Determination of Ultratrace Amounts of Copper(Ⅱ) in Water Samples by Electrothermal Atomic Absorption Spectrometry After Cloud Point Extraction 被引量:10
1
作者 CHEN Jian-guo CHEN neng-wu +2 位作者 CHEN Shao-hong LIN Li ZHONG Ying-ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2007年第2期143-147,共5页
A novel approach was developed for the determination of ultratrace amounts of copper in water samples by using electrothermal atomic absorption spectrometry (ETAAS) after cloud point extraction ( CPE ). 1-( 2-Pyr... A novel approach was developed for the determination of ultratrace amounts of copper in water samples by using electrothermal atomic absorption spectrometry (ETAAS) after cloud point extraction ( CPE ). 1-( 2-Pyridylazo ) -2- naphthol was used as the chelating reagent and Triton X-114 as the mieellar-forming surfactant. CPE was conducted in a pH 8. 0 medium at 40 ℃ for 10 rain. After the separation of the phases by contrifugafion, the surfactant-rieh phase was diluted with 1 mL of a methanol solution of 0. 1 mol/L HNO3. Then 20μL of the diluted surfactant-rieh phase was injected into the graphite furnace for atomization in the absence of any matrix modifier. Various experimental conditions that affect the extraction and atomization processes were optimized. A detection limit of 5 ng/L was obtained after preconeentration. The linear dynamic range of the copper mass concentration was found to be 0-2.0 ng/mL, and the relative standard deviation was found to be less than 3. 1% for a sample containing 1.0 ng/mL Cu ( Ⅱ ). This developed method was successfully applied to the determination of uhratraee amounts of Cu in drinking water, tap water, and seawater samples. 展开更多
关键词 Cloud point extraction Preconeentration Electrothermal atomic absorption spectrometry Copper( Ⅱ) Water analysis
下载PDF
Cloud point extraction and flame atomic absorption spectrometry analysis of palladium, platinum, and gold ions from industrial polluted soil 被引量:5
2
作者 LIAN Yuanpei ZHEN Wei +3 位作者 TAI Zhigang YANG Yaling SONG Jun LI Zonghao 《Rare Metals》 SCIE EI CAS CSCD 2012年第5期512-516,共5页
关键词 cloud point extraction ammonium pyrolysine dithiocarbamate Tergitol TMN-6 Pd Pt AU atomic absorption spectrometry
下载PDF
Analysis of trace mercury in water by solid phase extraction using dithizone modified nanometer titanium dioxide and cold vapor atomic absorption spectrometry 被引量:5
3
作者 MA Xiaoguo HUANG Bei CHENG Meiqing 《Rare Metals》 SCIE EI CAS CSCD 2007年第6期541-546,共6页
A new method for analysis of trace mercury in water samples was developed, based on the combination of preconcentration/separation using dithizone-modified nanometer titanium dioxide (TiO2) as a solid phase extracta... A new method for analysis of trace mercury in water samples was developed, based on the combination of preconcentration/separation using dithizone-modified nanometer titanium dioxide (TiO2) as a solid phase extractant and determination by cold vapor atomic adsorption spectrometry (CVAAS). Dithizone was dissolved with alcohol and loaded on the surface of nano-sized TiO2 powders by stirring. The static adsorption behavior of Hg^2+on the dithizone-modified nanoparficles was investigated in detail. It was found that excellent adsorption ratio for Hg^2+ could be obtained in the pH range of 7-8 with an oscillation time of 15 rain, and a 5 mL of 3.5 mol·L^-1 HCI solution could quantitatively elute Hg^2+ from nanometer TiO2 powder. Common coexisting ions caused no obvious influence on the determination of mercury. The mechanisms for the adsorption and desorption were discussed. The detection limit (30) for Hg^2+ was calculated to be 5 ng·L^-1. The proposed method was applied to the determination of Hg^2+ in a mineral water sample and a Zhujiang River water sample. By the standard addition method, the average recoveries were found to be 94.4%-108.3% with RSD (n = 5) of 2.9%-3.5%. 展开更多
关键词 analytical chemistry MERCURY solid-phase extraction TiO2 nanoparticle cold vapor atomic adsorption spectrometry (CVAAS)
下载PDF
Determination of total arsenic by photo-decomposition of organoarsenic compounds and hydride generation electrothermal atomic absorption spectrometry 被引量:4
4
作者 Han Hengbin, Liu Yanbing, Zhang Shuzhen Ni ZhemingResearch Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing 100085, China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1993年第1期99-107,共9页
A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a p... A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a palladium coated graphite tube with subsequent atomization and detection by AAS. The organoarsenicals include monomethylarsenic, dimethylarsenic, arsenobetaine, arsenocholine, o -aminobenzenarsenate and p -aminobenzenarsenate. The method is simple and sensitive. Detection limit was obtained from different arsenic compounds over the range from 0. 058 to 0.063 ng/ml as As (based on three times of the standard deviation of 10 blank measurements) and the relative standard deviations for ten replicate measurements were from 2.0 to 3.8%. The calibration curves of arsenic compounds including inorganic and organic arsenicals were linear over the range from 0.1 to 3.0 ng/ml as As. The recommended method has been applied to the determination of total arsenic in tap and lake water samples at ng/ml levels. 展开更多
关键词 electrothermal atomic absorption spectrometry photo -decomposition organoarsenic compounds arsenic hydride generation tap/lake water
下载PDF
Determination of Trace Amounts of Nickel (Ⅱ) by Graphite Furnace Atomic Absorption Spectrometry Coupled with Cloud Point Extraction 被引量:3
5
作者 SHAH Syed Mazhar WANG Hao-nan SU Xing-guang 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第3期366-370,共5页
A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-... A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-hydroxyquinoline and Triton X-100 were used as the ligand and surfactant respectively. Nickel(Ⅱ) can form a hy-drophobic complex with 8-hydroxyquinoline, the complex can be extracted into the small volume surfactant rich phase at the cloud point temperature(CPT) for GFAAS determination. The factors affecting the cloud point extraction, such as pH, ligand concentration, surfactant concentration, and the incubation time were optimized. Under the optimal conditions, a detection limit of 12 ng/L and a relative standard deviation(RSD) of 2.9% were obtained for Ni(Ⅱ) determination. The enrichment factor was found to be 25. The proposed method was successfully applied to the determination of nickel(Ⅱ) in certified reference material and different types of water samples and the recovery was in a range of 95%―103%. 展开更多
关键词 Cloud point extraction Phase separation Graphite furnace atomic absorption spectrometry Nickel(Ⅱ)
下载PDF
Application of multiwalled carbon nanotubes treated by potassium permanganate for determination of trace cadmium prior to flame atomic absorption spectrometry 被引量:3
6
作者 XIAO Jun-ping ZHOU Qing-xiang BAI Hua-hua 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第10期1266-1271,共6页
In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption ... In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption spectrometry. The MWCNTs were oxidized by potassium permanganate under appropriate conditions before use as preconcentration packing. Parameters influencing the recoveries of target analytes were optimized. Under optimal conditions, the target analyte exhibited a good linearity (R^2=0.9992) over the concentration range 0.5-50 ng/ml. The detection limit and precision of the proposed method were 0.15 ng/ml and 2.06%, respectively. The proposed method was applied to the determination of cadmium in real-world environmental samples and the recoveries were in the range of 91.3%-108.0%. All these experimental results indicated that this new procedure could be applied to the determination of trace cadmium in environmental waters. 展开更多
关键词 multiwalled carbon nanombes (MWCNTs) solid-phase extraction flame atomic absorption spectrometry
下载PDF
Flow Injection Semi-online Preconcentration Graphite Furnace Atomic Absorption Spectrometry for Determination of Cadmium,Copper and Manganese 被引量:3
7
作者 ZHANG Yi-hua, WANG Mei-jia, SU Xing-guang, ZHENG Tao, ZHANG Han-qi and JIN Qin-han Department of Chemistry, Jilin University, Changchun 130023, P. R. ChinaCHEN YingJilin Environmental Monitoring Centre, Changchun 130011, P. R. China 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2002年第1期1-7,共7页
A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometry that formed an integrated system for the determination of trace amounts of elements... A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometry that formed an integrated system for the determination of trace amounts of elements. The analytical performances of the prospsed method for determining Cd, Cu and Mn were studied. The analytes were preconcentrated with a thiol resin(Type 190, produced by Nankai University, China) whose active group is -SH. The elements to be determined were preconcentrated onto the column for 60 s and then rinsed with deionized water and eluted with 30 μL of 1 mol/L HCl. The graphite furnace atomic absorption spectrometry(GFAAS) determination of the concentrated analyte was carried out in parallel with the next preconcentration cycle. Enrichment factors 41, 22 and 20 and detection limits(3 σ , n =10) 0.36, 3.8 and 7.0 ng/L for Cd, Cu and Mn, respectively, along with a sampling frequency of 20 h -1 , were obtained with a 60 s loading time at a sample flow rate of 3.5 mL/min. The analytical results for a number of water samples show that the flow-injection semi-online column preconcentration can not only eliminate the effect of some concomitant elements, such as Li, Na, K, Ca and Mg, on the determination of the analyte, but also enhance the sensitivity. 展开更多
关键词 FLOW-INJECTION Semi-online preconcentration atomic absorption spectrometry Cadmium Copper Manganese
下载PDF
On-line Preconcentration of Trace Nickel from Electrolytic Manganese Using Minicolumn Packed Activated Carbon for Electrothermal Atomic Absorption Spectrometry 被引量:2
8
作者 姚俊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2004年第4期17-20,共4页
The online flow injection preconcentration and electrothermal atomic absorption spectrometry method were used for the determination of trace nickel in electrolytic manganese samples by sorption on a conical minicolumn... The online flow injection preconcentration and electrothermal atomic absorption spectrometry method were used for the determination of trace nickel in electrolytic manganese samples by sorption on a conical minicolumn packed with activated carbon at pH 9.0. The nickel was eluted from the minicolumn with 10%(v/v) nitric acid. An enrichment factor of 190-fold for a sample volume of 10mL was obtained. The detection limit (DL) of nickel with the use of the preconcentration method was 13ng·g -1in the original solid sample. The precision for 10 replicate determinations at 150ng·g -1 nickel concentration was 5.2% relative standard deviation (RSD). The calibration graph was linear with a correlation coefficient of r=0.9996 up to concentration of 660ng·g -1 nickel. 展开更多
关键词 online preconcentration NICKEL electrothermal atomic absorption spectrometry activated carbon electrolytic manganese
下载PDF
Preconcentration of copper with multi-walled carbon nanotubes pretreated by potassium permanganate cartridge for solid phase extraction prior to flame atomic absorption spectrometry 被引量:2
9
作者 Jun Ping Xiao Qing Xiang Zhou Hua Hua Bai 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期714-717,共4页
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s... A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment. 展开更多
关键词 Multi-walled carbon nanotubes Solid phase extraction (SPE) Flame atomic absorption spectrometry
下载PDF
Determination of trace elements in maifanite by outer cover electrode atomic emission spectrometry 被引量:1
10
作者 LIJianqiang LUYiqiang JIANGWei 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期161-165,共5页
Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer ... Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer cover electrode atomic emission spectrometry, and thedetermination conditions were studied systematically. The results show that the concentrations ofelements, which are beneficial to human health, are higher, and the elements harmful to peoplehealth such as As, Cd, Hg, Cr, and Pb are tiny in maifanite. The precision and the accuracy werealso discussed. 展开更多
关键词 atomic emission spectrometry outer cover electrode DETERMINATION TRACEELEMENTS maifanite
下载PDF
Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier 被引量:1
11
作者 Zhi Hua WANG Min CAI Shu Jun WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第6期809-812,共4页
The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously e... The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously eliminated silicate interference. Under the optimum operating conditions, the determination results of iron in layered crystal sodium disilicate and sodium silicate samples by FAAS were satisfactory. The linear range of calibration curve is 0-10.5 μg.mL^-1, the relative standard deviation of method is 1.2%-2.2%, the recovery of added iron is 96.0%- 101%, the sensitivity is 0.19 μg.mL^-l and the detection limit is 77 ng.mL^-1. The effect of the determination of iron of the standard curve method, standard addition calibration and colorimetry method was the same, but the first has the merits of rapid sample preparation, reduced contamination risks and fast analysis. 展开更多
关键词 Layered crystal sodium disilicate sodium silicate flame atomic absorption spectrometry determination of iron boric acid.
下载PDF
Preconcentration of Vanadium(Ⅴ) on Crosslinked Chitosan and Determination by Graphite Furnace Atomic Absorption Spectrometry 被引量:1
12
作者 Wu Wei Qian Sha-hua +2 位作者 Xiao Mei Huang Gan-quan Chen Hao 《Wuhan University Journal of Natural Sciences》 CAS 2002年第2期222-226,共5页
A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by C... A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by CCTS was 97% at pH 4.0, and vanadium(Ⅴ) was eluted from crosslinked chitosan with 2 mL 2.0 mol·L -1 chlorhydric acid and determined by GFAAS. The detection limit (3σ,n=7) for vanadium(Ⅴ) was 4.8×1 0 -12g and the relative standard deviation (R.S.D) at concentration level of 2.6 μg·L -1 is less than 3.6%. The method shows a good selectivity and high sensitivity, and it was applied to determination of vanadium(Ⅴ) in oyster and water samples. The analytic recoveries are (97±5)%. 展开更多
关键词 crosslinked chitosan (CCTS) vanadium(Ⅴ) PRECONCENTRATION DESORPTION graphite furnace atomic absorption spectrometry (GFAAS) OYSTER sea water
下载PDF
Determination of Trace Selenium in Electrolytic Manganese by Graphite Furnace Atomic Absorption Spectrometry 被引量:1
13
作者 姚俊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2003年第2期32-34,共3页
The effects of four types of graphite tube and five matrix modifiers on the determination of selenium by graphite furnace atomic absorption spectrometry were compared.The results show that platform thermolysis coat gr... The effects of four types of graphite tube and five matrix modifiers on the determination of selenium by graphite furnace atomic absorption spectrometry were compared.The results show that platform thermolysis coat graphite tube and magnesium nitrate and cobaltco as matrix modifer can get a high sensitivity and a good recovery.The optimized working conditions and interference in the determination were invesigated.This result is consistent with that of XRF.The recovery is from 100.8 % to102.2 %,the relative standard deviation is from 3.47% to 5.56 % (n=9),and the detection limit of selenium is 378 pg (C=44.5μg/g to 97.3μg/g.).The proposed method can be applied to the rapid determination of selenium in electrolytic manganese. 展开更多
关键词 electrolytic manganese SELENIUM matrix modifier atomic absorption spectrometry
下载PDF
Determination of Trace Iron in High Purity Sodium Fluoride by Graphite Furnace Atomic Absorption Spectrometry 被引量:1
14
作者 QIAN Sha-hua HUANG Gan-quan +2 位作者 XUE Ai-fang CHEN Li-hua WANG Mei-lin (College of Chemistry and Environmental Science, Wuhan University, Wuhan, 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期106-108,共3页
A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that th... A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that the ashing temperature can be increased to 1 400°C and matrix interferences eliminated, the sensitivity of iron increased in 1. 27 fold by the addition of nickel nitrate. The method is applied to the determination of iron in sodium fluoride and satisfactory results are obtained. 展开更多
关键词 Key words Graphite furnace atomic absorption spectrometry iron determination sodium fluoride matrix modifier
下载PDF
Uncertainty in Detecting Copper and Zinc Contents in Maize Flour by Flame Atomic Absorption Spectrometry with Wet Digestion Method 被引量:1
15
作者 Jianghua SHAN 《Agricultural Biotechnology》 CAS 2016年第1期1-4,7,共5页
[ Objective] This study aimed to evaluate the uncertainty in detecting copper and zinc contents in maize flour by flame atomic absorption spectrometry. [ Method] Combined with the actual inspection experience, the unc... [ Objective] This study aimed to evaluate the uncertainty in detecting copper and zinc contents in maize flour by flame atomic absorption spectrometry. [ Method] Combined with the actual inspection experience, the uncertainty in detecting copper and zinc contents in maize flour by tame atomic absorption spec- trometry was evaluated to establish the mathematical model. The uncertainty sources in the experimental process were investigated to analyze several components af- fecting the uncertainty in sample detection, including sample weighing, standard material transfer, solution dilution and volume setting, curve fitting, and repeat- ability of measurement instruments. [ Result] Standard curve fitting and repeatability test were two major factors that significantly affected the combined standard uncertainty. However, in the actual detection process, standard curve calibration and repeated detection procedures should be controlled strictly. Finally, the ex- panded uncertainty of copper and zinc contents in maize flour was ( 1.38 ± 0.08) mg/kg and ( 10.20 ± 1.20) mg/kg, respectively. [ Conclusion] This study provided reference for improving the accuracy and reliability of the detection method. 展开更多
关键词 atomic absorption spectrometry UNCERTAINTY Maize flour COPPER ZINC
下载PDF
Determination of Manganese in Tri Calcium Phosphate (TCP) by Atomic Absorption Spectrometry 被引量:1
16
作者 Y. Yildiz R. Karadag +1 位作者 M. Cordera B. Gensinger 《American Journal of Analytical Chemistry》 2020年第8期301-308,共8页
Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standard... Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standards. A number of analytical methods are presently used for the analysis of metals in the biochemical. The instrumental techniques available are Inductively Coupled Plasma (ICP/MS), X-Ray Fluorescence, UV-VIS Spectrophotometry, and Atomic Absorption Spectrometry. Flame AA has gained widespread acceptance as an analytical technique and is used for many applications. In this study, we have determined the amount of manganese metal present in Tricalcium Phosphate (TCP) using Flame Atomic Absorption Spectrophotometer. The method has high precision and accuracy. The percent recovery was found to be 99.8% for spiked sample. The results meet the requirement. 展开更多
关键词 Manganese Determination Tri Calcium Phosphate Flame atomic Absorption spectrometry
下载PDF
EVALUATON OF MICROWAVE PLASMA TORCH FOR ATOMIC FLUORESCENCE SPECTROMETRY WITH AN ULTRASONIC NEBULIZATION SAMPLE INTRODUCTION SYSTEM
17
作者 Yi Mu LI Yi Xiang DUAN +1 位作者 Jun LIU Qin Han JIN Department of Chemistry, Jilin University, Changchun, 130O23 《Chinese Chemical Letters》 SCIE CAS CSCD 1993年第7期615-618,共4页
In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in det... In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail. 展开更多
关键词 TORCH EVALUATON OF MICROWAVE PLASMA TORCH FOR atomic FLUORESCENCE spectrometry WITH AN ULTRASONIC NEBULIZATION SAMPLE INTRODUCTION SYSTEM Cd USN LONG HCL MPT
下载PDF
DeterminationofNi,Ca,Mg,CuandPbinWolframbyInductivelyCoupledPlasmaAtomicEmisionSpectrometry
18
作者 王春梅 张淑珍 《Rare Metals》 SCIE EI CAS CSCD 1997年第1期28-31,共4页
The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensa... The method for the determination of Ni, Ca, Mg, Cu and Pb in wolfram wire by ICP AES was studied. Results showed that perhydrol affects the intensities of elements (Ni, Ca, Mg, Cu, Pb) and this effect can be compensated by internal reference element. It is also showed that the stability of plasma caused by perhydrol matrix was effectively improved. The replicate experiment and recovery experiment revealed perfect precision and accuracy. Results got by two methods were just the same. 展开更多
关键词 WOLFRAM Trace elements atomic emission spectrometry
下载PDF
Determination of Carbon by Means of Microwave Plasma Torch Atomic Emission Spectrometry
19
作者 ZHANG Han-qi YUAN Xiang-lin +1 位作者 YE Dong-mei ZHAO Xiao-jun and JIN Qin-han (Department Of Chemistry, Jilin University, Changchun, 130023)ZHU Zhi-ping(Department of Chemistry, Northeast Normal University, Changchun, 130024) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1996年第1期32-36,共5页
The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon wa... The determination of carbon by means of microwave plasma torch atomic emission spectrometry(MPT-AES) was studied. Aqueous samples were introduced with a pneumatic nebulization system. The detection limit for carbon was 0. 047μg/mL.The method was applied to the analysis for tap water and results were satisfactory. 展开更多
关键词 Microwave plasma torch atomic emission spectrometry CARBON
下载PDF
A Study on Determination of Some Trace Nonmetals by Microwave Induced Plasma Atomic Emission Spectrometry
20
作者 Zhang Jinsheng, Ye Dongmei, Zhang Hanqi and Jin Qinhan (Department of Chemistry, Jilin University, Changchun) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1992年第1期29-30,共2页
In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the res... In general, atomic emission spectrometry (AES) is an excellent technique for determination of metal elements. However, its capability of determining nonmetals has not been developed well. The major reasons are the resonance lines of most nonmetals lie in the vacuum ultraviolet spectral region and the ionic lines of these elements are difficult to be used because the ionization potentials of the elements are very high. And furthermore only He plasma can efficiently excit those ionic resonance lines. The practical application of HeICP-AES to determining the nonmetals is also difficult because its operating and perchace costs are very high. In contrast to HeICPAES, the costs of He microwave induced plasma (MIP)-AES are relatively low, HeMIP has a high excitation capability which can excite ionic lines of various nonmetals and the nonmetals can be determined by HeMIP-AES with a high sensitivity. 展开更多
关键词 Microwave induced plasma atomic emission spectrometry NONMETALS
下载PDF