In this paper, two automatically calculated thresholds based on a statistical analysis of the histogram were used to apply binary segmentation to the bitmap. When the CCD and the microscope have been properly configur...In this paper, two automatically calculated thresholds based on a statistical analysis of the histogram were used to apply binary segmentation to the bitmap. When the CCD and the microscope have been properly configured and the raw image is preprocessed, the Otsu's method can meet the need of the control program on the whole.展开更多
Objective: To design and test the accuracy and efficiency of our lung segmentation algorithm on thoracic CT image in computer-aided diagnostic (CAD) system, especially on the segmentation between left and right lungs....Objective: To design and test the accuracy and efficiency of our lung segmentation algorithm on thoracic CT image in computer-aided diagnostic (CAD) system, especially on the segmentation between left and right lungs. Methods: We put forward the base frame of our lung segmentation firstly. Then, using optimal thresholding and mathematical morphologic methods, we acquired the rough image of lung segmentation. Finally, we presented a fast self-fit segmentation refinement algorithm, adapting to the unsuccessful left-right lung segmentation of thredsholding. Then our algorithm was used to CT scan images of 30 patients and the results were compared with those made by experts. Results: Experiments on clinical 2-D pulmonary images showed the results of our algorithm were very close to the expert’s manual outlines, and it was very effective for the separation of left and right lungs with a successful segmentation ratio 94.8%. Conclusion: It is a practicable fast lung segmentation algorithm for CAD system on thoracic CT image.展开更多
文摘In this paper, two automatically calculated thresholds based on a statistical analysis of the histogram were used to apply binary segmentation to the bitmap. When the CCD and the microscope have been properly configured and the raw image is preprocessed, the Otsu's method can meet the need of the control program on the whole.
基金the National Key Basic Research and Development Plan of China ("973" Projects, 2003CB716104)the Key Program of the National Natural Science Foundation of China (30730036)+1 种基金the Sci & Tech Planning Program of Guangdong Province (2007B010400058)the Sci & Tech Project Foundation of Guangzhou City (2007Z3-E0031)
文摘Objective: To design and test the accuracy and efficiency of our lung segmentation algorithm on thoracic CT image in computer-aided diagnostic (CAD) system, especially on the segmentation between left and right lungs. Methods: We put forward the base frame of our lung segmentation firstly. Then, using optimal thresholding and mathematical morphologic methods, we acquired the rough image of lung segmentation. Finally, we presented a fast self-fit segmentation refinement algorithm, adapting to the unsuccessful left-right lung segmentation of thredsholding. Then our algorithm was used to CT scan images of 30 patients and the results were compared with those made by experts. Results: Experiments on clinical 2-D pulmonary images showed the results of our algorithm were very close to the expert’s manual outlines, and it was very effective for the separation of left and right lungs with a successful segmentation ratio 94.8%. Conclusion: It is a practicable fast lung segmentation algorithm for CAD system on thoracic CT image.