This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elim...This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations.展开更多
When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is...When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system.展开更多
When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and ...When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished.展开更多
This article presents the special requirements and features of the thyristor commutators of the welding current.Advantages of pulsed - arc welding are described.Specificity of the thyristor commutators op- eratio...This article presents the special requirements and features of the thyristor commutators of the welding current.Advantages of pulsed - arc welding are described.Specificity of the thyristor commutators op- eration is presented. Semiconductor converter simulation allowing to create the engineering calculating techniques are considered.展开更多
Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measur...Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measure the capacitive current of Fengxian 28 substations, and the neutral grounding modes of the 28 substations are determined based on the measured values of capacitive current.展开更多
In this paper,a passive muzzle arc control device(PMACD)of the augmented railguns is studied.By discussing its performance at different numbers of extra rails,a parameter optimization model is proposed.Through the cal...In this paper,a passive muzzle arc control device(PMACD)of the augmented railguns is studied.By discussing its performance at different numbers of extra rails,a parameter optimization model is proposed.Through the calculation model,it is found that the PMACD works well in the simple railgun,which refers to the gun that there is only one pair of rails in the inner bore.The PMACD may decrease the simple railgun’s armature peak current and muzzle arc,but affect its muzzle velocity not much.However,in the augmented railguns it has different characteristics.If the parameters of the PMACD are not selected suitable.It may increase the armature peak current and muzzle arc,but greatly decrease the velocity.The reason for this problem is that the extra rails generate a strong magnetic field in front of the armature,which induces a large current to change the armature current.It is also found that when the resistance and inductance parameters of the PMACD satisfy with the optimization formula,the PMACD can also play a good role in arc suppression in the augmented railguns.Experiments of an augmented railgun with a stainless steel PMACD are carried out to verify this optimization method.Results show that the muzzle arc is obviously controlled.This work may provide a reference for the design of the muzzle arc control device.展开更多
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren...The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced.展开更多
The model of optimization problem for Support Vector Machine(SVM) is provided, which based on the definitions of the dual norm and the distance between a point and its projection onto a given plane. The model of impro...The model of optimization problem for Support Vector Machine(SVM) is provided, which based on the definitions of the dual norm and the distance between a point and its projection onto a given plane. The model of improved Support Vector Machine based on 1-norm(1-SVM) is provided from the optimization problem, yet it is a discrete programming. With the smoothing technique and optimality knowledge, the discrete programming is changed into a continuous programming. Experimental results show that the algorithm is easy to implement and this method can select and suppress the problem features more efficiently. Illustrative examples show that the 1-SVM deal with the linear or nonlinear classification well.展开更多
基金the Natural Science Foundation of Fujian,China(No.2021J01633).
文摘This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations.
文摘When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system.
文摘When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished.
文摘This article presents the special requirements and features of the thyristor commutators of the welding current.Advantages of pulsed - arc welding are described.Specificity of the thyristor commutators op- eration is presented. Semiconductor converter simulation allowing to create the engineering calculating techniques are considered.
文摘Combined with actual situation of Fengxian power Supply Company, the neutral grounding modes of Fengxian 35 kV and 10 kV power grid are studied in the paper. The different frequencies injected method is used to measure the capacitive current of Fengxian 28 substations, and the neutral grounding modes of the 28 substations are determined based on the measured values of capacitive current.
基金acknowledge the Fundamental Research Funds for the Central Universities(Grants No 309190112102)the Natural Science Foundation of Jiangsu Province(Grants No BK20200493).
文摘In this paper,a passive muzzle arc control device(PMACD)of the augmented railguns is studied.By discussing its performance at different numbers of extra rails,a parameter optimization model is proposed.Through the calculation model,it is found that the PMACD works well in the simple railgun,which refers to the gun that there is only one pair of rails in the inner bore.The PMACD may decrease the simple railgun’s armature peak current and muzzle arc,but affect its muzzle velocity not much.However,in the augmented railguns it has different characteristics.If the parameters of the PMACD are not selected suitable.It may increase the armature peak current and muzzle arc,but greatly decrease the velocity.The reason for this problem is that the extra rails generate a strong magnetic field in front of the armature,which induces a large current to change the armature current.It is also found that when the resistance and inductance parameters of the PMACD satisfy with the optimization formula,the PMACD can also play a good role in arc suppression in the augmented railguns.Experiments of an augmented railgun with a stainless steel PMACD are carried out to verify this optimization method.Results show that the muzzle arc is obviously controlled.This work may provide a reference for the design of the muzzle arc control device.
基金The financial support from the National Natural Science Foundation of China (No. 51107143)
文摘The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced.
基金Supported Partially by National Science Foundation of China (No.10571109,60573018)Science & Technology Research Project of Shanxi Higher-Education (No.20051277)
文摘The model of optimization problem for Support Vector Machine(SVM) is provided, which based on the definitions of the dual norm and the distance between a point and its projection onto a given plane. The model of improved Support Vector Machine based on 1-norm(1-SVM) is provided from the optimization problem, yet it is a discrete programming. With the smoothing technique and optimality knowledge, the discrete programming is changed into a continuous programming. Experimental results show that the algorithm is easy to implement and this method can select and suppress the problem features more efficiently. Illustrative examples show that the 1-SVM deal with the linear or nonlinear classification well.