To solve the difficulty of generating an ideal Bessel beam,an simplified annular transducer model is proposed to study the axial acoustic radiation force(ARF)and the corresponding negative ARF(pulling force)exerted on...To solve the difficulty of generating an ideal Bessel beam,an simplified annular transducer model is proposed to study the axial acoustic radiation force(ARF)and the corresponding negative ARF(pulling force)exerted on centered elastic spheres for acoustic-vortex(AV)beams of arbitrary orders.Based on the theory of acoustic scattering,the axial distributions of the velocity potential and the ARF for AV beams of different orders generated by the annular transducers with different physical sizes are simulated.It is proved that the pulling force can be generated by AV beams of arbitrary orders with multiple axial regions.The pulling force is more likely to exert on the sphere with a smaller k0a(product of the wave number and the radius)for the AV beam with a bigger topological charge due to the strengthened off-axis acoustic scattering.The pulling force decreases with the increase of the axial distance for the sphere with a bigger k0a.More pulling force areas with wider axial regions can be formed by AV beams using a bigger-sized annular transducer.The theoretical results demonstrate the feasibility of generating the pulling force along the axes of AV beams using the experimentally applicable circular array of planar transducers,and suggest application potentials for multi-position stable object manipulations in biomedical engineering.展开更多
In order to improve the operability and accuracy of high-intensity focused ultrasound (HIFU), an annular focused transducer, whereby a B-ultrasound probe is placed in its center, is used to realize the real time mon...In order to improve the operability and accuracy of high-intensity focused ultrasound (HIFU), an annular focused transducer, whereby a B-ultrasound probe is placed in its center, is used to realize the real time monitoring and control of the treatment. In this paper, the spheroidal beam equation (SBE) was used to calculate the sound lield by an annular focused transducer with a wide aperture angle to first derive the heat deposition and the Pennes equation was used to calculate the temperature field in multi-layer tissue. We studied the effect of different parameters on the temperature of the tissues. The result shows that the focal length has a significant influence on both maximum liver temperature rise and skin temperature rise, and both increase with the increase in the focal length. When the frequency increases, the temperature rise first undergoes a rapid increase before gradually reaching a maximum, and then finally decreasing. The temperature rise increases while the inner radius decreases or the sound pressure increases. By choosing suitable parameters, the proper temperature rise both on the target tissue and skin via an annular tbcused transducer with a wide aperture angle can be obtained.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11934009,11974187,and 11604156).
文摘To solve the difficulty of generating an ideal Bessel beam,an simplified annular transducer model is proposed to study the axial acoustic radiation force(ARF)and the corresponding negative ARF(pulling force)exerted on centered elastic spheres for acoustic-vortex(AV)beams of arbitrary orders.Based on the theory of acoustic scattering,the axial distributions of the velocity potential and the ARF for AV beams of different orders generated by the annular transducers with different physical sizes are simulated.It is proved that the pulling force can be generated by AV beams of arbitrary orders with multiple axial regions.The pulling force is more likely to exert on the sphere with a smaller k0a(product of the wave number and the radius)for the AV beam with a bigger topological charge due to the strengthened off-axis acoustic scattering.The pulling force decreases with the increase of the axial distance for the sphere with a bigger k0a.More pulling force areas with wider axial regions can be formed by AV beams using a bigger-sized annular transducer.The theoretical results demonstrate the feasibility of generating the pulling force along the axes of AV beams using the experimentally applicable circular array of planar transducers,and suggest application potentials for multi-position stable object manipulations in biomedical engineering.
基金Project supported by the National Key Research and Development Program,China(Grant No.2016YFF0203000)the National Natural Science Foundation of China(Grant Nos.11774167 and 61571222)+2 种基金the Fundamental Research Funds for the Central Universities,China(Grant No.020414380001)the State Key Laboratory of Acoustics,Chinese Academy of Sciences(Grant No.SKLA201609)AQSIQ Technology Research and Development Program,China(Grant No.2017QK125)
文摘In order to improve the operability and accuracy of high-intensity focused ultrasound (HIFU), an annular focused transducer, whereby a B-ultrasound probe is placed in its center, is used to realize the real time monitoring and control of the treatment. In this paper, the spheroidal beam equation (SBE) was used to calculate the sound lield by an annular focused transducer with a wide aperture angle to first derive the heat deposition and the Pennes equation was used to calculate the temperature field in multi-layer tissue. We studied the effect of different parameters on the temperature of the tissues. The result shows that the focal length has a significant influence on both maximum liver temperature rise and skin temperature rise, and both increase with the increase in the focal length. When the frequency increases, the temperature rise first undergoes a rapid increase before gradually reaching a maximum, and then finally decreasing. The temperature rise increases while the inner radius decreases or the sound pressure increases. By choosing suitable parameters, the proper temperature rise both on the target tissue and skin via an annular tbcused transducer with a wide aperture angle can be obtained.