A new water-cooling Gardon-type heat power measuring apparatus is designed to meet the need of heat power source management and distribution. The steady state measurement mathe- matic model of the apparatus is built u...A new water-cooling Gardon-type heat power measuring apparatus is designed to meet the need of heat power source management and distribution. The steady state measurement mathe- matic model of the apparatus is built up in theory and the system amplification coefficient is defined as the ratio of the heat power to the temperature difference of the device, with which the value of the measured source power can be calculated easily with the corresponding temperature difference. In order to obtain an optimal heat power measuring system, the coefficients that can influence the relationship between the amplification coefficient, the temperature difference, and the heat power are analyzed. On the basis of these analyses, a set of experimental device is constructed and a num- ber of experiments are carried on. Compared with the input heat power sample data, the error of the experimental measuring results is less than 4-2%, and the experimental measuring values are in good agreement with the calculated theoretical ones. The heat power measuring apparatus can be applied in heat flux or heat power measurement in other fields due to its simple structure and high accuracy.展开更多
All-vertical-piled wharf is a kind of high-piled wharf, but it is extremely different from the traditional ones in some aspects, such as the structural property, bearing characteristics, failure mechanism, and static ...All-vertical-piled wharf is a kind of high-piled wharf, but it is extremely different from the traditional ones in some aspects, such as the structural property, bearing characteristics, failure mechanism, and static or dynamic calculation methods. In this paper, the finite element method (FEM) and theoretical analysis method are combined to analyze the structural property, bearing behavior and failure mode of the all-vertical-piled wharf in offshore deep water, and to establish simplified calculation methods determining the horizontal static ultimate bearing capacity and the dynamic response for the all-vertical-piled wharf. Firstly, the bearing capability and failure mechanism for all-vertical-piled wharf are studied by use of FEM, and the failure criterion is put forward for all-vertical-piled wharf based on the 'plastic hinge'. According to the failure criterion and P-Y curve method, the simplified calculation method of the horizontal static ultimate bearing capacity for all-vertical-piled wharf is proposed, and it is verified that the simplified method is reasonable by comparison with the FEM. Secondly, the displacement dynamic magnification factor for the all-vertical-piled wharf under wave cyclic loads and ship impact loads is calculated by the FEM and the theory formula based on the single degree of freedom (SDOF) system. The results obtained by the two methods are in good agreement with each other, and the simplified calculation method of the displacement dynamic magnification factor for all-vertical-piled wharf under dynamic loads is proposed. Then the simplified calculation method determining the dynamic response for the all-vertical-piled wharf is proposed in combination with P-Y curve method. That is, the dynamic response of the structure can be obtained through the static calculation results of P-Y curve method multiplied by the displacement dynamic magnification factor. The feasibility of the simplified dynamic response method is verified by comparison with the FEM under different conditions.展开更多
The"5.12"Wenchuan earthquake in 2008 triggered a large number of co-seismic landslides.The rear boundary or cracks of co-seismic landslide are generally located at the steep free surface of thin or thick mou...The"5.12"Wenchuan earthquake in 2008 triggered a large number of co-seismic landslides.The rear boundary or cracks of co-seismic landslide are generally located at the steep free surface of thin or thick mountains.Dynamic process of this kind of landslides could be divided into two parts:the seismic dynamic response of the slope and the movement process of rock mass.Taking the Laoyingyan rockslide as an example,the amplification effect was studied by single-degree-of-freedom system analysis method.Besides,the dynamic process of landslide under seismic loading was simulated by the finite difference method(FDM)and discrete element method(DEM).The amplification coefficient of the rockslide to seismic wave is 1.25.The results show that the critical sliding surface of the Laoyingyan rockslide was formed at the 23 th seconds under the action of seismic wave.At the same time,tension failure occurred at the rear edge of the sliding mass and shear failure occurred at the front edge.The maximum displacement was 0.81 m and the initial velocity was 2.78 m/s.During the initiation process of the rockslide,the rock mass firstly broke down along the joints which are along the dip of the rock stratum,and then collapsed bodily along the secondary structural planes.In the process of movement,the maximum velocity of rock mass was 38.24 m/s.After that,the rock mass underwent multiple collisions,including contact,deceleration to 0 and speed recovery after rebound.Finally,due to the constant loss of energy,the rocks stopped and accumulated loosely at the foot of the slope.The longest distance of movement was about 494 m.Besides,the smaller the damping ratio,the farther the rock mass moved.Compared with the results without considering the amplification factor,the movement distance of landslide by considering the amplification factor was more accurate.The study of the Laoyingyan rockslide is helpful to strengthen our field identification of potential co-seismic rockslides.At the same time,understanding its movement and accumulation process can help us better predict the hazard scope of the co-seismic rockslides,and provide a reference for the design of treatment projects.展开更多
As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields ...As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields under the normal wind and typhoon are simulated by active wind tunnel technology,and rigid-pressure-measurement model and aero-elastic-vibration-measurement model of a large cooling tower are built.The stagnation point,peak suction point,separation point and leeward point of the throat position shell are selected to analyze pressure coefficient,probability distribution,peak factor,power spectral density and dynamic amplification factor under normal wind and typhoon.It is clarified that there exists a significant non-Gaussian characteristic under typhoon condition,which also exists in structural response level.Resonance response ratio of the total response is higher during typhoon condition.The maximum value of dynamic amplification coefficient under typhoon field is up to 1.18 times over that under normal wind.The findings of this study are expected to be of interest and practical use to professional and researchers involved in the wind-resistant designs of super-large cooling towers in typhoon prone regions.展开更多
基金partly supported by the National Basic Research Program of China (2014CB046403)
文摘A new water-cooling Gardon-type heat power measuring apparatus is designed to meet the need of heat power source management and distribution. The steady state measurement mathe- matic model of the apparatus is built up in theory and the system amplification coefficient is defined as the ratio of the heat power to the temperature difference of the device, with which the value of the measured source power can be calculated easily with the corresponding temperature difference. In order to obtain an optimal heat power measuring system, the coefficients that can influence the relationship between the amplification coefficient, the temperature difference, and the heat power are analyzed. On the basis of these analyses, a set of experimental device is constructed and a num- ber of experiments are carried on. Compared with the input heat power sample data, the error of the experimental measuring results is less than 4-2%, and the experimental measuring values are in good agreement with the calculated theoretical ones. The heat power measuring apparatus can be applied in heat flux or heat power measurement in other fields due to its simple structure and high accuracy.
基金financially supported by the Education Commission Fund of Chongqing(Grant No.KJ1500518)the Science Commission Fund of Chongqing(Grant No.cstc2016jcyjA0123)the Open Fund of Key Laboratory of Regulation Technology for Inland Waterway in Transportation Industry of Chongqing Jiaotong University(Grant No.NHHD-201506)
文摘All-vertical-piled wharf is a kind of high-piled wharf, but it is extremely different from the traditional ones in some aspects, such as the structural property, bearing characteristics, failure mechanism, and static or dynamic calculation methods. In this paper, the finite element method (FEM) and theoretical analysis method are combined to analyze the structural property, bearing behavior and failure mode of the all-vertical-piled wharf in offshore deep water, and to establish simplified calculation methods determining the horizontal static ultimate bearing capacity and the dynamic response for the all-vertical-piled wharf. Firstly, the bearing capability and failure mechanism for all-vertical-piled wharf are studied by use of FEM, and the failure criterion is put forward for all-vertical-piled wharf based on the 'plastic hinge'. According to the failure criterion and P-Y curve method, the simplified calculation method of the horizontal static ultimate bearing capacity for all-vertical-piled wharf is proposed, and it is verified that the simplified method is reasonable by comparison with the FEM. Secondly, the displacement dynamic magnification factor for the all-vertical-piled wharf under wave cyclic loads and ship impact loads is calculated by the FEM and the theory formula based on the single degree of freedom (SDOF) system. The results obtained by the two methods are in good agreement with each other, and the simplified calculation method of the displacement dynamic magnification factor for all-vertical-piled wharf under dynamic loads is proposed. Then the simplified calculation method determining the dynamic response for the all-vertical-piled wharf is proposed in combination with P-Y curve method. That is, the dynamic response of the structure can be obtained through the static calculation results of P-Y curve method multiplied by the displacement dynamic magnification factor. The feasibility of the simplified dynamic response method is verified by comparison with the FEM under different conditions.
基金National Key Research and Development Program(2018YFC1505401,2018YFC1505404)the National Natural Science Foundation of China(41672283,41731285,41502299)+1 种基金Youth Fund Project of NSFC(Grants No.41907225)Open fund of State Key Laboratory of geological disaster prevention and geological environment protection(Grants No.SKLGP2018K011)for their strong support for this topic
文摘The"5.12"Wenchuan earthquake in 2008 triggered a large number of co-seismic landslides.The rear boundary or cracks of co-seismic landslide are generally located at the steep free surface of thin or thick mountains.Dynamic process of this kind of landslides could be divided into two parts:the seismic dynamic response of the slope and the movement process of rock mass.Taking the Laoyingyan rockslide as an example,the amplification effect was studied by single-degree-of-freedom system analysis method.Besides,the dynamic process of landslide under seismic loading was simulated by the finite difference method(FDM)and discrete element method(DEM).The amplification coefficient of the rockslide to seismic wave is 1.25.The results show that the critical sliding surface of the Laoyingyan rockslide was formed at the 23 th seconds under the action of seismic wave.At the same time,tension failure occurred at the rear edge of the sliding mass and shear failure occurred at the front edge.The maximum displacement was 0.81 m and the initial velocity was 2.78 m/s.During the initiation process of the rockslide,the rock mass firstly broke down along the joints which are along the dip of the rock stratum,and then collapsed bodily along the secondary structural planes.In the process of movement,the maximum velocity of rock mass was 38.24 m/s.After that,the rock mass underwent multiple collisions,including contact,deceleration to 0 and speed recovery after rebound.Finally,due to the constant loss of energy,the rocks stopped and accumulated loosely at the foot of the slope.The longest distance of movement was about 494 m.Besides,the smaller the damping ratio,the farther the rock mass moved.Compared with the results without considering the amplification factor,the movement distance of landslide by considering the amplification factor was more accurate.The study of the Laoyingyan rockslide is helpful to strengthen our field identification of potential co-seismic rockslides.At the same time,understanding its movement and accumulation process can help us better predict the hazard scope of the co-seismic rockslides,and provide a reference for the design of treatment projects.
基金supported by the National Key Research and Development Program of China (Nos. 2018YFC0809600,2018YFC0809604)the National Natural Science Foundation of China(No.51678451).
文摘As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields under the normal wind and typhoon are simulated by active wind tunnel technology,and rigid-pressure-measurement model and aero-elastic-vibration-measurement model of a large cooling tower are built.The stagnation point,peak suction point,separation point and leeward point of the throat position shell are selected to analyze pressure coefficient,probability distribution,peak factor,power spectral density and dynamic amplification factor under normal wind and typhoon.It is clarified that there exists a significant non-Gaussian characteristic under typhoon condition,which also exists in structural response level.Resonance response ratio of the total response is higher during typhoon condition.The maximum value of dynamic amplification coefficient under typhoon field is up to 1.18 times over that under normal wind.The findings of this study are expected to be of interest and practical use to professional and researchers involved in the wind-resistant designs of super-large cooling towers in typhoon prone regions.