Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously anal...Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously analyze various parts of a sample,such as different brain areas.In addition,conventional objective lenses struggle to perform consistently across the required range of wavelengths for brain imaging in vivo.Here we present a novel mesoscopic objective lens with an impressive field of view of 8 mm,a numerical aperture of 0.5,and a working wavelength range from 400 to 1000 nm.We achieved a resolution of 0.74μm in fluorescent beads imaging.The versatility of this lens was further demonstrated through high-quality images of mouse brain and kidney sections in a wide-field imaging system,a confocal laser scanning system,and a two-photon imaging system.This mesoscopic objective lens holds immense promise for advancing multi-wavelength imaging of large fields of view at high resolution.展开更多
The most important optical component in an optical fiber endoscope is its objective lens.To achieve a high imaging performance level,the development of an ultra-compact objective lens is thus the key to an ultra-thin ...The most important optical component in an optical fiber endoscope is its objective lens.To achieve a high imaging performance level,the development of an ultra-compact objective lens is thus the key to an ultra-thin optical fiber endoscope.In this work,we use femtosecond laser 3D printing to develop a series of micro objective lenses with different optical designs.The imaging resolution and field-of-view performances of these printed micro objective lenses are investigated via both simulations and experiments.For the first time,multiple micro objective lenses with different fields of view are printed on the end face of a single imaging optical fiber,thus realizing the perfect integration of an optical fiber and objective lenses.This work demonstrates the considerable potential of femtosecond laser 3D printing in the fabrication of micro-optical systems and provides a reliable solution for the development of an ultrathin fiber endoscope.展开更多
We present and discuss deep high resolution images taken with the ESO NTT as well as spectra taken with the ESO VLT in the field of the BL Lac object PKS 0537 441. We could neither detect the host galaxy nor a galaxy ...We present and discuss deep high resolution images taken with the ESO NTT as well as spectra taken with the ESO VLT in the field of the BL Lac object PKS 0537 441. We could neither detect the host galaxy nor a galaxy along the line of sight to the BL Lac as claimed from previous observations. We found 4 nearby companion galaxies which could be a splitted and magnified image of a distant background galaxy. Our VLT spectra, however, rule out this possibility. All 4 companions have similar redshifts as the BL Lac and may (at least in part) trigger the enormous activity in this source. PKS 0537 441 might be located in a galaxy cluster as rich as Abell 1. Alternatively, the BL Lac could also be located in the outskirts of a galaxy cluster or even be projected on a large scale structure as indicated by spectra of 30 galaxies in the field. Either lensing hypothesis (lens or being lensed) is considerably weakened by our observations.展开更多
AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four ...AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.展开更多
This research introduces a challenge in integrating and cleaning the data,which is a crucial task in object matching.While the object is detected and then measured,the vibration at different light intensities may influ...This research introduces a challenge in integrating and cleaning the data,which is a crucial task in object matching.While the object is detected and then measured,the vibration at different light intensities may influence the durability and reliability of mechanical systems or structures and cause problems such as damage,abnormal stopping,and disaster.Recent research failed to improve the accuracy rate and the computation time in tracking an object and in the vibration measurement.To solve all these problems,this proposed research simplifies the scaling factor determination by assigning a known real-world dimension to a predetermined portion of the image.A novel white color sticker of the known dimensions marked with a color dot is pasted on the surface of an object for the best result in the template matching using the Improved Up-Sampled Cross-Correlation(UCC)algorithm.The vibration measurement is calculated using the Finite-Difference Algorithm(FDA),a machine vision systemfitted with a macro lens sensor that is capable of capturing the image at a closer range,which does not affect the quality of displacement measurement from the video frames.Thefield test was conducted on the TAFE(Tractors and Farm Equipment Limited)tractor parts,and the percentage of error was recorded between 30%and 50%at very low vibration values close to zero,whereas it was recorded between 5%and 10%error in most high-accelerations,the essential range for vibration analysis.Finally,the suggested system is more suitable for measuring the vibration of stationary machinery having low frequency ranges.The use of a macro lens enables to capture of image frames at very close-ups.A 30%to 50%error percentage has been reported when the vibration amplitude is very small.Therefore,this study is not suitable for Nano vibration analysis.展开更多
针对曲面光学镜片表面缺陷检测精度不高的问题,提出一种基于改进YOLOv5s的曲面光学镜片缺陷检测方法。首先,设计镜片表面缺陷采集装置,并对采集到的缺陷图片进行数据增强以制作镜片缺陷数据集。其次,为了增强YOLOv5s网络对通道信息的利...针对曲面光学镜片表面缺陷检测精度不高的问题,提出一种基于改进YOLOv5s的曲面光学镜片缺陷检测方法。首先,设计镜片表面缺陷采集装置,并对采集到的缺陷图片进行数据增强以制作镜片缺陷数据集。其次,为了增强YOLOv5s网络对通道信息的利用,在特征提取网络引入SE注意力机制,使网络能够更加准确地提取信息;并在主干网络最后一个C3模块融入Transformer,帮助网络更好地提取全局信息,提高检测效率。最后,考虑到小目标特征信息容易丢失的问题,将主干网络160×160像素的特征层加入颈部的特征融合中,增加网络对浅层信息的利用。改进的YOLOv5s目标检测算法的均值平均精度(mean average precision,mAP)和召回率(recall,R)分别为93.9%和91.6%,比原网络算法分别提高了3.2%和3.4%,表明改进YOLOv5s算法可以有效检测出镜片表面缺陷。展开更多
基金supported by National Key R&D Program of China(grant no.2022YFC2404201)the Chinese Academy of Sciences Project for Young Scientists in Basic Research(grant no.YSBR067).
文摘Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously analyze various parts of a sample,such as different brain areas.In addition,conventional objective lenses struggle to perform consistently across the required range of wavelengths for brain imaging in vivo.Here we present a novel mesoscopic objective lens with an impressive field of view of 8 mm,a numerical aperture of 0.5,and a working wavelength range from 400 to 1000 nm.We achieved a resolution of 0.74μm in fluorescent beads imaging.The versatility of this lens was further demonstrated through high-quality images of mouse brain and kidney sections in a wide-field imaging system,a confocal laser scanning system,and a two-photon imaging system.This mesoscopic objective lens holds immense promise for advancing multi-wavelength imaging of large fields of view at high resolution.
基金This work was supported by Shenzhen Science and Technology Program(RCYX20200714114524139,Shenzhen Key Laboratory of Ultrafast Laser Micro/Nano Manufacturing ZDSYS20220606100405013)Natural Science Foundation of Guangdong Province(2022B1515120061)National Natural Science Foundation of China(62122057,62075136).
文摘The most important optical component in an optical fiber endoscope is its objective lens.To achieve a high imaging performance level,the development of an ultra-compact objective lens is thus the key to an ultra-thin optical fiber endoscope.In this work,we use femtosecond laser 3D printing to develop a series of micro objective lenses with different optical designs.The imaging resolution and field-of-view performances of these printed micro objective lenses are investigated via both simulations and experiments.For the first time,multiple micro objective lenses with different fields of view are printed on the end face of a single imaging optical fiber,thus realizing the perfect integration of an optical fiber and objective lenses.This work demonstrates the considerable potential of femtosecond laser 3D printing in the fabrication of micro-optical systems and provides a reliable solution for the development of an ultrathin fiber endoscope.
文摘We present and discuss deep high resolution images taken with the ESO NTT as well as spectra taken with the ESO VLT in the field of the BL Lac object PKS 0537 441. We could neither detect the host galaxy nor a galaxy along the line of sight to the BL Lac as claimed from previous observations. We found 4 nearby companion galaxies which could be a splitted and magnified image of a distant background galaxy. Our VLT spectra, however, rule out this possibility. All 4 companions have similar redshifts as the BL Lac and may (at least in part) trigger the enormous activity in this source. PKS 0537 441 might be located in a galaxy cluster as rich as Abell 1. Alternatively, the BL Lac could also be located in the outskirts of a galaxy cluster or even be projected on a large scale structure as indicated by spectra of 30 galaxies in the field. Either lensing hypothesis (lens or being lensed) is considerably weakened by our observations.
文摘AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method.
文摘This research introduces a challenge in integrating and cleaning the data,which is a crucial task in object matching.While the object is detected and then measured,the vibration at different light intensities may influence the durability and reliability of mechanical systems or structures and cause problems such as damage,abnormal stopping,and disaster.Recent research failed to improve the accuracy rate and the computation time in tracking an object and in the vibration measurement.To solve all these problems,this proposed research simplifies the scaling factor determination by assigning a known real-world dimension to a predetermined portion of the image.A novel white color sticker of the known dimensions marked with a color dot is pasted on the surface of an object for the best result in the template matching using the Improved Up-Sampled Cross-Correlation(UCC)algorithm.The vibration measurement is calculated using the Finite-Difference Algorithm(FDA),a machine vision systemfitted with a macro lens sensor that is capable of capturing the image at a closer range,which does not affect the quality of displacement measurement from the video frames.Thefield test was conducted on the TAFE(Tractors and Farm Equipment Limited)tractor parts,and the percentage of error was recorded between 30%and 50%at very low vibration values close to zero,whereas it was recorded between 5%and 10%error in most high-accelerations,the essential range for vibration analysis.Finally,the suggested system is more suitable for measuring the vibration of stationary machinery having low frequency ranges.The use of a macro lens enables to capture of image frames at very close-ups.A 30%to 50%error percentage has been reported when the vibration amplitude is very small.Therefore,this study is not suitable for Nano vibration analysis.
文摘针对曲面光学镜片表面缺陷检测精度不高的问题,提出一种基于改进YOLOv5s的曲面光学镜片缺陷检测方法。首先,设计镜片表面缺陷采集装置,并对采集到的缺陷图片进行数据增强以制作镜片缺陷数据集。其次,为了增强YOLOv5s网络对通道信息的利用,在特征提取网络引入SE注意力机制,使网络能够更加准确地提取信息;并在主干网络最后一个C3模块融入Transformer,帮助网络更好地提取全局信息,提高检测效率。最后,考虑到小目标特征信息容易丢失的问题,将主干网络160×160像素的特征层加入颈部的特征融合中,增加网络对浅层信息的利用。改进的YOLOv5s目标检测算法的均值平均精度(mean average precision,mAP)和召回率(recall,R)分别为93.9%和91.6%,比原网络算法分别提高了3.2%和3.4%,表明改进YOLOv5s算法可以有效检测出镜片表面缺陷。
文摘针对传统的传像系统易受电磁干扰的问题,设计并实现了在特殊环境下使用的光纤束传像系统。利用ZEMAX光学仿真软件,设计出了一个工作波段为可见光,全视场80°,焦距为5 mm的监控物镜。该物镜各视场光学调制传递函数(Modulation Transfer Function,MTF)值在空间频率36 lp/mm处大于0.8,点列图最大弥散斑均方根半径(RMSradius)为3.031μm,接近衍射极限,因此具有较高成像质量。采用加工的物镜、选型转接镜及光纤束等核心器件,搭建了传像系统。通过测试光纤束图像传输系统的抗电磁干扰性能,采用高斯低通滤波结合DCT同态滤波算法有效去除图像的像素,获得了高质量的信息传输效果。