期刊文献+
共找到545篇文章
< 1 2 28 >
每页显示 20 50 100
Chinese expert consensus on the clinical application of drugcoated balloon(2^(nd) Edition)
1
作者 The Expert Writing Committee of the Chinese Expert Consensus on Clinical Applications of Drug-Coated Balloon(2^(nd)Edition) Jun-Bo GE Yun-Dai CHEN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第2期135-152,共18页
Percutaneous coronary interventions have progressed through the era of plain balloon dilation, bare-metal stent insertion to drug-eluting stent treatment, which has significantly reduced the acute occlusion and resten... Percutaneous coronary interventions have progressed through the era of plain balloon dilation, bare-metal stent insertion to drug-eluting stent treatment, which has significantly reduced the acute occlusion and restenosis rates of target vessels and improved patient prognosis, making drug-eluting stents the mainstream interventional treatment for coronary artery disease. In recent years, drug-coated balloons(DCBs) have become a new treatment strategy for coronary artery disease, and the drugs used in the coating and the coating technology have progressed in the past years. Without permanent implant, a DCB delivers antiproliferative drugs rapidly and uniformly into the vessel wall via the excipient during a single balloon dilation. Many evidence suggests that DCB angioplasty is an effective measure for dealing with in-stent restenosis and de novo lesions in small coronary vessels.As more clinical studies are published, new evidence is emerging for the use of DCB angioplasty in a wide range of coronary diseases, and the indications are expanding internationally. Based on the latest research from China and elsewhere, the Expert Writing Committee of the Chinese Expert Consensus on Clinical Applications of Drug-Coated Balloon has updated the previous DCB consensus after evidence-based discussions and meetings in terms of adequate preparation of in-stent restenosis lesions, expansion of the indications for coronary de novo lesions, and precise guidance of DCB treatment by intravascular imaging and functional evaluation. 展开更多
关键词 balloon DRUGS dealing
下载PDF
Significance of balloon aortic valvuloplasty as palliative procedure for symptom benefit in patients with severe aortic stenosis
2
作者 Jovica Banovic Vladimir Djuric +1 位作者 Vojislav Vuksinovic Sasa Loncar 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第3期374-378,共5页
Aortic stenosis(AS)stands out as the most prevalent individual valvular defect globally.The onset and progression of AS mirror an active process akin to atherosclerosis,and the traditional triad of symptoms includes c... Aortic stenosis(AS)stands out as the most prevalent individual valvular defect globally.The onset and progression of AS mirror an active process akin to atherosclerosis,and the traditional triad of symptoms includes chest pain,breathlessness,and loss of consciousness.Prognosis takes a significant downturn when symptoms manifest,with mortality reaching approximately 50%-85% within the subsequent 5 years after symptom onset. 展开更多
关键词 balloon STENOSIS MORTALITY
下载PDF
Study of Secondary Cosmic Rays and Astronomical X-Ray Sources using Small Stratospheric Balloons
3
作者 Rupnath Sikdar Sandip K.Chakrabarti Debashis Bhowmick 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2024年第6期94-109,共16页
The X-ray sources of the universe are extraterrestrial in nature which emit X-ray photons.The closest strong X-ray source is the Sun,which is followed by various compact sources such as neutron stars,black holes,the C... The X-ray sources of the universe are extraterrestrial in nature which emit X-ray photons.The closest strong X-ray source is the Sun,which is followed by various compact sources such as neutron stars,black holes,the Crab pulsar,etc.In this paper,we analyze the data received from several low-cost lightweight meteorological balloon-borne missions launched by the Indian Centre for Space Physics.Our main interest is to study the variation of the vertical intensity of secondary cosmic rays,the detection of strong X-ray sources,and their spectra in the energy band of^(1)0–80 keV during the complete flights.Due to the lack of an onboard pointing system,low exposure time,achieving a maximum altitude of only~42 km,and freely rotating the payload about its axis,we modeled the background radiation flux for the X-ray detector using physical assumptions.We also present the source detection method,observation of the pulsation of the Crab(^(3)3 Hz),and spectra of some sources such as the quiet Sun and the Crab pulsar. 展开更多
关键词 X-rays:stars balloonS instrumentation:detectors
下载PDF
Effi cacy of partial and complete resuscitative endovascular balloon occlusion of the aorta in the hemorrhagic shock model of liver injury
4
作者 Yi Shan Yang Zhao +3 位作者 Chengcheng Li Jianxin Gao Guogeng Song Tanshi Li 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第1期10-15,共6页
BACKGROUND:Resuscitative endovascular balloon occlusion of the aorta(REBOA)can temporarily control traumatic bleeding.However,its prolonged use potentially leads to ischemia-reperfusion injury(IRI).Partial REBOA(pREBO... BACKGROUND:Resuscitative endovascular balloon occlusion of the aorta(REBOA)can temporarily control traumatic bleeding.However,its prolonged use potentially leads to ischemia-reperfusion injury(IRI).Partial REBOA(pREBOA)can alleviate ischemic burden;however,its security and eff ectiveness prior to operative hemorrhage control remains unknown.Hence,we aimed to estimate the effi cacy of pREBOA in a swine model of liver injury using an experimental sliding-chamber ballistic gun.METHODS:Twenty Landrace pigs were randomized into control(no aortic occlusion)(n=5),intervention with complete REBOA(cREBOA)(n=5),continuous pREBOA(C-pREBOA)(n=5),and sequential pREBOA(S-pREBOA)(n=5)groups.In the cREBOA and C-pREBOA groups,the balloon was inflated for 60 min.The hemodynamic and laboratory values were compared at various observation time points.Tissue samples immediately after animal euthanasia from the myocardium,liver,kidneys,and duodenum were collected for histological assessment using hematoxylin and eosin staining.RESULTS:Compared with the control group,the survival rate of the REBOA groups was prominently improved(all P<0.05).The total volume of blood loss was markedly lower in the cREBOA group(493.14±127.31 mL)compared with other groups(P<0.01).The pH was significantly lower at 180 min in the cREBOA and S-pREBOA groups(P<0.05).At 120 min,the S-pREBOA group showed higher alanine aminotransferase(P<0.05)but lower blood urea nitrogen compared with the cREBOA group(P<0.05).CONCLUSION:In this trauma model with liver injury,a 60-minute pREBOA resulted in improved survival rate and was effective in maintaining reliable aortic pressure,despite persistent hemorrhage.Extended tolerance time for aortic occlusion in Zone I for non-compressible torso hemorrhage was feasible with both continuous partial and sequential partial measures,and the significant improvement in the severity of acidosis and distal organ injury was observed in the sequential pREBOA. 展开更多
关键词 Non-compressible torso hemorrhage Liver injury Ischemia-reperfusion injury Resuscitative endovascular balloon occlusion of the aorta
下载PDF
Balloon dilation of congenital perforated duodenal web in newborns: Evaluation of short and long-term results
5
作者 Kirill Marakhouski Elena Malyshka +5 位作者 Katsiaryna Nikalayeva Larysa Valiok Aleh Pataleta Kiryl Sanfirau Aliaksandr Svirsky Vasily Averin 《World Journal of Gastrointestinal Endoscopy》 2024年第6期343-349,共7页
BACKGROUND Incomplete congenital duodenal obstruction(ICDO)is caused by a congenitally perforated duodenal web(CPDW).Currently,only six cases of balloon dilatation of the PDW in newborns have been described.AIM To pre... BACKGROUND Incomplete congenital duodenal obstruction(ICDO)is caused by a congenitally perforated duodenal web(CPDW).Currently,only six cases of balloon dilatation of the PDW in newborns have been described.AIM To present our experience of balloon dilatation of a perforated duodenal memb-rane in newborns with ICDO.METHODS Five newborns who underwent balloon dilatation of the CPDW along a prein-stalled guidewire between 2021 and 2023 were included.Nineteen newborns diagnosed with ICDO who underwent laparotomy were included in the control group.RESULTS In all cases,good anatomical and clinical results were obtained.In three cases,a follow-up study was conducted after 1 year.The average time to start enteral feeding per os was significantly earlier in the study group(4.4 d)than in the laparotomic group(21.2 days;P<0.0001).The time spent by patients in the intensive care unit and hospital after balloon dilatation was also significantly shorter.We determined the selection criteria for possible and effective CPDW balloon dilatation in newborns as follows:(1)Presence of dynamic radiographic signs of the passage of a radiopaque substance beyond the zone of narrowing or radiographic signs of pneumatisation of the duodenum and small bowel distal to the web;(2)presence of endoscopic signs of CPDW;(3)successful cannulation with a guidewire performed parallel to the endoscope,with holes in the congenital duodenal web;and(4)successful positioning of the balloon performed along a freestanding guidewire on the web.CONCLUSION Strictly following selection criteria for newborns with ICDO caused by CPDW ensures that endoscopic balloon dilatation using a pre-installed guidewire is safe and effective and shows good 1-year follow-up results. 展开更多
关键词 NEWBORNS Congenital duodenal obstruction Perforated duodenal membrane ENDOSCOPY balloon dilation
下载PDF
The Efficacy and Safety of Drug-Coated Balloons in the Treatment of Acute Myocardial Infarction
6
作者 Mingliang Du Hui Hui 《World Journal of Cardiovascular Diseases》 CAS 2024年第1期1-9,共9页
The incidence of acute myocardial infarction (AMI) is increasing year by year, which seriously endangers human health around the world. The preferred treatment strategy for AMI patients is the use of drug-eluting sten... The incidence of acute myocardial infarction (AMI) is increasing year by year, which seriously endangers human health around the world. The preferred treatment strategy for AMI patients is the use of drug-eluting stents (DES), as there is ample evidence to suggest that stent implantation can reduce major adverse cardiovascular events (MACEs). With the application of drug-coated balloons (DCBs) and the enhancement of the concept of interventional without implantation, the question is whether DCBs can be safely and effectively used in patients with AMI? The purpose of this study was to investigate the safety and effectiveness of DCBs in the treatment of AMI. A retrospective review of clinical data was conducted on 55 AMI patients who underwent primary percutaneous coronary intervention (PCI) from January 2020 to December 2021. Of these patients, 25 were treated with DCBs and 30 were treated with DESs. Optical coherence tomography (OCT) was used to measure the minimum lumen diameter, lumen stenosis, and coronary artery dissection before and after surgery, and angina pectoris attacks and various MACEs were recorded at 1, 6, and 12 months after surgery. The results showed that there were no significant differences in clinical baseline data between the two groups. However, the minimum lumen diameter of the DCB group immediately after the operation was smaller than that of the DES group, and the stenosis degree of the lumen in the DCB group was higher than that in the DES group. The incidence of coronary artery dissection in the DCB group was significantly higher than that in the DES group, but the majority of them were type B. At 1, 6, and 12 months after treatment, there was no significant difference in the occurrence of MACEs between the two groups. In conclusion, DCBs is a safe and effective treatment for AMI. However, the incidence of coronary artery dissection in DCB patients is higher than that in DES patients, but the majority of them are type B. . 展开更多
关键词 Myocardial Infarction Drug-Coated balloon Drug-Eluting Stents
下载PDF
Pseudoaneurysm formation following transarterial embolization of traumatic carotid-cavernous fistula with detachable balloon:An institutional cohort long-term study
7
作者 Prasert Iampreechakul Korrapakc Wangtanaphat +5 位作者 Songpol Chuntaroj Yodkhwan Wattanasen Sunisa Hangsapruek Punjama Lertbutsayanukul Pimchanok Puthkhao Somkiet Siriwimonmas 《World Journal of Radiology》 2024年第4期94-108,共15页
BACKGROUND The goal of therapy for traumatic carotid-cavernous fistula(TCCF)is the elimination of fistula while maintaining patency of the parent artery.The treatment for TCCF has evolved from surgery to endovascular ... BACKGROUND The goal of therapy for traumatic carotid-cavernous fistula(TCCF)is the elimination of fistula while maintaining patency of the parent artery.The treatment for TCCF has evolved from surgery to endovascular management using detachable balloons,coils,liquid embolic agents,covered stents,or flow-diverter stent through arterial or venous approaches.Despite the withdrawal of detachable balloons from the market in the United States since 2004,transarterial embolization with detachable balloons has currently remained the best initial treatment for TCCF in several countries.However,the pseudoaneurysm formation following transarterial detachable balloon embolization has rarely been observed in long-term follow-up.AIM To determine the occurrence and long-term follow-up of pseudoaneurysm after transarterial detachable balloon for TCCF.METHODS Between January 2009 and December 2019,79 patients diagnosed with TCCF were treated using detachable latex balloons(GOLDBAL)of four sizes.Pseudoaneurysm sizes were stratified into five grades for analysis.Initial and follow-up assessments involved computed tomography angiography at 1 month,6 month,1 year,and longer intervals for significant cases.Clinical follow-ups occurred semi-annually for 2 years,then annually.Factors analyzed included sex,age,fistula size and location,and balloon size.RESULTS In our cohort of 79 patients treated for TCCF,pseudoaneurysms formed in 67.1%,with classifications ranging from grade 0 to grade 3;no grade 4 or giant pseudoaneurysms were observed.The majority of pseudoaneurysms did not progress in size,and some regressed spontaneously.Calcifications developed in most large pseudoaneurysms over 5-10 years.Parent artery occlusion occurred in 7.6%and recurrent fistulas in 16.5%.The primary risk factors for pseudoaneurysm formation were identified as the use of specific balloon sizes,with balloon SP and No.6 significantly associated with its occurrence(P=0.005 and P=0.002,respectively),whereas sex,age,fistula size,location,and the number of balloons used were not significant predictors.CONCLUSION Pseudoaneurysm formation following detachable balloon embolization for TCCF is common,primarily influenced by the size of the balloon used.Despite this,all patients with pseudoaneurysms remained asymptomatic during long-term follow-up. 展开更多
关键词 Pseudoaneurysm formation Traumatic carotid-cavernous fistula Direct carotid-cavernous fistula Transarterial embolization Detachable balloon Endovascular treatment Computed tomography angiography Long-term follow-up
下载PDF
Application of Clinical Care Pathway in Perioperative Patients with Autologous Arteriovenous Fistula Balloon Expansion
8
作者 Zhihua Deng Ru Xie +3 位作者 Bo Hu Shenling Hu Yingxue Zhong Yu Chen 《Open Journal of Urology》 2024年第7期415-421,共7页
[Objective] To explore the effect of clinical care pathways in perioperative patients with autologous arteriovenous fistula balloon expansion. [Method] 202 patients undergoing autologous arteriovenous fistula from Jul... [Objective] To explore the effect of clinical care pathways in perioperative patients with autologous arteriovenous fistula balloon expansion. [Method] 202 patients undergoing autologous arteriovenous fistula from July 2021 to June 2022 were randomly divided into a control group (101 cases) and an observation group (101 cases) to compare the incidence rates of postoperative complications, hospitalization days, hospitalization expenses, knowledge of self-management of arteriovenous fistula and nursing satisfaction. [Results] In the observation group, the incidence of arteriovenous fistula was higher than that of the control group, and the hospitalization days and hospitalization costs were lower than that of the control group. The difference between the two groups was statistically significant (P < 0.05). [Conclusion] The application of the clinical nursing path to intervene in patients with autologous arteriovenous fistula balloon dilation can reduce the incidence of postoperative complications, shorten the hospital length of time, reduce hospitalization costs and improve patient satisfaction, which is clinical promotion significance. 展开更多
关键词 Clinical Care Path Autologous Arteriovenous Fistula balloon Expansion Perioperative Period
下载PDF
Feasibility and clinical benefits of the double-ProGlide technique for hemostasis after cryoballoon atrial fibrillation ablation with uninterrupted oral anticoagulants 被引量:2
9
作者 Jia-Yin SUN Chang-Bo XUAN +7 位作者 Hai-Liang YU Hai-Yang WANG Hong-Ya HAN Zhi-Ming ZHOU De-An JIA Dong-Mei SHI Yu-Jie ZHOU Shi-Wei YANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2023年第4期268-275,共8页
OBJECTIVE To access the efficacy and safety of the double-ProGlide technique for the femoral vein access-site closure in cryoballoon ablation with uninterrupted oral anticoagulants(OAC),and its impact on the electroph... OBJECTIVE To access the efficacy and safety of the double-ProGlide technique for the femoral vein access-site closure in cryoballoon ablation with uninterrupted oral anticoagulants(OAC),and its impact on the electrophysiology laboratory time as well as hospital stay after the procedure in this observational study.METHODS Patients with atrial fibrillation undergoing cryoballoon ablation with uninterrupted OAC at Department of Cardiology,Beijing Anzhen Hospital,Capital Medical University,Beijing,China from May 2019 to May 2021 were enrolled in this study.From October 2020,double-ProGlide technique was consistently used for hemostasis(ProGlide group),and before that conventional manual compression was utilized(manual compression group).The occurrence of vascular and groin complications was accessed during the hospital stay and until the three-month follow-up.RESULTS A total of 140 participants(69.30%of male,mean age:59.21±10.29 years)were evaluated,70 participants being in each group.Immediate hemostasis was achieved in all the patients with ProGlide closure.No major vascular complications were found in the ProGlide group while two major vascular complications were occurred in the manual compression group.The incidence of any groin complication was obviously higher in subjects with manual compression than patients with ProGlide devices(15.71%vs.2.86%,P=0.009).In addition,compared with the manual compression group,the ProGlide group was associated with significantly shorter total time in the electrophysiology laboratory[112.0(93.3–128.8)min vs.123.5(107.3–158.3)min,P=0.006],time from sheath removal until venous site hemostasis[3.8(3.4–4.2)min vs.8.0(7.6–8.5)min,P<0.001],bed rest time[8.0(7.6–8.0)h vs.14.1(12.0–17.6)h,P<0.001]and hospital stay after the procedure[13.8(12.5–17.8)h vs.38.0(21.5–41.0)h,P<0.001].CONCLUSIONS Utilization of the double-ProGlide technique for hemostasis after cryoballoon ablation with uninterrupted OAC is feasible and safe,which has the clinical benefit in reducing the total electrophysiology laboratory time and the hospital stay length after the procedure. 展开更多
关键词 balloon interrupted CLOSURE
下载PDF
Resuscitative endovascular balloon occlusion of the aorta in the treatment of severe hemorrhagic shock caused by upper gastrointestinal bleeding 被引量:1
10
作者 Yu-lin Li Jun-yang Wang +3 位作者 Wen Han Tao Sun Kang Lyu Shan-xiang Xu 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2023年第3期247-249,共3页
Hemorrhagic shock is a life-threatening disease often encountered in emergency departments(EDs).Hemorrhagic shock caused by extensive bleeding from multiple sites is often associated with high mortality and morbidity.... Hemorrhagic shock is a life-threatening disease often encountered in emergency departments(EDs).Hemorrhagic shock caused by extensive bleeding from multiple sites is often associated with high mortality and morbidity.In recent years,resuscitative endovascular balloon occlusion of the aorta(REBOA)has been widely used in traumatic hemorrhagic shock and is considered to be an effective resuscitation measure.[1]Some studies reported that REBOA was also effective for non-traumatic hemorrhage.[2,3]In this study,we report a case of hemorrhagic shock caused by acute upper gastrointestinal bleeding that was successfully treated and received REBOA to obtain a transition time.This report may provide feasible options for emergency physicians,gastroenterologists,or surgeons to more actively treat refractory gastrointestinal bleeding. 展开更多
关键词 balloon HEMORRHAGIC GASTROINTESTINAL
下载PDF
Balloon displacement during caesarean section with pernicious placenta previa: A case report 被引量:1
11
作者 Deng-Feng Gu Chao Deng 《World Journal of Clinical Cases》 SCIE 2023年第36期8574-8580,共7页
BACKGROUND For the past few years,preventive interventional therapy has been widely used domestically and overseas,bringing great benefits to pregnant women at high-risk for complications,such as pernicious placenta p... BACKGROUND For the past few years,preventive interventional therapy has been widely used domestically and overseas,bringing great benefits to pregnant women at high-risk for complications,such as pernicious placenta previa(PPP)and placenta accreta.Nevertheless,there are still few reports on surgical complications related to interventional therapy,and its safety should be a concern.CASE SUMMARY We report a 36-year-old pregnant woman with PPP who underwent balloon implantation in the lower segment of the abdominal aorta before caesarean section.However,the balloon shifted during the operation,which damaged the arterial vessels after filling,resulting in severe postpartum haemorrhage in the patient.Fortunately,after emergency interventional stent implantation,the pa-tient was successfully relieved of the massive haemorrhage crisis.CONCLUSION It seems that massive postoperative bleeding has been largely avoided in preventive interventional therapy in high-risk pregnant women with placenta-related diseases,but surgical complications related to intervention therapy can also cause adverse consequences.It is equally important for clinical doctors to learn how to promptly identify and effectively treat these rare complications. 展开更多
关键词 Pernicious placenta previa Caesarean section Abdominal aortic balloon Case report
下载PDF
Drug-coated balloons for the treatment of ostial left anterior descending or ostial left circumflex artery lesions:a patientlevel propensity score-matched analysis
12
作者 Liang PAN Wen-Jie LU +9 位作者 Zhan-Ying HAN San-Cong PAN Xi WANG Ying-Guang SHAN Meng PENG Xiao-Fei QIN Guo-Ju SUN Pei-Sheng ZHANG Jian-Zeng DONG Chun-Guang QIU 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2023年第10期716-727,I0001-I0005,共17页
BACKGROUND Controversy exists as to the optimal treatment approach for ostial left anterior descending(LAD)or ostial left circumflex artery(LCx)lesions.Drug-coated balloons(DCB)may overcome some of the limitations of ... BACKGROUND Controversy exists as to the optimal treatment approach for ostial left anterior descending(LAD)or ostial left circumflex artery(LCx)lesions.Drug-coated balloons(DCB)may overcome some of the limitations of drug-eluting stents(DES).Therefore,we investigated the security and feasibility of the DCB policy in patients with ostial LAD or ostial LCx lesions,and compared it with the conventional DES-only strategy.METHODS We retrospectively enrolled patients with de novo ostial lesions in the LAD or LCx who underwent interventional treatment.They were categorized into two groups based on their treatment approach:the DCB group and the DES group.The treatment strategies in the DCB group involved the use of either DCB-only or hybrid strategies,whereas the DES group utilized crossover or precise stenting techniques.Two-year target lesion revascularization was the primary endpoint,while the rates of major adverse cardiovascular events,cardiac death,target vessel myocardial infarction,and vessel thrombosis were the secondary endpoints.Using propensity score matching,we assembled a cohort with comparable baseline characteristics.To ensure result analysis reliability,we conducted sensitivity analyses,including interaction,and stratified analyses.RESULTS Among the 397 eligible patients,6.25%of patients who were planned to undergo DCB underwent DES.A total of 108 patients in each group had comparable propensity scores and were included in the analysis.Two-year target lesion revascularization occurred in 5 patients(4.90%)and 16 patients(16.33%)in the DCB group and the DES group,respectively(odds ratio=0.264,95%CI:0.093–0.752,P=0.008).Compared with the DES group,the DCB group demonstrated a lower major adverse cardiovascular events rate(7.84%vs.19.39%,P=0.017).However,differences with regard to cardiac death,non-periprocedural target vessel myocardial infarction,and definite or probable vessel thrombosis between the groups were non-significant.CONCLUSIONS The utilization of the DCB approach signifies an innovative and discretionary strategy for managing isolated ostial lesions in the LAD or LCx.Nevertheless,a future randomized trial investigating the feasibility and safety of DCB compared to the DES-only strategy specifically for de novo ostial lesions in the LAD or LCx is highly warranted. 展开更多
关键词 LESIONS balloon TREATMENT
下载PDF
Safety and efficacy of balloon angioplasty compared to stent-basedstrategies with pulmonary vein stenosis:A systematic review and meta-analysis
13
作者 Pradyumna Agasthi Srilekha Sridhara +14 位作者 Pattara Rattanawong Nithin Venepally Chieh-Ju Chao Hasan Ashraf Sai Harika Pujari Mohamed Allam Diana Almader-Douglas Yamini Alla Amit Kumar Farouk Mookadam Douglas L Packer David R Holmes Jr Donald J Hagler Floyd David Fortuin Reza Arsanjani 《World Journal of Cardiology》 2023年第2期64-75,共12页
BACKGROUND Pulmonary vein stenosis(PVS)is an uncommon but known cause of morbidity and mortality in adults and children and can be managed with percutaneous revascularization strategies of pulmonary vein balloon angio... BACKGROUND Pulmonary vein stenosis(PVS)is an uncommon but known cause of morbidity and mortality in adults and children and can be managed with percutaneous revascularization strategies of pulmonary vein balloon angioplasty(PBA)or pulmonary vein stent implantation(PSI).AIM To study the safety and efficacy outcomes of PBA vs PSI in all patient categories with PVS.METHODS We performed a literature search of all studies comparing outcomes of patients evaluated by PBA vs PSI for PVS.We selected all published studies comparing PBA vs PSI for PVS with reported outcomes of restenosis and procedure-related complications in all patient categories.In adults,PVS following atrial fibrillation ablation and in children PVS related to congenital etiology or post-procedural PVS following total or partial anomalous pulmonary venous return repair were included.The patient-centered outcomes were risk of restenosis requiring re-intervention and procedural-related complications.The metaanalysis was performed by computing odds ratios(ORs)using the random effects model based on underlying statistical heterogeneity.RESULTS Eight observational studies treating 768 severe PVS in 487 patients met our inclusion criteria.The age range of patients was 6 months to 70 years and 67%were males.The primary outcome of the re-stenosis requiring re-intervention occurred in 196 of 325 veins in the PBA group and 111 of 443 veins in the PSI group.Compared to PSI,PBA was associated with a significantly increased risk of re-stenosis(OR 2.91,95%CI:1.15-7.37,P=0.025,I2=79.2%).Secondary outcomes of the procedurerelated complications occurred in 7 of 122 patients in the PBA group and 6 of 69 in the PSI group.There were no statistically significant differences in the safety outcomes between the two groups(OR:0.94,95%CI:0.23-3.76,P=0.929,I^(2)=0.0%).CONCLUSION Across all patient categories with PVS,PSI is associated with reduced risk of re-intervention and is as safe as PBA and should be considered first-line therapy for PVS. 展开更多
关键词 Pulmonary veins Pulmonary vein stenosis CONSTRICTION balloon angioplasty STENTS Drugeluting stents
下载PDF
Balloon-occluded retrograde transvenous obliteration for treatment of congenital intrahepatic portosystemic venous shunt:A case report
14
作者 Shenggan Lin Zhenyu Xu +4 位作者 Zhuoyang Fan Wei Zhang Guowei Yang Sheng Qian Rong Liu 《Journal of Interventional Medicine》 2023年第1期49-51,共3页
Congenital intrahepatic portosystemic venous shunt(CPSVS), a rare vascular malformation, has been described in both children and adults and can lead to severe neurophysiological complications. However, a standard ther... Congenital intrahepatic portosystemic venous shunt(CPSVS), a rare vascular malformation, has been described in both children and adults and can lead to severe neurophysiological complications. However, a standard therapeutic protocol for CPSVS has not been elucidated. With the advantage of minimally invasive techniques,transcatheter embolization has been used to treat CPSVS. The condition is challenging to manage, especially in patients with large or multiple shunts, through which rapid blood flow can cause ectopic embolism. Here, we describe a case of CPSVS with a large shunt that was successfully treated with balloon-occluded retrograde transvenous obliteration with interlocking detachable coils. 展开更多
关键词 Hepatic vein Portal vein Vascular malformations Endovascular procedures balloon occlusion
下载PDF
“Guidezilla”extension catheter combined with balloon technique for treating pulmonary artery stenosis caused by Takayasu arteritis
15
作者 Yifan Wu Jinzhi Wang +5 位作者 Zhihui Fu Min Liu Wanmu Xie Xincao Tao Qiang Huang Zhenguo Zhai 《Journal of Interventional Medicine》 2023年第4期198-201,共4页
Takayasu arteritis(TA)is a rare systemic vasculitis of the aorta and its primary branches,which usually occurs in young women.Due to its insidious onset and lack of specific symptoms,this disease can be easily misdiag... Takayasu arteritis(TA)is a rare systemic vasculitis of the aorta and its primary branches,which usually occurs in young women.Due to its insidious onset and lack of specific symptoms,this disease can be easily misdiagnosed or missed.Approximately 50%of the patients having TA with pulmonary artery involvement develop pulmonary hypertension(PH).The 3-year survival rate among patients with TA-related PH is lower than that among patients with TA alone.Early balloon pulmonary angioplasty(BPA)can improve the clinical symptoms and survival of patients with stable TA.To the best of our knowledge,this is the first case reported in the English literature in which a“Guidezilla”catheter was used during BPA to treat stenosis and occlusion of the pulmonary artery caused by Takayasu arteritis(TA). 展开更多
关键词 Takayasu arteritis Pulmonary hypertension balloon pulmonary angioplasty Guidezilla catheter
下载PDF
A novel cerebrovascular drug-coated balloon catheter for treating symptomatic intracranial atherosclerotic stenosis lesions:Study protocol for a prospective,multicenter,single-arm,target-value clinical trial
16
作者 Qianhao Ding Wenbo Liu +10 位作者 Jingge Zhao Dehua Guo Yao Tang Tengfei Zhou Yanyan He Ferdinand K.Hui Yonghong Ding Liangfu Zhu Zilang Wang Yingkun He Tianxiao Li 《Journal of Interventional Medicine》 2023年第4期179-185,共7页
Background:Previous single-center studies have demonstrated that drug-coated balloons(DCBs)may reduce restenosis rates,which is an important factor affecting the prognosis for intracranial interventional therapy.Howev... Background:Previous single-center studies have demonstrated that drug-coated balloons(DCBs)may reduce restenosis rates,which is an important factor affecting the prognosis for intracranial interventional therapy.However,currently available cardiac DCBs are not always suitable for the treatment of intracranial atherosclerotic stenosis(ICAS).This study aimed to evaluate the safety and efficacy of a novel DCB catheter designed for patients with severely symptomatic ICAS.Methods:This prospective,multicenter,single-arm,target-value clinical trial was conducted in 9 Chinese stroke centers to evaluate the safety and efficacy of a novel DCB catheter for treating symptomatic severe ICAS.Primary metrics and other indicators were collected and analyzed using SAS version 9.4(SAS Institute,Cary,NC,USA).Results:A total of 155 patients were enrolled in this study.The preliminary collection of follow-up data has been completed,while data quality control is ongoing.Conclusion:Results of this study demonstrated the patency rate,safety,and effectiveness of a novel on-label paclitaxel DCB designed for the treatment of ICAS.Ethics and dissemination:This study,involving human participants,was reviewed and approved by the Ethics Committee of Drugs(Devices)Clinical Experiment at Henan Provincial People’s Hospital(reference number:2020-145-03)and other research centers participating in the clinical trial.The results of this study will be presented at international conferences and sent to peer-reviewed journals for publication.Standard protocol items:The Recommendations for Interventional Trials checklist was used when drafting the study protocol.Trial registration number:Registered with the Chinese Clinical Trial Registry on June 11,2021(Chi CTR2100047223). 展开更多
关键词 Intracranial arterial stenosis Drug-coated balloon Ischemic stroke Transient ischemic attack Endovascular therapy
下载PDF
Drug-coated balloons for treating de novo lesions in large coronary vessels:A case report
17
作者 Zhi-Qiang Zhang Yi-Ran Qin +4 位作者 Man Yin Xue-Heng Chen Lei Chen Wen-Yan Liang Xi-Qing Wei 《World Journal of Clinical Cases》 SCIE 2023年第20期4920-4925,共6页
BACKGROUND Percutaneous transluminal coronary angioplasty,while an effective intervention,can frequently lead to acute occlusion with severe consequences.Although clinical trials have demonstrated the efficacy of drug... BACKGROUND Percutaneous transluminal coronary angioplasty,while an effective intervention,can frequently lead to acute occlusion with severe consequences.Although clinical trials have demonstrated the efficacy of drug-coated balloons(DCB)in treating acute coronary artery occlusion and in preventing restenosis,there has been limited exploration on the use of DCB in treating de novo lesions in large vessels.Currently,DCB are only recommended for patients with small vessel lesions and in-stent restenosis lesions,those at high risk of bleeding,and other special groups of patients.CASE SUMMARY This report presents a case of successful drug-coated balloon treatment of de novo lesions in large coronary vessels.Postoperatively,the patient demonstrated favorable recovery,with subsequent examination results revealing no significant differences from the previous examination.CONCLUSION The successful treatment of the patient in our case highlights the potential of DCB in the treatment of de novo lesions in large coronary vessels. 展开更多
关键词 Drug-coated balloons De novo lesions Large coronary vessels Coronary artery disease Percutaneous coronary intervention Case report
下载PDF
Outcomes of repeat transcatheter aortic valve replacement with balloon-expandable valves: a registry study
18
作者 Raj R Makkar 《四川生理科学杂志》 2023年第9期1578-1578,共1页
Background:With increasing numbers of patients undergoing transcatheter aortic valve replacement(TAVR),data on management of failed TAVR,including repeat TAVR procedure,are needed.The aim of this study was to assess t... Background:With increasing numbers of patients undergoing transcatheter aortic valve replacement(TAVR),data on management of failed TAVR,including repeat TAVR procedure,are needed.The aim of this study was to assess the safety and efficacy of redo-TAVR in a national registry.Methods:This study included all consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from Nov 9,2011,to Dec 30,2022 who underwent TAVR with balloon-expandable valves in failed transcatheter heart valves(redo-TAVR)or native aortic valves(native-TAVR). 展开更多
关键词 balloon TRANSCATHETER AORTIC
下载PDF
经鼓室口咽鼓管球囊扩张术的疗效及咽鼓管功能的影响
19
作者 谢先荣 付亚峰 刘伟清 《中国耳鼻咽喉头颈外科》 CSCD 2024年第2期122-124,共3页
目的探讨经鼓室口咽鼓管球囊扩张(balloon dilatation Eustachian tuboplasty,BET)联合腺样体消融术对慢性分泌性中耳炎(chronic secretory otitis media,CSOM)患儿的疗效及咽鼓管功能的影响。方法选取2020年6月~2022年12月间在中山市... 目的探讨经鼓室口咽鼓管球囊扩张(balloon dilatation Eustachian tuboplasty,BET)联合腺样体消融术对慢性分泌性中耳炎(chronic secretory otitis media,CSOM)患儿的疗效及咽鼓管功能的影响。方法选取2020年6月~2022年12月间在中山市小榄人民医院就诊的CSOM患儿82例作为研究对象,采用随机数字表法分为对照组和观察组,每组41例。对照组接受腺样体消融术+鼓膜切开置管术治疗,观察组接受腺样体消融术+鼓膜切开置管术+BET术。比较两组手术相关指标及住院时间、临床症状、咽鼓管功能、临床疗效及随访6个月并发症及复发情况。结果两组术中出血量比较,差异无统计学意义(P>0.05),与对照组相比,观察组手术时间更长,住院时间更短(P<0.05)。与对照组相比,观察组中耳积液消失时间、耳鸣消失时间、鼓膜愈合时间、听力恢复时间均更短(P<0.05)。与治疗前相比,治疗后两组咽鼓管评分(Eustachian tube score,ETS)升高、咽鼓管功能障碍评分量表(Eustachian tube dysfunction questionnaire-7,ETDQ-7)评分降低(P<0.05),观察组ETS评分高于对照组,ETDQ-7评分则低于对照组(P<0.05)。观察组临床总有效率高于对照组,差异具有统计学意义(P<0.05)。两组并发症发生率比较,差异无统计学意义(14.63%vs.9.76%,P>0.05),与对照组相比,观察组复发率更低,差异具有统计学意义(21.95%vs.2.44%,P<0.05)。结论经鼓室口BET联合腺样体消融术有助于提高CSOM患儿的临床疗效,改善咽鼓管功能,促进术后恢复,减少复发率,且并发症发生率低。 展开更多
关键词 伴渗出液中耳炎(Otitis Media with Effusion) 咽鼓管(Eustachian Tube) 扩张术(Dilatation) 腺样体切除术(Adenoidectomy) 咽鼓管球囊扩张术(balloon dilatation Eustachian tuboplasty) 咽鼓管鼓室口(tympanic opening of Eustachian tube)
下载PDF
Indian monsoon drove the dispersal of the thoracica group of Scytodes spitting spiders
20
作者 Yu-Fa Luo Shu-Qiang Li 《Zoological Research》 SCIE CSCD 2024年第1期152-159,共8页
We examined the global biogeography of the Scytodes thoracica group of spitting spiders based on 23 years of sampling at the species level(61 species in the thoracica group and 84 species of Scytodes)using DNA data fr... We examined the global biogeography of the Scytodes thoracica group of spitting spiders based on 23 years of sampling at the species level(61 species in the thoracica group and 84 species of Scytodes)using DNA data from six loci.Our results indicated that the thoracica group initially dispersed from Southeast Asia to East Africa between 46.5 and 33.0 million years ago,and dispersal events intensified between Southeast/South Asia and East/South Africa from the early to late Miocene.The timing of these events indicates that Asian-African faunal exchange of the thoracica group was driven by the Indian monsoon,and the pattern of dispersal suggests that colonialization took root when the Indian monsoon shifted from a North-South direction to an East-West direction from the middle Eocene. 展开更多
关键词 Geological event Climate change ballooning organism Faunal exchange Species distribution
下载PDF
上一页 1 2 28 下一页 到第
使用帮助 返回顶部