AIM:To invastigate intra-and interobserver reliability of interferometry,tear meniscus height(TMH)measurement and meibography(MBG)of an ocular surface analyzer,LacryDiag(Quantel Medical,France).METHODS:Five consecutiv...AIM:To invastigate intra-and interobserver reliability of interferometry,tear meniscus height(TMH)measurement and meibography(MBG)of an ocular surface analyzer,LacryDiag(Quantel Medical,France).METHODS:Five consecutive measurements and subsequent analysis of interferometry,TMH,and MBG were recorded by two examiners using the LacryDiag.To assess intra-and interobserver reliability,we used Cohen’s kappa for categorical variables(interferometry),or intraclass correlation coefficient for continuous variables(TMH,MBG).RESULTS:Thirty eyes of 30 examinees were included.For both observers,there was excellent intraobserver reliability for MBG(0.955 and 0.970 for observer 1 and 2,respectively).Intraobserver reliability for observer 1 was substantial for interferometry(0.799),and excellent for TMH(0.863).Reliability for observer 2 was moderate for interferometry(0.535)and fair to good for TMH(0.431).Interobserver reliability was poor for interferometry(0.074)and fair to good for TMH(0.680)and MBG(0.414).CONCLUSION:LacryDiag ocular surface analyzer in our study proves to be a reliable noninvasive tool for the evaluation of TMH and MBG.As for interferometry,poor interobserver reliability,fair to good intraobserver reliability for observer 1,and moderate for observer 2,leave room for improvement.展开更多
The SMILE(Solar wind Magnetosphere Ionosphere Link Explorer)mission is a joint space science mission between the Chinese Academy of Sciences(CAS)and the European Space Agency(ESA),aiming to understand the interaction ...The SMILE(Solar wind Magnetosphere Ionosphere Link Explorer)mission is a joint space science mission between the Chinese Academy of Sciences(CAS)and the European Space Agency(ESA),aiming to understand the interaction of the solar wind with the Earth’s magnetosphere in a global manner.As of May 2024,the SMILE mission is in phase-D with an expected launch date of September 2025.This report summarizes developments in the mission during the past two years.展开更多
Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a sel...Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a self-developed 500-Msps,12-bit digitizer,and the neutron and gamma spectra were calculated directly on an FPGA.A fast neutron flux measurement system with BC-501A and EJ-309 liquid scintillator detectors was developed and a fast neutron measurement experiment was successfully performed on the HL-2 M tokamak at the Southwestern Institute of Physics,China.The experimental results demonstrated that the system obtained the neutron and gamma spectra with a time accuracy of 1 ms.At count rates of up to 1 Mcps,the figure of merit was greater than 1.05 for energies between 50 keV and 2.8 MeV.展开更多
Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and d...Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and divertor plasma transport in magnetically confined fusion research.On the J-TEXT tokamak,a multi-channel retarding field analyzer(RFA) probe has been developed to study average plasma parameters in the edge region under various poloidal divertor and island divertor configurations.The edge radial profile of the ion-to-electron temperature ratio,τ_(i/e),has been determined,which gradually decreases as the SOL ion self-collisionality,v_(SOL)*,increases.This is broadly consistent with what has been observed previously from various tokamak experiments.However,the comparison of experimental results under different configurations shows that in the poloidal divertor configuration,even under the same v_(SOL)*,τ_(i/e) in the SOL region becomes smaller as the distance from the X-point to the target plate increases.In the island divertor configuration,τ_(i/e) near the O-point is higher than that near the X-point at the same v_(SOL)*,and both are higher than those in the limiter configuration.These results suggest that the magnetic configuration plays a critical role in the energy distributions between electrons and ions at the plasma boundary.展开更多
An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of ...An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.展开更多
This research was conducted in the Qassim region, Kingdom of Saudi Arabia. The goal of this research is to determine the percentage of silicon in the Rub al-Khali desert. Samples were collected from four cities locate...This research was conducted in the Qassim region, Kingdom of Saudi Arabia. The goal of this research is to determine the percentage of silicon in the Rub al-Khali desert. Samples were collected from four cities located in the Al-Qassim Region of Saudi Arabia (Uyun Al-Jawa, Al-Fuwailiq, Al-Sulaibiya, and Al-Qawara), from three distinct depths (the earth’s surface, 50 cm, and 100 cm). The percentages of silicon in these places vary between the highest value for silicon dioxide, which is 74.47 m/m%, and 34.8 m/m% for silicon in Al-Qawara city at a depth of 100 cm. We used an x-ray fluorescence (XRF) instrument to evaluate the samples. There are high percentage of both silica and silicon in the Nafud desert. Studies have shown that these ratios can help investors benefit from an element of Silicon and silicon dioxide, so the sands of the Nafud desert is sufficient for extracting Silicon and silica in huge quantities. This may transform the Kingdom into a leading country in the global computer technology industry that depends on silicon extracted from the desert sands, the most important of which are microcomputer data processing devices.展开更多
To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected...To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected by digital optical 3D image analyzer and manual camera,the changes of crow’s feet with age were analyzed.Pictures obtained by manual photography can be directly used for observation and preliminary grading of wrinkles.However,the requirements for evaluators are high,and the results are prone to errors,which will affect the accuracy of the evaluation.Therefore,skilled raters are needed.Compared with the manual photography method,the digital optical 3D image analyzer EvaSKIN can realize three-dimensional extraction of wrinkles,and obtain the change trend of crow’s feet with age.20~30 years old,wrinkles begin to appear slowly;wrinkles will increase rapidly at the age of 30~50;The length of 50~60 year old wrinkles is basically fixed,the wrinkles develop longitudewise,gradually widen and deepen,and the area,depth and volume increase is obvious,and the skin aging condition is intensified.the digital optical 3D image analyzer EvaSKIN realizes the 3D extraction of wrinkles,quantifies the circumference,area,average depth,maximum depth and volume of wrinkles,realizes the objective and quantitative evaluation of wrinkle state,is more accurate in the measurement of wrinkles,and provides a new instrument and method for the evaluation of wrinkles.it is a perfect and supplement to the traditional evaluation methods,and to a certain extent,it helps the research and development and evaluation institutions of cosmetics to obtain more abundant and three-dimensional data support.展开更多
Objective:To analyze the technical indexes of students’online learning behavior analysis based on Kirkman’s evaluation model,sort out the basic indexes of online learning behavior,and extract scientific and efficien...Objective:To analyze the technical indexes of students’online learning behavior analysis based on Kirkman’s evaluation model,sort out the basic indexes of online learning behavior,and extract scientific and efficient evaluation indexes of online learning effect through statistical analysis.Methods:The online learning behavior data of Physiology of nursing students from 2021-2023 and the first semester of 22 nursing classes(3 and 4)were collected and analyzed.The preset learning behavior indexes were analyzed by multi-dimensional analysis and a correlation analysis was conducted between the indexes and the final examination scores to screen for the dominant important indexes for online learning effect evaluation.Results:The study found that the demand for online learning of nursing students from 2021-2023 increased and the effect was statistically significant.Compared with the stage assessment results,the online learning effect was statistically significant.Conclusion:The main indicators for evaluating and classifying online learning behaviors were summarized.These two indicators can help teachers predict which part of students need learning intervention,optimize the teaching process,and help students improve their learning behavior and academic performance.展开更多
Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidime...Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidimetric assay forβ2-MG as the research object,β2-MG levels were detected by different concentration gradients ofβ2-microglobulin samples in Liedemann,Mack,and Myriad reagents of three manufacturers on two automatic biochemical analyzers,and the difference of the hook effect was comparatively analyzed.Results:Leadman reagent showed the hook effect on the Beckman AU5800 automated biochemistry analyzer,while both Maccura and Mindray reagents did not show the hook effect.After the experiments,we found the limit value of the pre-zone check of Leadman reagent,and changed the parameters of the instrument,when the limit value of the pre-zone check was reached,the instrument automatically diluted the specimen five times and then detected it again.After changing the parameters of the instrument,the correlation between the three methods of detecting samples of different concentrations was r>0.99.Conclusion:Before selecting the application of immunoturbidimetric reagents,we have to carry out the risk assessment of the hook effect and selectively set the parameters of the pre-zone check based on the highest concentration that may occur in the clinic;for the items that may have the hook effect,we have to selectively set the parameters of the pre-zone check when the ratio of average reaction rate and the immediate reaction rate is at the limit value,and the phenomenon of antigen excess may occur,the instrument will carry out automatic dilution before detection,so as to avoid the issuance of erroneous results of high-value samples due to the hook effect.展开更多
The systematism of weapon combat is the typical characteristic of a modern battlefield. The process of combat is complex and the demand description of weapon system of systems (SOS) is difficult. Granular analyzing ...The systematism of weapon combat is the typical characteristic of a modern battlefield. The process of combat is complex and the demand description of weapon system of systems (SOS) is difficult. Granular analyzing is an important method for solving the complex problem in the world. Granular thinking is introduced into the demand description of weapon SoS. Granular computing and granular combination based on a relation of compatibility is proposed. Based on the level of degree and degree of detail, the granular resolution of weapon SoS is defined and an example is illustrated at the end.展开更多
Phonon modes in spherical Si quantum dots (QDs) with up to 7.9 nm in diameter are calculated by using the projection operators of the group theory into valence force field model. The phonons of dot modes in each of fi...Phonon modes in spherical Si quantum dots (QDs) with up to 7.9 nm in diameter are calculated by using the projection operators of the group theory into valence force field model. The phonons of dot modes in each of five irreducible representations (symmetries) are classified by using a dual space analysis method. It is found that the bulk-like modes with localization radius much smaller than the dot's radius have clearly pronounced bulk specific-κdefinite bulk band (one in six modes). In Si dots of all sizes, each specific bulk-like dot mode has specific symmetry.TO dot modes and bulk-like X-derived TA and LA dot modes red-shift in frequency with decreasing dot size. There is almost not LO/TO mixing for bulk-like modes. As for the surface-like modes localized at the periphery of the dot,their eigenmodes have not a dominant bulk specific-κ point parentage or a dominant BZ parentage around some special point. They are a superposition of many bulk bands with κ from all over the bulk BZ. They have much significant mode mixing than the bulk-like phonons. The classification of dot modes based on the symmetry of group theory will bring advantageous to the discussion of Ramam spectrum, electron-phonon interaction and other phonon-assisted effects in QDs.展开更多
How to determine accurately the association states of solutes in aqueous systems is of fundamental importance in a variety of chemical, physical, and biological processes, We apply four widely used criteria to analyze...How to determine accurately the association states of solutes in aqueous systems is of fundamental importance in a variety of chemical, physical, and biological processes, We apply four widely used criteria to analyze the dynamic association processes of solutes, e.g., amphiphilic molecules, and to find the inappropriate selections of representative sites on solutes in these criteria may bring about appreciable influence on the estimation of dynamic association behaviors such as unrealistic packing radii and even misleading packing structures. It would be better to select dynamically representative sites on solute molecules based on the characteristic of solute associations. Our detailed discussions give a guide on how to determine an appropriate criterion to accurately analyze the association behaviors of solute molecules in aqueous solutions.展开更多
BACKGROUND: ^31p magnetic resonance spectroscopy (^31p MRS) can be used to non-injuredly and dynamicly detect vadous metabolites including phosphorus in organis and reflect changes of phospholipid metabolism and en...BACKGROUND: ^31p magnetic resonance spectroscopy (^31p MRS) can be used to non-injuredly and dynamicly detect vadous metabolites including phosphorus in organis and reflect changes of phospholipid metabolism and energy metabolism in tissue and pH value in cells. OBJECTIVE: To observe changes of pH value, phospholipid metabolism and energy metabolism of various cerebral tumors and normal brain tissue with sip MRS. DESIGN: Semi-quantitative contrast observation PARTICIPANTS : A total of 44 patients with cerebral tumor diagnosed with surgery operation were selected from the Department of Magnetic Resonance, Central South Hospital, Wuhan University from September 2004 to June 2006. All the subjects had complete sip MRS data before steroid and operation. Among them, 16 patients had glioma of grade Ⅱ-Ⅲ, 12 spongioblastoma and 16 meningioma. The mean age was (45±6) years. Another 36 subjects without focus on cerebral MRI were regarded as normal group, including 19 males and 18 females, and the mean age was (41±4) years. Included subjects were consent. METHODS: Eclipse1.5T MRS (Philips Company) was used to collect wave spectrum; jMRUI(1.3) was used to analyze expenmental data and calculate pH value in voxel and ratios of phosphocreatine (PCr)/inorganic phosphate (Pi), PCr/phosphodiesterase (PDE) and phosphomonoesterase (PME)/β-adenosine triphosphate (β-ATP) of vadous metabolites. ^31p MRS results were compared with t test between tumor patients and normal subjects. MAIN OUTCOME MEASURES: Changes of phospholipid metabolism (PME./PDE), energy metabolism (PCr/ATP) and pH value of various cerebral tumors and normal brain tissues. RESULTS : A total of 44 cases with cerebral tumor and 36 normal subjects were involved in the final analysis. pH value and semi-quantitative measurements of normal brain tissues and various cerebral tumors: ① pH value at top occipital region and temple occipital region of normal brain tissue was 7.04 ±0.02; PCr/β-ATP was 1.51 ±0.03; PCr/Pi was 2.85±0.20; PDE/β-ATP was 2.70±0.40; PME/β-ATP was 1.01 ±0.03. Giioma of grade Ⅱ - Ⅲ : Tumor tissue was alkalized. The pH value was 7.09±0.01, which was higher than that in normal group (t=-1.823, P 〈 0.05); PCr/β-ATP, PME/β-ATP and PCr/ Pi were 1.50±0.04, 1.04±0.07 and 2.49±0.21, respectively, which was close to that in normal group (P 〉 0.05); PDE/β-ATP was 1.73±0.20, which was lower than that in normal group (t=-2.168, P 〈 0.05). ③ Spongioblastoma: Tumor tissue was alkalized. The pH value was 7.12±0.02, which was higher than that in normal group (t=-2.170, P 〈 0.05); PCr/β-ATP and PCr/Pi were 1.48±0.05 and 2.39±0.23, respectively, which was lower than that in normal group, but the difference was not significant (P 〉 0.05); PDE/β-ATP was 1.61±0.25, which was lower than that in normal group (t=-3.582, P 〈 0.01); PME/β-ATP was 1.64±0.05, which was higher than that in normal group (t=-3.930, P 〈 0.01). ④ Meningioma: Tumor tissue was alkalized. The pH value was 7.16±0.03, which was higher than that in normal group (t=-2.978, P 〈 0.01); PCr/β-ATP, PCr/Pi and PDE/β-ATP were 0.46±0.04, 1.08±0.16 and 0.82±0.10, respectively, which was lower than that in normal group (t=-3.132, 3.983, 3.985, P 〉 0.01); PME/β-ATP was 2.05±0.03, which was higher than that in normal group (t=-3.007, P〈 0.01). CONCLUSION: ^31p MRS can provide informations about pH value of cerebral tumor, phospholipid metabolism and energy metabolism. Changes of pH value, PCr, PME and PDE can reflect metabolic characteristics of various cerebral tumors.展开更多
Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system ...Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system with electromagnetic system will cause EMR malfunction. The nonlinear dynamics model of armature systems was studied by considering electro- magnetic attraction force and opposite mechanical force in this paper. Angular displacements of armature under different sinu- soidal vibration conditions are solved in order to obtain the failure mode result from armature system. Vibration tests showed the presented analyzing method is suitable for EMR. The conclusions are instructive for increasing vibration resistance of armature systems of EMR, and are significant for reliability design of switch apparatus.展开更多
The pitch angle distributions of ions and electrons can be affected by various processes;thus,they can serve as an important indicator of the physical mechanisms driving the dynamics of space plasmas.From observations...The pitch angle distributions of ions and electrons can be affected by various processes;thus,they can serve as an important indicator of the physical mechanisms driving the dynamics of space plasmas.From observations from the Mars Ion and Neutral Particle Analyzer onboard the Tianwen-1 orbiter,we calculated the pitch angle distributions of protons in the Martian induced magnetosphere by using information from the magnetohydrodynamically simulated magnetic field,and we statistically analyzed the spatial occurrence pattern of different types of pitch angle distributions.Even though no symmetrical features were seen in the dataset,we found the dominance of the field-aligned distribution type over the energy range from 188 to 6232 eV.Maps of the occurrence rate showed the preferential presence of a trapped-like distribution at the lower altitudes of the surveyed nightside region.Although our results are more or less restricted by the adopted magnetic field,they indicate the complexity of the near-Mars proton pitch angle distributions and infer the possibility of wave–particle interactions in the Martian induced magnetosphere.展开更多
Regeneration in the central nervous system (CNS) is limited, and CNS damage often leads to cognitive impairment or permanent functional motor and sensory loss. Impaired regenerative capacity is multifactorial and in...Regeneration in the central nervous system (CNS) is limited, and CNS damage often leads to cognitive impairment or permanent functional motor and sensory loss. Impaired regenerative capacity is multifactorial and includes inflammation, loss of the blood-brain barrier, and alteration in the extracellular matrix (ECM). One of the main problems is the formation of a glial scar and the production of inhibitory ECM, such as proteoglycans, that generates a physical and mechanical barrier, impeding axonal regrowth (Figure 1A).展开更多
A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only availabl...A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only available in hospitals or laboratories,hindering the spread of point-of-care testing(POCT),especially in underdeveloped areas.Here,we propose a smart Palm-size Optofluidic Hematology Analyzer based on a miniature fluorescence microscope and a microfluidic platform to lighten the device to improve its portability.This gadget has a dimension of 35×30×80 mm and a mass of 39 g,less than 5%of the weight of commercially available flow cytometers.Additionally,automatic leukocyte concentration detection has been realized through the integration of image processing and leukocyte counting algorithms.We compared the leukocyte concentration measurement between our approach and a hemocytometer using the Passing-Bablok analysis and achieved a correlation coefficient of 0.979.Through Bland-Altman analysis,we obtained the relationship between their differences and mean measurement values and established 95%limits of agreement,ranging from−0.93×10^(3)to 0.94×10^(3)cells/μL.We anticipate that this device can be used widely for monitoring and treating diseases such as HIV and tumors beyond hospitals.展开更多
Software tools are developed for computer realization of syntactic, semantic, and morphological models of natural language texts, using rule based programming. The tools are efficient for a language, which has free or...Software tools are developed for computer realization of syntactic, semantic, and morphological models of natural language texts, using rule based programming. The tools are efficient for a language, which has free order of words and developed morphological structure like Georgian. For instance, a Georgian verb has several thousand verb-forms. It is very difficult to express rules of morphological analysis by finite automaton and it will be inefficient as well. Resolution of some problems of full morphological analysis of Georgian words is impossible by finite automaton. Splitting of some Georgian verb-forms into morphemes requires non-deterministic search algorithm, which needs many backtrackings. To minimize backtrackings, it is necessary to put constraints, which exist among morphemes and verify them as soon as possible to avoid false directions of search. Software tool for syntactic analysis has means to reduce rules, which have the same members in different order. The authors used the tool for semantic analysis as well. Thus, proposed software tools have many means to construct efficient parser, test and correct it. The authors realized morphological and syntactic analysis of Georgian texts by these tools. In the presented paper, the authors describe the software tools and its application for Georgian language.展开更多
A network analyzer can often comprehend many protocols, which enables it to display talks taking place between hosts over a network. A network analyzer analyzes the device or network response and measures for the oper...A network analyzer can often comprehend many protocols, which enables it to display talks taking place between hosts over a network. A network analyzer analyzes the device or network response and measures for the operator to keep an eye on the network’s or object’s performance in an RF circuit. The purpose of the following research includes analyzing the capabilities of NetFlow analyzer to measure various parts, including filters, mixers, frequency sensitive networks, transistors, and other RF-based instruments. NetFlow Analyzer is a network traffic analyzer that measures the network parameters of electrical networks. Although there are other types of network parameter sets including Y, Z, & H-parameters, these instruments are typically employed to measure S-parameters since transmission & reflection of electrical networks are simple to calculate at high frequencies. These analyzers are widely employed to distinguish between two-port networks, including filters and amplifiers. By allowing the user to view the actual data that is sent over a network, packet by packet, a network analyzer informs you of what is happening there. Also, this research will contain the design model of NetFlow Analyzer that Measurements involving transmission and reflection use. Gain, insertion loss, and transmission coefficient are measured in transmission measurements, whereas return loss, reflection coefficient, impedance, and other variables are measured in reflection measurements. These analyzers’ operational frequencies vary from 1 Hz to 1.5 THz. These analyzers can also be used to examine stability in measurements of open loops, audio components, and ultrasonics.展开更多
文摘AIM:To invastigate intra-and interobserver reliability of interferometry,tear meniscus height(TMH)measurement and meibography(MBG)of an ocular surface analyzer,LacryDiag(Quantel Medical,France).METHODS:Five consecutive measurements and subsequent analysis of interferometry,TMH,and MBG were recorded by two examiners using the LacryDiag.To assess intra-and interobserver reliability,we used Cohen’s kappa for categorical variables(interferometry),or intraclass correlation coefficient for continuous variables(TMH,MBG).RESULTS:Thirty eyes of 30 examinees were included.For both observers,there was excellent intraobserver reliability for MBG(0.955 and 0.970 for observer 1 and 2,respectively).Intraobserver reliability for observer 1 was substantial for interferometry(0.799),and excellent for TMH(0.863).Reliability for observer 2 was moderate for interferometry(0.535)and fair to good for TMH(0.431).Interobserver reliability was poor for interferometry(0.074)and fair to good for TMH(0.680)and MBG(0.414).CONCLUSION:LacryDiag ocular surface analyzer in our study proves to be a reliable noninvasive tool for the evaluation of TMH and MBG.As for interferometry,poor interobserver reliability,fair to good intraobserver reliability for observer 1,and moderate for observer 2,leave room for improvement.
基金Founded by the Strategic Priority Research Program on Space Science,the Chinese Academy of Sciences(XDA15350000)。
文摘The SMILE(Solar wind Magnetosphere Ionosphere Link Explorer)mission is a joint space science mission between the Chinese Academy of Sciences(CAS)and the European Space Agency(ESA),aiming to understand the interaction of the solar wind with the Earth’s magnetosphere in a global manner.As of May 2024,the SMILE mission is in phase-D with an expected launch date of September 2025.This report summarizes developments in the mission during the past two years.
基金supported by the National Magnetic Confinement Fusion Program of China(No.2019YFE03020002)the National Natural Science Foundation of China(Nos.12205085 and12125502)。
文摘Fast neutron flux measurements with high count rates and high time resolution have important applications in equipment such as tokamaks.In this study,real-time neutron and gamma discrimination was implemented on a self-developed 500-Msps,12-bit digitizer,and the neutron and gamma spectra were calculated directly on an FPGA.A fast neutron flux measurement system with BC-501A and EJ-309 liquid scintillator detectors was developed and a fast neutron measurement experiment was successfully performed on the HL-2 M tokamak at the Southwestern Institute of Physics,China.The experimental results demonstrated that the system obtained the neutron and gamma spectra with a time accuracy of 1 ms.At count rates of up to 1 Mcps,the figure of merit was greater than 1.05 for energies between 50 keV and 2.8 MeV.
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China (No.2018YFE0309100)National Natural Science Foundation of China (No.51821005)。
文摘Accurate measurement of the average plasma parameters in the edge region,including the temperature and density of electrons and ions,is critical for understanding the characteristics of the scrape-off layer(SOL) and divertor plasma transport in magnetically confined fusion research.On the J-TEXT tokamak,a multi-channel retarding field analyzer(RFA) probe has been developed to study average plasma parameters in the edge region under various poloidal divertor and island divertor configurations.The edge radial profile of the ion-to-electron temperature ratio,τ_(i/e),has been determined,which gradually decreases as the SOL ion self-collisionality,v_(SOL)*,increases.This is broadly consistent with what has been observed previously from various tokamak experiments.However,the comparison of experimental results under different configurations shows that in the poloidal divertor configuration,even under the same v_(SOL)*,τ_(i/e) in the SOL region becomes smaller as the distance from the X-point to the target plate increases.In the island divertor configuration,τ_(i/e) near the O-point is higher than that near the X-point at the same v_(SOL)*,and both are higher than those in the limiter configuration.These results suggest that the magnetic configuration plays a critical role in the energy distributions between electrons and ions at the plasma boundary.
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China(No.2018YFE0310200)National Natural Science Foundation of China(Nos.11705242,11805138 and 12175156)the Fundamental Research Funds for the Central Universities in China(Nos.YJ201820 and YJ201954)。
文摘An E//B neutral particle analyzer(NPA)has been designed and is under development at Sichuan University and Southwestern Institute of Physics.The main purpose of the E//B NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak.The E//B NPA contains three main units,i.e.the stripping unit,the analyzing unit and the detection unit.A gas stripping chamber was adopted as the stripping unit.The results of the simulations and beam tests for the stripping chamber are presented.Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit.The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source(ECRIS)platform.The detection unit consists of 32lutetium-yttrium oxyorthosilicate(LYSO)detector modules arranged in two rows.The response functions ofα,hydrogen ions(H^(+),H_(2)^(+)and H_(3)^(+))andγfor a detector module were measured with^(241)Am,^(137)Cs and^(152)Eu sources together with the 50 kV ECRIS platform.The overall results indicate that the designed E//B NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.
文摘This research was conducted in the Qassim region, Kingdom of Saudi Arabia. The goal of this research is to determine the percentage of silicon in the Rub al-Khali desert. Samples were collected from four cities located in the Al-Qassim Region of Saudi Arabia (Uyun Al-Jawa, Al-Fuwailiq, Al-Sulaibiya, and Al-Qawara), from three distinct depths (the earth’s surface, 50 cm, and 100 cm). The percentages of silicon in these places vary between the highest value for silicon dioxide, which is 74.47 m/m%, and 34.8 m/m% for silicon in Al-Qawara city at a depth of 100 cm. We used an x-ray fluorescence (XRF) instrument to evaluate the samples. There are high percentage of both silica and silicon in the Nafud desert. Studies have shown that these ratios can help investors benefit from an element of Silicon and silicon dioxide, so the sands of the Nafud desert is sufficient for extracting Silicon and silica in huge quantities. This may transform the Kingdom into a leading country in the global computer technology industry that depends on silicon extracted from the desert sands, the most important of which are microcomputer data processing devices.
文摘To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected by digital optical 3D image analyzer and manual camera,the changes of crow’s feet with age were analyzed.Pictures obtained by manual photography can be directly used for observation and preliminary grading of wrinkles.However,the requirements for evaluators are high,and the results are prone to errors,which will affect the accuracy of the evaluation.Therefore,skilled raters are needed.Compared with the manual photography method,the digital optical 3D image analyzer EvaSKIN can realize three-dimensional extraction of wrinkles,and obtain the change trend of crow’s feet with age.20~30 years old,wrinkles begin to appear slowly;wrinkles will increase rapidly at the age of 30~50;The length of 50~60 year old wrinkles is basically fixed,the wrinkles develop longitudewise,gradually widen and deepen,and the area,depth and volume increase is obvious,and the skin aging condition is intensified.the digital optical 3D image analyzer EvaSKIN realizes the 3D extraction of wrinkles,quantifies the circumference,area,average depth,maximum depth and volume of wrinkles,realizes the objective and quantitative evaluation of wrinkle state,is more accurate in the measurement of wrinkles,and provides a new instrument and method for the evaluation of wrinkles.it is a perfect and supplement to the traditional evaluation methods,and to a certain extent,it helps the research and development and evaluation institutions of cosmetics to obtain more abundant and three-dimensional data support.
基金Analysis and Research on Online Learning in Higher Vocational Colleges Based on Kirkpatrick Model-Taking the Course of Physiology as an Example(Project No.:D/2021/03/91)The excellent teaching team of Physiology of Suzhou Vocational College of Health Science and Technology in 2019(Project number:JXTD201912).
文摘Objective:To analyze the technical indexes of students’online learning behavior analysis based on Kirkman’s evaluation model,sort out the basic indexes of online learning behavior,and extract scientific and efficient evaluation indexes of online learning effect through statistical analysis.Methods:The online learning behavior data of Physiology of nursing students from 2021-2023 and the first semester of 22 nursing classes(3 and 4)were collected and analyzed.The preset learning behavior indexes were analyzed by multi-dimensional analysis and a correlation analysis was conducted between the indexes and the final examination scores to screen for the dominant important indexes for online learning effect evaluation.Results:The study found that the demand for online learning of nursing students from 2021-2023 increased and the effect was statistically significant.Compared with the stage assessment results,the online learning effect was statistically significant.Conclusion:The main indicators for evaluating and classifying online learning behaviors were summarized.These two indicators can help teachers predict which part of students need learning intervention,optimize the teaching process,and help students improve their learning behavior and academic performance.
基金Baoding Science and Technology Bureau(2141ZF313)。
文摘Objective:To investigate the hook effect in the detection of beta2-microglobulin(β2-MG)with different reagents as well as on two fully automated biochemical analyzers and their solutions.Methods:Using immunoturbidimetric assay forβ2-MG as the research object,β2-MG levels were detected by different concentration gradients ofβ2-microglobulin samples in Liedemann,Mack,and Myriad reagents of three manufacturers on two automatic biochemical analyzers,and the difference of the hook effect was comparatively analyzed.Results:Leadman reagent showed the hook effect on the Beckman AU5800 automated biochemistry analyzer,while both Maccura and Mindray reagents did not show the hook effect.After the experiments,we found the limit value of the pre-zone check of Leadman reagent,and changed the parameters of the instrument,when the limit value of the pre-zone check was reached,the instrument automatically diluted the specimen five times and then detected it again.After changing the parameters of the instrument,the correlation between the three methods of detecting samples of different concentrations was r>0.99.Conclusion:Before selecting the application of immunoturbidimetric reagents,we have to carry out the risk assessment of the hook effect and selectively set the parameters of the pre-zone check based on the highest concentration that may occur in the clinic;for the items that may have the hook effect,we have to selectively set the parameters of the pre-zone check when the ratio of average reaction rate and the immediate reaction rate is at the limit value,and the phenomenon of antigen excess may occur,the instrument will carry out automatic dilution before detection,so as to avoid the issuance of erroneous results of high-value samples due to the hook effect.
文摘The systematism of weapon combat is the typical characteristic of a modern battlefield. The process of combat is complex and the demand description of weapon system of systems (SOS) is difficult. Granular analyzing is an important method for solving the complex problem in the world. Granular thinking is introduced into the demand description of weapon SoS. Granular computing and granular combination based on a relation of compatibility is proposed. Based on the level of degree and degree of detail, the granular resolution of weapon SoS is defined and an example is illustrated at the end.
文摘Phonon modes in spherical Si quantum dots (QDs) with up to 7.9 nm in diameter are calculated by using the projection operators of the group theory into valence force field model. The phonons of dot modes in each of five irreducible representations (symmetries) are classified by using a dual space analysis method. It is found that the bulk-like modes with localization radius much smaller than the dot's radius have clearly pronounced bulk specific-κdefinite bulk band (one in six modes). In Si dots of all sizes, each specific bulk-like dot mode has specific symmetry.TO dot modes and bulk-like X-derived TA and LA dot modes red-shift in frequency with decreasing dot size. There is almost not LO/TO mixing for bulk-like modes. As for the surface-like modes localized at the periphery of the dot,their eigenmodes have not a dominant bulk specific-κ point parentage or a dominant BZ parentage around some special point. They are a superposition of many bulk bands with κ from all over the bulk BZ. They have much significant mode mixing than the bulk-like phonons. The classification of dot modes based on the symmetry of group theory will bring advantageous to the discussion of Ramam spectrum, electron-phonon interaction and other phonon-assisted effects in QDs.
基金Supported by the National Science Fund for Outstanding Young Scholars under Grant No 11422542the Key Research Program of Chinese Academy of Sciences under Grant No KJZD-EW-M03,KIPCAS+1 种基金the Shanghai Supercomputer Center of Chinathe High Performance Computing Center of Shanghai University
文摘How to determine accurately the association states of solutes in aqueous systems is of fundamental importance in a variety of chemical, physical, and biological processes, We apply four widely used criteria to analyze the dynamic association processes of solutes, e.g., amphiphilic molecules, and to find the inappropriate selections of representative sites on solutes in these criteria may bring about appreciable influence on the estimation of dynamic association behaviors such as unrealistic packing radii and even misleading packing structures. It would be better to select dynamically representative sites on solute molecules based on the characteristic of solute associations. Our detailed discussions give a guide on how to determine an appropriate criterion to accurately analyze the association behaviors of solute molecules in aqueous solutions.
基金the grants fromHealth Department of HubeiProvince, No. 301140319
文摘BACKGROUND: ^31p magnetic resonance spectroscopy (^31p MRS) can be used to non-injuredly and dynamicly detect vadous metabolites including phosphorus in organis and reflect changes of phospholipid metabolism and energy metabolism in tissue and pH value in cells. OBJECTIVE: To observe changes of pH value, phospholipid metabolism and energy metabolism of various cerebral tumors and normal brain tissue with sip MRS. DESIGN: Semi-quantitative contrast observation PARTICIPANTS : A total of 44 patients with cerebral tumor diagnosed with surgery operation were selected from the Department of Magnetic Resonance, Central South Hospital, Wuhan University from September 2004 to June 2006. All the subjects had complete sip MRS data before steroid and operation. Among them, 16 patients had glioma of grade Ⅱ-Ⅲ, 12 spongioblastoma and 16 meningioma. The mean age was (45±6) years. Another 36 subjects without focus on cerebral MRI were regarded as normal group, including 19 males and 18 females, and the mean age was (41±4) years. Included subjects were consent. METHODS: Eclipse1.5T MRS (Philips Company) was used to collect wave spectrum; jMRUI(1.3) was used to analyze expenmental data and calculate pH value in voxel and ratios of phosphocreatine (PCr)/inorganic phosphate (Pi), PCr/phosphodiesterase (PDE) and phosphomonoesterase (PME)/β-adenosine triphosphate (β-ATP) of vadous metabolites. ^31p MRS results were compared with t test between tumor patients and normal subjects. MAIN OUTCOME MEASURES: Changes of phospholipid metabolism (PME./PDE), energy metabolism (PCr/ATP) and pH value of various cerebral tumors and normal brain tissues. RESULTS : A total of 44 cases with cerebral tumor and 36 normal subjects were involved in the final analysis. pH value and semi-quantitative measurements of normal brain tissues and various cerebral tumors: ① pH value at top occipital region and temple occipital region of normal brain tissue was 7.04 ±0.02; PCr/β-ATP was 1.51 ±0.03; PCr/Pi was 2.85±0.20; PDE/β-ATP was 2.70±0.40; PME/β-ATP was 1.01 ±0.03. Giioma of grade Ⅱ - Ⅲ : Tumor tissue was alkalized. The pH value was 7.09±0.01, which was higher than that in normal group (t=-1.823, P 〈 0.05); PCr/β-ATP, PME/β-ATP and PCr/ Pi were 1.50±0.04, 1.04±0.07 and 2.49±0.21, respectively, which was close to that in normal group (P 〉 0.05); PDE/β-ATP was 1.73±0.20, which was lower than that in normal group (t=-2.168, P 〈 0.05). ③ Spongioblastoma: Tumor tissue was alkalized. The pH value was 7.12±0.02, which was higher than that in normal group (t=-2.170, P 〈 0.05); PCr/β-ATP and PCr/Pi were 1.48±0.05 and 2.39±0.23, respectively, which was lower than that in normal group, but the difference was not significant (P 〉 0.05); PDE/β-ATP was 1.61±0.25, which was lower than that in normal group (t=-3.582, P 〈 0.01); PME/β-ATP was 1.64±0.05, which was higher than that in normal group (t=-3.930, P 〈 0.01). ④ Meningioma: Tumor tissue was alkalized. The pH value was 7.16±0.03, which was higher than that in normal group (t=-2.978, P 〈 0.01); PCr/β-ATP, PCr/Pi and PDE/β-ATP were 0.46±0.04, 1.08±0.16 and 0.82±0.10, respectively, which was lower than that in normal group (t=-3.132, 3.983, 3.985, P 〉 0.01); PME/β-ATP was 2.05±0.03, which was higher than that in normal group (t=-3.007, P〈 0.01). CONCLUSION: ^31p MRS can provide informations about pH value of cerebral tumor, phospholipid metabolism and energy metabolism. Changes of pH value, PCr, PME and PDE can reflect metabolic characteristics of various cerebral tumors.
基金Project (No. FEBQ24409102) supported by the Space Technology Innovation Fund, China
文摘Published research is minimal on vibration characteristics of hermetically sealed electromagnetic relay (EMR) ex- posed to mechanical environment. The vibration characteristics of armature system, link contact system with electromagnetic system will cause EMR malfunction. The nonlinear dynamics model of armature systems was studied by considering electro- magnetic attraction force and opposite mechanical force in this paper. Angular displacements of armature under different sinu- soidal vibration conditions are solved in order to obtain the failure mode result from armature system. Vibration tests showed the presented analyzing method is suitable for EMR. The conclusions are instructive for increasing vibration resistance of armature systems of EMR, and are significant for reliability design of switch apparatus.
基金supported by the National Natural Science Foundation of China(Grant No.42241143)the pre-research projects on Civil Aerospace Technologies(No.D020104)funded by the China National Space Administration.
文摘The pitch angle distributions of ions and electrons can be affected by various processes;thus,they can serve as an important indicator of the physical mechanisms driving the dynamics of space plasmas.From observations from the Mars Ion and Neutral Particle Analyzer onboard the Tianwen-1 orbiter,we calculated the pitch angle distributions of protons in the Martian induced magnetosphere by using information from the magnetohydrodynamically simulated magnetic field,and we statistically analyzed the spatial occurrence pattern of different types of pitch angle distributions.Even though no symmetrical features were seen in the dataset,we found the dominance of the field-aligned distribution type over the energy range from 188 to 6232 eV.Maps of the occurrence rate showed the preferential presence of a trapped-like distribution at the lower altitudes of the surveyed nightside region.Although our results are more or less restricted by the adopted magnetic field,they indicate the complexity of the near-Mars proton pitch angle distributions and infer the possibility of wave–particle interactions in the Martian induced magnetosphere.
文摘Regeneration in the central nervous system (CNS) is limited, and CNS damage often leads to cognitive impairment or permanent functional motor and sensory loss. Impaired regenerative capacity is multifactorial and includes inflammation, loss of the blood-brain barrier, and alteration in the extracellular matrix (ECM). One of the main problems is the formation of a glial scar and the production of inhibitory ECM, such as proteoglycans, that generates a physical and mechanical barrier, impeding axonal regrowth (Figure 1A).
基金supported by the National Natural Science Foundation of China (grant no.62305083 to W.Z.,grant no.T2222009 to H.L.,grant no.32227802 to H.L.)China Postdoctoral Science Foundation (grant no.2023T160163 to W.Z.grant no.2022M720971 to W.Z.)+2 种基金the Heilongjiang Provincial Postdoctoral Science Foundation (grant no.LBH-Z22027 to W.Z.)the National Key Research and Development Program of China (grant no.2022YFC3400600 to H.L.)the Natural Science Foundation of Heilongjiang Province (grant no.YQ2021F013 to H.L.).
文摘A critical function of flow cytometry is to count the concentration of blood cells,which helps in the diagnosis of certain diseases.However,the bulky nature of commercial flow cytometers makes such tests only available in hospitals or laboratories,hindering the spread of point-of-care testing(POCT),especially in underdeveloped areas.Here,we propose a smart Palm-size Optofluidic Hematology Analyzer based on a miniature fluorescence microscope and a microfluidic platform to lighten the device to improve its portability.This gadget has a dimension of 35×30×80 mm and a mass of 39 g,less than 5%of the weight of commercially available flow cytometers.Additionally,automatic leukocyte concentration detection has been realized through the integration of image processing and leukocyte counting algorithms.We compared the leukocyte concentration measurement between our approach and a hemocytometer using the Passing-Bablok analysis and achieved a correlation coefficient of 0.979.Through Bland-Altman analysis,we obtained the relationship between their differences and mean measurement values and established 95%limits of agreement,ranging from−0.93×10^(3)to 0.94×10^(3)cells/μL.We anticipate that this device can be used widely for monitoring and treating diseases such as HIV and tumors beyond hospitals.
文摘Software tools are developed for computer realization of syntactic, semantic, and morphological models of natural language texts, using rule based programming. The tools are efficient for a language, which has free order of words and developed morphological structure like Georgian. For instance, a Georgian verb has several thousand verb-forms. It is very difficult to express rules of morphological analysis by finite automaton and it will be inefficient as well. Resolution of some problems of full morphological analysis of Georgian words is impossible by finite automaton. Splitting of some Georgian verb-forms into morphemes requires non-deterministic search algorithm, which needs many backtrackings. To minimize backtrackings, it is necessary to put constraints, which exist among morphemes and verify them as soon as possible to avoid false directions of search. Software tool for syntactic analysis has means to reduce rules, which have the same members in different order. The authors used the tool for semantic analysis as well. Thus, proposed software tools have many means to construct efficient parser, test and correct it. The authors realized morphological and syntactic analysis of Georgian texts by these tools. In the presented paper, the authors describe the software tools and its application for Georgian language.
文摘A network analyzer can often comprehend many protocols, which enables it to display talks taking place between hosts over a network. A network analyzer analyzes the device or network response and measures for the operator to keep an eye on the network’s or object’s performance in an RF circuit. The purpose of the following research includes analyzing the capabilities of NetFlow analyzer to measure various parts, including filters, mixers, frequency sensitive networks, transistors, and other RF-based instruments. NetFlow Analyzer is a network traffic analyzer that measures the network parameters of electrical networks. Although there are other types of network parameter sets including Y, Z, & H-parameters, these instruments are typically employed to measure S-parameters since transmission & reflection of electrical networks are simple to calculate at high frequencies. These analyzers are widely employed to distinguish between two-port networks, including filters and amplifiers. By allowing the user to view the actual data that is sent over a network, packet by packet, a network analyzer informs you of what is happening there. Also, this research will contain the design model of NetFlow Analyzer that Measurements involving transmission and reflection use. Gain, insertion loss, and transmission coefficient are measured in transmission measurements, whereas return loss, reflection coefficient, impedance, and other variables are measured in reflection measurements. These analyzers’ operational frequencies vary from 1 Hz to 1.5 THz. These analyzers can also be used to examine stability in measurements of open loops, audio components, and ultrasonics.