期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
A Comparison between Neutron Activation Analysis and X-Ray Fluorescence Methods in Analyzing the Granite Samples
1
作者 Hayder Salah Naeem Pegah Moradi Khaniabadi Eid Mahmoud Eid 《Journal of Chemistry and Chemical Engineering》 2013年第9期803-807,共5页
This study focused on the performance of where elements analysing techniques were used to detect the elements in granite stones. These techniques are NAA (neutron activation analysis) and XRF (X-ray fluorescence).... This study focused on the performance of where elements analysing techniques were used to detect the elements in granite stones. These techniques are NAA (neutron activation analysis) and XRF (X-ray fluorescence). They were applied to detect the elements in samples which had been chosen from different areas of Pulua Penang in Malaysia collected by geophysics group which helped to describe and identify the elements found in the granite stone that were used in the study procedures to control the analytical results. The integration of both methods has enabled the researcher to determine 40 elements in the samples. The numbers of elements detected by XRF analysis method are 12 elements (Ar, K, Sc, Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn); while, the elements detected by NAA method have three folds of elements with XRF analysis method were 35 elements (Na, AI, Si, K, Ca, Sc,Ti, Mn, Fe, Co, Ga, Ce, As, Br, Rb, Zr, Sb, I, Cs, Ba, La, Nd, Sm, Eu,Tb, Dy, Yb, Lu, Hf, Ta, W, Au, Pa and Np). Seven common elements were detected in both techniques: K, Sc, Ti, V, Mn, Fe and Co. Si has a higher concentration in NAA technique which is 331.8 ppm. Sc has a lower concentration in XRF technique which is 0.25 ppm. Nd has a lower concentration in NAA technique which is 3.09 - 10-5 ppm. Finally, it is found that the NAA is better to detect the elements than XRF. 展开更多
关键词 Radiation science radiation physics NAA XRF analyzing methods.
下载PDF
Method of analyzing vibration characteristics of armature system of hermetically sealed electromagnetic relay
2
作者 REN Wan-bin CUI Li +1 位作者 LUO Fu-biao ZHAI Guo-fu 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第3期434-438,共5页
Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system ... Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system with electromagnetic system will cause EMR malfunction. The nonlinear dynamics model of armature systems was studied by considering electro- magnetic attraction force and opposite mechanical force in this paper. Angular displacements of armature under different sinu- soidal vibration conditions are solved in order to obtain the failure mode result from armature system. Vibration tests showed the presented analyzing method is suitable for EMR. The conclusions are instructive for increasing vibration resistance of armature systems of EMR, and are significant for reliability design of switch apparatus. 展开更多
关键词 Hermetically sealed electromagnetic relay (EMR) Armature system Vibration characteristics analyzing method
下载PDF
Infrared Spectroscopic and Theoretical Studies on Cobalt(Ⅱ) Complex of Maleinitriledithiolate and 4, 4′-Dimethyl-2, 2′-bipyridine 被引量:1
3
作者 Peng Zheng-he, Cai Ping, Fang Chen-jie, Wen Li-li College of Chemistry and Molecular Sciences, Wuhan University, Wuhan 430072, Hubei, China 《Wuhan University Journal of Natural Sciences》 CAS 2002年第1期87-96,共10页
The complete experimental IR spectra and vibrational analysis of the title complex Co(mnt)(dmbpy) were reported in this paper. The results show that the complex molecule has a planar geometry belonging to point group ... The complete experimental IR spectra and vibrational analysis of the title complex Co(mnt)(dmbpy) were reported in this paper. The results show that the complex molecule has a planar geometry belonging to point group C 2v and ground electronic state with spin quartet. A new method for analyzing vibrational spectra of complicated molecule is established. The essential of this method is to point out main fixed points and pivotal vibrational units in assignment for each fundamental band. Two new symbols η (heaving along the specified direction) and M (midpoint of a bond or unit) were defined for describing the vibrational modes accurately. 展开更多
关键词 Cobalt(Ⅱ) complex infrared spectrum new method to analyze vibrational spectra quantum chemical calculation
下载PDF
The Principle of Square Hole Machining and It's Tooling Structure Design
4
作者 Jinxia NIU 《International Journal of Technology Management》 2015年第2期7-8,共2页
In order to meet the rapid needs of processing square hole in mechanical equipment, the paper expounds the square hole processing method: planetary wheel method, and analyze the principle of tooling structure and pro... In order to meet the rapid needs of processing square hole in mechanical equipment, the paper expounds the square hole processing method: planetary wheel method, and analyze the principle of tooling structure and process with computer graphics parameters design. The results that, as long as the appropriate parameters, using the above method not only can punch the square hole, can also be processed triangle, the five angle and hexagonal regular polygon holes. The square hole processing method can provide theoretical basis and engineering reliable reference for related engineering and technical personnel. 展开更多
关键词 Abstract: In order to meet the rapid needs of processing square hole in mechanical equipment the paper expounds the square hole processing method: planetary wheel method and analyze the principle of tooling structure and process with computer graphics parameters design. The results that as long as the appropriate parameters using the above method not only can punch the square hole can also be processed triangle the five angle and hexagonal regular polygon holes. The square hole processing method can provide theoretical basis and engineering reliable reference for related engineering and technical personnel. Keywords: Square hole processing Planet wheel Lelo triangle Square hole drilling
下载PDF
Using the system function to analyze the performance of transducer's impedance measurement method
5
作者 LI Haifeng ZENG Juan +3 位作者 GAO Tianfu LIU Haijun PENG Dayong ZHAO Wenyao 《Chinese Journal of Acoustics》 2013年第3期211-221,共11页
Prom investigation of the advantages and disadvantages of conventional tri-voltage method,a method for the measurement of the transmitting transducer's impedance was presented to solve the difficult problem of examin... Prom investigation of the advantages and disadvantages of conventional tri-voltage method,a method for the measurement of the transmitting transducer's impedance was presented to solve the difficult problem of examining the consistency of the transmitting phased array on the single-mode excitation sea spot.In the method based on the system function, the circuit structure of tri-voltage method was used but new parameters were measured.The principle of the method was given first.Then when resistors with different nominal values were used in the circuit,the measured results for the impedance of transducers were reported.The results were compared with the higher precision impedance analyzer.Finally,the error analysis was performed according to the impedance formula and the equivalent circuit parameters were fitted.Under the condition of guaranteeing the sampling precision,by performance analyzing, the resistor value in series was chosen relatively smaller than the impedance of transducer,the measurement of impedance could achieve the same precision as the higher precision impedance analyzer.Finally,the least squares curve-fitting of measured curves indicated that the transducer equivalent electrical parameters could be extracted accurately and used to design the matching network. 展开更多
关键词 Using the system function to analyze the performance of transducer’s impedance measurement method
原文传递
上一页 1 下一页 到第