Based on energy dissipation and structural control principle, a new structural configuration, called the megasub controlled structure (MSCS) with friction damped braces (FDBs), is first presented. Meanwhile, to ca...Based on energy dissipation and structural control principle, a new structural configuration, called the megasub controlled structure (MSCS) with friction damped braces (FDBs), is first presented. Meanwhile, to calculate the damping coefficient in the slipping state a new analytical method is proposed. The damping characteristics of one-storey friction damped braced frame (FDBF) are investigated, and the influence of the structural parameters on the energy dissipation and the practical engineering design are discussed. The nonlinear dynamic equations and the analytical model of the MSCS with FDBs are established. Three building structures with different structural configurations, which were designed with reference to the conventional mega-sub structures such as used in Tokyo City Hall, are comparatively investigated. The results illustrate that the structure presented in the paper has excellent dynamic properties and satisfactory control effectiveness.展开更多
Slamming on bracings of column stabilized units shall be considered as a possible limiting criterion under transit condition based on the requirements in DNV-OS-C103. However, the wave slamming loads under survival co...Slamming on bracings of column stabilized units shall be considered as a possible limiting criterion under transit condition based on the requirements in DNV-OS-C103. However, the wave slamming loads under survival condition were ignored for the strength analysis of the brace structures in many semi-submersible projects. In this paper, a method of strength analysis of brace structure is proposed based on the reconstruction and extrapolation of numerical model. The full-scale mooring system, the wind, wave and current loads can be considered simultaneously. Firstly,the model tests of the semi-submersible platform in wind tunnel and wave tanker have been carried out. Secondly,the numerical models of the platform are reconstructed and extrapolated based on the results of model tests. Then, a nonlinear numerical analysis has been conducted to study the wave slamming load on brace in semi-submersible platform through the reconstructed and extrapolated numerical model. For the randomness of wave load, ten subcases under each condition have been carried out. The value of the 90% Gumble distribution values of the ten subcases are used. Finally, the strength on brace structure has been analyzed considering the wave slamming. The wave slamming loads have been compared between the survival condition and transit condition with the method. The results indicate that wave slamming under survival condition is more critical than that under transit condition.Meanwhile, the wave slamming is significant to the structural strength of the brace. It should be overall considered in the strength analysis of the brace structure.展开更多
Determining initial pretension values of pre-stressed cables is one of the key problems for a steel mega frame and pre-stressed composite bracing structure.Through the mechanical analysis of the composite bracing unde...Determining initial pretension values of pre-stressed cables is one of the key problems for a steel mega frame and pre-stressed composite bracing structure.Through the mechanical analysis of the composite bracing under vertical loading,the critical factors deciding the initial pretention value were found.According to these factors,a rule for the initial pretension value was put forward.The determination equations were acquired based on the principle of force equilibrium at nodes.The numerical results indicate that the internal force disequilibrium in composite bracings resulted from symmetrical load can be eliminated only in a symmetrical way,so that initial pretention values are decided only by vertical loads.The influencing coefficient leveling method,taking into account interactions between story and story,is accurate and feasible.展开更多
A magnetorheological self-centering brace(MR–SCB)has been proposed to improve the energy dissipation capability of the brace.In this paper,a 15-story MR–SCB braced frame is numerically analyzed to examine its seismi...A magnetorheological self-centering brace(MR–SCB)has been proposed to improve the energy dissipation capability of the brace.In this paper,a 15-story MR–SCB braced frame is numerically analyzed to examine its seismic performance and resilience.The MR–SCB provides higher lateral stiffness than the buckling restrained brace and greater energy dissipation capability than the existing self-centering brace.The brace also exhibits a reliable recentering capacity.Under rare earthquakes,the maximum average residual deformation ratio of the structure is less than the 0.5%limit.Under mega earthquakes,the maximum average interstory drift ratio of the structure does not exceed the 2.0%elastoplastic limit,and its maximum average floor acceleration ratio is 1.57.The effects of mainshock and aftershock on the structural behavior are also investigated.The interstory drift and residual deformation of the structure increase with the increase of the intensity of the aftershock.Under aftershocks with the same intensity as the mainshocks,the maximum increment of the residual deformation ratio of the structure is 81.8%,and the average interstory drift ratios of the 12^(th),7^(th),and 3^(rd)stories of the structure are increased by 13.4%,9.2%and 7.5%,respectively.The strong aftershock may significantly cause increased damage to the structure,and increase its collapse risk and residual deformation.展开更多
Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and ...Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity.展开更多
One of the founders of structural control theory and its application in civil engineering, Professor Emeritus Tsu T. Soong, envisioned the development of the integral design of structures protected by active control d...One of the founders of structural control theory and its application in civil engineering, Professor Emeritus Tsu T. Soong, envisioned the development of the integral design of structures protected by active control devices. Most of his disciples and colleagues continuously attempted to develop procedures to achieve such integral control. In his recent papers published jointly with some of the authors of this paper, Professor Soong developed design procedures for the entire structure using a design - redesign procedure applied to elastic systems. Such a procedure was developed as an extension of other work by his disciples. This paper summarizes some recent techniques that use traditional active control algorithms to derive the most suitable (optimal, stable) control force, which could then be implemented with a combination of active, passive and semi-active devices through a simple match or more sophisticated optimal procedures. Alternative design can address the behavior of structures using Liapunov stability criteria. This paper shows a unified procedure which can be applied to both elastic and inelastic structures. Although the implementation does not always preserve the optimal criteria, it is shown that the solutions are effective and practical for design of supplemental damping, stiffness enhancement or softening, and strengthening or weakening.展开更多
Expansive soils can pose tough issues to civil engineering applications. In a typical year, expansive soils can cause a greater financial loss than earthquakes, floods, hurricanes and tornadoes combined. Various means...Expansive soils can pose tough issues to civil engineering applications. In a typical year, expansive soils can cause a greater financial loss than earthquakes, floods, hurricanes and tornadoes combined. Various means have been studied to tackle problems associated with expansive soils. The majority of the methods are based on treatment of the soils. While the methods may be effective in some cases, their limitations are also obvious: The treatment normally involves complex processes and may not be eco-friendly in the long run. In many cases, the effectiveness of the treatment is uncertain. A retaining system that maintains a constant lateral pressure is proposed, which consists of three components: the retaining sheet, the slip-force device and the bracing column. The retaining sheet bears the pressure exerted by expansive backfills and is not embedded into the soils. Placed between the retaining sheet and bracing column, the slip-force device permits displacement of the retaining sheet but keeps the force on the sheet and the bracing column constant. The governing equation of the motion of the piston in the slip-force device is derived and a numerical simulation of a practical case is conducted based on the derived governing equation. Numerical results show that as the expansive soil swell, the spring force will increase and the piston will move accordingly. When the pressure of the oil in chamber reach<span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">es</span></span></span><span><span><span style="font-family:;" "=""><span style="font-family:Verdana;"> the open threshold of the unidirectional relief valve, the valve will open and the spring force and the oil pressure in the chamber will keep constant. The results also show that some parameters, such as damping ratio, have very slight influences on the device behavior, say 2 × 10</span><sup><span style="font-family:Verdana;">-6</span></sup><span style="font-family:Verdana;"> or even 4.8 × 10</span><sup><span style="font-family:Verdana;">-9</span></sup><span style="font-family:Verdana;">. Theoretical and numerical studies prove the effectiveness of the proposed retaining system.</span></span></span></span>展开更多
基金Science and Technology Fund of NWPU Under Grant No. M450211 Seed Fund of NWPU Under Grant No. Z200729
文摘Based on energy dissipation and structural control principle, a new structural configuration, called the megasub controlled structure (MSCS) with friction damped braces (FDBs), is first presented. Meanwhile, to calculate the damping coefficient in the slipping state a new analytical method is proposed. The damping characteristics of one-storey friction damped braced frame (FDBF) are investigated, and the influence of the structural parameters on the energy dissipation and the practical engineering design are discussed. The nonlinear dynamic equations and the analytical model of the MSCS with FDBs are established. Three building structures with different structural configurations, which were designed with reference to the conventional mega-sub structures such as used in Tokyo City Hall, are comparatively investigated. The results illustrate that the structure presented in the paper has excellent dynamic properties and satisfactory control effectiveness.
基金financially supported by the Natural Science Foundation of Jiangsu Province(Grant No.BK20170575)University Science Research Project of Jiangsu Province(Grant No.17KJB580005)
文摘Slamming on bracings of column stabilized units shall be considered as a possible limiting criterion under transit condition based on the requirements in DNV-OS-C103. However, the wave slamming loads under survival condition were ignored for the strength analysis of the brace structures in many semi-submersible projects. In this paper, a method of strength analysis of brace structure is proposed based on the reconstruction and extrapolation of numerical model. The full-scale mooring system, the wind, wave and current loads can be considered simultaneously. Firstly,the model tests of the semi-submersible platform in wind tunnel and wave tanker have been carried out. Secondly,the numerical models of the platform are reconstructed and extrapolated based on the results of model tests. Then, a nonlinear numerical analysis has been conducted to study the wave slamming load on brace in semi-submersible platform through the reconstructed and extrapolated numerical model. For the randomness of wave load, ten subcases under each condition have been carried out. The value of the 90% Gumble distribution values of the ten subcases are used. Finally, the strength on brace structure has been analyzed considering the wave slamming. The wave slamming loads have been compared between the survival condition and transit condition with the method. The results indicate that wave slamming under survival condition is more critical than that under transit condition.Meanwhile, the wave slamming is significant to the structural strength of the brace. It should be overall considered in the strength analysis of the brace structure.
基金Project of Ministry of Housing and Urban-Rural Development of China(No.2012-K2-28)
文摘Determining initial pretension values of pre-stressed cables is one of the key problems for a steel mega frame and pre-stressed composite bracing structure.Through the mechanical analysis of the composite bracing under vertical loading,the critical factors deciding the initial pretention value were found.According to these factors,a rule for the initial pretension value was put forward.The determination equations were acquired based on the principle of force equilibrium at nodes.The numerical results indicate that the internal force disequilibrium in composite bracings resulted from symmetrical load can be eliminated only in a symmetrical way,so that initial pretention values are decided only by vertical loads.The influencing coefficient leveling method,taking into account interactions between story and story,is accurate and feasible.
基金supported by a grant from the National Natural Science Foundation of China(52125804).
文摘A magnetorheological self-centering brace(MR–SCB)has been proposed to improve the energy dissipation capability of the brace.In this paper,a 15-story MR–SCB braced frame is numerically analyzed to examine its seismic performance and resilience.The MR–SCB provides higher lateral stiffness than the buckling restrained brace and greater energy dissipation capability than the existing self-centering brace.The brace also exhibits a reliable recentering capacity.Under rare earthquakes,the maximum average residual deformation ratio of the structure is less than the 0.5%limit.Under mega earthquakes,the maximum average interstory drift ratio of the structure does not exceed the 2.0%elastoplastic limit,and its maximum average floor acceleration ratio is 1.57.The effects of mainshock and aftershock on the structural behavior are also investigated.The interstory drift and residual deformation of the structure increase with the increase of the intensity of the aftershock.Under aftershocks with the same intensity as the mainshocks,the maximum increment of the residual deformation ratio of the structure is 81.8%,and the average interstory drift ratios of the 12^(th),7^(th),and 3^(rd)stories of the structure are increased by 13.4%,9.2%and 7.5%,respectively.The strong aftershock may significantly cause increased damage to the structure,and increase its collapse risk and residual deformation.
基金This study was supported by the National Natural Science Foundation of China under Grant No.50078016Open Funding of State Key Laboratory for Disaster Reduction in Civil Engineering,China.
文摘Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity.
文摘One of the founders of structural control theory and its application in civil engineering, Professor Emeritus Tsu T. Soong, envisioned the development of the integral design of structures protected by active control devices. Most of his disciples and colleagues continuously attempted to develop procedures to achieve such integral control. In his recent papers published jointly with some of the authors of this paper, Professor Soong developed design procedures for the entire structure using a design - redesign procedure applied to elastic systems. Such a procedure was developed as an extension of other work by his disciples. This paper summarizes some recent techniques that use traditional active control algorithms to derive the most suitable (optimal, stable) control force, which could then be implemented with a combination of active, passive and semi-active devices through a simple match or more sophisticated optimal procedures. Alternative design can address the behavior of structures using Liapunov stability criteria. This paper shows a unified procedure which can be applied to both elastic and inelastic structures. Although the implementation does not always preserve the optimal criteria, it is shown that the solutions are effective and practical for design of supplemental damping, stiffness enhancement or softening, and strengthening or weakening.
文摘Expansive soils can pose tough issues to civil engineering applications. In a typical year, expansive soils can cause a greater financial loss than earthquakes, floods, hurricanes and tornadoes combined. Various means have been studied to tackle problems associated with expansive soils. The majority of the methods are based on treatment of the soils. While the methods may be effective in some cases, their limitations are also obvious: The treatment normally involves complex processes and may not be eco-friendly in the long run. In many cases, the effectiveness of the treatment is uncertain. A retaining system that maintains a constant lateral pressure is proposed, which consists of three components: the retaining sheet, the slip-force device and the bracing column. The retaining sheet bears the pressure exerted by expansive backfills and is not embedded into the soils. Placed between the retaining sheet and bracing column, the slip-force device permits displacement of the retaining sheet but keeps the force on the sheet and the bracing column constant. The governing equation of the motion of the piston in the slip-force device is derived and a numerical simulation of a practical case is conducted based on the derived governing equation. Numerical results show that as the expansive soil swell, the spring force will increase and the piston will move accordingly. When the pressure of the oil in chamber reach<span style="font-family:Verdana;"><span style="font-family:Verdana;"><span style="font-family:Verdana;">es</span></span></span><span><span><span style="font-family:;" "=""><span style="font-family:Verdana;"> the open threshold of the unidirectional relief valve, the valve will open and the spring force and the oil pressure in the chamber will keep constant. The results also show that some parameters, such as damping ratio, have very slight influences on the device behavior, say 2 × 10</span><sup><span style="font-family:Verdana;">-6</span></sup><span style="font-family:Verdana;"> or even 4.8 × 10</span><sup><span style="font-family:Verdana;">-9</span></sup><span style="font-family:Verdana;">. Theoretical and numerical studies prove the effectiveness of the proposed retaining system.</span></span></span></span>