期刊文献+
共找到321篇文章
< 1 2 17 >
每页显示 20 50 100
Evaluation of Atomic Fluorescence Spectrometry for Determination of Mercury Using a Low-Powered Argon Microwave Plasma Torch (MPT)
1
作者 Duan Yixiang, Kong Xiangxing, Zhang Hanqi, Liu Jun Jin Qinhan (Department of Chemistry, Jilin University, Changchun) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1991年第1期59-61,共3页
The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectro... The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectrometry (AES) and atomic absorption spectrometry (AAS), and a great success was achieved for both techniques. More 展开更多
关键词 atomic fluorescence spectrometry Argon microwave torch determination of mercury
下载PDF
氢化物发生-原子荧光光谱法(HG-AFS)测达里诺尔湖流域底泥样硒
2
作者 薛舒文 苏丹 +2 位作者 张嘉璇 张营 徐苏男 《科技创新与应用》 2024年第15期83-86,共4页
氢化物发生-原子荧光光谱法(HG-AFS)是测定硒(Selenium,Se)的理想方法,能精确测定水样和含水地球化学样品(底泥)中Se的含量。由于达里湖底泥中Se含量相对较低,有机质的还原状态较高,在测量Se含量时往往因为过于复杂且低于仪器检出限而... 氢化物发生-原子荧光光谱法(HG-AFS)是测定硒(Selenium,Se)的理想方法,能精确测定水样和含水地球化学样品(底泥)中Se的含量。由于达里湖底泥中Se含量相对较低,有机质的还原状态较高,在测量Se含量时往往因为过于复杂且低于仪器检出限而不能被检测到有效值。该文应用HG-AFS测定达里诺尔湖底泥中Se的含量,使用微波消解石墨赶酸作为前处理方法,并使用HG-AFS进行Se含量的测试,采用此法测定底泥中Se元素具有快速、准确、重现性好,被确定为一种快速可靠的对底泥样品Se含量进行测定的方法。 展开更多
关键词 湖泊底泥 氢化物发生-原子荧光光谱法 微波消解 测定
下载PDF
基于AFS和ICP-MS测定婴幼儿配方乳粉中硒含量的关键技术探讨
3
作者 严睿 李清清 《中国食物与营养》 2024年第7期34-38,共5页
目的:探讨采用原子荧光光谱(AFS)和电感耦合等离子体质谱(ICP-MS)技术对婴幼儿配方乳粉中的硒含量进行测定,分析方法原理、检测模式以及定量方式等关键技术点对检测结果准确性以及造成结果差异的影响及原因。方法:样品经微波消解后,分... 目的:探讨采用原子荧光光谱(AFS)和电感耦合等离子体质谱(ICP-MS)技术对婴幼儿配方乳粉中的硒含量进行测定,分析方法原理、检测模式以及定量方式等关键技术点对检测结果准确性以及造成结果差异的影响及原因。方法:样品经微波消解后,分别使用原子荧光光谱外标法和电感耦合等离子体质谱法的高灵敏度模式、高基体模式及标准加入法对婴幼儿配方乳粉中的硒进行测定。结果:原子荧光光谱标准曲线法和ICP-MS标准加入法定量结果与质控样品中位值比较接近,ICP-MS采用标准曲线法定量时,使用高灵敏度模式和高基体模式的测定结果均比质控中位值高。结论:当使用原子荧光光谱仪外标法和电感耦合等离子质谱仪标准加入法定量时,可获得较为可靠的结果。 展开更多
关键词 原子荧光光谱 电感耦合等离子体质谱 婴幼儿配方乳粉
下载PDF
HPLC-AFS法测定水产品中4种砷形态 被引量:1
4
作者 刘正华 李忠海 《食品与机械》 CSCD 北大核心 2023年第8期66-70,共5页
目的:研究建立水产品中一甲基砷酸(MMA)、二甲基砷酸(DMA)、As(Ⅲ)和As(Ⅴ)的超声辅助提取—高效液相色谱—原子荧光光谱分析方法。方法:样品采用甲醇—水(V_(甲醇)∶V_(水)=1∶1)溶液超声提取,15 mmol/L磷酸氢二铵溶液(pH 6.0)为流动相... 目的:研究建立水产品中一甲基砷酸(MMA)、二甲基砷酸(DMA)、As(Ⅲ)和As(Ⅴ)的超声辅助提取—高效液相色谱—原子荧光光谱分析方法。方法:样品采用甲醇—水(V_(甲醇)∶V_(水)=1∶1)溶液超声提取,15 mmol/L磷酸氢二铵溶液(pH 6.0)为流动相,经PRP-X100阴离子交换柱分离,原子荧光光谱分析方法测定。结果:在优化试验条件下,MMA、DMA、As(Ⅲ)、As(Ⅴ)4种砷形态化合物在0~100μg/mL的质量浓度范围内线性关系良好,相关系数均在0.998以上,检出限分别为0.82,0.94,1.10,0.78μg/L,相对标准偏差为0.8%~3.7%,加标回收率为86.0%~110.0%。结论:该方法简便,准确度、灵敏度高且试剂耗材费用低,适用于水产品中砷的形态分析。 展开更多
关键词 高效液相色谱—原子荧光光谱法(HPLC-afs) 水产品 形态分析
下载PDF
LC-AFS法测定朱砂中二价汞的含量 被引量:1
5
作者 赖利平 杨跃龙 《中医药导报》 2023年第5期58-60,75,共4页
目的:建立朱砂中二价汞的含量测定方法。方法:采用LC-AFS法进行测定,色谱柱为Angel C18(5μm,150 mm×4.6 mm);流动相为甲醇-0.04 mol/L乙酸铵(含0.1%L-半胱氨酸)(3∶97);流速:1.0 mL/min;柱温:40℃;检测器:原子荧光光谱仪。结果:... 目的:建立朱砂中二价汞的含量测定方法。方法:采用LC-AFS法进行测定,色谱柱为Angel C18(5μm,150 mm×4.6 mm);流动相为甲醇-0.04 mol/L乙酸铵(含0.1%L-半胱氨酸)(3∶97);流速:1.0 mL/min;柱温:40℃;检测器:原子荧光光谱仪。结果:朱砂中二价汞的线性范围分别为0.5~50.0 ng/mL,线性方程为Y=310.431X+11.8326(r=0.9998,n=9)。结论:该方法具有可操作性强、精密度高、重现性好等优点,符合2020年版《中华人民共和国药典》9101分析方法指导原则要求,可用于朱砂中二价汞的的含量测定。 展开更多
关键词 液相色谱-原子荧光光谱法 朱砂 二价汞 含量测定
下载PDF
微波消解HG-AFS法测定小麦中硒含量的研究 被引量:18
6
作者 赵锁劳 段敏 +2 位作者 孙新涛 王波 温瑞云 《麦类作物学报》 CAS CSCD 2004年第1期66-69,共4页
为了探讨小麦中硒含量的快速测定方法,本文考察了酸消解体系、微波功率、消解时间、酸用量等因素对利用微波消解HG—AFS法测定小麦中硒含量结果的影响,优选出了仪器的最佳工作条件,并以最佳样品消解条件和仪器工作条件测定5种小麦样品... 为了探讨小麦中硒含量的快速测定方法,本文考察了酸消解体系、微波功率、消解时间、酸用量等因素对利用微波消解HG—AFS法测定小麦中硒含量结果的影响,优选出了仪器的最佳工作条件,并以最佳样品消解条件和仪器工作条件测定5种小麦样品和国家小麦标准物质(GBW08503)中的硒含量。结果表明,小麦标准物质中硒的测定值与标准值相吻合,5种小麦样品中硒的相对标准偏差在5.44%~8.21%之间,本法的检出限为0.052ng·ml-1,浓度在0~200ng·ml-1范围内呈良好的线性关系,且具有操作简便、快速、灵敏度高、污染小等特点。 展开更多
关键词 小麦 含量测定 微波消解 HG-afs 原子荧光 质量检验
下载PDF
高效液相色谱氢化物发生原子荧光(HPLC-HG-AFS)联用技术检测海藻食品中无机砷 被引量:40
7
作者 尚德荣 宁劲松 +4 位作者 赵艳芳 翟毓秀 郭莹莹 王军 盛晓风 《水产学报》 CAS CSCD 北大核心 2010年第1期132-138,共7页
海藻食品中无机砷的含量是水产品质量检验中主要的安全卫生指标。实验采用高效液相色谱氢化物发生原子荧光联用技术(HPLC-HG-AFS)对海藻食品中无机砷的检测进行了研究。通过实验优化了提取剂、提取时间及其仪器条件,建立了HPLC-HG-AFS... 海藻食品中无机砷的含量是水产品质量检验中主要的安全卫生指标。实验采用高效液相色谱氢化物发生原子荧光联用技术(HPLC-HG-AFS)对海藻食品中无机砷的检测进行了研究。通过实验优化了提取剂、提取时间及其仪器条件,建立了HPLC-HG-AFS联用技术检测海藻食品中无机砷含量的方法。用1.2mol/LHCl在70℃水浴下提取1h,用过氧化氢(H2O2)氧化;pH6.0的15mmol/L(NH4)2HPO4溶液为流动相,HPLC-HG-AFS上机分析。样品加标量在0.10mg/kg和1.00mg/kg时的平均回收率均在92%以上,相对标准偏差均低于4%,方法精密度较高。研究结果表明,该方法测定海藻中的无机砷较为准确、可靠,为制定农业行业标准海藻食品中无机砷的测定,提供技术支持。 展开更多
关键词 高效液相色谱 氢化物发生原子荧光 海藻 无机砷
下载PDF
抽风口与烟道间距对AFS-930型原子荧光光度计测定砷、汞的影响 被引量:7
8
作者 尹雪斌 姚春霞 +2 位作者 骆永明 宋静 钱薇 《分析试验室》 CAS CSCD 北大核心 2006年第10期119-122,共4页
为了减少室内有毒氢化物的排放,同时保证测试结果的准确可靠,本文利用原子荧光光度计以As为例在实验的基础上,适当缩短了仪器烟道距上端与抽风机抽风口的距离(h)。该调节对砷测定的影响表现在,h〈10cm时,砷(As)荧光值显著降低... 为了减少室内有毒氢化物的排放,同时保证测试结果的准确可靠,本文利用原子荧光光度计以As为例在实验的基础上,适当缩短了仪器烟道距上端与抽风机抽风口的距离(h)。该调节对砷测定的影响表现在,h〈10cm时,砷(As)荧光值显著降低,10.00μg/L(As)荧光值由1200左右降低到500~1100,同时,系列标准的浓度-荧光值线性变差,相关系数(r^2)一般〈0.999,特别是其积分曲线不平滑;只有h≥10cm,测试As标准系列时荧光值正常、积分曲线平滑,并且浓度-荧光值相关系数(r^2)〉0.999。将仪器烟道距抽风口的距离h设定为10cm,在这一优化条件下,利用HNO3和HClO4体系(V(HNO3):V(HClO4)=6:1)中温消解的方法,测试了5个土壤国家标准样品和2个生物国家标准样品中As和Hg量,结果均落在参考值范围内。 展开更多
关键词 氢化物发生 原子荧光光谱法 气流 烟道高度
下载PDF
关于降低AFS-930型原子荧光光度计汞检出限的方法研究 被引量:7
9
作者 尹雪斌 陆晓奇 +5 位作者 姚春霞 宋静 钱薇 骆永明 梁有庆 孙立广 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2009年第5期1431-1433,共3页
氢化物发生-原子荧光光谱法(HG-AFS)是测试环境样品汞(Hg)的高灵敏度方法,但是为了适应污染物形态分析的需要,其灵敏度需要作进一步的提升和改善。通过提高光电倍增管负高压至280V和空心阴极灯的灯电流至30mA,原子化器高度设为10mm,并降... 氢化物发生-原子荧光光谱法(HG-AFS)是测试环境样品汞(Hg)的高灵敏度方法,但是为了适应污染物形态分析的需要,其灵敏度需要作进一步的提升和改善。通过提高光电倍增管负高压至280V和空心阴极灯的灯电流至30mA,原子化器高度设为10mm,并降低KBH4溶液到0.5%(KOH0.2%)等调整措施大大改善了仪器对Hg的灵敏度,仪器检出限从原来的8ng.L-1降至2ng.L-1(n=6)。在优化的条件下,可以获得线性良好的0~10ng.L-1浓度Hg标准曲线,能够实现对Hg浓度约为4ng.L-1的水溶液的准确测定,其测试相对标准偏差<5%;选用低吸附的聚四氟乙烯器皿和优级纯以上级别试剂可将仪器的检出限降低为1ng.L-1(n=10),使Hg的灵敏度得到进一步提升。 展开更多
关键词 氢化物发生-原子荧光光谱法 检出限 afs-930
下载PDF
卷烟滤嘴材料中汞、砷的HG-AFS测定 被引量:8
10
作者 王艳 姚孝元 +6 位作者 李栋 金鑫 李青常 孙波 韩云辉 范黎 戚其平 《烟草科技》 EI CAS 北大核心 2007年第9期41-45,共5页
采用硝酸-过氧化氢常压加热消解或微波消解和氢化物-原子荧光光谱法测定了接装纸、成型纸、醋纤丝束、聚丙烯丝束、三醋酸甘油酯、聚丙烯丝束胶粘剂、白乳胶、热熔胶等8种卷烟滤嘴材料195个样品中的汞、砷。结果显示:①汞、砷的检出限、... 采用硝酸-过氧化氢常压加热消解或微波消解和氢化物-原子荧光光谱法测定了接装纸、成型纸、醋纤丝束、聚丙烯丝束、三醋酸甘油酯、聚丙烯丝束胶粘剂、白乳胶、热熔胶等8种卷烟滤嘴材料195个样品中的汞、砷。结果显示:①汞、砷的检出限、RSD和平均回收率分别为0.1和1ng/mL、1.14%~5.31%和2.83%~6.37%、93.58%~101.5%和95.58%~102.3%;②这些卷烟滤嘴材料中的汞、砷含量范围分别为0.002~0.051mg/kg和0.025~0.651mg/kg。该方法适用于卷烟滤嘴材料中汞、砷的测定。 展开更多
关键词 滤嘴 卷烟材料 氢化物-原子荧光光谱法
下载PDF
Novel Method for Indirect Determination of Iodine in Marine Products by Atomic Fluorescence Spectrometry 被引量:1
11
作者 LU Jian-ping TAN Fang-wei +1 位作者 TANG Qiong JIANG Tian-cheng 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2013年第1期26-29,共4页
A method for the determination of iodine based upon compound H2HgI4, formed between I- and Hg1+ in nitric acid and extracted in methyl isobutyl ketone(MIBK), was developed via atomic fluorescence spectrometry(AFS... A method for the determination of iodine based upon compound H2HgI4, formed between I- and Hg1+ in nitric acid and extracted in methyl isobutyl ketone(MIBK), was developed via atomic fluorescence spectrometry(AFS). After the compound is reduced with potassium borohydrid(KBH4), the resultant mercury vapor was injected into the instrument and iodine was, therefore, indirectly determined. Experimental parameters such as the conditions of extraction reagents, aqueous phase acidity, elemental mercury diffusion temperature in a vial and other factors were investigated and optimized. Under the optimum experimental conditions, this method shows a detection limit of 0.038μg/L iodine and a linear relationship between 0.04-20 p.g/L. The method was applied to determining the iodine content in marine duck eggs, kelps, laver and Ganoderma lucidum spirulina, showing a relative standard deviation(RSD) of 2.15% and the recoveries in the range of 98.1%-102.5%. 展开更多
关键词 Methyl isobutyl ketone Gas injection atomic fluorescence spectrometer(afs Indirect determination IODINE
原文传递
氢化物发生—原子荧光光谱法(HG-AFS)测定食品中不同价态的无机砷 被引量:20
12
作者 顾微 杨惠芬 《卫生研究》 CAS CSCD 北大核心 1999年第6期372-374,共3页
应用氢化物发生——原子荧光分析技术建立了食品中总无机砷、三价砷[As(Ⅲ)]和五价砷[As(Ⅴ)]的测定方法。用6m ol/LHCl提取食品中无机砷,在2m ol/LHCl条件下测定总无机砷,再利用三价砷、五价砷氢化物... 应用氢化物发生——原子荧光分析技术建立了食品中总无机砷、三价砷[As(Ⅲ)]和五价砷[As(Ⅴ)]的测定方法。用6m ol/LHCl提取食品中无机砷,在2m ol/LHCl条件下测定总无机砷,再利用三价砷、五价砷氢化物发生酸度条件的不同对三价砷进行选择测定。本方法标准曲线线性范围:总无机砷为0~400μg/L,As(Ⅲ)为0~300μg/L;检出限:总无机砷1.6μg/L,As(Ⅲ)1.1μg/L;相对标准偏差:总无机砷为1.93% ,As(Ⅲ)为2.49% ;样品回收率:总无机砷为85% ~105% ,As(Ⅲ)为80% ~115% ;一般食品样品的测定无干扰。 展开更多
关键词 氢化物发生 原子荧光光谱法 食品 无机砷
下载PDF
HPLC-HG-AFS联用技术检测蜂花粉中砷形态 被引量:13
13
作者 王素芬 陈芳 +1 位作者 王鹏 吴黎明 《食品科学》 EI CAS CSCD 北大核心 2013年第12期189-193,共5页
建立高效液相色谱-氢化物发生-原子荧光光谱(HPLC-HG-AFS)联用技术分析蜂花粉中亚砷酸(AsⅢ)、砷酸(AsⅤ)、一甲基砷酸(MMA)和二甲基砷酸(DMA)的方法。以0.20mol/L硫酸溶液为提取溶剂,经超声、离心提取,用0.22μm滤膜过滤后,经高效液相... 建立高效液相色谱-氢化物发生-原子荧光光谱(HPLC-HG-AFS)联用技术分析蜂花粉中亚砷酸(AsⅢ)、砷酸(AsⅤ)、一甲基砷酸(MMA)和二甲基砷酸(DMA)的方法。以0.20mol/L硫酸溶液为提取溶剂,经超声、离心提取,用0.22μm滤膜过滤后,经高效液相色谱-氢化物发生-原子荧光仪分离测定。结果表明:AsⅢ、DMA、MMA和AsⅤ的检测限分别是1.0、2.1、1.2、3.1μg/kg,加标回收率均在79%~100%之间,精密度实验结果(n=4)显示,4种砷形态的相对标准偏差分别为4.5%、2.3%、11.0%、7.7%。该方法快速准确、灵敏度高,是一种较好的定性和定量分析蜂花粉中不同形态砷的方法。 展开更多
关键词 蜂花粉 砷形态 高效液相色谱-氢化物发生-原子荧光仪
下载PDF
氢化物发生-原子荧光光谱法(HG-AFS)测定特硬铅合金中硒和碲 被引量:19
14
作者 陈殿耿 袁玉霞 王皓莹 《中国无机分析化学》 CAS 2012年第2期38-40,64,共4页
建立了氢化物发生-原子荧光光谱法(HG-AFS)测定特硬铅合金中硒和碲的分析方法。试样经硝酸和酒石酸溶解,硫酸沉淀分离基体铅元素。移取部分试液,在40%盐酸介质中直接用氢化物发生-原子荧光光谱法(HG-AFS)测定样品中的硒;另移取部分试液... 建立了氢化物发生-原子荧光光谱法(HG-AFS)测定特硬铅合金中硒和碲的分析方法。试样经硝酸和酒石酸溶解,硫酸沉淀分离基体铅元素。移取部分试液,在40%盐酸介质中直接用氢化物发生-原子荧光光谱法(HG-AFS)测定样品中的硒;另移取部分试液,加入氢溴酸挥发除去砷、锑、锡、硒等元素,在40%盐酸介质中用氢化物发生-原子荧光光谱法(HG-AFS)测定样品中的碲。考察了测定的最佳条件、铅及共存元素对测定的影响。测定硒和碲的相对标准偏差分别为7.5%~9.3%和3.6%~13.0%,加标回收率分别为88%~92%和98%~102%。准确度和精密度均能满足分析需要,具有较强的实用性。 展开更多
关键词 氢化物发生-原子荧光光谱法 铅合金 测定 盐酸介质 加标回收率 沉淀分离
下载PDF
利用LC-AFS与ICP-OES测定污泥中砷形态及总砷含量 被引量:5
15
作者 江晖 廖天宇 +2 位作者 李广鹏 袁玲玲 耿文华 《分析测试学报》 CAS CSCD 北大核心 2018年第9期1034-1039,共6页
应用液相色谱和原子荧光联用(LC-AFS)技术以及在线紫外消解技术分析了污泥中三价砷(As(Ⅲ))、一甲基砷(MMA)、二甲基砷(DMA)、五价砷(As(Ⅴ))和砷甜菜碱(AsB) 5种砷形态含量,并利用电感耦合等离子体发射光谱(ICP-OES)测定了总砷(T-As)... 应用液相色谱和原子荧光联用(LC-AFS)技术以及在线紫外消解技术分析了污泥中三价砷(As(Ⅲ))、一甲基砷(MMA)、二甲基砷(DMA)、五价砷(As(Ⅴ))和砷甜菜碱(AsB) 5种砷形态含量,并利用电感耦合等离子体发射光谱(ICP-OES)测定了总砷(T-As)含量。通过对液相色谱分离、柱后衍生条件的优化,确定流动相为15 mmol/L (NH_4)_2HPO_4,pH 6. 0,载流5%(体积分数) HCl,还原剂为含5 g/L NaOH的10 g/L KBH_4溶液,5种砷形态可在10 min内得到分离、测定。结果表明,总砷含量与各形态砷总和接近,相对标准偏差(RSD)在5%之内; As(Ⅲ)、As(Ⅴ)、MMA、DMA、AsB的检出限(以As计)分别为0. 3、2. 1、1. 4、1. 1、0. 7μg/L,总砷的检出限为0. 8μg/L,且在线性范围内各砷形态和总砷标准曲线的相关系数均大于0. 999。该方法前处理便捷,结果准确、重复性好,可为环境污泥中砷形态分析提供技术基础。 展开更多
关键词 环境危害 污泥 形态测定 液相色谱-原子荧光联用(LC-afs) 电感耦合等离子体发射光谱(ICP-OES)
下载PDF
微波消解-AFS法测定婴幼儿配方奶粉中硒的测量不确定度评定 被引量:4
16
作者 崔颖 葛含光 +1 位作者 温华蔚 倪松 《食品研究与开发》 CAS 北大核心 2016年第11期139-142,共4页
建立微波消解-AFS法测定婴幼儿配方奶粉中硒含量的测量不确定度的测量模型,根据模型分析并计算不确定度各个分量、结果的不确定度以及扩展不确定度。结果表明,引起测量不确定度的最主要来源是测定C值时用最小二乘法拟合标准工作曲线所... 建立微波消解-AFS法测定婴幼儿配方奶粉中硒含量的测量不确定度的测量模型,根据模型分析并计算不确定度各个分量、结果的不确定度以及扩展不确定度。结果表明,引起测量不确定度的最主要来源是测定C值时用最小二乘法拟合标准工作曲线所引入的不确定度。计算得到在婴幼儿奶粉中硒含量为0.310 mg/kg时,扩展不确定度为0.046 mg/kg,包含因子k为2。该方法适用于婴幼儿配方奶粉中硒含量的测量不确定度评定。 展开更多
关键词 测量不确定度 原子荧光光谱法 婴幼儿配方奶粉 微波消解
下载PDF
MAE-LC-AFS测定鸡蛋中阿散酸、洛克沙砷、硝苯砷酸 被引量:3
17
作者 姜涛 崔颖 倪松 《食品研究与开发》 CAS 北大核心 2017年第16期157-161,共5页
建立微波辅助萃取-液相色谱-原子荧光光谱法(Microwave Assisted Extraction-Liquid Chromatography-atomic Fluorescence Spectrometry,MAE-LC-AFS)测定鸡蛋中阿散酸(Arsanilic,ASA)、洛克沙砷(Roxarsone,ROX)、硝苯砷酸(Nitarsone,NIT... 建立微波辅助萃取-液相色谱-原子荧光光谱法(Microwave Assisted Extraction-Liquid Chromatography-atomic Fluorescence Spectrometry,MAE-LC-AFS)测定鸡蛋中阿散酸(Arsanilic,ASA)、洛克沙砷(Roxarsone,ROX)、硝苯砷酸(Nitarsone,NIT)的分析方法。研究并优化液相色谱和原子荧光的工作条件。在0~2.0 mg/L范围内阿散酸、硝苯砷酸和洛克沙砷的线性关系良好,线性相关系数大于0.999,阿散酸、硝苯砷酸、洛克沙砷检出限(S/N=10)分别为0.1、0.2、0.2 mg/kg。阿散酸在0.1、0.2、0.5 mg/kg 3个加标水平下的平均回收率为80.5%~91.0%,相对标准偏差为3.14%~3.77%;硝苯砷酸和洛克沙砷在0.2、0.5、2 mg/kg,3个加标水平下平均回收率为81.0%~91.1%和82.5%~104.9%,相对标准偏差为2.72%~4.02%和1.81%~7.52%。 展开更多
关键词 微波辅助萃取 液相色谱-原子荧光 鸡蛋 阿散酸 硝苯砷酸 洛克沙砷
下载PDF
液相色谱-原子荧光光谱联用(HPLC-AFS)测定市售鱼干中的甲基汞含量 被引量:2
18
作者 林凯 张慧敏 +3 位作者 姜杰 陈裕华 李瑞园 丘红梅 《应用预防医学》 2017年第4期280-283,共4页
目的了解市售鱼干的甲基汞污染情况。方法有代表性地采集深圳市市售鱼干,采用液相色谱与原子荧光光谱联用方法测定鱼干中的甲基汞含量。样品经盐酸超声提取后离心过滤,以5%乙腈-4.62 g/L乙酸铵-1.2 g/L-半胱氨酸溶液作流动相,经反相C18... 目的了解市售鱼干的甲基汞污染情况。方法有代表性地采集深圳市市售鱼干,采用液相色谱与原子荧光光谱联用方法测定鱼干中的甲基汞含量。样品经盐酸超声提取后离心过滤,以5%乙腈-4.62 g/L乙酸铵-1.2 g/L-半胱氨酸溶液作流动相,经反相C18色谱柱分离后由原子荧光光谱仪测定甲基汞含量。结果部分样品检出甲基汞,含量范围为<0.03 mg/kg^0.21 mg/kg,对标准参考物质Fapas T0797罐头鱼和GBW10029金枪鱼的测定结果与参考值相符,说明测定结果真实可靠。结论该法具有操作简便、特异性强、准确可靠的优点,适用于市售鱼干中甲基汞含量的分析。 展开更多
关键词 液相-原子荧光光谱法 甲基汞 鱼干
下载PDF
HG-AFS法测定浆层纸中的铅 被引量:3
19
作者 沈勤 《电池》 CAS CSCD 北大核心 2007年第1期81-82,共2页
利用氢化物发生-原子荧光光谱法(HG-AFS)测定浆层纸中的铅含量。研究了实验条件对荧光强度的影响和共存元素的干扰。方法的检测限为0.031μg/ml,精密度为3.87%,回收率为96.6%-101.4%。此方法的操作简单,灵敏度高。
关键词 浆层纸 氢化物发生-原子荧光光谱法(HG-afs)
下载PDF
AFS法和ICP-MS法测定饲料中砷和汞的比较 被引量:3
20
作者 杜英秋 《粮食与饲料工业》 CAS 2015年第5期62-64,共3页
在优化的实验条件下,应用原子荧光光谱法(AFS)和电感耦合等离子质谱法(ICP-MS)测定饲料中砷和汞,并对两种方法进行比较。AFS法测定饲料中砷和汞的检出限分别为0.062、0.001 3ng/ml,ICP-MS法测定饲料中砷和汞的检出限分别为0.017、0.001 ... 在优化的实验条件下,应用原子荧光光谱法(AFS)和电感耦合等离子质谱法(ICP-MS)测定饲料中砷和汞,并对两种方法进行比较。AFS法测定饲料中砷和汞的检出限分别为0.062、0.001 3ng/ml,ICP-MS法测定饲料中砷和汞的检出限分别为0.017、0.001 5ng/ml。对12份饲料样品中砷和汞的测定结果进行F检验,结果表明:两种方法不存在显著性差异,标准物质测定结果表明两种方法均具有高准确性和精密度。 展开更多
关键词 原子荧光光谱法 电感耦合等离子质谱法 饲料
下载PDF
上一页 1 2 17 下一页 到第
使用帮助 返回顶部