Numerical simulation investigation on pressure loss of diffusion tank of axial main fan 被引量:3
1
作者 WANG Hai-qiao ZOU Zu-yun +1 位作者 CHEN Shi-qiang CHEN Chong-xin 《Journal of Coal Science & Engineering(China)》 2011年第4期447-449,共3页
Based on the engineering application, the angle range of rectifying airflow unit attaching diffusion tank is from 2.5° to 7.5°. In the range of average inlet velocity of 25.0 m/s to 55.0 m/s of diffusion tan... Based on the engineering application, the angle range of rectifying airflow unit attaching diffusion tank is from 2.5° to 7.5°. In the range of average inlet velocity of 25.0 m/s to 55.0 m/s of diffusion tank, numerical simulations of diffusion tank were done. The results of numerical simulations of diffusion tank are shown as follows: ③ In cases of the inlet velocity range from 25.0 m/s to 55.0 m/s, and the angle range of rectifying airflow unit from 2.5° to 7.5°, the average value of pressure losses decreases to the minimum when the angle is 4.5°.② In cases of the inlet velocity of 35.0 m/s, the pressure loss of diffusion tank decreases to the minimum when the angle of rectifying airflow unit is 5.5°. ③ As far as there are different angles of rectifying airflow unit, pressure loss increases gradually along with the addition of inlet velocity. 展开更多
关键词 diffusion tank angle of rectifying airflow unit pressure loss