In partially premixed combustion of gas turbine, the combustion temperature should be lowed in order to reduce NOx. One solution is lean premixed combustion. However, the problem is that large excess air ratio may mak...In partially premixed combustion of gas turbine, the combustion temperature should be lowed in order to reduce NOx. One solution is lean premixed combustion. However, the problem is that large excess air ratio may make the combustion unstable. A novel combustor with circumferential reverse flow of fuel gas is proposed for settling this problem. A 10 kw furnace is established to test performance of this combustor. Three factors such as primary air ratio, position of secondary air, total excess air ratio are studied. The emission characteristics and axial flame temperature distribution are studied. Basing on experimental results, the axial flame temperature and NOr emission increase with primary air ratio and axial length of second stream, and decrease with total excess air ratio. When the total excess air ratio is larger than 1.05, the combustor presents a lower temperature field and much lower NOx emission (less than 10 ppm).展开更多
A temperature control system of 31m vertical forced air-circulation quench furnace is proposed, which is a kind of equipment critical for thermal treatment of aluminum alloy components that are widely used in aerospac...A temperature control system of 31m vertical forced air-circulation quench furnace is proposed, which is a kind of equipment critical for thermal treatment of aluminum alloy components that are widely used in aerospace industry. For the effective operation of the furnace, it is essential to analyze the radial temperature distribution of the furnace. A set of thermodynamic balance equations modeling is established firsdy. By utilizing the numerical analysis result to modify the temperature measurements, the control accuracy and precision of the temperature are truly guaranteed. Furthermore, the multivariable decoupling self-learning PID control algorithm based on the characteristics of strong coupling between the multi-zones in the large-scaled furnace is implemented to ensure the true homogeneity of the axial temperature distribution. Finally, the redundant structure composed of industrial control computers and touch panels leads to great improvement of system reliability.展开更多
An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and...An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and 45°. The results of the temperature profile across the air gap showed that heat transfer from the absorber plate to the air stream was mainly by convection. At a particular section, mean air temperature could be calculated from the arithmetic mean of the temperature profile across the air gap to within ± 2 ℃. The axial air temperature distribution was non linear and did not increase much beyond 1 m of collector length. It tended to decrease towards the end of the collector. Overall glass, absorber plate and mean air temperatures over the entire length of the solar air heater could be determined by averaging the mean axial temperatures to within ± 2 ℃. The heater performed better as inclination increased.展开更多
Effect of higher order axial electron temperature on self-focusing of electromagnetic pulsed beam in collisional plasma is investigated.It is shown that higher order axial electron temperature T p4 is not trivial than...Effect of higher order axial electron temperature on self-focusing of electromagnetic pulsed beam in collisional plasma is investigated.It is shown that higher order axial electron temperature T p4 is not trivial than T p0 and T p2,which can modify slightly radial redistribution of electron density and increases effective dielectric constant.As a result,on one hand,slightly reduce electromagnetic beam self-focusing in the course of oscillatory convergence,on the other hand,quicken beam divergence in the course of steady divergence,i.e.,higher order axial electron temperature T p4 can decrease the influence of collisional nonlinearity in collisional plasma.展开更多
In this Letter, an alternative solution is proposed and demonstrated for simultaneous measurement of axial strain and temperature. This sensor consists of two twisted points on a commercial single mode fiber introduce...In this Letter, an alternative solution is proposed and demonstrated for simultaneous measurement of axial strain and temperature. This sensor consists of two twisted points on a commercial single mode fiber introduced by flame-heated and rotation treatment. The fabrication process modifies the geometrical configuration and refractive index of the fiber. Different cladding modes are excited at the first twisted point, and part of them are coupled back to the fiber core at the second twisted point. Experimental results show distinct sensitivities of 34.9 pm/με with 49.23 pm/℃ and -36.19 pm/με with 62.99 pm/℃ for the two selected destructive interference wavelengths.展开更多
We simulated three-dimensional heat transfer inside a horizontal rotating drum using the discrete element method and a thermal conduction model.The aim was to determine the effect of end-wall heating on thermal behavi...We simulated three-dimensional heat transfer inside a horizontal rotating drum using the discrete element method and a thermal conduction model.The aim was to determine the effect of end-wall heating on thermal behavior of a granular bed.The simulation showed that the end-wall heating significantly affects the axial temperature profile of the bed,particularly when the length-to-diameter ratio is low.Particles near the wall heated faster and became more thermally uniform than those in the center of the drum.The region affected by the end heating gradually increased over time.Increasing the rotation speed enhanced the heat conduction rate,and increasing the fill level reduced the mean temperature and thermal uniformity of the granular bed.Heat transfer was also simulated for drums with different length-to-diameter ratios.展开更多
文摘In partially premixed combustion of gas turbine, the combustion temperature should be lowed in order to reduce NOx. One solution is lean premixed combustion. However, the problem is that large excess air ratio may make the combustion unstable. A novel combustor with circumferential reverse flow of fuel gas is proposed for settling this problem. A 10 kw furnace is established to test performance of this combustor. Three factors such as primary air ratio, position of secondary air, total excess air ratio are studied. The emission characteristics and axial flame temperature distribution are studied. Basing on experimental results, the axial flame temperature and NOr emission increase with primary air ratio and axial length of second stream, and decrease with total excess air ratio. When the total excess air ratio is larger than 1.05, the combustor presents a lower temperature field and much lower NOx emission (less than 10 ppm).
基金It was supported by the National Natural Science Foundation of China (No. 59835170).
文摘A temperature control system of 31m vertical forced air-circulation quench furnace is proposed, which is a kind of equipment critical for thermal treatment of aluminum alloy components that are widely used in aerospace industry. For the effective operation of the furnace, it is essential to analyze the radial temperature distribution of the furnace. A set of thermodynamic balance equations modeling is established firsdy. By utilizing the numerical analysis result to modify the temperature measurements, the control accuracy and precision of the temperature are truly guaranteed. Furthermore, the multivariable decoupling self-learning PID control algorithm based on the characteristics of strong coupling between the multi-zones in the large-scaled furnace is implemented to ensure the true homogeneity of the axial temperature distribution. Finally, the redundant structure composed of industrial control computers and touch panels leads to great improvement of system reliability.
文摘An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and 45°. The results of the temperature profile across the air gap showed that heat transfer from the absorber plate to the air stream was mainly by convection. At a particular section, mean air temperature could be calculated from the arithmetic mean of the temperature profile across the air gap to within ± 2 ℃. The axial air temperature distribution was non linear and did not increase much beyond 1 m of collector length. It tended to decrease towards the end of the collector. Overall glass, absorber plate and mean air temperatures over the entire length of the solar air heater could be determined by averaging the mean axial temperatures to within ± 2 ℃. The heater performed better as inclination increased.
文摘Effect of higher order axial electron temperature on self-focusing of electromagnetic pulsed beam in collisional plasma is investigated.It is shown that higher order axial electron temperature T p4 is not trivial than T p0 and T p2,which can modify slightly radial redistribution of electron density and increases effective dielectric constant.As a result,on one hand,slightly reduce electromagnetic beam self-focusing in the course of oscillatory convergence,on the other hand,quicken beam divergence in the course of steady divergence,i.e.,higher order axial electron temperature T p4 can decrease the influence of collisional nonlinearity in collisional plasma.
基金supported by the National Natural Science Foundation of China(Nos.61775070 and 61275083)the Fundamental Research Funds for the Central Universities(No.2017KFYXJJ032)
文摘In this Letter, an alternative solution is proposed and demonstrated for simultaneous measurement of axial strain and temperature. This sensor consists of two twisted points on a commercial single mode fiber introduced by flame-heated and rotation treatment. The fabrication process modifies the geometrical configuration and refractive index of the fiber. Different cladding modes are excited at the first twisted point, and part of them are coupled back to the fiber core at the second twisted point. Experimental results show distinct sensitivities of 34.9 pm/με with 49.23 pm/℃ and -36.19 pm/με with 62.99 pm/℃ for the two selected destructive interference wavelengths.
文摘We simulated three-dimensional heat transfer inside a horizontal rotating drum using the discrete element method and a thermal conduction model.The aim was to determine the effect of end-wall heating on thermal behavior of a granular bed.The simulation showed that the end-wall heating significantly affects the axial temperature profile of the bed,particularly when the length-to-diameter ratio is low.Particles near the wall heated faster and became more thermally uniform than those in the center of the drum.The region affected by the end heating gradually increased over time.Increasing the rotation speed enhanced the heat conduction rate,and increasing the fill level reduced the mean temperature and thermal uniformity of the granular bed.Heat transfer was also simulated for drums with different length-to-diameter ratios.