The waste fiuorgypsum was modified and applied as a cement retarder. The main chemical composition and mineral structure of the waste fluorgypsum were analyzed. Scanning electron microscopy (SEM) and eight-channel m...The waste fiuorgypsum was modified and applied as a cement retarder. The main chemical composition and mineral structure of the waste fluorgypsum were analyzed. Scanning electron microscopy (SEM) and eight-channel micro-calorimeter (TAM Air) were employed to analyze the changes in morphology and study the application performance of the modified fluorgypsum, respectively. Experimental results indicate that the flexural strength and compressive strength of the modified fiuorgypsurn are roughly equal to those of the natural gypsum. The morphology of the crystal of the fiuorgypsum changes from block particle into trimetric short column. The fluorgypsum crystals stagger mutually and improve the strength of the hardened body. The modified fluorgypsum as cement retarder could delay the hydration, reduce the heat of the hydration and make the setting time, volume stability, and the S03 content of the cement meet the national standards. The modified fluorgypsum is a good substitute for the natural gypsum.展开更多
Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial l...Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial low power heat into“renewable heat”useful to enhance the efficiency of the system is essential and actual innovation in the field of worldwide environmental protection.By introducing and defining the terminology of low-potential,“renewable”,“green heat”has created a new,parallel category of research in the energy sector.Traditional co-generation systems produce heat for space heating and hot water and generate electricity.Moving to tri-generation allows growing demand for air conditioning for homes,offices and commercial spaces such as server rooms and switchboards to be met simultaneously or on a seasonal basis.Tri-generation,or combined cooling,heat and power,is the process by which some of the heat produced by a co-generation plant is used to generate chilled water for air conditioning or refrigeration.Usually an absorption chiller is linked to the plant to provide this functionality.The technical solution is related to the new efficient manner and system of simultaneous generation of heat/cold from multiple heat sources,which has not yet been known,but in practice required.New system also enables advantageous utilization of solar power in supporting of the cooling output.The innovative system can be operated also within the existing central heating distribution systems.展开更多
基金Project(21003014) supported by the National Natural Science Foundation of ChinaProject(2010FJ3167) supported by the Hunan Provincial Science and Technology Program,ChinaProject(K1104029-11) supported by the Changsha IT Project
文摘The waste fiuorgypsum was modified and applied as a cement retarder. The main chemical composition and mineral structure of the waste fluorgypsum were analyzed. Scanning electron microscopy (SEM) and eight-channel micro-calorimeter (TAM Air) were employed to analyze the changes in morphology and study the application performance of the modified fluorgypsum, respectively. Experimental results indicate that the flexural strength and compressive strength of the modified fiuorgypsurn are roughly equal to those of the natural gypsum. The morphology of the crystal of the fiuorgypsum changes from block particle into trimetric short column. The fluorgypsum crystals stagger mutually and improve the strength of the hardened body. The modified fluorgypsum as cement retarder could delay the hydration, reduce the heat of the hydration and make the setting time, volume stability, and the S03 content of the cement meet the national standards. The modified fluorgypsum is a good substitute for the natural gypsum.
文摘Introduction:The current worldwide electric power&heat&cool production has a negative impact on the environment by emissions and enormous leaks of low-potential waste heat.Transformation of unused industrial low power heat into“renewable heat”useful to enhance the efficiency of the system is essential and actual innovation in the field of worldwide environmental protection.By introducing and defining the terminology of low-potential,“renewable”,“green heat”has created a new,parallel category of research in the energy sector.Traditional co-generation systems produce heat for space heating and hot water and generate electricity.Moving to tri-generation allows growing demand for air conditioning for homes,offices and commercial spaces such as server rooms and switchboards to be met simultaneously or on a seasonal basis.Tri-generation,or combined cooling,heat and power,is the process by which some of the heat produced by a co-generation plant is used to generate chilled water for air conditioning or refrigeration.Usually an absorption chiller is linked to the plant to provide this functionality.The technical solution is related to the new efficient manner and system of simultaneous generation of heat/cold from multiple heat sources,which has not yet been known,but in practice required.New system also enables advantageous utilization of solar power in supporting of the cooling output.The innovative system can be operated also within the existing central heating distribution systems.