hurdle in the clinical setting and is characterized by inflammation,infection,and consequential bone destruction.Therefore,effective reactive oxygen species(ROS)scavenging,bacterial killing,and subsequent bone tissue repair are urgently needed for the treatment of difficult-to-heal osteomyelitis.Herein,we utilized the eddy-thermal effect of magnesium(Mg)implants under an alternating magnetic field(AMF)for the controlled release of H_(2)gas and ions(OH^(-)and Mg^(2+))for the treatment of osteomyelitis.H_(2)released by Mg rods under AMFs effectively scavenged cytotoxic ROS,exhibiting anti-inflammatory effects and consequently disrupting the environment of bacterial infections.In addition,the OH-hindered the energy metabolism of bacteria by effectively neutralizing protons within the microenvironment.Moreover,H_(2)impaired the permeability of bacterial membranes and expedited the damage induced by OH-.This synergistic AMF-induced H_(2)and proton depletion treatment approach not only killed both gram-negative and gram-positive bacteria but also effectively treated bacterial infections(abscesses and osteomyelitis).Moreover,Mg^(2+)released from the Mg rods enhanced and accelerated the process of bone osteogenesis.Overall,our work cleverly exploited the eddy-thermal effect and chemical activity of Mg implants under AMFs,aiming to eliminate the inflammatory environment and combat bacterial infections by the simultaneous release of H_(2),OH^(-),and Mg^(2+),thereby facilitating tissue regeneration.This therapeutic strategy achieved multiple benefits in one,thus presenting a promising avenue for clinical application.展开更多
To investigate the effect of alternating magnetic field on austenite transformation process in the case of rapid heating,the austenite kinetics model of AISI 1045 steel was built for spot continual induction hardening...To investigate the effect of alternating magnetic field on austenite transformation process in the case of rapid heating,the austenite kinetics model of AISI 1045 steel was built for spot continual induction hardening(SCIH)process.The results shows that the effect of alternating magnetic field on austenite transformation fraction reaches the maximum(about 3%)when heating rate is the lowest.Relatively low magnetic flux density still has a certain effect on the austenite transformation process during the SCIH process.Concave surface structure can reduce the influence scope of alternating magnetic field on surface in all cases and the minimum influence scope appears when the feed path of inductor is longitudinal.Convex surface structure can minimize the influence scope of alternating magnetic field in depth when the feed path of inductor is longitudinal.The austenite distribution of transitional region on surface for horizontal movement is more uniform than that for longitudinal movement.The austenite distribution of transitional region in depth for longitudinal movement is more uniform than that for horizontal movement.The simulated results are consistent with the experimental results and the austenite transformation kinetics model developed for SCIH process is valid.展开更多
All-position welding is an important technology in energy sources, chemical, shipbuilding and other industries. When welding current is larger than 200 A, the molten metal tends to flow down due to the force of gravit...All-position welding is an important technology in energy sources, chemical, shipbuilding and other industries. When welding current is larger than 200 A, the molten metal tends to flow down due to the force of gravity. In order to "push" the molten metal into the weld, a new kind of U-frame excitation model, which could produce electromagnetic force to balance the gravity of the molten pool, was designed. The related parameters of the excitation model were simulated by Maxwell 3D, and the relationships between the parameters and the magnetic induction intensity were analyzed. Finally, the electromagnetic force in the molten pool was calculated, and the appropriate parameters of the U-frame excitation model were determined. The results of the simulation verify the feasibility of the all-position welding excitation model.展开更多
The influence of an alternative magnetic field on the diffusion of Al and Mg in AI-Mg diffusion couple is studied. The diffusion zone is composed of two intermediate phases, namelyβ and γ phase. Thickness of each in...The influence of an alternative magnetic field on the diffusion of Al and Mg in AI-Mg diffusion couple is studied. The diffusion zone is composed of two intermediate phases, namelyβ and γ phase. Thickness of each intermediate phase is examined. The results show that the alternative magnetic field increases the thicknesses of βand γ phase zone and the layer growth ofβ and γphase obeys the parabolic rate law. The growth rate of the β and γ phase are increased with the application of the alternative magnetic field. This change is manifested through a change in the frequency factor k0 and not through a change in the activation energy Q. The frequency factor k0 for intermediate phase growth with an alternative magnetic field is 39.95 cm2/s for 7 phase and 2.84×10-4 cm2/s for β phase compared with those without the magnetic field is 22.4 cm2/s for 7 phase and 1.53×10-4 cm2/s for β phase.展开更多
The influence of an alternative magnetic field on the growth of the diffusionlayer in Al-Zn diffusion couple was studied. The thickness of the diffusion layer was examined. Theresults show that the alternative magneti...The influence of an alternative magnetic field on the growth of the diffusionlayer in Al-Zn diffusion couple was studied. The thickness of the diffusion layer was examined. Theresults show that the alternative magnetic field increases the thickness of the diffusion layer andthe effect increases with the intensity and frequency of the alternative magnetic field increasing. The growth of the diffusion layer obeys the parabolic rate law and the growth rateincreases with the application of the alternative magnetic field. This growth rate change ismanifested through a change in the frequency factor k_0 and not through a change in the activationenergy Q. The frequency factor k_0 for the diffusion layer growth with the alternative magneticfield is 5.03 cm^2/s and the one without the magnetic field is 3.84 cm^2/s.展开更多
The use of low electrically conducting liquids is more and more widespread.This is the case for molten glass,salt or slag processing,ionic liquids used in biotechnology,batteries in energy storage and metallurgy.The p...The use of low electrically conducting liquids is more and more widespread.This is the case for molten glass,salt or slag processing,ionic liquids used in biotechnology,batteries in energy storage and metallurgy.The present paper deals with the design of a new electromagnetic induction device that can heat and stir low electricallyconducting liquids.It consists of a resistance-capacity-inductance circuit coupled with a low-conducting liquid load.The device is supplied by a unique electric power source delivering a single-phase high frequency electric current.The main working principle of the circuit is based on a double oscillating circuit inductor connected to the solid-state transistor generator.This technique,which yields a set of coupled oscillating circuits,consists of coupling a forced phase and an induced phase,neglecting the influence of the electric parameters of the loading part(i.e.,the low-conductivity liquid).It is shown that such an inductor is capable to provide a two-phase AC traveling magnetic field at high frequency.To better understand the working principle,the present work improves a previous existing simplified theory by taking into account a complex electrical equivalent diagram due to the different mutual couplings between the two inductors and the two corresponding induced current sets.A more detailed theoretical model is provided,and the key and sensitive elements are elaborated.Based on this theory,equipment is designed to provide a stirring effect on sodium chloride-salted water at 40 S/m.It is shown that such a device fed by several hundred kiloHertz electric currents is able to mimic a linear motor.A set of optimized operating parameters are proposed to guide the experiment.A pure electromagnetic numerical model is presented.Numerical modelling of the load is performed in order to assess the efficiency of the stirrer with a salt water load.Such a device can generate a significant liquid motion with both controlled flow patterns and adjustable amplitude.Based on the magnetohydrodynamic theory,numerical modeling of the salt water flow generated by the stirrer confirms its feasibility.展开更多
Plant stress caused by exposure to magnetic fields (MF) induces modifications at molecular level, particularly in DNA synthesis, structure, and function. The objective of this study was to determine the effect of va...Plant stress caused by exposure to magnetic fields (MF) induces modifications at molecular level, particularly in DNA synthesis, structure, and function. The objective of this study was to determine the effect of various doses of non-ionizing radiation of magnetic field on date palm (Phoenix dactylifera L.) based on DNA content. Date palm seedlings (cv. Khalas) established for 2 weeks on filter paper were subjected to static magnetic field and alternating magnetic field. Static magnetic fields (SMF) were applied at 10, 50 and 100 mT for 30, 60, 120, 180, 240 and 360 min; while alternating magnetic field applied by magnetic resonance imaging (MRI) at 1500 mT for 1, 5, 10 and 15 min. The seedlings were grown in potting soil following exposure for 4 weeks after which DNA was extracted from leaves and its content was determined. Generally, the exposure to magnetic field caused reduction in the content of DNA. The lowest exposure time tested, 30 rain, was sufficient to induce reduction in DNA content. This was true even at the lowest intensity, 10 mT. This dosage caused the DNA content to decrease from 49 ~tg/g to 45 pg/g. Further, increase of the exposure duration to 60 min caused significant reduction in the DNA content, 36 μg/g. At intensities higher than 10 mT, DNA content decreased significantly even at the shortest exposure of 30 min. At 50 and 100 mT, significant decrease in DNA content was also noticed in response to 30 min exposure; whereas the level of DNA increased after 1 min of MRI exposure to 52 ~g/g, then decreased after 5 min to 46 ~g/g. However, longer durations caused no further decrease in the DNA content. These observations indicate that magnetic fields interact with DNA processes, probably by inhibiting synthesis or stimulating degradation of DNA. This response merits further exploration as a mutational agent for date palm genetic manipulation.展开更多
Our purpose in this study was to present a method for estimating the specific loss power (SLP) in magnetic hyperthermia in the presence of an external static magnetic field (SMF) and to investigate the SLP values esti...Our purpose in this study was to present a method for estimating the specific loss power (SLP) in magnetic hyperthermia in the presence of an external static magnetic field (SMF) and to investigate the SLP values estimated by this method under various diameters (D) of magnetic nanoparticles (MNPs) and amplitudes (H<sub>0</sub>) and frequencies (f) of an alternating magnetic field (AMF). In our method, the SLP was calculated by solving the magnetization relaxation equation of Shliomis numerically, in which the magnetic field strength at time t (H(t)) was assumed to be given by , with H<sub>s</sub> being the strength of the SMF. We also investigated the SLP values in the case when the SMF with a field-free point (FFP) generated by two solenoid coils was used. The SLP value in the quasi steady state (SLP<sub>qss</sub>) decreased with increasing H<sub>s</sub>. The plot of the SLP<sub>qss</sub> values against the position from the FFP became narrow as the gradient strength of the SMF (G<sub>s</sub>) increased. Conversely, it became broad as G<sub>s</sub> decreased. These results suggest that the temperature rise and the area of local heating in magnetic hyperthermia can be controlled by varying the H<sub>s</sub> and G<sub>s</sub> values, respectively. In conclusion, our method will be useful for estimating the SLP in the presence of both the AMF and SMF and for designing an effective local heating system for magnetic hyperthermia in order to reduce the risk of overheating surrounding healthy tissues.展开更多
Deep oil exploration coring technology cannot accurately maintain the in-situ pressure and temperature of samples, which leads to a distortion of deep oil and gas resource reserve evaluations based on conventional cor...Deep oil exploration coring technology cannot accurately maintain the in-situ pressure and temperature of samples, which leads to a distortion of deep oil and gas resource reserve evaluations based on conventional cores and cannot guide the development of deep oil and gas resources on Earth. The fundamental reason is the lack of temperature and pressure control in in-situ coring environments. In this paper, a pressure control method of a coring device is studied. The theory and method of deep intelligent temperature-pressure coupling control are innovatively proposed, and a multifield coupling dynamic sealing model is established. The optimal cardinality three term PID (Proportional-Integral-Differential) intelligent control algorithm of pressure system is developed. The temperature-pressure characteristic of the gas-liquid two-phase cavity is analyzed, and the pressure intelligent control is carried out based on three term PID control algorithms. An in-situ condition-preserved coring (ICP-Coring) device is developed, and an intelligent control system for the temperature and pressure of the coring device is designed and verified by experiments. The results show that the temperature-pressure coupling control system can effectively realize stable sealing under temperature-pressure fields of 140 MPa and 150 °C. The temperature-pressure coupling control method can accurately realize a constant pressure inside the coring device. The maximum working pressure is 140 MPa, and the effective pressure compensation range is 20 MPa. The numerical simulation experiment of pressure system control algorithm is carried out, and the optimal cardinality and three term coefficients are obtained. The pressure steady-state error is less than 0.01%. The method of temperature-pressure coupling control has guiding significance for coring device research, and is also the basis for temperature-pressure decoupling control in ICP-Coring.展开更多
To improve the electrorheological effect of electrorheological fluid (ERF), a new type of the electrosensitive particle material, polynaphthalene quinone was prepared, whose molecules contain blended atoms of nitrogen...To improve the electrorheological effect of electrorheological fluid (ERF), a new type of the electrosensitive particle material, polynaphthalene quinone was prepared, whose molecules contain blended atoms of nitrogen, oxygen, sulphur and big π bond conjugate system. In both DC and AC electric fields, the ERF material showed a distinct ER effect. Especially, in the alternating electric field, the shear stress of this material versus AC voltage has a better quadratic relation than that of the other materials. The experimental data showed that organic semiconductor polymers with big π bond conjugate system are a new type of electrosensitive particle materials which are worth well developing.展开更多
In older to collect fine particles more efficiently, a new-type electrostatic agglomerator with two zones was developed. The distinguishing feature of this electrostatic agglomerator is that the particles are bipolarl...In older to collect fine particles more efficiently, a new-type electrostatic agglomerator with two zones was developed. The distinguishing feature of this electrostatic agglomerator is that the particles are bipolarly charged and coagulated in the same alternating electric field simultaneously. The silica flour with 2 fun mass median diameter and the smoke from burning wood powder were used as test aerosol. The comparison experimental results have shown that when the mean electric field is 4 kV/cm the collection efficiency of the new electrostatic agglomerator was 98.2% for silica flour and 67.4% for wood powder smoke, Under the same experimental condition. the collection efficiency of the electrostatic agglomerator with three zones was 97.4% for collecting silica flour and the collection efficiency of the electrostatic precipitator was 56.3% for wood powder smoke.展开更多
The conversion of electromagnetic energy into heat by nanomagnets has the potential to be a powerful, non-invasive technique for cancer therapy by hyperthermia and hyperthermia-based drug release, while temperature co...The conversion of electromagnetic energy into heat by nanomagnets has the potential to be a powerful, non-invasive technique for cancer therapy by hyperthermia and hyperthermia-based drug release, while temperature controllability and targeted heating are challenges to developing applications of such magnetic inductive hyperthermia. This study was designed to control the hyperthermia position and area using a combination of alternating current (AC) and a static magnetic field. MnZn ferrite (MZF) nanoparticles which exhibited excellent hyperthermia properties were first prepared and characterized as an inductive heating mediator. We built model static magnetic fields simply using a pair of permanent magnets and studied the static magnetic field distributions by measurements and numerical simulations. The influence of the transverse static magnetic fields on hyperthermia properties was then investigated on MZF magnetic fluid, gel phantoms and SMMC-7721 cells in vitro. The results showed a static magnetic field can inhibit the temperature rise of MZF nanoparticles in an AC magnetic field. But in the uneven static magnetic field formed by a magnet pair with repelling poles face-to-face, the heating area can be restricted in a central low static field; meanwhile the side effects of hyperthermia can be reduced by a surrounding high static field. As a result we can position the hyperthermia area, protect the non-therapeutic area, and reduce the side effects lust by using a well-designed combination of AC and static field.展开更多
Herein, a hot tearing measured system with external excitation coil and a differential thermal analysis system with applied magnetic field were used to study the effects of low-frequency alternating magnetic field on ...Herein, a hot tearing measured system with external excitation coil and a differential thermal analysis system with applied magnetic field were used to study the effects of low-frequency alternating magnetic field on the solidification behavior and hot tearing susceptibility(HTS) of the AXJ530 alloy under different magnetic field parameters. The hot tearing volume of the castings was measured via paraffin infiltration method. The microstructure of the hot tearing zone of the casting was observed using optical microscopy and scanning electron microscopy, and the phase composition was analyzed using X-ray diffraction and energy depressive spectroscopy. The experimental results show that the solidification interval of AXJ530 alloy was shortened and the dendrite coherency temperature of the alloy decreased with the increase in frequency of alternating magnetic field. Under appropriate magnetic field parameters, the electromagnetic force could enhance the convection in the melt to promote the flow of the residual liquid phase, refine the microstructure, and optimize the feeding channel in the late solidification stage, which reduced the HTS of the alloy. However, when the magnetic field frequency was increased to 15 Hz, the induced current generated excessive Joule heat to the melt. At this time, the thermal action of the magnetic field coarsened the microstructure of the alloy, resulting in an increase in HTS of the alloy.展开更多
Research progress and frontiers of magnetic-mediated hyperthermia (MMH) are presented, along with clinical trials in Germany, the US, Japan, and China. Special attention is focused on MMH mediated by magnetic nanopa...Research progress and frontiers of magnetic-mediated hyperthermia (MMH) are presented, along with clinical trials in Germany, the US, Japan, and China. Special attention is focused on MMH mediated by magnetic nanoparticles, and multifunctional magnetic devices for cancer multimodality treatment are also introduced.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.52107162 and 12202479)the Science and Technology Projects of Shaanxi Province,China(Grant Nos.2022CGBX-12 and 2022KXJ-57)the Science and Technology Projects of Xi’an City,China(Grant Nos.23KGDW0023-2022 and 23GXFW0011)。
文摘A non-contact low-frequency(LF)method of diagnosing the plasma surrounding a scaled model in a shock tube is proposed.This method utilizes the phase shift occurring after the transmission of an LF alternating magnetic field through the plasma to directly measure the ratio of the plasma loop average electron density to collision frequency.An equivalent circuit model is used to analyze the relationship of the phase shift of the magnetic field component of LF electromagnetic waves with the plasma electron density and collision frequency.The applicable range of the LF method on a given plasma scale is analyzed.The upper diagnostic limit for the ratio of the electron density(unit:m^(-3))to collision frequency(unit:Hz)exceeds 1×10^(11),enabling an electron density to exceed 1×10^(20)m^(-3)and a collision frequency to be less than 1 GHz.In this work,the feasibility of using the LF phase shift to implement the plasma diagnosis is also assessed.Diagnosis experiments on shock tube equipment are conducted by using both the electrostatic probe method and LF method.By comparing the diagnostic results of the two methods,the inversion results are relatively consistent with each other,thereby preliminarily verifying the feasibility of the LF method.The ratio of the electron density to the collision frequency has a relatively uniform distribution during the plasma stabilization.The LF diagnostic path is a loop around the model,which is suitable for diagnosing the plasma that surrounds the model.Finally,the causes of diagnostic discrepancy between the two methods are analyzed.The proposed method provides a new avenue for diagnosing high-density enveloping plasma.
基金supported by the National Key Research and Development Program of China(Grant No.2021YFB3401400)。
文摘Biofouling has been a persistent problem in marine riser system, resulting in energy waste and equipment damage. Inthis study, a kind of water wave-driven contact-mode flexible triboelectric nanogeneration has been prepared byusing graphene-doped PDMS as dielectric friction material. When the graphene content is 2%, the average outputvoltage can reach 46 V under the contact frequency 10 Hz. The flexible triboelectric nanogeneration encapsulationmodule is impinged by water waves to generate alternating microelectric field on the riser surface and destroy theadhesion conditions of microorganisms during the biofilm stage. In the biofouling experiments at different stages, thebiofouling area of the platymonas subcordiformis has been reduced by 53%, 62% and 61%. It provides a new ideafor effective treatment of biofouling of mussels, oysters and barnacles attached to risers.
文摘The effects of alternating magnetic field on the corrosion morphologies, corrosion rate, and corrosion products of copper in 3.5% NaCl solution, sea water, and magnetized sea water were investigated using electrochemical test, scanning electron microscopy/energy dispersive analysis system of X-ray (SEM/EDAX), and X-ray diffraction (XRD). The results show that the corrosion rate of copper in magnetized sea water is minimal. Moreover, the surface of the specimen in magnetized sea water is uniform and compact as compared with those in 3.5% NaCl solution and sea water. The corrosion products of copper in magnetized sea water are mainly Cu2O and CuCl2. However, the corrosion products in sea water are CuCl, Cu2Cl(OH)3, and FeCl3-6H2O. The electrochemical corrosion mechanisms of copper in the three media were also discussed.
基金Supported by the Strategic Priority Research Program of Chinese Academy of Sciences(No.XDB41010403)the National Natural Science Foundation of China(Nos.41804070,41774076,41621004)+2 种基金the Key Program of Chinese Academy of Sciences(No.QYZDJ-SSWDQC024)the Key Research Program of the Institute of Geology and Geophysics,CAS(No.IGGCAS-201903)the PetroChina Innovation Foundation(No.2020D-5007-0105)。
文摘Magnetotactic bacteria(MTB)intact cells have been applied in magnetic hyperthermia therapy of tumor,showing great efficiency in heating for tumor cell inhibition.However,the detailed magnetic hyperthermia properties and optimum heat production conditions of MTB cells are still poorly understood due to lack of standard measuring equipment.The specific absorption rate(SAR)of MTB cells is often measured by home-made equipment at a limited frequency and magnetic field amplitude.In this study,we have used a commercial standard system to implement a comprehensive study of the hyperthermic response of Magnetospirillum gryphiswaldense MSR-1 strain under 7 frequencies of 144-764 kHz,and 8 field amplitudes between 10 and 45 kA/m.The measurement results prove that the SAR of MTB cells increases with magnetic field frequency and amplitude within a certain range.In combination with the magnetic measurements,it is determined that the magnetic hyperthermia mechanism of MTB mainly follows the principle of hysteresis loss,and the heat efficiency of MTB cells in alternating magnetic field are mainly aff ected by three parameters of hysteresis loop,saturation magnetisation,saturation remanent magnetisation,and coercivity.Thus when we culture MTB in LA-2 medium containing sodium nitrate as source of nitrogen,the SAR of MTB LA-2 cells with magnetosomes arranged in chains can be as high as 4925.6 W/g(in this work,all SARs are calculated with iron mass)under 764 kHz and 30 kA/m,which is 7.5 times than current commercial magnetic particles within similar size range.
文摘A magnetic abrasive finishing process using an alternating magnetic field is proposed for the finishing of complex surfaces.In an alternating field,the periodic changes in current will cause the magnetic cluster used as a magnetic brush to fluctuate,which will not only continuously replace the abrasive particles in contact with the workpiece,but also periodically adjust the shape of the magnetic cluster to better fit the surface of the workpiece.In this paper,the influence of a combination of alternating and static magnetic fields on the magnetic field in the finishing area is analyzed.The feasibility of this process for finishing micro-grooves is investigated.Simulations and experimental measurements show that the combination of alternating and static magnetic fields can retain the advantages of the alternating field while increasing the magnetic flux density in the finishing area.The experimental results show that the process is feasible for finishing micro-grooves,with an excellent deburring effect on the groove edges.
文摘We consider the radiation from the beam electrons traveling in a strong uniform axial magnetic field and an axial alternating electric field of wavelength Aw generated by a voltage-supplied pill-box cavity. The beam electrons emit genuine laser radiation that propagates only in the axial direction through free-electron two- quantum Stark radiation. We find that laser radiation takes place only at the expense of the axial kinetic energy when Aw 〈〈 c/(ωc/γ), where ωc/γ is the relativistic electron--cyclotron frequency. We formulate the laser power based on quantum-wiggler electrodynamics, and envision a laser of length lore with estimated power 0.1 GW/(kA) in the 10-4 cm wavelength range.
基金supported by the National Key Research and Development Program of China(2022YFB3804600,2021YFF0701800)the National Natural Science Foundation of China(U20A20254,52072253)+4 种基金the Science and Technology Development Fund,Macao SAR(0118/2023/RIA2)Collaborative Innovation Center of Suzhou Nano Science and Technology,Suzhou Key Laboratory of Nanotechnology and Biomedicine,the Jiangsu Natural Science Fund for Distinguished Young Scholars(BK20211544)the 111 Project,Joint International Research Laboratory of Carbon-Based Functional Materials and Devices,Medical Research Project of Jiangsu Province(ZD2022024)New Cornerstone Science Foundation through the XPLORER PRIZE,and Key Laboratory of Structural Deformities in Children of Suzhou(SZS2022018)N.Y.was supported by the Macao Young Scholars Program and the Jiangsu Funding Program for Excellent Postdoctoral Talent.
文摘Implant-related osteomyelitis is a formidable hurdle in the clinical setting and is characterized by inflammation,infection,and consequential bone destruction.Therefore,effective reactive oxygen species(ROS)scavenging,bacterial killing,and subsequent bone tissue repair are urgently needed for the treatment of difficult-to-heal osteomyelitis.Herein,we utilized the eddy-thermal effect of magnesium(Mg)implants under an alternating magnetic field(AMF)for the controlled release of H_(2)gas and ions(OH^(-)and Mg^(2+))for the treatment of osteomyelitis.H_(2)released by Mg rods under AMFs effectively scavenged cytotoxic ROS,exhibiting anti-inflammatory effects and consequently disrupting the environment of bacterial infections.In addition,the OH-hindered the energy metabolism of bacteria by effectively neutralizing protons within the microenvironment.Moreover,H_(2)impaired the permeability of bacterial membranes and expedited the damage induced by OH-.This synergistic AMF-induced H_(2)and proton depletion treatment approach not only killed both gram-negative and gram-positive bacteria but also effectively treated bacterial infections(abscesses and osteomyelitis).Moreover,Mg^(2+)released from the Mg rods enhanced and accelerated the process of bone osteogenesis.Overall,our work cleverly exploited the eddy-thermal effect and chemical activity of Mg implants under AMFs,aiming to eliminate the inflammatory environment and combat bacterial infections by the simultaneous release of H_(2),OH^(-),and Mg^(2+),thereby facilitating tissue regeneration.This therapeutic strategy achieved multiple benefits in one,thus presenting a promising avenue for clinical application.
基金Projects(51905390,51575415)supported by the National Natural Science Foundation of China。
文摘To investigate the effect of alternating magnetic field on austenite transformation process in the case of rapid heating,the austenite kinetics model of AISI 1045 steel was built for spot continual induction hardening(SCIH)process.The results shows that the effect of alternating magnetic field on austenite transformation fraction reaches the maximum(about 3%)when heating rate is the lowest.Relatively low magnetic flux density still has a certain effect on the austenite transformation process during the SCIH process.Concave surface structure can reduce the influence scope of alternating magnetic field on surface in all cases and the minimum influence scope appears when the feed path of inductor is longitudinal.Convex surface structure can minimize the influence scope of alternating magnetic field in depth when the feed path of inductor is longitudinal.The austenite distribution of transitional region on surface for horizontal movement is more uniform than that for longitudinal movement.The austenite distribution of transitional region in depth for longitudinal movement is more uniform than that for horizontal movement.The simulated results are consistent with the experimental results and the austenite transformation kinetics model developed for SCIH process is valid.
基金This work was supported by the National Natural Science Foundation of China (No. 51075299).
文摘All-position welding is an important technology in energy sources, chemical, shipbuilding and other industries. When welding current is larger than 200 A, the molten metal tends to flow down due to the force of gravity. In order to "push" the molten metal into the weld, a new kind of U-frame excitation model, which could produce electromagnetic force to balance the gravity of the molten pool, was designed. The related parameters of the excitation model were simulated by Maxwell 3D, and the relationships between the parameters and the magnetic induction intensity were analyzed. Finally, the electromagnetic force in the molten pool was calculated, and the appropriate parameters of the U-frame excitation model were determined. The results of the simulation verify the feasibility of the all-position welding excitation model.
文摘The influence of an alternative magnetic field on the diffusion of Al and Mg in AI-Mg diffusion couple is studied. The diffusion zone is composed of two intermediate phases, namelyβ and γ phase. Thickness of each intermediate phase is examined. The results show that the alternative magnetic field increases the thicknesses of βand γ phase zone and the layer growth ofβ and γphase obeys the parabolic rate law. The growth rate of the β and γ phase are increased with the application of the alternative magnetic field. This change is manifested through a change in the frequency factor k0 and not through a change in the activation energy Q. The frequency factor k0 for intermediate phase growth with an alternative magnetic field is 39.95 cm2/s for 7 phase and 2.84×10-4 cm2/s for β phase compared with those without the magnetic field is 22.4 cm2/s for 7 phase and 1.53×10-4 cm2/s for β phase.
基金This work was financially supported by the National 863 Foundation of China (No. 2001AA332030)the National Key Basic Research Program (973) (No. G1999064905)
文摘The influence of an alternative magnetic field on the growth of the diffusionlayer in Al-Zn diffusion couple was studied. The thickness of the diffusion layer was examined. Theresults show that the alternative magnetic field increases the thickness of the diffusion layer andthe effect increases with the intensity and frequency of the alternative magnetic field increasing. The growth of the diffusion layer obeys the parabolic rate law and the growth rateincreases with the application of the alternative magnetic field. This growth rate change ismanifested through a change in the frequency factor k_0 and not through a change in the activationenergy Q. The frequency factor k_0 for the diffusion layer growth with the alternative magneticfield is 5.03 cm^2/s and the one without the magnetic field is 3.84 cm^2/s.
基金This study was supported by the Instrument and Equipment Development Project of the Chinese Academy of Sciences(YJKYYQ20200053)the“Double First-Class”Construction Fund(111800XX62)the Mechanical Engineering Discipline Construction Fund(111800M000).
文摘The use of low electrically conducting liquids is more and more widespread.This is the case for molten glass,salt or slag processing,ionic liquids used in biotechnology,batteries in energy storage and metallurgy.The present paper deals with the design of a new electromagnetic induction device that can heat and stir low electricallyconducting liquids.It consists of a resistance-capacity-inductance circuit coupled with a low-conducting liquid load.The device is supplied by a unique electric power source delivering a single-phase high frequency electric current.The main working principle of the circuit is based on a double oscillating circuit inductor connected to the solid-state transistor generator.This technique,which yields a set of coupled oscillating circuits,consists of coupling a forced phase and an induced phase,neglecting the influence of the electric parameters of the loading part(i.e.,the low-conductivity liquid).It is shown that such an inductor is capable to provide a two-phase AC traveling magnetic field at high frequency.To better understand the working principle,the present work improves a previous existing simplified theory by taking into account a complex electrical equivalent diagram due to the different mutual couplings between the two inductors and the two corresponding induced current sets.A more detailed theoretical model is provided,and the key and sensitive elements are elaborated.Based on this theory,equipment is designed to provide a stirring effect on sodium chloride-salted water at 40 S/m.It is shown that such a device fed by several hundred kiloHertz electric currents is able to mimic a linear motor.A set of optimized operating parameters are proposed to guide the experiment.A pure electromagnetic numerical model is presented.Numerical modelling of the load is performed in order to assess the efficiency of the stirrer with a salt water load.Such a device can generate a significant liquid motion with both controlled flow patterns and adjustable amplitude.Based on the magnetohydrodynamic theory,numerical modeling of the salt water flow generated by the stirrer confirms its feasibility.
文摘Plant stress caused by exposure to magnetic fields (MF) induces modifications at molecular level, particularly in DNA synthesis, structure, and function. The objective of this study was to determine the effect of various doses of non-ionizing radiation of magnetic field on date palm (Phoenix dactylifera L.) based on DNA content. Date palm seedlings (cv. Khalas) established for 2 weeks on filter paper were subjected to static magnetic field and alternating magnetic field. Static magnetic fields (SMF) were applied at 10, 50 and 100 mT for 30, 60, 120, 180, 240 and 360 min; while alternating magnetic field applied by magnetic resonance imaging (MRI) at 1500 mT for 1, 5, 10 and 15 min. The seedlings were grown in potting soil following exposure for 4 weeks after which DNA was extracted from leaves and its content was determined. Generally, the exposure to magnetic field caused reduction in the content of DNA. The lowest exposure time tested, 30 rain, was sufficient to induce reduction in DNA content. This was true even at the lowest intensity, 10 mT. This dosage caused the DNA content to decrease from 49 ~tg/g to 45 pg/g. Further, increase of the exposure duration to 60 min caused significant reduction in the DNA content, 36 μg/g. At intensities higher than 10 mT, DNA content decreased significantly even at the shortest exposure of 30 min. At 50 and 100 mT, significant decrease in DNA content was also noticed in response to 30 min exposure; whereas the level of DNA increased after 1 min of MRI exposure to 52 ~g/g, then decreased after 5 min to 46 ~g/g. However, longer durations caused no further decrease in the DNA content. These observations indicate that magnetic fields interact with DNA processes, probably by inhibiting synthesis or stimulating degradation of DNA. This response merits further exploration as a mutational agent for date palm genetic manipulation.
文摘Our purpose in this study was to present a method for estimating the specific loss power (SLP) in magnetic hyperthermia in the presence of an external static magnetic field (SMF) and to investigate the SLP values estimated by this method under various diameters (D) of magnetic nanoparticles (MNPs) and amplitudes (H<sub>0</sub>) and frequencies (f) of an alternating magnetic field (AMF). In our method, the SLP was calculated by solving the magnetization relaxation equation of Shliomis numerically, in which the magnetic field strength at time t (H(t)) was assumed to be given by , with H<sub>s</sub> being the strength of the SMF. We also investigated the SLP values in the case when the SMF with a field-free point (FFP) generated by two solenoid coils was used. The SLP value in the quasi steady state (SLP<sub>qss</sub>) decreased with increasing H<sub>s</sub>. The plot of the SLP<sub>qss</sub> values against the position from the FFP became narrow as the gradient strength of the SMF (G<sub>s</sub>) increased. Conversely, it became broad as G<sub>s</sub> decreased. These results suggest that the temperature rise and the area of local heating in magnetic hyperthermia can be controlled by varying the H<sub>s</sub> and G<sub>s</sub> values, respectively. In conclusion, our method will be useful for estimating the SLP in the presence of both the AMF and SMF and for designing an effective local heating system for magnetic hyperthermia in order to reduce the risk of overheating surrounding healthy tissues.
基金supported by the National Natural Science Foundation of China(grant numbers 51827901,51805340)funded by the Program for Guangdong Introducing Innovative and Enterpreneurial Teams(No.2019ZT08G315)Shenzhen Basic Research Program(General Program)(No.JCYJ20190808153416970).
文摘Deep oil exploration coring technology cannot accurately maintain the in-situ pressure and temperature of samples, which leads to a distortion of deep oil and gas resource reserve evaluations based on conventional cores and cannot guide the development of deep oil and gas resources on Earth. The fundamental reason is the lack of temperature and pressure control in in-situ coring environments. In this paper, a pressure control method of a coring device is studied. The theory and method of deep intelligent temperature-pressure coupling control are innovatively proposed, and a multifield coupling dynamic sealing model is established. The optimal cardinality three term PID (Proportional-Integral-Differential) intelligent control algorithm of pressure system is developed. The temperature-pressure characteristic of the gas-liquid two-phase cavity is analyzed, and the pressure intelligent control is carried out based on three term PID control algorithms. An in-situ condition-preserved coring (ICP-Coring) device is developed, and an intelligent control system for the temperature and pressure of the coring device is designed and verified by experiments. The results show that the temperature-pressure coupling control system can effectively realize stable sealing under temperature-pressure fields of 140 MPa and 150 °C. The temperature-pressure coupling control method can accurately realize a constant pressure inside the coring device. The maximum working pressure is 140 MPa, and the effective pressure compensation range is 20 MPa. The numerical simulation experiment of pressure system control algorithm is carried out, and the optimal cardinality and three term coefficients are obtained. The pressure steady-state error is less than 0.01%. The method of temperature-pressure coupling control has guiding significance for coring device research, and is also the basis for temperature-pressure decoupling control in ICP-Coring.
文摘To improve the electrorheological effect of electrorheological fluid (ERF), a new type of the electrosensitive particle material, polynaphthalene quinone was prepared, whose molecules contain blended atoms of nitrogen, oxygen, sulphur and big π bond conjugate system. In both DC and AC electric fields, the ERF material showed a distinct ER effect. Especially, in the alternating electric field, the shear stress of this material versus AC voltage has a better quadratic relation than that of the other materials. The experimental data showed that organic semiconductor polymers with big π bond conjugate system are a new type of electrosensitive particle materials which are worth well developing.
文摘In older to collect fine particles more efficiently, a new-type electrostatic agglomerator with two zones was developed. The distinguishing feature of this electrostatic agglomerator is that the particles are bipolarly charged and coagulated in the same alternating electric field simultaneously. The silica flour with 2 fun mass median diameter and the smoke from burning wood powder were used as test aerosol. The comparison experimental results have shown that when the mean electric field is 4 kV/cm the collection efficiency of the new electrostatic agglomerator was 98.2% for silica flour and 67.4% for wood powder smoke, Under the same experimental condition. the collection efficiency of the electrostatic agglomerator with three zones was 97.4% for collecting silica flour and the collection efficiency of the electrostatic precipitator was 56.3% for wood powder smoke.
文摘The conversion of electromagnetic energy into heat by nanomagnets has the potential to be a powerful, non-invasive technique for cancer therapy by hyperthermia and hyperthermia-based drug release, while temperature controllability and targeted heating are challenges to developing applications of such magnetic inductive hyperthermia. This study was designed to control the hyperthermia position and area using a combination of alternating current (AC) and a static magnetic field. MnZn ferrite (MZF) nanoparticles which exhibited excellent hyperthermia properties were first prepared and characterized as an inductive heating mediator. We built model static magnetic fields simply using a pair of permanent magnets and studied the static magnetic field distributions by measurements and numerical simulations. The influence of the transverse static magnetic fields on hyperthermia properties was then investigated on MZF magnetic fluid, gel phantoms and SMMC-7721 cells in vitro. The results showed a static magnetic field can inhibit the temperature rise of MZF nanoparticles in an AC magnetic field. But in the uneven static magnetic field formed by a magnet pair with repelling poles face-to-face, the heating area can be restricted in a central low static field; meanwhile the side effects of hyperthermia can be reduced by a surrounding high static field. As a result we can position the hyperthermia area, protect the non-therapeutic area, and reduce the side effects lust by using a well-designed combination of AC and static field.
基金the LiaoNing Revitalization Talents Program(No.XLYC1807021)the Innovation Talent Program in Sciences and Technologies for Young and Middle-aged Scientists of Shenyang(No.RC180111)the Doctoral Scientific Research Foundation of Liaoning Province(No.51504153)。
文摘Herein, a hot tearing measured system with external excitation coil and a differential thermal analysis system with applied magnetic field were used to study the effects of low-frequency alternating magnetic field on the solidification behavior and hot tearing susceptibility(HTS) of the AXJ530 alloy under different magnetic field parameters. The hot tearing volume of the castings was measured via paraffin infiltration method. The microstructure of the hot tearing zone of the casting was observed using optical microscopy and scanning electron microscopy, and the phase composition was analyzed using X-ray diffraction and energy depressive spectroscopy. The experimental results show that the solidification interval of AXJ530 alloy was shortened and the dendrite coherency temperature of the alloy decreased with the increase in frequency of alternating magnetic field. Under appropriate magnetic field parameters, the electromagnetic force could enhance the convection in the melt to promote the flow of the residual liquid phase, refine the microstructure, and optimize the feeding channel in the late solidification stage, which reduced the HTS of the alloy. However, when the magnetic field frequency was increased to 15 Hz, the induced current generated excessive Joule heat to the melt. At this time, the thermal action of the magnetic field coarsened the microstructure of the alloy, resulting in an increase in HTS of the alloy.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.81172182,81172120,and 81041040)the 7th Singapore–China Cooperative Research Project Call between Agency of Science,Technology and Research(A*STAR)+1 种基金Singapore and the Ministry of Science and Technology(MOST),China(Grant No.20113010006)the National Key Technology Support Program(Grant No.2012857818)
文摘Research progress and frontiers of magnetic-mediated hyperthermia (MMH) are presented, along with clinical trials in Germany, the US, Japan, and China. Special attention is focused on MMH mediated by magnetic nanoparticles, and multifunctional magnetic devices for cancer multimodality treatment are also introduced.