In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation o...In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation of CCD pixels was analyzed,and its expression was given.Then,based on the discrete expression of deformation fringes obtained after sampling,its Fourier spectrum expression was derived,resulting in an infinitely repeated"spectra island"in the frequency domain.Finally,on the basis of using a low-pass filter to remove high-order harmonic components and retaining only one fundamental frequency component,the inverse Fourier transform was used to reconstruct the signal strength.A method of reducing the sampling interval,i.e.,reducing the number of sampling points per fringe,was proposed to increase the ratio between the sampling frequency and the fundamental frequency of the grating.This was done to reconstruct the object’s surface shape more accurately under the condition of m>4.The basic principle was verified through simulation and experiment.In the simulation,the sampling intervals were 8 pixels,4 pixels,2 pixels,and 1 pixel,the maximum absolute error values obtained in the last three situations were 88.80%,38.38%,and 31.50%in the first situation,respectively,and the corresponding average absolute error values are 71.84%,43.27%,and 32.26%.It is demonstrated that the smaller the sampling interval,the better the recovery effect.Taking the same four sampling intervals in the experiment as in the simulation can also lead to the same conclusions.The simulated and experimental results show that reducing the sampling interval can improve the accuracy of object surface shape measurement and achieve better reconstruction results.展开更多
Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the pro...Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the problem with the latter is that it cannot enhance phase quality directly nor efficiently. In this paper, we present a multi-objective optimization framework for three-dimensional(3D) measurement by utilizing binary defocusing technique. Moreover, a binary patch optimization technique is used to solve the time-consuming issue of genetic algorithm. It is demonstrated that the presented technique consistently obtains significant phase performance improvement under various defocusing amounts.展开更多
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ...Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics).展开更多
This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on...This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on multiple parallel line lasers.Firstly,we establish the measurement model of the multiple parallel line lasers system,and introduce the concept that multiple base planes can help to deduce the unified formula of the measurement system and are used in simplifying the process of the calibration.Then,the constraint of the line spatial frequency,which maximizes the measurement efficiency while ensuring accuracy,is determined according to the height distribution of the object.Secondly,the simulation analyzing the variation of the systemic resolution quantitatively under the circumstance of a set of specific parameters is performed,which provides a fundamental thesis for option of the four system parameters.Thirdly,for the application of the precision measurement in the industrial field,additional profiles are acquired to improve the lateral resolution by applying a motor to scan the 3 D surface.Finally,compared with the line laser,the experimental study shows that the present method of obtaining 41220 points per frame improves the measurement efficiency.Furthermore,the accuracy and the process of the calibration are advanced in comparison with the existing multiple-line laser and the structured light makes an accuracy better than 0.22 mm at a distance of 956.02 mm.展开更多
This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes...This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics.展开更多
In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that ...In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that lie in the x-axis direction of the phase domain are given. Partial derivatives of the phase function in the x- and y-axis directions are obtained with a phase-shifting mechanism, the origin of which is analysed. Furthermore, to avoid phase unwrapping in the phase reconstruction, we derive the gradient of the phase function and perform a two-dimensional integral along the x- and y-axis directions. The reconstructed phase can be obtained directly by performing numerical integration, and thus it is of great convenience for phase reconstruction. Finally, the results of numerical simulations and practical experiments verify the correctness of the proposed method.展开更多
This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with u...This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with unique 5-element configuration</span></span><span style="white-space:normal;"><span style="font-family:;" "="">, with all five elements acting as transmitters and four elements as receivers. The receivers are designed to reduce the amount of uncertainty. As the fluid moves through this setup, four Doppler frequencies are obtained. The multi-dimensional velocity information along the measurement line can be reconstructed. The transducer has a compact geometry suitable for a wide range of applications, including narrow flow areas. The transducer’s basic frequency and sound pressure are selected and evaluated to be compatible with the application. First, to confirm the measurement ability, the measurement of the developed system in two-dimensional flow is validated by comparing it to the theoretical data. The uncertainty of measurement was within 15%. Second, the three-dimensional measurement in turbulent and swirling flow is proved experimentally to check the applicability of the proposed technique.</span></span>展开更多
Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital wer...Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the展开更多
The recent development of synthesis processes to assemble graphene sheets into porous three-dimensional (3D)macroscopic structures are reviewed, including our efforts on 3D graphene structures. Mechanisms for buildi...The recent development of synthesis processes to assemble graphene sheets into porous three-dimensional (3D)macroscopic structures are reviewed, including our efforts on 3D graphene structures. Mechanisms for building 3D graphene architectures and their composite materials are also summarized. The functional systems based on 3D graphene architectures provide a significant enhancement in the efficacy due to their unique structures and properties.展开更多
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat...A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma.展开更多
A new type of implantable drug delivery devices ( DDD ) with complicated architectures were fubricated by three-dimensional printing technique, employing levofloxacin (LVFX) as a model drug. Processing parameters...A new type of implantable drug delivery devices ( DDD ) with complicated architectures were fubricated by three-dimensional printing technique, employing levofloxacin (LVFX) as a model drug. Processing parameters were optimized in riew of the layer thickness, spucing between printed lines, flow rate of liquid binder and the fast axis speed. The prepared DDD prototype consists of a double-layer structure, of which the upper region is a reservoir system and the lower region is a matrix one. The in vitro release test revealed that LVFX was released in a dual-puse pattern. This DDD may present a new strategy for the prophylaxis and treatment of diseases such as bone infection in the near future.展开更多
Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproduc...Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain.展开更多
A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch...A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch protector for neonates, particularly whoa they are exposed to bright lights such as phototherapy light. Measurements obtained by the system are evaluated and validated against data obtained from optical scanning. Results show that the photogrammetric system meets the requirements of measuring accuracy and safety for neonate in the neonatal units.展开更多
The purpose of this study was to show the benefit of visualizing a tree-dimensional (3D) image of the tongue’s muscle structure, which until now has been regarded as fully understood. Until now, no suitable 3D observ...The purpose of this study was to show the benefit of visualizing a tree-dimensional (3D) image of the tongue’s muscle structure, which until now has been regarded as fully understood. Until now, no suitable 3D observation methods have been developed for soft tissue, such as the tongue, using?histological magnification. For this purpose, this study used a micro-computed tomographic method (micro-CT) and image processing after the fixation, decalcification, and dehydration of a mouse tongue. Results: 3D rendered images of tongue muscles obtained by micro-CT showed every muscle and their relationships to each other. The superior longitudinal and the hyoglossus muscles of the tongue made up one group, while the inferior longitudinal and the styloglossus muscles of the tongue made up another. The boundary of the two muscles in each group was difficult to distinguish. On the other hand, what appear to be newly described muscles were identified. These results indicate that our micro-CT method is beneficial and that classical knowledge of tongue muscles derived from two-dimensional (2D) images does not fully describe the actual complexity of the tongue muscles. In our opinion, 3D rendered images mixed with raw structure can provide a more in-depth picture of the tongue from an integrated as well as an analytical perspective.展开更多
The evolution of the current network has challenges of programmability, maintainability and manageability, due to network ossification. This challenge led to the concept of software-defined networking (SDN), to decoup...The evolution of the current network has challenges of programmability, maintainability and manageability, due to network ossification. This challenge led to the concept of software-defined networking (SDN), to decouple the control system from the infrastructure plane caused by ossification. The innovation created a problem with controller placement. That is how to effectively place controllers within a network topology to manage the network of data plane devices from the control plane. The study was designed to empirically evaluate and compare the functionalities of two controller placement algorithms: the POCO and MOCO. The methodology adopted in the study is the explorative and comparative investigation techniques. The study evaluated the performances of the Pareto optimal combination (POCO) and multi-objective combination (MOCO) algorithms in relation to calibrated positions of the controller within a software-defined network. The network environment and measurement metrics were held constant for both the POCO and MOCO models during the evaluation. The strengths and weaknesses of the POCO and MOCO models were justified. The results showed that the latencies of the two algorithms in relation to the GoodNet network are 3100 ms and 2500 ms for POCO and MOCO respectively. In Switch to Controller Average Case latency, the performance gives 2598 ms and 2769 ms for POCO and MOCO respectively. In Worst Case Switch to Controller latency, the performance shows 2776 ms and 2987 ms for POCO and MOCO respectively. The latencies of the two algorithms evaluated in relation to the Savvis network, compared as follows: 2912 ms and 2784 ms for POCO and MOCO respectively in Switch to Controller Average Case latency, 3129 ms and 3017 ms for POCO and MOCO respectively in Worst Case Switch to Controller latency, 2789 ms and 2693 ms for POCO and MOCO respectively in Average Case Controller to Controller latency, and 2873 ms and 2756 ms for POCO and MOCO in Worst Case Switch to Controller latency respectively. The latencies of the two algorithms evaluated in relation to the AARNet, network compared as follows: 2473 ms and 2129 ms for POCO and MOCO respectively, in Switch to Controller Average Case latency, 2198 ms and 2268 ms for POCO and MOCO respectively, in Worst Case Switch to Controller latency, 2598 ms and 2471 ms for POCO and MOCO respectively, in Average Case Controller to Controller latency, 2689 ms and 2814 ms for POCO and MOCO respectively Worst Case Controller to Controller latency. The Average Case and Worst-Case latencies for Switch to Controller and Controller to Controller are minimal, and favourable to the POCO model as against the MOCO model when evaluated in the Goodnet, Savvis, and the Aanet networks. This simply indicates that the POCO model has a speed advantage as against the MOCO model, which appears to be more resilient than the POCO model.展开更多
Background: The suitability of micro-computed tomography (CT) for soft tissue applications has been well documented. Although the application of micro-CT to the three dimensional (3D) structure of the tongue muscle ha...Background: The suitability of micro-computed tomography (CT) for soft tissue applications has been well documented. Although the application of micro-CT to the three dimensional (3D) structure of the tongue muscle has been reported, a 3D rendering and/or a schematic view of the tongue muscle has yet to be published. Material and Method: First, muse tongues were fixed and decalcified, and then the vertical muscle (Ve), the transverse muscle (Tr), and/or the genioglossus muscle of the mouse tongue (Ge) were analyzed using micro-CT and are shown in this report in rendered images and pattern diagrams. Results: 1) The Tr is classified into three parts: the first part extends from the middle to the apical part of the tongue;the second part is strongly connected to the superior longitudinal muscles of the tongue (Lo);the third part fans out from the middle to the root of the tongue. 2) The Ve is classified into two main groups: the first group joins the dorsal and the lateral parts of the tongue;the second group joins the dorsal part and the floor of the tongue. 3) Ge is classified into four parts: three parts comprise the Ge apical and middle parts of the tongue, with one part in the inferior longitudinal muscles of the tongue, one joining the lingual septum of the tongue (LS), and the other joining the sub-surface of the dorsal part of the Lo. The remaining Ge exits in a fan-like manner through the root of the tongue and then joins the Tr.展开更多
BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacia...BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults.展开更多
Taking contents of Italian Renaissance gardens in the course Foreign Landscape Architecture History as an example,this paper introduces case teaching method and analyzes application of three-dimensional graphic analys...Taking contents of Italian Renaissance gardens in the course Foreign Landscape Architecture History as an example,this paper introduces case teaching method and analyzes application of three-dimensional graphic analysis method in case teaching in detail,aiming at typical cases of Italian Renaissance gardens,namely,Villa Medici,Fiesole and Villa d’Este,Tivoli.Three-dimensional graphic analysis can help students form intuitive feeling of terrain and space,further understand the typical gardening techniques of foreign gardens,so as to improve the teaching effect of landscape architecture history course.展开更多
As a promising technology to completely transform how we architect, deploy, operate and manage various networks, software-based Network Function Virtualization(NFV) enables hardware-independent, flexible, fast and eff...As a promising technology to completely transform how we architect, deploy, operate and manage various networks, software-based Network Function Virtualization(NFV) enables hardware-independent, flexible, fast and efficient network service provision. With the increasing popularity of NFV paradigm, the Internet has also transformed to be a hybrid environment where NFV-based network entities coexist with traditional network devices. To facilitate our understanding, design, evaluate and manage of such novel network environment, there is a great need for a new NFV-compatible network measurement system which is still in absent so far. To bridge this gap, a system, named Software Defined Network Measurement System(SDNMS), is presented in this paper. Firstly, the architecture of SDNMS is proposed. In this architecture, a formal method to describe the working mode of the network measurement is defined. This method can also be utilized to generate a network measurement middle box(NMMB) in a specific location of the NFV network according to the customized description file, and to flexibly deploy the network measurement function. Secondly, the technology of virtual network measurement function(VNMF) combined with LXC is studied to form NMMB function. Thirdly, a control method is presented to control the start, stop, and update NMMB to form a specific network measurement system function. Finally, a prototype of SDNMS with network monitoring function to monitor network performance anomalies and locate faults is introduced. Experimental results have shown that SDNMS architecture and related technologies are feasible and effective to deploy and control network measurement functions in NFV networks. We hope SDNMS could provide a new method for practitioners to conduct network management and research at the age of NFV.展开更多
文摘In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation of CCD pixels was analyzed,and its expression was given.Then,based on the discrete expression of deformation fringes obtained after sampling,its Fourier spectrum expression was derived,resulting in an infinitely repeated"spectra island"in the frequency domain.Finally,on the basis of using a low-pass filter to remove high-order harmonic components and retaining only one fundamental frequency component,the inverse Fourier transform was used to reconstruct the signal strength.A method of reducing the sampling interval,i.e.,reducing the number of sampling points per fringe,was proposed to increase the ratio between the sampling frequency and the fundamental frequency of the grating.This was done to reconstruct the object’s surface shape more accurately under the condition of m>4.The basic principle was verified through simulation and experiment.In the simulation,the sampling intervals were 8 pixels,4 pixels,2 pixels,and 1 pixel,the maximum absolute error values obtained in the last three situations were 88.80%,38.38%,and 31.50%in the first situation,respectively,and the corresponding average absolute error values are 71.84%,43.27%,and 32.26%.It is demonstrated that the smaller the sampling interval,the better the recovery effect.Taking the same four sampling intervals in the experiment as in the simulation can also lead to the same conclusions.The simulated and experimental results show that reducing the sampling interval can improve the accuracy of object surface shape measurement and achieve better reconstruction results.
基金Project supported by the Zhejiang Provincial Welfare Technology Applied Research Project,China(Grant No.2017C31080)
文摘Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the problem with the latter is that it cannot enhance phase quality directly nor efficiently. In this paper, we present a multi-objective optimization framework for three-dimensional(3D) measurement by utilizing binary defocusing technique. Moreover, a binary patch optimization technique is used to solve the time-consuming issue of genetic algorithm. It is demonstrated that the presented technique consistently obtains significant phase performance improvement under various defocusing amounts.
基金The National Natural Science Foundation of China under contract Nos 41706021 and 41976188。
文摘Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics).
文摘This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on multiple parallel line lasers.Firstly,we establish the measurement model of the multiple parallel line lasers system,and introduce the concept that multiple base planes can help to deduce the unified formula of the measurement system and are used in simplifying the process of the calibration.Then,the constraint of the line spatial frequency,which maximizes the measurement efficiency while ensuring accuracy,is determined according to the height distribution of the object.Secondly,the simulation analyzing the variation of the systemic resolution quantitatively under the circumstance of a set of specific parameters is performed,which provides a fundamental thesis for option of the four system parameters.Thirdly,for the application of the precision measurement in the industrial field,additional profiles are acquired to improve the lateral resolution by applying a motor to scan the 3 D surface.Finally,compared with the line laser,the experimental study shows that the present method of obtaining 41220 points per frame improves the measurement efficiency.Furthermore,the accuracy and the process of the calibration are advanced in comparison with the existing multiple-line laser and the structured light makes an accuracy better than 0.22 mm at a distance of 956.02 mm.
基金National Natural Science Foundation of China (50275139) Natural Science Foundation of Zhejiang (01388-G)
文摘This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics.
基金Project supported by the National Natural Science Foundation of China (Grant No. 61144006)
文摘In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that lie in the x-axis direction of the phase domain are given. Partial derivatives of the phase function in the x- and y-axis directions are obtained with a phase-shifting mechanism, the origin of which is analysed. Furthermore, to avoid phase unwrapping in the phase reconstruction, we derive the gradient of the phase function and perform a two-dimensional integral along the x- and y-axis directions. The reconstructed phase can be obtained directly by performing numerical integration, and thus it is of great convenience for phase reconstruction. Finally, the results of numerical simulations and practical experiments verify the correctness of the proposed method.
文摘This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with unique 5-element configuration</span></span><span style="white-space:normal;"><span style="font-family:;" "="">, with all five elements acting as transmitters and four elements as receivers. The receivers are designed to reduce the amount of uncertainty. As the fluid moves through this setup, four Doppler frequencies are obtained. The multi-dimensional velocity information along the measurement line can be reconstructed. The transducer has a compact geometry suitable for a wide range of applications, including narrow flow areas. The transducer’s basic frequency and sound pressure are selected and evaluated to be compatible with the application. First, to confirm the measurement ability, the measurement of the developed system in two-dimensional flow is validated by comparing it to the theoretical data. The uncertainty of measurement was within 15%. Second, the three-dimensional measurement in turbulent and swirling flow is proved experimentally to check the applicability of the proposed technique.</span></span>
文摘Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the
基金supported by the National Natural Science Foundation of China (Grant Nos. 11004230, 51172273, 11290161, and 11027402)the National Basic Research Program of China (Grant Nos. 2012CB933003 and 2013CB932603)the Chinese Academy of Sciences (Grant No. KJCX2-YW-W35)
文摘The recent development of synthesis processes to assemble graphene sheets into porous three-dimensional (3D)macroscopic structures are reviewed, including our efforts on 3D graphene structures. Mechanisms for building 3D graphene architectures and their composite materials are also summarized. The functional systems based on 3D graphene architectures provide a significant enhancement in the efficacy due to their unique structures and properties.
基金supported by the National Magnetic Confinement Fusion Energy R&D Program of China(Nos.2018YFE0309100 and 2019YFE03010004)National Natural Science Foundation of China(No.51821005)。
文摘A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma.
文摘A new type of implantable drug delivery devices ( DDD ) with complicated architectures were fubricated by three-dimensional printing technique, employing levofloxacin (LVFX) as a model drug. Processing parameters were optimized in riew of the layer thickness, spucing between printed lines, flow rate of liquid binder and the fast axis speed. The prepared DDD prototype consists of a double-layer structure, of which the upper region is a reservoir system and the lower region is a matrix one. The in vitro release test revealed that LVFX was released in a dual-puse pattern. This DDD may present a new strategy for the prophylaxis and treatment of diseases such as bone infection in the near future.
文摘Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain.
基金Earmarked Research Grant (Hong Kong)(No.POLYU 5299/04E)
文摘A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch protector for neonates, particularly whoa they are exposed to bright lights such as phototherapy light. Measurements obtained by the system are evaluated and validated against data obtained from optical scanning. Results show that the photogrammetric system meets the requirements of measuring accuracy and safety for neonate in the neonatal units.
文摘The purpose of this study was to show the benefit of visualizing a tree-dimensional (3D) image of the tongue’s muscle structure, which until now has been regarded as fully understood. Until now, no suitable 3D observation methods have been developed for soft tissue, such as the tongue, using?histological magnification. For this purpose, this study used a micro-computed tomographic method (micro-CT) and image processing after the fixation, decalcification, and dehydration of a mouse tongue. Results: 3D rendered images of tongue muscles obtained by micro-CT showed every muscle and their relationships to each other. The superior longitudinal and the hyoglossus muscles of the tongue made up one group, while the inferior longitudinal and the styloglossus muscles of the tongue made up another. The boundary of the two muscles in each group was difficult to distinguish. On the other hand, what appear to be newly described muscles were identified. These results indicate that our micro-CT method is beneficial and that classical knowledge of tongue muscles derived from two-dimensional (2D) images does not fully describe the actual complexity of the tongue muscles. In our opinion, 3D rendered images mixed with raw structure can provide a more in-depth picture of the tongue from an integrated as well as an analytical perspective.
文摘The evolution of the current network has challenges of programmability, maintainability and manageability, due to network ossification. This challenge led to the concept of software-defined networking (SDN), to decouple the control system from the infrastructure plane caused by ossification. The innovation created a problem with controller placement. That is how to effectively place controllers within a network topology to manage the network of data plane devices from the control plane. The study was designed to empirically evaluate and compare the functionalities of two controller placement algorithms: the POCO and MOCO. The methodology adopted in the study is the explorative and comparative investigation techniques. The study evaluated the performances of the Pareto optimal combination (POCO) and multi-objective combination (MOCO) algorithms in relation to calibrated positions of the controller within a software-defined network. The network environment and measurement metrics were held constant for both the POCO and MOCO models during the evaluation. The strengths and weaknesses of the POCO and MOCO models were justified. The results showed that the latencies of the two algorithms in relation to the GoodNet network are 3100 ms and 2500 ms for POCO and MOCO respectively. In Switch to Controller Average Case latency, the performance gives 2598 ms and 2769 ms for POCO and MOCO respectively. In Worst Case Switch to Controller latency, the performance shows 2776 ms and 2987 ms for POCO and MOCO respectively. The latencies of the two algorithms evaluated in relation to the Savvis network, compared as follows: 2912 ms and 2784 ms for POCO and MOCO respectively in Switch to Controller Average Case latency, 3129 ms and 3017 ms for POCO and MOCO respectively in Worst Case Switch to Controller latency, 2789 ms and 2693 ms for POCO and MOCO respectively in Average Case Controller to Controller latency, and 2873 ms and 2756 ms for POCO and MOCO in Worst Case Switch to Controller latency respectively. The latencies of the two algorithms evaluated in relation to the AARNet, network compared as follows: 2473 ms and 2129 ms for POCO and MOCO respectively, in Switch to Controller Average Case latency, 2198 ms and 2268 ms for POCO and MOCO respectively, in Worst Case Switch to Controller latency, 2598 ms and 2471 ms for POCO and MOCO respectively, in Average Case Controller to Controller latency, 2689 ms and 2814 ms for POCO and MOCO respectively Worst Case Controller to Controller latency. The Average Case and Worst-Case latencies for Switch to Controller and Controller to Controller are minimal, and favourable to the POCO model as against the MOCO model when evaluated in the Goodnet, Savvis, and the Aanet networks. This simply indicates that the POCO model has a speed advantage as against the MOCO model, which appears to be more resilient than the POCO model.
文摘Background: The suitability of micro-computed tomography (CT) for soft tissue applications has been well documented. Although the application of micro-CT to the three dimensional (3D) structure of the tongue muscle has been reported, a 3D rendering and/or a schematic view of the tongue muscle has yet to be published. Material and Method: First, muse tongues were fixed and decalcified, and then the vertical muscle (Ve), the transverse muscle (Tr), and/or the genioglossus muscle of the mouse tongue (Ge) were analyzed using micro-CT and are shown in this report in rendered images and pattern diagrams. Results: 1) The Tr is classified into three parts: the first part extends from the middle to the apical part of the tongue;the second part is strongly connected to the superior longitudinal muscles of the tongue (Lo);the third part fans out from the middle to the root of the tongue. 2) The Ve is classified into two main groups: the first group joins the dorsal and the lateral parts of the tongue;the second group joins the dorsal part and the floor of the tongue. 3) Ge is classified into four parts: three parts comprise the Ge apical and middle parts of the tongue, with one part in the inferior longitudinal muscles of the tongue, one joining the lingual septum of the tongue (LS), and the other joining the sub-surface of the dorsal part of the Lo. The remaining Ge exits in a fan-like manner through the root of the tongue and then joins the Tr.
基金a grant fromTackle Key Problems in Sci-ence and Technology of FoshanCity, No. 200505075
文摘BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults.
基金Sponsored by Beijing Natural Science Foundation (8202017)。
文摘Taking contents of Italian Renaissance gardens in the course Foreign Landscape Architecture History as an example,this paper introduces case teaching method and analyzes application of three-dimensional graphic analysis method in case teaching in detail,aiming at typical cases of Italian Renaissance gardens,namely,Villa Medici,Fiesole and Villa d’Este,Tivoli.Three-dimensional graphic analysis can help students form intuitive feeling of terrain and space,further understand the typical gardening techniques of foreign gardens,so as to improve the teaching effect of landscape architecture history course.
基金supported by National Natural Science Foundation of China (No. 61772271, 61379149)
文摘As a promising technology to completely transform how we architect, deploy, operate and manage various networks, software-based Network Function Virtualization(NFV) enables hardware-independent, flexible, fast and efficient network service provision. With the increasing popularity of NFV paradigm, the Internet has also transformed to be a hybrid environment where NFV-based network entities coexist with traditional network devices. To facilitate our understanding, design, evaluate and manage of such novel network environment, there is a great need for a new NFV-compatible network measurement system which is still in absent so far. To bridge this gap, a system, named Software Defined Network Measurement System(SDNMS), is presented in this paper. Firstly, the architecture of SDNMS is proposed. In this architecture, a formal method to describe the working mode of the network measurement is defined. This method can also be utilized to generate a network measurement middle box(NMMB) in a specific location of the NFV network according to the customized description file, and to flexibly deploy the network measurement function. Secondly, the technology of virtual network measurement function(VNMF) combined with LXC is studied to form NMMB function. Thirdly, a control method is presented to control the start, stop, and update NMMB to form a specific network measurement system function. Finally, a prototype of SDNMS with network monitoring function to monitor network performance anomalies and locate faults is introduced. Experimental results have shown that SDNMS architecture and related technologies are feasible and effective to deploy and control network measurement functions in NFV networks. We hope SDNMS could provide a new method for practitioners to conduct network management and research at the age of NFV.