A 3D temperature field reconstruction method using the colored background oriented schlieren(CBOS)method is proposed to address image blurring due to the different refractive index of the multi-wavelength light and si...A 3D temperature field reconstruction method using the colored background oriented schlieren(CBOS)method is proposed to address image blurring due to the different refractive index of the multi-wavelength light and significant errors produced when the traditional background oriented schlieren(BOS)method is applied to high-temperature gas.First,the traditional method is employed to reconstruct the non-uniform 3D temperature field.Second,the CBOS method is applied to correct the distortion.Then,by analyzing the correlation coefficient among different color points of the colored background pattern,the non-uniform temperature field is reconstructed much more accurately.Finally,the experimental results are verified by applying the Runge-Kutta ray-tracing method and the thermocouple contact measurement method.The maximum average temperature error of the CBOS-reconstructed temperature field is 12.92°C,compared with the thermocouples.Therefore,an accurate three-dimensional reconstruction of the temperature field can be achieved by the proposed method effectively.展开更多
For the measurement of X-ray energy spectrum with filter-fluorescer method,the high energy tail at the rearward of response function is the main source of background.There are,traditionally,two techniques for measurin...For the measurement of X-ray energy spectrum with filter-fluorescer method,the high energy tail at the rearward of response function is the main source of background.There are,traditionally,two techniques for measuring the background contributions:the same element Z for the fluorescer and filter,or the same element Z?1 for them.Using the formula of fluorescence intensity,and the elemental combinations of cobalt and iron,the backgrounds which the two techniques provide and the real one for measuring black-body radiation at equilibrium temperature of 7×106 K,were calculated.The results show that the Co-Co combination for the filter-fluorescer spectrometer can achieve better effect.A semi-quantitative analysis for the calculation results is discussed.展开更多
In the measurement of G with the angular acceleration method,the improved correlation method developed by Wu et al.(Wu W H,Tian Y,Luo J,Shao C G,Xu J H and Wang DH 2016 Rev.Sci.Instrum.87 094501) is used to accurate...In the measurement of G with the angular acceleration method,the improved correlation method developed by Wu et al.(Wu W H,Tian Y,Luo J,Shao C G,Xu J H and Wang DH 2016 Rev.Sci.Instrum.87 094501) is used to accurately estimate the amplitudes of the prominent harmonic components of the gravitational background signal with time-varying frequency.Except the quadratic slow drift,the angular frequency of the gravitational background signal also includes a cosine oscillation coming from the useful angular acceleration signal,which leads to a deviation from the estimated amplitude.We calculate the correction of the cosine oscillation to the amplitude estimation.The result shows that the corrections of the cosine oscillation to the amplitudes of the fundamental frequency and second harmonic components obtained by the improved correlation method are within respective errors.展开更多
An experimental system based on the background-oriented schlieren(BOS) technique is built to reconstruct the density and temperature distribution of a flame-induced distorted flow field which has a density gradient....An experimental system based on the background-oriented schlieren(BOS) technique is built to reconstruct the density and temperature distribution of a flame-induced distorted flow field which has a density gradient. The cross-correlation algorithm with sub-pixel accuracy is introduced and used to calculate the background-element displacement of a disturbed image and a fourth-order difference scheme is also developed to solve the Poisson equation. An experiment for a disturbed flow field caused by a burning candle is performed to validate the built BOS system and the results indicate that density and temperature distribution of the disturbed flow field can be reconstructed accurately. A notable conclusion is that in order to make the reconstructed results have a satisfactory accuracy, the inquiry step length should be less than the size of the interrogation window.展开更多
Using neutron activation analysis method we determined contents of rare-earth and radioactive elements (La, Ce, Nd, Sm, Eu, Tb, Yb, Lu, Cs, Rb, Sb, Sc, Sr, Ba, U, Th) in source water system of the Changjiang (Yangtze)...Using neutron activation analysis method we determined contents of rare-earth and radioactive elements (La, Ce, Nd, Sm, Eu, Tb, Yb, Lu, Cs, Rb, Sb, Sc, Sr, Ba, U, Th) in source water system of the Changjiang (Yangtze) River, which is mainly composed of the Tuotuo River, the Chumaer River, and the Buqu River. The contents of these elements in the unflltered water have a great variation and a close correlation with the water turbidity. The contents of these elements in filtered water only have a little variation and are lower than those in the unflltered water. The variations in contents of these elements in sediments are also very little. These elements in the unifiltered water are in geometric distribution, except Sc. Most of the elements in sediments are in arithmetic distribution, but Cs, Sb, Th, are in deviation distribution. The contents of most of these elements in the river source area correspond to the contents of fresh water of the earth. Most of these elements have a little variation in their展开更多
基金Supported by the National Natural Science Foundation of China(52005500)Foundation of Tianjin Educational Committee(2018KJ242)Basic Science-Research Funds of National University(3122019088)。
文摘A 3D temperature field reconstruction method using the colored background oriented schlieren(CBOS)method is proposed to address image blurring due to the different refractive index of the multi-wavelength light and significant errors produced when the traditional background oriented schlieren(BOS)method is applied to high-temperature gas.First,the traditional method is employed to reconstruct the non-uniform 3D temperature field.Second,the CBOS method is applied to correct the distortion.Then,by analyzing the correlation coefficient among different color points of the colored background pattern,the non-uniform temperature field is reconstructed much more accurately.Finally,the experimental results are verified by applying the Runge-Kutta ray-tracing method and the thermocouple contact measurement method.The maximum average temperature error of the CBOS-reconstructed temperature field is 12.92°C,compared with the thermocouples.Therefore,an accurate three-dimensional reconstruction of the temperature field can be achieved by the proposed method effectively.
文摘For the measurement of X-ray energy spectrum with filter-fluorescer method,the high energy tail at the rearward of response function is the main source of background.There are,traditionally,two techniques for measuring the background contributions:the same element Z for the fluorescer and filter,or the same element Z?1 for them.Using the formula of fluorescence intensity,and the elemental combinations of cobalt and iron,the backgrounds which the two techniques provide and the real one for measuring black-body radiation at equilibrium temperature of 7×106 K,were calculated.The results show that the Co-Co combination for the filter-fluorescer spectrometer can achieve better effect.A semi-quantitative analysis for the calculation results is discussed.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11575160,11175160,11275075,and 11511130011)
文摘In the measurement of G with the angular acceleration method,the improved correlation method developed by Wu et al.(Wu W H,Tian Y,Luo J,Shao C G,Xu J H and Wang DH 2016 Rev.Sci.Instrum.87 094501) is used to accurately estimate the amplitudes of the prominent harmonic components of the gravitational background signal with time-varying frequency.Except the quadratic slow drift,the angular frequency of the gravitational background signal also includes a cosine oscillation coming from the useful angular acceleration signal,which leads to a deviation from the estimated amplitude.We calculate the correction of the cosine oscillation to the amplitude estimation.The result shows that the corrections of the cosine oscillation to the amplitudes of the fundamental frequency and second harmonic components obtained by the improved correlation method are within respective errors.
基金supported by the Key Program of the National Natural Science Foundation of China(Grant No.NSFC 91441205)
文摘An experimental system based on the background-oriented schlieren(BOS) technique is built to reconstruct the density and temperature distribution of a flame-induced distorted flow field which has a density gradient. The cross-correlation algorithm with sub-pixel accuracy is introduced and used to calculate the background-element displacement of a disturbed image and a fourth-order difference scheme is also developed to solve the Poisson equation. An experiment for a disturbed flow field caused by a burning candle is performed to validate the built BOS system and the results indicate that density and temperature distribution of the disturbed flow field can be reconstructed accurately. A notable conclusion is that in order to make the reconstructed results have a satisfactory accuracy, the inquiry step length should be less than the size of the interrogation window.
文摘Using neutron activation analysis method we determined contents of rare-earth and radioactive elements (La, Ce, Nd, Sm, Eu, Tb, Yb, Lu, Cs, Rb, Sb, Sc, Sr, Ba, U, Th) in source water system of the Changjiang (Yangtze) River, which is mainly composed of the Tuotuo River, the Chumaer River, and the Buqu River. The contents of these elements in the unflltered water have a great variation and a close correlation with the water turbidity. The contents of these elements in filtered water only have a little variation and are lower than those in the unflltered water. The variations in contents of these elements in sediments are also very little. These elements in the unifiltered water are in geometric distribution, except Sc. Most of the elements in sediments are in arithmetic distribution, but Cs, Sb, Th, are in deviation distribution. The contents of most of these elements in the river source area correspond to the contents of fresh water of the earth. Most of these elements have a little variation in their