Hydrostatic slipper was often used in friction bearing design, allowing improvement of the latter's dynamic behavior. The influence of thermal effect on hydrostatic slipper bearing capacity of axial piston pump wa...Hydrostatic slipper was often used in friction bearing design, allowing improvement of the latter's dynamic behavior. The influence of thermal effect on hydrostatic slipper bearing capacity of axial piston pump was investigated. A set of lumped parameter mathematical models were developed based on energy conservation law of slipper/ swash plate pair. The results show that thermal equilibrium clearance due to solid thermal deformation periodically changes with shaft rotational angle. The slipper bearing capacity increases dramatically with decreasing thermal equilibrium clearance. In order to improve the slipper bearing capacity, length-to-diameter ratio of fixed damper varies from 3.5 to 8.75 and radius ratio of slipper varies from 1.5 to 2.0. In addition, the higher slipper thermal conductivity is useful to improve slipper bearing capability, but the thermal equilibrium clearance is not compromised.展开更多
At pesent, it is very popular to estimate pile bearing capacity by use of empirical formula and physical indexes of soil provided in the design codes for civil construction in China. This paper attempts to apply mecha...At pesent, it is very popular to estimate pile bearing capacity by use of empirical formula and physical indexes of soil provided in the design codes for civil construction in China. This paper attempts to apply mechanical indexes of soil and semi-empirical formulas, which are based on soil mechanical theories and were summarized and presented by Meyerhof in 1976, to calculate the axial pile bearing capacity. Loading test results of 24 single piles in Tianjin area have been collected and compared with the proposed calulation approach.展开更多
The effects of ground subsidence and piled spacing on axial force of piles in squared piled rafts were investigated using numerical analysis. Two cases of piled rafts in soft clay including case 1 (s = 2d) and case 2 ...The effects of ground subsidence and piled spacing on axial force of piles in squared piled rafts were investigated using numerical analysis. Two cases of piled rafts in soft clay including case 1 (s = 2d) and case 2 (s = 4d) with s and d were piled spacing and piled diameter respectively were considered in this study. Undrained (without ground water pumping) and drained (with ground water pumping) conditions were applied in each case in order to evaluate variations of ultimate bearing capacity of piled raft and axial force of the piles in piled raft. The results showed that ultimate bearing capacity increased about 25% for undrained condition and about 32% for drained condition when piled spacing increased from 2d to 4d. In the same piled spacing, axial force of the piles increased about 9% for piled spacing of 2d and 7% for piled spacing of 4d when drained condition was applied. When piled spacing increased 2 times (2d to 4d), the axial force of piles increased about 7% for undrained condition and about 5% for drained condition.展开更多
A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the...A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the non-uniform distribution of ultimate stress in cored concrete.The accuracy of the analytical result is validated through running the numerical result by finite element method (FEM) and experimental data as well.The influences of the key parameters on the load capacity of the concrete-filled steel tube (CFST) was studied,including the separation ratio,concrete compressive strength,and steel strength.The results indicate that the load capacity of the tube increases with concrete strength and steel strength under the separation ratio less than 4%,while decreases with a higher separation ratio improved.展开更多
The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concret...The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns.展开更多
This paper aims to deal with the assessment of axial load capacity for cast in place pile foundations, which are made by the earth drill method, by using the data taken from Standard Penetration Tests (SPTs) and Piezo...This paper aims to deal with the assessment of axial load capacity for cast in place pile foundations, which are made by the earth drill method, by using the data taken from Standard Penetration Tests (SPTs) and Piezocone Penetration Tests (CPTUs). These tests were carried out as part of the investigation program for P.N.G. Terminal-Power Plant, near Semani beach, in Hoxhara marsh, in the western part of Albania. The design of axial load capacity of piles is based on empirical formula using SPT and CPTU values. This study presents the results of axial load capacity analysis of cast in place piles by different analytical calculation methods, which are based on in situ tests results, and also referring to the Building Standard Law of Japan. In the end of our work, differences between calculations methods by using different in situ tests results are shown in tables and graphs.展开更多
Construction of tunnels in urban areas requires assessment of the impact of tunneling on the stability and integrity of existing pile foundations. We have focused our attention to the analysis of the carrying capacity...Construction of tunnels in urban areas requires assessment of the impact of tunneling on the stability and integrity of existing pile foundations. We have focused our attention to the analysis of the carrying capacity of pile foundations provided by the impact of construction of urban tunnels on adjacent pile foundations, under the engineering background of the construction of the # 2 Line of the Guangzhou subway. It is carried out using a fast Lagrangian analysis of a continuum in a 3D numerical code, which is an elastoplastic three-dimensional finite difference model, to simulate the response of piles under the entire process of metro tunneling (deactivation of soil element and activation of the lining). The adjacent stratum around the tunnel is classified into three regions: Zone Ⅰ (upper adjacent stratum of tunnel), Zone Ⅱ (45°-upper-lateral adjacent stratum of tunnel) and Zone Ⅲ (lateral adjacent stratum of tunnel). In each region one typical pile is chosen to be calculated and analyzed in detail. Numerical simulations are mainly conducted at three points of each pile shaft: the side-friction force of the pile, the tip resistance of the pile and the axial loading of the pile. A contrasting analysis has been conducted both in the response of typical piles in different regions and from computer calculated values with site monitoring values. The results of numerical simulations show that the impact on carrying capacity of the piles lies mainly in the impact of construction of urban tunnels on the side-friction forces and the tip resistance of piles. The impact differs considerably among the different strata zones where the pile tips are located. The complicated rules of side-friction force and tip resistance of piles has resulted in complicated rules of pile axial loading thus, in the end, it impacts the carrying capacity of pile-foundations. It is necessary to take positive measures, such as stratum grouting stabilization or foundation underpinning, etc, to deal with the carrying capacity and the settlement of pile-foundations. The results are of value to similar engineering projects.展开更多
Clearance not only affects the startup torque,rotation precision and stiffness of bearing,but also affects the load distribution,load-carrying capacity and life of bearing.A computational model in which the clearance ...Clearance not only affects the startup torque,rotation precision and stiffness of bearing,but also affects the load distribution,load-carrying capacity and life of bearing.A computational model in which the clearance of bearing is first included is presented for determining the contact force distribution and static load-carrying capacity of a double row four-point contact ball bearing which is subjected to the combined radial,axial and overturning moment loadings.The relation between the negative axial clearance and the contact force distribution is analyzed.The static load-carrying capacity curves are established,and the effects of the changes in negative axial clearance,curvature radius coefficient of raceway groove and initial contact angle on the static load-carrying capacity are analyzed.The results show that,with the increase in the absolute value of negative clearance,the maximum contact load decreases first and then increases.The clearance values in the range of 0.2 mme0 mm have little effect on the static load-carrying capacity of bearing.With the increase in the curvature radius coefficient of raceway groove and the decrease in the initial contact angle,the static load capacity of bearing decreases.展开更多
An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of ...An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures.展开更多
Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular c...Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular columns. The analysis reveals that smaller axial load ratio can improve the shear bearing capacity and ductility while larger axial load ratio will decrease the shear behavior of the through-diaphragm connections. The parametric studies indicate that the axial load ratio should be limited to less than 0.4 and its influence should be considered in the analysis and design of such connections.展开更多
In order to find out the bearing behavior of super-long piles located in deep soft clay over stiff layers around Dongting Lake, China, a test pile was first designed with the field loading test finished afterward. Bas...In order to find out the bearing behavior of super-long piles located in deep soft clay over stiff layers around Dongting Lake, China, a test pile was first designed with the field loading test finished afterward. Based on the measured test results, load transfer mechanism and bearing behavior of the pile shaft were discussed in detail. Then, by introducing a bi-linear model for shaft friction and the tri-linear model for pile tip resistance, respectively, the governing differential equation of pile soil system was set up by the load transfer method with the analytical solutions derived as well, taking into account the effect by stratified feature and various bearing conditions of subsoil, material nonlinearity, and the sediment under pile tip. Furthermore, formulas to determine the axial capacity of super-long piles by the pile top settlement were advised and applied to analyze the test pile. Good agreement between the predicted load settlement variations and the measured data is obtained to verify the validity of the present method. The results also show that, the axial bearing capacity of super-long piles should be controlled by the allowable pile top settlement, and buckling stability of the pile shaft should be paid attention as well.展开更多
Different techniques have been proposed to increase the bearing capacity of open-ended piles.Welding helices to the shaft and tapering the pile shaft could be used simultaneously to enhance the static and dynamic beha...Different techniques have been proposed to increase the bearing capacity of open-ended piles.Welding helices to the shaft and tapering the pile shaft could be used simultaneously to enhance the static and dynamic behaviors of these piles.This paper subjects the bearing capacity,stiffness,frictional behavior,and material efficiency of the tapered helical piles to scrutiny.Tapered helical piles are introduced herein as an alternative option to improve the material efficiency of hollow piles.Based on the Taguchi method,a series of experiments was designed and conducted.The axial responses of tapered helical piles are also investigated using finite element analyses.The results derived from loadedisplacement curves and strain gages are used to characterize the axial compression responses of tapered helical piles.The effects of tapered angle,helices diameter and helices distance are examined using dimensionless parameters,and the degree of contribution of these factors is calculated on each of the enumerated variables individually.Experimental results show that the shaft friction resistance of tapered helical piles increases continuously with the pile head settlement.Furthermore,the effect of tapered wall on the shaft friction resistance is more tangible at low stress levels.The results showed that the relative material efficiency factor of the optimum pile could be 2.5 times that of unoptimized pile with a similar quantity of material.展开更多
In order to study the axial compression performances of short columns made of recycled aggregate concrete,four samples were designed with different recycled aggregate replacement rates and carbon fibre reinforced plas...In order to study the axial compression performances of short columns made of recycled aggregate concrete,four samples were designed with different recycled aggregate replacement rates and carbon fibre reinforced plastics(CFRP)sheets.Then,monotonic loading was implemented to assess the variation trends of their axial compression properties.The ABAQUS finite element software was also used to determined the compression performances.Good agreement between experimental and numerical results has been found for the different parameters being considered.As shown by the results,recycled coarse aggregates result in improved ductility and better deformation performance of the specimens.The failure of specimens caused by pre damage can be compensated by using CFRP sheets,by which both the resistance to deformation and the axial carrying capacity of columns can be increased.展开更多
A novel transit-time oscillator(TTO)is proposed in this paper.An axial cathode which has been widely used in high power microwave(HPM)source and an extractor with radial feature are adopted.In this way,the inherent ad...A novel transit-time oscillator(TTO)is proposed in this paper.An axial cathode which has been widely used in high power microwave(HPM)source and an extractor with radial feature are adopted.In this way,the inherent advantages of axial and radial TTO,both of which can be utilized as high-quality intense relativistic electron beam(IREB),can be generated and the power capacity is also increased.The working mode isπ/2 mode of TM01 based on small-signal theory,and under the same energy storage,the maximum electric field in extractor decreases 16.3%.Besides,by utilizing the natural bending of the solenoid,this TTO saves over 60%of the length required by the uniform magnetic field,and consequently reduces the energy consumed by solenoid.The PIC simulation shows that by using 1.0-T decreasing magnetic field generated by the shorter solenoid,3.37-GW microwave at 12.43 GHz is generated with 620-kV and 13.27-kA input,and the overall conversion efficiency is 41%.展开更多
The effect of tip-blade cutting on the performance of a large scale axial fan was investigated using computational fluid dynamics(CFD)methods.Experiments verified the numerical simulations.The original fan was compare...The effect of tip-blade cutting on the performance of a large scale axial fan was investigated using computational fluid dynamics(CFD)methods.Experiments verified the numerical simulations.The original fan was compared with the one with tip-cutting in terms of dimensionless characteristic and aerodynamic performance in tip region under the conditions of the maximum efficiency point and near-stall point.The results showed that double leakage flow occurred in tip clearance at maximum efficiency point and spillage of leakage flow from leading edge occurred in tip-blade region at near-stall point for the both two fans;and that tip-cutting with 6% of blade height could reduce the intensity of tip-leakage vortex and increase flow capacity in tip blade region,and hold the stall margin almost the same as the original fan.The maximum efficiency of the fan with tip-cutting was improved by1%,and the ability of total pressure rising was obviously greater than the original fan.展开更多
The static tests of nine traditional and bird beak square hollow structure(SHS) T-joints with different β values and connection types under axial compression at brace end were carried out. Experimental test schemes, ...The static tests of nine traditional and bird beak square hollow structure(SHS) T-joints with different β values and connection types under axial compression at brace end were carried out. Experimental test schemes, failure modes of specimens, jack load-vertical displacement curves, jack load-deformation of chord and strain intensity distribution curves of joints were presented. The effects of β and connection types on axial compression property of joints were studied. The results show that the ultimate axial compression capacity of common bird beak SHS T-joints and diamond bird beak SHS T-joints is larger than that of traditional SHS T-joint specimens with big values of β. The ultimate axial compression capacity of diamond bird beak SHS T-joints is larger than that of common bird beak SHS T-joints. As β increases, the increase of the ultimate axial compression capacity of diamond bird beak SHS T-joints over that of common bird beak joints grows. The ultimate axial compression capacity and the initial axial stiffness of all kinds of joints increase as β increases, and the initial axial stiffness of the diamond bird beak SHS T-joints is the largest. The ductilities of common bird beak and diamond bird beak SHS T-joints increase as β increases, but the ductility of the traditional SHS T-joints decreases as β increases.展开更多
基金Projects(51475332,51275356)supported by the National Natural Science Foundation of China
文摘Hydrostatic slipper was often used in friction bearing design, allowing improvement of the latter's dynamic behavior. The influence of thermal effect on hydrostatic slipper bearing capacity of axial piston pump was investigated. A set of lumped parameter mathematical models were developed based on energy conservation law of slipper/ swash plate pair. The results show that thermal equilibrium clearance due to solid thermal deformation periodically changes with shaft rotational angle. The slipper bearing capacity increases dramatically with decreasing thermal equilibrium clearance. In order to improve the slipper bearing capacity, length-to-diameter ratio of fixed damper varies from 3.5 to 8.75 and radius ratio of slipper varies from 1.5 to 2.0. In addition, the higher slipper thermal conductivity is useful to improve slipper bearing capability, but the thermal equilibrium clearance is not compromised.
文摘At pesent, it is very popular to estimate pile bearing capacity by use of empirical formula and physical indexes of soil provided in the design codes for civil construction in China. This paper attempts to apply mechanical indexes of soil and semi-empirical formulas, which are based on soil mechanical theories and were summarized and presented by Meyerhof in 1976, to calculate the axial pile bearing capacity. Loading test results of 24 single piles in Tianjin area have been collected and compared with the proposed calulation approach.
文摘The effects of ground subsidence and piled spacing on axial force of piles in squared piled rafts were investigated using numerical analysis. Two cases of piled rafts in soft clay including case 1 (s = 2d) and case 2 (s = 4d) with s and d were piled spacing and piled diameter respectively were considered in this study. Undrained (without ground water pumping) and drained (with ground water pumping) conditions were applied in each case in order to evaluate variations of ultimate bearing capacity of piled raft and axial force of the piles in piled raft. The results showed that ultimate bearing capacity increased about 25% for undrained condition and about 32% for drained condition when piled spacing increased from 2d to 4d. In the same piled spacing, axial force of the piles increased about 9% for piled spacing of 2d and 7% for piled spacing of 4d when drained condition was applied. When piled spacing increased 2 times (2d to 4d), the axial force of piles increased about 7% for undrained condition and about 5% for drained condition.
基金Projects(51078093,11272095)supported by the National Natural Science Foundation of ChinaProjects(2011B010300026,2012B04032005)supported by Guangdong Science and Technology Project,China+1 种基金Project(2011Y2-00006)supported by Guangzhou City Science and Technology Research Project,ChinaProject(2012CXZD0028)supported by the Science and Technology Innovation Projects of Department of Education of Guangdong Province,China
文摘A new calculation method for axial load capacity of separated concrete-filled steel tubes based on limit equilibrium theory was proposed,which took into account the decrease of confinement effect by steel tube and the non-uniform distribution of ultimate stress in cored concrete.The accuracy of the analytical result is validated through running the numerical result by finite element method (FEM) and experimental data as well.The influences of the key parameters on the load capacity of the concrete-filled steel tube (CFST) was studied,including the separation ratio,concrete compressive strength,and steel strength.The results indicate that the load capacity of the tube increases with concrete strength and steel strength under the separation ratio less than 4%,while decreases with a higher separation ratio improved.
文摘The application of artificial neural network to predict the ultimate bearing capacity of CFST ( concrete-filled square steel tubes) short columns under axial loading is explored. Input parameters consiste of concrete compressive strength, yield strength of steel tube, confinement index, sectional dimension and width-to-thickness ratio. The ultimate bearing capacity is the only output parameter. A multilayer feedforward neural network is used to describe the nonlinear relationships between the input and output variables. Fifty-five experimental data of CFST short columns under axial loading are used to train and test the neural network. A comparison between the neural network model and three parameter models shows that the neural network model possesses good accuracy and could be a practical method for predicting the ultimate strength of axially loaded CFST short columns.
文摘This paper aims to deal with the assessment of axial load capacity for cast in place pile foundations, which are made by the earth drill method, by using the data taken from Standard Penetration Tests (SPTs) and Piezocone Penetration Tests (CPTUs). These tests were carried out as part of the investigation program for P.N.G. Terminal-Power Plant, near Semani beach, in Hoxhara marsh, in the western part of Albania. The design of axial load capacity of piles is based on empirical formula using SPT and CPTU values. This study presents the results of axial load capacity analysis of cast in place piles by different analytical calculation methods, which are based on in situ tests results, and also referring to the Building Standard Law of Japan. In the end of our work, differences between calculations methods by using different in situ tests results are shown in tables and graphs.
文摘Construction of tunnels in urban areas requires assessment of the impact of tunneling on the stability and integrity of existing pile foundations. We have focused our attention to the analysis of the carrying capacity of pile foundations provided by the impact of construction of urban tunnels on adjacent pile foundations, under the engineering background of the construction of the # 2 Line of the Guangzhou subway. It is carried out using a fast Lagrangian analysis of a continuum in a 3D numerical code, which is an elastoplastic three-dimensional finite difference model, to simulate the response of piles under the entire process of metro tunneling (deactivation of soil element and activation of the lining). The adjacent stratum around the tunnel is classified into three regions: Zone Ⅰ (upper adjacent stratum of tunnel), Zone Ⅱ (45°-upper-lateral adjacent stratum of tunnel) and Zone Ⅲ (lateral adjacent stratum of tunnel). In each region one typical pile is chosen to be calculated and analyzed in detail. Numerical simulations are mainly conducted at three points of each pile shaft: the side-friction force of the pile, the tip resistance of the pile and the axial loading of the pile. A contrasting analysis has been conducted both in the response of typical piles in different regions and from computer calculated values with site monitoring values. The results of numerical simulations show that the impact on carrying capacity of the piles lies mainly in the impact of construction of urban tunnels on the side-friction forces and the tip resistance of piles. The impact differs considerably among the different strata zones where the pile tips are located. The complicated rules of side-friction force and tip resistance of piles has resulted in complicated rules of pile axial loading thus, in the end, it impacts the carrying capacity of pile-foundations. It is necessary to take positive measures, such as stratum grouting stabilization or foundation underpinning, etc, to deal with the carrying capacity and the settlement of pile-foundations. The results are of value to similar engineering projects.
基金supported by NSFC(51105131)Excellent Youth Foundation of Henan Scientific Committee(124100510002)Creative Talent Foundation in University of Henan Province(2011HASTIT016)
文摘Clearance not only affects the startup torque,rotation precision and stiffness of bearing,but also affects the load distribution,load-carrying capacity and life of bearing.A computational model in which the clearance of bearing is first included is presented for determining the contact force distribution and static load-carrying capacity of a double row four-point contact ball bearing which is subjected to the combined radial,axial and overturning moment loadings.The relation between the negative axial clearance and the contact force distribution is analyzed.The static load-carrying capacity curves are established,and the effects of the changes in negative axial clearance,curvature radius coefficient of raceway groove and initial contact angle on the static load-carrying capacity are analyzed.The results show that,with the increase in the absolute value of negative clearance,the maximum contact load decreases first and then increases.The clearance values in the range of 0.2 mme0 mm have little effect on the static load-carrying capacity of bearing.With the increase in the curvature radius coefficient of raceway groove and the decrease in the initial contact angle,the static load capacity of bearing decreases.
基金Project(51078294)supported by the National Natural Science Foundation of ChinaProject(201101411100025)supported by the Doctoral Fund of Ministry of Education of China
文摘An experimental study on the compressive behavior of steel fiber reinforced concrete-filled steel tube columns is presented. Specimens were tested to investigate the effects of the concrete strength, the thickness of steel tube and the steel fiber volume fraction on the ultimate strength and the ductility. The experimental results indicate that the addition of steel fibers in concrete can significantly improve the ductility and the energy dissipation capacity of the concrete-filled steel tube columns and delay the local buckling of the steel tube, but has no obvious effect on the failure mode. It has also been found that the addition of steel fibers is a more effective method than using thicker steel tube in enhancing the ductility, and more advantageous in the case of higher strength concrete. An analytical model to estimate the load capacity is proposed for steel tube columns filled with both plain concrete and steel fiber reinforced concrete. The predicted results are in good agreement with the experimental ones obtained in this work and literatures.
基金Supported by the National Natural Science Foundation of China(No.51268054 and No.51468061)the Natural Science Foundation of Tianjin(No.13JCQNJC07300)Foundation of Xinjiang University(No.XY110137)
文摘Nonlinear finite element analysis and parametric studies were carried out to study the influence of axial load ratio on the shear behavior of the through-diaphragm connections of concrete-filled square steel tubular columns. The analysis reveals that smaller axial load ratio can improve the shear bearing capacity and ductility while larger axial load ratio will decrease the shear behavior of the through-diaphragm connections. The parametric studies indicate that the axial load ratio should be limited to less than 0.4 and its influence should be considered in the analysis and design of such connections.
基金Project(50908084)supported by the National Natural Science Foundation of ChinaProject(200815)supported by the Transportation Science and Technology Program of Hunan Province,ChinaProject(531107040620)supported by the Growth Plan for Young Teachers of Hunan University,China
文摘In order to find out the bearing behavior of super-long piles located in deep soft clay over stiff layers around Dongting Lake, China, a test pile was first designed with the field loading test finished afterward. Based on the measured test results, load transfer mechanism and bearing behavior of the pile shaft were discussed in detail. Then, by introducing a bi-linear model for shaft friction and the tri-linear model for pile tip resistance, respectively, the governing differential equation of pile soil system was set up by the load transfer method with the analytical solutions derived as well, taking into account the effect by stratified feature and various bearing conditions of subsoil, material nonlinearity, and the sediment under pile tip. Furthermore, formulas to determine the axial capacity of super-long piles by the pile top settlement were advised and applied to analyze the test pile. Good agreement between the predicted load settlement variations and the measured data is obtained to verify the validity of the present method. The results also show that, the axial bearing capacity of super-long piles should be controlled by the allowable pile top settlement, and buckling stability of the pile shaft should be paid attention as well.
文摘Different techniques have been proposed to increase the bearing capacity of open-ended piles.Welding helices to the shaft and tapering the pile shaft could be used simultaneously to enhance the static and dynamic behaviors of these piles.This paper subjects the bearing capacity,stiffness,frictional behavior,and material efficiency of the tapered helical piles to scrutiny.Tapered helical piles are introduced herein as an alternative option to improve the material efficiency of hollow piles.Based on the Taguchi method,a series of experiments was designed and conducted.The axial responses of tapered helical piles are also investigated using finite element analyses.The results derived from loadedisplacement curves and strain gages are used to characterize the axial compression responses of tapered helical piles.The effects of tapered angle,helices diameter and helices distance are examined using dimensionless parameters,and the degree of contribution of these factors is calculated on each of the enumerated variables individually.Experimental results show that the shaft friction resistance of tapered helical piles increases continuously with the pile head settlement.Furthermore,the effect of tapered wall on the shaft friction resistance is more tangible at low stress levels.The results showed that the relative material efficiency factor of the optimum pile could be 2.5 times that of unoptimized pile with a similar quantity of material.
文摘In order to study the axial compression performances of short columns made of recycled aggregate concrete,four samples were designed with different recycled aggregate replacement rates and carbon fibre reinforced plastics(CFRP)sheets.Then,monotonic loading was implemented to assess the variation trends of their axial compression properties.The ABAQUS finite element software was also used to determined the compression performances.Good agreement between experimental and numerical results has been found for the different parameters being considered.As shown by the results,recycled coarse aggregates result in improved ductility and better deformation performance of the specimens.The failure of specimens caused by pre damage can be compensated by using CFRP sheets,by which both the resistance to deformation and the axial carrying capacity of columns can be increased.
基金Project supported by the National Natural Science Foundation of China(Grant No.61701516)
文摘A novel transit-time oscillator(TTO)is proposed in this paper.An axial cathode which has been widely used in high power microwave(HPM)source and an extractor with radial feature are adopted.In this way,the inherent advantages of axial and radial TTO,both of which can be utilized as high-quality intense relativistic electron beam(IREB),can be generated and the power capacity is also increased.The working mode isπ/2 mode of TM01 based on small-signal theory,and under the same energy storage,the maximum electric field in extractor decreases 16.3%.Besides,by utilizing the natural bending of the solenoid,this TTO saves over 60%of the length required by the uniform magnetic field,and consequently reduces the energy consumed by solenoid.The PIC simulation shows that by using 1.0-T decreasing magnetic field generated by the shorter solenoid,3.37-GW microwave at 12.43 GHz is generated with 620-kV and 13.27-kA input,and the overall conversion efficiency is 41%.
基金supported by the Specialized Research Fund for the Doctoral Program of Higher Education (No. 20113218120006)
文摘The effect of tip-blade cutting on the performance of a large scale axial fan was investigated using computational fluid dynamics(CFD)methods.Experiments verified the numerical simulations.The original fan was compared with the one with tip-cutting in terms of dimensionless characteristic and aerodynamic performance in tip region under the conditions of the maximum efficiency point and near-stall point.The results showed that double leakage flow occurred in tip clearance at maximum efficiency point and spillage of leakage flow from leading edge occurred in tip-blade region at near-stall point for the both two fans;and that tip-cutting with 6% of blade height could reduce the intensity of tip-leakage vortex and increase flow capacity in tip blade region,and hold the stall margin almost the same as the original fan.The maximum efficiency of the fan with tip-cutting was improved by1%,and the ability of total pressure rising was obviously greater than the original fan.
基金Projects(51278209,51478047)supported by the National Natural Science Foundation of ChinaProject(2014FJ-NCET-ZR03)supported by the Program for New Century Excellent Talents in Fujian Provincial Universities,China+1 种基金Project(JA13005)supported by the Incubation Program for Excellent Young Science and Technology Talents in Fujian Provincial Universities,ChinaProject(ZQN-PY110)supported by the Young and Middle-aged Academic Staff of Huaqiao University,China
文摘The static tests of nine traditional and bird beak square hollow structure(SHS) T-joints with different β values and connection types under axial compression at brace end were carried out. Experimental test schemes, failure modes of specimens, jack load-vertical displacement curves, jack load-deformation of chord and strain intensity distribution curves of joints were presented. The effects of β and connection types on axial compression property of joints were studied. The results show that the ultimate axial compression capacity of common bird beak SHS T-joints and diamond bird beak SHS T-joints is larger than that of traditional SHS T-joint specimens with big values of β. The ultimate axial compression capacity of diamond bird beak SHS T-joints is larger than that of common bird beak SHS T-joints. As β increases, the increase of the ultimate axial compression capacity of diamond bird beak SHS T-joints over that of common bird beak joints grows. The ultimate axial compression capacity and the initial axial stiffness of all kinds of joints increase as β increases, and the initial axial stiffness of the diamond bird beak SHS T-joints is the largest. The ductilities of common bird beak and diamond bird beak SHS T-joints increase as β increases, but the ductility of the traditional SHS T-joints decreases as β increases.