Suppression of laser power error in a miniaturized atomic co-magnetometer based on split ratio optimization
1
作者 张伟佳 范文峰 +1 位作者 范时秒 全伟 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期180-186,共7页
A miniaturized atomic spin-exchange relaxation-free(SERF)co-magnetometer measures angular velocity using a balanced polarimetry technique which is easily affected by the laser power.A laser power closed-loop control s... A miniaturized atomic spin-exchange relaxation-free(SERF)co-magnetometer measures angular velocity using a balanced polarimetry technique which is easily affected by the laser power.A laser power closed-loop control system is usually used to suppress the fluctuation of the laser power.Although this method can greatly eliminate the fluctuation of the in-loop laser power(the feedback laser),it cannot fully eliminate the fluctuation of the out-of-loop laser power(the signal measurement laser).This leads to SERF gyroscope laser power error,which reduces the inertial measurement accuracy.In this paper,the influence mechanism of the split ratio(the ratio of the in-loop laser power to the out-of-loop laser power)on the out-of-loop laser power control accuracy is analyzed by establishing a laser power transmission model inside and outside the loop.Moreover,a method is developed to improve the out-of-loop laser power stability by optimizing the split ratio.Comparative experiments showed that the relative Allan standard deviation of the out-of-loop laser power decreased from 5.48×10^(-6)to 2.62×10^(-6)at 100 s,and decreased by an order of magnitude from 1.76×10^(-5)to 3.30×10^(-6)at1000 s.Correspondingly,the rate ramp coefficient in the Allan standard deviation curve of the SERF gyroscope test data decreased from 1.312[(°/h)/h]to 0.246[(°/h)/h].And the bias stability increased from 0.032°/h to 0.019°/h.Therefore,the proposed method can improve the long-term stability of the probe laser power and effectively suppress the laser power error of the SERF gyroscope. 展开更多
关键词 atomic gyroscope spin-exchange relaxation-free laser power stability error suppression
下载PDF
Continuous Dynamic Rotation Measurements Using a Compact Cold Atom Gyroscope 被引量:12
2
作者 姚战伟 鲁思滨 +4 位作者 李润兵 王锴 曹雷 王谨 詹明生 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第8期41-44,共4页
We present an experimental demonstration of the rotation measurement using a compact cold atom gyroscope. Atom interference fringes are observed in the stationary frame and the rotating frame, respectively. The phase ... We present an experimental demonstration of the rotation measurement using a compact cold atom gyroscope. Atom interference fringes are observed in the stationary frame and the rotating frame, respectively. The phase shift and contrast of the interference fringe are experimentally investigated. The results show that the contrast of the interference fringe is well held when the platform is rotated, and the phase shift of the interference fringe is linearly proportional to the rotation rate of the platform. The long-term stability, which is evaluated by the overlapped Allan deviation, is 8.5 × 10^-6 rad/s over the integrating time of 1000s. 展开更多
关键词 of on as is in Continuous Dynamic Rotation Measurements Using a Compact Cold Atom gyroscope
下载PDF
上一页 1 下一页 到第