期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
The Effect of Atrial Septal Defect Closure on Cardiac Volumetric Changes in Adults, Transcatheter Versus Surgical Closure, a Pilot Cardiac Magnetic Resonance Study
1
作者 Amr Mansour Noha M.Gamal +3 位作者 Alaa M.Nady Amr Ibraheem Dalia M.Salah Khaled M.El-Maghraby 《Congenital Heart Disease》 SCIE 2023年第6期679-691,共13页
Background:Closure of an atrial septal defect(ASD)reduces right-side heart volumes by abolishing shunting with simultaneous improvement of the left ventricle(LV)filling and functions due to ventricular interdependence,... Background:Closure of an atrial septal defect(ASD)reduces right-side heart volumes by abolishing shunting with simultaneous improvement of the left ventricle(LV)filling and functions due to ventricular interdependence,thereby improving symptoms.Furthermore,studies conducted on atrial volume changes after ASD closure are limited.Cardiac magnetic resonance(CMR)is considered as the gold standard method for measuring cardiac volume and mass.Objective:We aimed to study the effect of transcatheter and surgical closure of secundum ASD on cardiac volumes and systolic functions as well as the fate of tricuspid regurgitation(TR),using CMR analysis.Methods:We prospectively enrolled 30 adult patients with isolated secundum ASD who were referred to ASD closure.CMR evaluation of cardiac chambers indexed volumes,systolic function,myocardial mass index,and tricuspid regurgitant fraction were done at before and 6 months after closure.Results:RV volumes decreased in both groups when compared to baseline(p-value 0.001),the device group had more reduction in volumes and more improvement in RV function after closure(p-value 0.001)when compared to the surgical arm.The changes in the RV mass index were insignificant between both groups(p-value 0.31).Functional TR improved to the same extent in both groups.Left ventricular end diastolic volume index(LVEDVI)and LV mass index increased sig-nificantly in both groups when compared to baseline in both groups but with no difference between groups p-value 0.01),left ventricular end systolic volume index(LVESVI)changes were insignificant.LV systolic function improved in patients who underwent device closure only(63.53±3.85 vs.67.13±4.34,p-value 0.01).There was a significant reduction in right atrial(RA)volumes and an insignificant decrease in left atrial(LA)volumes,with no difference between groups.Conclusion:Transcatheter and surgical secundum ASD closure resulted in volumetric changes in some cardiac chambers with better improvement in bi-ventricular systolic function in the transcatheter arm and no difference in the TR reduction between the two groups at 6 months follow-up by CMR. 展开更多
关键词 atrial septal defect closure cardiac volumetric changes functional tricuspid regurgitation cardiac CMR
下载PDF
TRANSCATHETER CLOSURE OF LARGE SECUNDUM ATRIAL SEPTAL DEFECTS WITH AMPLATZER~ SEPTAL OCCLUDER
2
作者 杨震坤 Aubry Pierre +1 位作者 Eric Brochet Jean-Michel Juliard 《Medical Bulletin of Shanghai Jiaotong University》 CAS 2010年第1期40-46,共7页
Objective To evaluate the safety and feasibility of transcatheter closure of large secundum atrial septal defects(ASDs)with Amplatzer~ septal occluder(ASO).Methods A total of 26 patients(age 16 to 67 years,median 43... Objective To evaluate the safety and feasibility of transcatheter closure of large secundum atrial septal defects(ASDs)with Amplatzer~ septal occluder(ASO).Methods A total of 26 patients(age 16 to 67 years,median 43 years;body weight 52 to 102 kg,median 67 kg)with large ASDs underwent an attempted transcatheter closure using ASO.Large ASD was defined as those with a balloon-stretched diameter of ≥30 mm.Another 81 patients with small-to-moderate ASD during same period who underwent closure served as controls.Results In patients with large ASDs,the ASD dimension means were(22.1±3.2)mm(range from 16 to 30 mm)and(23.8±2.6)mm(range from 18 to 31mm)assessed by transesophageal echocardiography(TEE)and transthoracic echocardiography(TTE),respectively.The mean balloon-stretched diameter of the ASD was(31.9±2.1)mm(range from 30 to 37mm).The size of device was(32.0±1.9)mm(range from 30 to 36mm).The transcatheter procedure was successful in all patients(100%).Seventeen deployments were performed using the conventional left atrium approach,and remaining 9 patients required the right upper pulmonary vein approach.Immediately after deployment,TEE revealed that complete closure rate was 73%.Procedure-related complications were recorded in 3 patients(12%),including device embolization in one patient,pericardial effusion in one patient,and large hematoma at puncture site in one patient.During follow-up,the complete closure rate increased to 88% at 24h after procedure and 100% at 6 months.The procedural success rates,immediate TEE results and TTE results at 24h and 6 months after procedure,were not significantly different between patients with large ASDs and those with small-to-moderate ASDs.Conclusion Transcatheter closure of large ASDs using ASO is technical feasible and relatively safe.Proper care selection and specific technique modification such as the right upper pulmonary vein approach is vital for the implantation success. 展开更多
关键词 atrial septal defect transcatheter closure Amplatzer septal occluder
下载PDF
Transcatheter closure of secundum atrial septal defect using an Amplatzer septal occluder 被引量:1
3
作者 孔祥清 曹克将 +4 位作者 杨荣 许迪 盛燕辉 黄峻 马文珠 《Chinese Medical Journal》 SCIE CAS CSCD 2002年第1期126-128,155-156,共3页
Objective To evaluate the safety and efficacy of the Amplatzer septal occluder for transcatheter closure in patients with secundum atrial septal defect (ASD Ⅱ).Methods Patients with clinically confirmed ASD Ⅱ were... Objective To evaluate the safety and efficacy of the Amplatzer septal occluder for transcatheter closure in patients with secundum atrial septal defect (ASD Ⅱ).Methods Patients with clinically confirmed ASD Ⅱ were recommended for transcatheter closure of ASD Ⅱ. Results 30 ASD Ⅱ patients (20 females) underwent transcatheter closure at a median age of 18.4 years (5-55 years). Both the stretched diameters of ASDs and the sizes of the devices were from 18 to 34?mm (25±7?mm). The successful placement rate was 100%. The rest shunt documented by color Doppler, was immediately after implantation in 40% of patients, in 9.9% after 24 hours, and in 3.3% trace at 3 months. No serious complications were observed. There was improvement in symptoms and in cardiac size. Septal motion abnormalities normalized in all patients after 3 months follow-up.Conclusion The Amplatzer septal occluder is a safe and effective device for transcatheter closure of ASD Ⅱ. Long-term follow-up is still required before widespread clinical use can be recommended. 展开更多
关键词 transcatheter closure · secundum atrial septal defect · Amplatzer septal occluder
原文传递
上一页 1 下一页 到第