For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,th...For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,this study aims to analyze the shear force of debris flows within the bend channel.We established the relationship between the shear force and bend curvature through laboratory experiments.Under the long-term erosion by debris flows,the curvature radius of bends gradually increases,however,when this increasing trend reaches an equilibrium state with the intensity of debris flow discharge,there will be no significant change in curvature radius.In general,the activity pattern and discharges of debris flows would remain relatively stable.Hence,we can infer the magnitude of debris flow discharges from the terrain parameters of the bend channel.展开更多
The environmental contamination caused by antibiotics is increasingly conspicuous due to their widespread manufacture and misuse. Plasma has been employed in recent years for the remediation of antibiotic pollution in...The environmental contamination caused by antibiotics is increasingly conspicuous due to their widespread manufacture and misuse. Plasma has been employed in recent years for the remediation of antibiotic pollution in the environment. In this work, a falling-film dielectric barrier discharge was used to degrade the antibiotic tetracycline(TC) in water. The reactor combined the gas-liquid discharge and active gas bubbling to improve the TC degradation performance. The discharge characteristics, chemical species’ concentration, and degradation rates at different parameters were systematically studied. Under the optimized conditions(working gas was pure oxygen, liquid flow rate was 100 mL/min, gas flow rate was 1 L/min,voltage was 20 kV, single treatment), TC was removed beyond 70% in a single flow treatment with an energy efficiency of 145 mg/(kW·h). The reactor design facilitated gas and liquid flow in the plasma area to produce more ozone in bubbles after a single flow under pure oxygen conditions, affording fast TC degradation. Furthermore, long-term stationary experiment indicated that long-lived active species can sustain the degradation of TC. Compared with other plasma treatment systems, this work offers a fast and efficient degradation method, showing significant potential in practical industrial applications.展开更多
Peak discharge plays an important role in triggering channelized debris flows.The rainfall regimes and rainfall characteristics have been demonstrated to have important influences on peak discharge.In order to explore...Peak discharge plays an important role in triggering channelized debris flows.The rainfall regimes and rainfall characteristics have been demonstrated to have important influences on peak discharge.In order to explore the relationship between rainfall regimes and peak discharge,a measuring system was placed at the outlet of a small,debris flow-prone catchment.The facility consisted of an approximately rectangular stilling basin,ending with a sharp-crested weir.Six runoff events were recorded which provided a unique opportunity for characterizing the hydrological response of the debris flow-prone catchment.Then,a rainfall–runoff model was tested against the flow discharge measurements to have a deep understanding of hydrological response.Based on the calibrated rainfall-runoff model,twelve different artificially set rainfall patterns were regarded as the input parameters to investigate the effect of rainfall regimes on peak discharge.The results show that the rainfall patterns have a significant effect on peak discharge.The rainfall regimes which have higher peak rainfall intensity and peak rainfall point occur at the later part of rainfall process are easy to generate larger peak discharge in the condition of the same cumulative rainfall and duration.Then,in order to explore the relationship between rainfall characteristics and peak discharge under different cumulative precipitation and different duration,167 measured rainfall events were also collected.On the basis of rainfall depth,rainfall duration,and maximum hourly intensity,all the rainfall events were classified into four categories by using K-mean clustering.Rainfall regime 1 was composed of rainfall events with a moderate mean P(precipitation),a moderate D(duration),and a moderate I60(maximum hourly intensity).Rainfall regime 2 was the group of rainfall events with a high mean P,long D.Rainfall regime 3,however,had a low P and a long D.The characteristic of Rainfall regime 4 was high I60 and short duration with large P.The results show that the rainfall regime 2 and 4 are easier to generate peak discharge as the rainfall intensity plays an important role in generating peak discharge.The results in this study have implications for improving peak discharge prediction accuracy in debris flow gully.展开更多
The surface dielectric barrier discharge (SDBD) plasma actuator has shown great promise as an aerodynamic flow control device. In this paper, the encapsulated electrode width of a SDBD actuator is changed to study t...The surface dielectric barrier discharge (SDBD) plasma actuator has shown great promise as an aerodynamic flow control device. In this paper, the encapsulated electrode width of a SDBD actuator is changed to study the airflow acceleration behavior. The effects of encapsulated electrode width on the actuator performance are experimentally investigated by measuring the dielectric layer surface potential, time-averaged ionic wind velocity and thrust force. Experimental results show that the airflow velocity and thrust force increase with the encapsulated electrode width. The results can be attributed to the distinct plasma distribution at different encapsulated electrode widths.展开更多
Dielectric barrier discharge (DBD) plasma is one of most promising flow control method for its several advantages. The present work investigates the control authority of nanosecond pulse DBD plasma actuators on a fl...Dielectric barrier discharge (DBD) plasma is one of most promising flow control method for its several advantages. The present work investigates the control authority of nanosecond pulse DBD plasma actuators on a flying wing model's aerodynamic characteristics. The aerodynamic forces and moments are studied by means of experiment and numerical simulation. The numerical simulation results are in good agreement with experiment results. Both results indicate that the NS-DBD plasma actuators have negligible effect on aerodynamic forces and moment at the angles of attack smaller than 16-. However, significant changes can be achieved with actuation when the model's angle of attack is larger than 16° where the flow separation occurs. The spatial flow field structure results from numerical simulation suggest that the volumetric heat produced by NS-DBD plasma actuator changes the local temperature and density and induces several vortex structures, which strengthen the mixing of the shear layer with the main flow and delay separation or even reattach the separated flow.展开更多
The operating performance of positive discharge blower is markedly influenced by the pulsation of the discharge flow, but difficult to be measured with experimental methods. The internal and discharge flow of positive...The operating performance of positive discharge blower is markedly influenced by the pulsation of the discharge flow, but difficult to be measured with experimental methods. The internal and discharge flow of positive discharge blower with involute type three-lobe are numerically investigated, both in air cooling and countercurrent cooling conditions by means of computational fluid dynamics (CFD). The unsteady compressible flow equations are solved using RNG x-ε turbulent model. The finite difference method and the second order upwind difference scheme are applied into discrete equations. In the numerical simulation, the dynamic mesh techniques are used to approach the rotating displacement of cell cubage and the alterability of inlet, outlet flow area. The non-uniform mesh is applied to the rotor-stator coupled area. The reliability of the numerical method is verified by simulating the inner flow and comparing with the semi-empirical theory. The flow flux curves and the distributing of velocity vector showed obvious vortex motion in all the discharge process, both in air cooling and countercurrent cooling conditions. These vortexes with different positions, intension and numbers at different rotating angles have remarkable influences on the discharge flux. For air cooling, the vortex produced a second pulsation with big-amplitude in a cycle, and led to the early appearance of maximum of backflow. For countercurrent cooling, the frequency of pulsation increased due to the pre-inflow, but the backflow at the outlet is prevented, also the pulsation strength has greatly decreased.展开更多
This study investigate the relationships between geomorphometric properties and the minimum low flow discharge of undisturbed drainage basins in the Taman Bukit Cahaya Seri Alam Forest Reserve, Peninsular Malaysia. Th...This study investigate the relationships between geomorphometric properties and the minimum low flow discharge of undisturbed drainage basins in the Taman Bukit Cahaya Seri Alam Forest Reserve, Peninsular Malaysia. The drainage basins selected were third-order basins so as to facilitate a common base for sampling and performing an unbiased statistical analyses. Three levels of relationships were observed in the study. Significant relationships existed between the geomorphometric properties as shown by the correlation network analysis; secondly, individual geomorphometric properties were observed to influence minimum flow discharge; and finally, the multiple regression model set up showed that minimum flow discharge(Q min) was dependent of basin area(AU), stream length(LS), maximum relief(Hmax), average relief(HAV) and stream frequency(SF). These findings further enforced other studies of this nature that drainage basins were dynamic and functional entities whose operations were governed by complex interrelationships occurring within the basins. Changes to any of the geomorphometric properties would influence their role as basin regulators thus influencing a change in basin response. In the case of the basin's minimum low flow, a change in any of the properties considered in the regression model influenced the “time to peak' of flow. A shorter time period would mean higher discharge, which is generally considered the prerequisite to flooding. This research also conclude that the role of geomorphometric properties to control the water supply within the stream through out the year even though during the drought and less precipitations months. Drainage basins are sensitive entities and any deteriorations involve will generate reciprocals and response to the water supply as well as the habitat within the areas.展开更多
Flow discharge from the river basin into the sea has severe impacts on the immediate vicinity of river channels, estuaries, and coastal areas. This paper analyzes the features and temporal trends of flow discharge at ...Flow discharge from the river basin into the sea has severe impacts on the immediate vicinity of river channels, estuaries, and coastal areas. This paper analyzes the features and temporal trends of flow discharge at Pearl River's three main gauge stations: the Wuzhou, Shijiao, and Boluo gauge stations on the West River, North River, and East River, respectively. The results show no significant trend in annual mean discharge into the sea at the three gauge stations. Changes of monthly mean discharge at the Boluo Gauge Station are evident, and a majority of monthly discharge in the dry season displays significant increasing trends. Furthermore, changes of the extreme discharge are quite evident, with a significant decreasing trend in the annual maximum discharge and a significant increasing trend in the minimum one. The significantly decreasing ratio of the flood discharge to annual discharge at the Boluo Gauge Station indicates that the flow discharge from the East River has increased in the dry season and decreased in the flood season since the construction of dams and reservoirs. At the other two gauge stations, the Wuzhou and Shijiao gauge stations, the seasonal discharge generally does not change perceptibly. Human impacts, especially those pertaining to reservoir and dam construction, appear to be responsible for the seasonal variation of flow discharge. The results indicate that the construction and operation of dams and reservoirs in the East River have a greater influence on flow discharge, which can well explain why the seasonal variation of flow discharge from the East River is more evident.展开更多
The three-electrode sliding dielectric barrier discharge(TES-DBD) plasma actuator significantly enhances the ionization rate and momentum exchange between charged particles and neutral particles by incorporating a par...The three-electrode sliding dielectric barrier discharge(TES-DBD) plasma actuator significantly enhances the ionization rate and momentum exchange between charged particles and neutral particles by incorporating a parallel DC electrode into the standard DBD design. This design improves the body force and induced jet velocity while allowing flexible control of the induced jet angle, overcoming the limitations of discharge extension and uncontrollable direction in traditional DBD plasma actuators. An integrated plasma power supply has been designed specifically for TES-DBD plasma actuators, streamlining the power supply management. The methodology involves designing the circuit topology for the TES-DBD power supply, followed by simulating and validating its operating principles using Multisim software. The operational performance of the power supply is evaluated through a comprehensive analysis of its electrical,thermal, and aerodynamic properties specific to TES-DBD plasma actuation.展开更多
Experimental investigation was conducted to study the flow regimes and discharge characteristics of plasma electrohydrodynamic atomization (EHDA) for decane (CloH22) under pulsed applied negative voltage. The expe...Experimental investigation was conducted to study the flow regimes and discharge characteristics of plasma electrohydrodynamic atomization (EHDA) for decane (CloH22) under pulsed applied negative voltage. The experimental parameters were set as the flow rate of decane from 0 mL/min to 10 mL/min and the DC charging voltage from DC 0 V to 12 V with a pulse repetition rates of 200 Hz. The flow regime of decane was observed and the volume-to-electrical charge ratio was measured. Unlike a conventional EHDA system, the results show that a corona discharge was initiated at the edge of the hollow electrode at a specific corona on-set voltage of -17 kV or -20 kV in the case with or without decane flow, respectively. This phenomenon was defined as plasma EHDA.展开更多
Thermal and induced flow velocity characteristics of radio frequency(RF) surface dielectric barrier discharge(SDBD)plasma actuation are experimentally investigated in this paper. The spatial and temporal distribut...Thermal and induced flow velocity characteristics of radio frequency(RF) surface dielectric barrier discharge(SDBD)plasma actuation are experimentally investigated in this paper. The spatial and temporal distributions of the dielectric surface temperature are measured with the infrared thermography at atmospheric pressure. In the spanwise direction, the highest dielectric surface temperature is acquired at the center of the high voltage electrode, while it reduces gradually along the chordwise direction. The maximum temperature of the dielectric surface raises rapidly once discharge begins.After several seconds(typically 100 s), the temperature reaches equilibrium among the actuator's surface, plasma, and surrounding air. The maximum dielectric surface temperature is higher than that powered by an AC power supply in dozens of k Hz. Influences of the duty cycle and the input frequency on the thermal characteristics are analyzed. When the duty cycle increases, the maximum dielectric surface temperature increases linearly. However, the maximum dielectric surface temperature increases nonlinearly when the input frequency varies from 0.47 MHz to 1.61 MHz. The induced flow velocity of the RF SDBD actuator is 0.25 m/s.展开更多
Influence of plasma actuators as a flow separation control device was investigated experimentally. Hump model was used to demonstrate the effect of plasma actuators on external flow separation, while for internal flow...Influence of plasma actuators as a flow separation control device was investigated experimentally. Hump model was used to demonstrate the effect of plasma actuators on external flow separation, while for internal flow separation a set of compressor cascade was adopted. In order to investigate the modification of the flow structure by the plasma actuator, the flow field was examined non-intrusively by particle image velocimetry measurements in the hump model experiment and by a hot film probe in the compressor cascade experiment. The results showed that the plasma actuator could be effective in controlling the flow separation both over the hump and in the compressor cascade when the incoming velocity was low. As the incoming velocity increased, the plasma actuator was less effective. It is urgent to enhance the intensity of the plasma actuator for its better application. Methods to increase the intensity of plasma actuator were also studied.展开更多
It is known that gas flow rate is a key factor in controlling industrial plasma processing. In this paper, a 2D PIC/MCC model is developed for an rf hollow cathode discharge with an axial nitrogen gas flow. The effect...It is known that gas flow rate is a key factor in controlling industrial plasma processing. In this paper, a 2D PIC/MCC model is developed for an rf hollow cathode discharge with an axial nitrogen gas flow. The effects of the gas flow rate on the plasma parameters are calculated and the results show that: with an increasing flow rate, the total ion(N+2, N+) density decreases, the mean sheath thickness becomes wider, the radial electric field in the sheath and the axial electric field show an increase, and the energies of both kinds of nitrogen ions increase;and, as the axial ion current density that is moving toward the ground electrode increases, the ion current density near the ground electrode increases. The simulation results will provide a useful reference for plasma jet technology involving rf hollow cathode discharges in N2.展开更多
To improve the utilization rate of plasma active species,in this study,a closed non-uniform air gap is formed by a flowing water film electrode and a sawtooth insulating dielectric layer to realize the diffuse glow di...To improve the utilization rate of plasma active species,in this study,a closed non-uniform air gap is formed by a flowing water film electrode and a sawtooth insulating dielectric layer to realize the diffuse glow discharge in the atmosphere.Firstly,the electric field distribution characteristics of non-uniform air gap in the sawtooth dielectric layer are studied,and the influence of aspect ratio on the characteristics of diffuse discharge plasma is discussed.Subsequently,the effects of wire mesh,the inclination angle of the dielectric plate,and liquid inlet velocity on the flow characteristics of the water film electrode are analyzed.The results show that the non-uniform electric field distribution formed in the sawtooth groove can effectively inhibit the filamentous discharge,and the 1 mm flowing water film is directly used as the electrode,and high-active plasma is formed directly on the lower surface of the water film.In addition,a plasma flowing water treatment device is built to treat the methyl orange solution and observe its decolorization effect.The experimental results show that after 50 min of treatment,the decolorization rate of the methyl orange solution reaches 96%,which provides a new idea for industrial applications of wastewater treatment.展开更多
Based on isentropic flow and thermal equilibrium assumptions, a model was derived to calculate discharge flow rate, which unified the rules of room temperature water discharge, high temperature and high pressure water...Based on isentropic flow and thermal equilibrium assumptions, a model was derived to calculate discharge flow rate, which unified the rules of room temperature water discharge, high temperature and high pressure water discharge, two-phase critical flow, saturated steam and superheated steam critical flow, and gave a method to calculate critical condition. Because of the influence of friction, the entropy is increased in the actual discharge process, and the discharge flow rate in thermal equilibrium condition can be obtained by the original model multiplied by an appropriate correction coefficient. The model calculated results agreed well with the experiment data of long nozzle critical flow.展开更多
In this paper, aerodynamic actuation characteristics of radio-frequency(RF) discharge plasma are studied and a method is proposed for shock wave control based on RF discharge. Under the static condition, a RF diffuse ...In this paper, aerodynamic actuation characteristics of radio-frequency(RF) discharge plasma are studied and a method is proposed for shock wave control based on RF discharge. Under the static condition, a RF diffuse glow discharge can be observed; under the supersonic inflow, the plasma is blown downstream but remains continuous and stable.Time-resolved schlieren is used for flow field visualization. It is found that RF discharge not only leads to continuous energy deposition on the electrode surface but also induces a compression wave. Under the supersonic inflow condition, a weak oblique shock wave is induced by discharge. Experimental results of the shock wave control indicate that the applied actuation can disperse the bottom structure of the ramp-induced oblique shock wave, which is also observed in the extracted shock wave structure after image processing. More importantly, this control effect can be maintained steadily due to the continuous high-frequency(MHz) discharge. Finally, correlations for schlieren images and numerical simulations are employed to further explore the flow control mechanism. It is observed that the vortex in the boundary layer increases after the application of actuation, meaning that the boundary layer in the downstream of the actuation position is thickened. This is equivalent to covering a layer of low-density smooth wall around the compression corner and on the ramp surface, thereby weakening the compressibility at the compression corner. Our results demonstrate the ability of RF plasma aerodynamic actuation to control the supersonic airflow.展开更多
Ozone production utilizing surface dielectric barrier discharge(SDBD) was experimental studied for different flow patterns considering the influences of transversal flow, lateral flow and different lateral flow posi...Ozone production utilizing surface dielectric barrier discharge(SDBD) was experimental studied for different flow patterns considering the influences of transversal flow, lateral flow and different lateral flow positions. Results show that the flow patterns have a remarkable impact on the ozone yield by affecting the uniformity and turbulence of gas flow. Meanwhile, distributing the O2 flow rate according to the intensity of the plasma reaction would also increase the generation efficiency of SDBD for ozone production. By improving the uniformity and introducing the lateral flow to the transversal flow, the highest ozone yield was obtained in flow pattern ‘F’. In this case, the ozone yield increased by 28.4% to 131 g kWh-1 from 102.8 g k Wh-1 in flow pattern ‘A’.展开更多
The mixing characteristics of particles such as dredged sediment of variable size discharged into cross flow are studied by a 3D numerical modal, which is developed to model the particle-fluid two-phase flow. The Eule...The mixing characteristics of particles such as dredged sediment of variable size discharged into cross flow are studied by a 3D numerical modal, which is developed to model the particle-fluid two-phase flow. The Eulerian method with the modified k- ε parameterization of turbulence for the fluid phase is used to solve fluid phase, while a Lagrangian method for the sohd phase (particles), both the processes are coupled through the momentmn sources. In the model the wake turbulence induced by particles has been included as additional source term in the k - ε model; and the variable drift velocities of the particles are treated efficiently by the Lagrangian method in which the particles are tracked explicitly and the diffusion process is approximated by a random walk model. The hydrodynamic behavior of dumping a cloud of particles is governed by the total buoyancy of the cloud, the drag force on each particle and the velocity of cross-flow. The computed results show a roughly linear relationship between the displacement of the frontal position and the longitudi- nal width of the particle cloud. The particle size in the cloud and the velocity of cross flow dominate the flow behavior. The computed results are compared with the results of laboratory experiments and satisfactory agreement is obtained.展开更多
As a new method to cure acute respiratory distress syndrome (ARDS), high blood pressure and some illnesses related to the lung, NO has recently received more attention. Thermal plasmas produced by arc discharge can ...As a new method to cure acute respiratory distress syndrome (ARDS), high blood pressure and some illnesses related to the lung, NO has recently received more attention. Thermal plasmas produced by arc discharge can create medical NO, but the concentration of NO2 produced by arc discharge must be controlled simultaneously. This paper investigates the characteristics and regulations of NO production at different flow distribution by pulsed arc discharge in dry air with a special pulsed power, The experimental results show that the flow distribution has a considerable effect on the NO concentration, the stabilization of NO. The production of NO2 could be controlled and the ratio of NO2/NO was decreased to about 10% in the arc discharge. Therefore, the arc discharge could produce stable inhaled NO for medical treatment by changing the flow distribution.展开更多
A direct current(DC) source excited plasma jet consisting of a hollow needle anode and a plate cathode has been developed to form a diffuse discharge plume in ambient air with flowing argon as the working gas.Using ...A direct current(DC) source excited plasma jet consisting of a hollow needle anode and a plate cathode has been developed to form a diffuse discharge plume in ambient air with flowing argon as the working gas.Using optical and electrical methods,the discharge characteristics are investigated for the diffuse plasma plume.Results indicate that the discharge has a pulse characteristic,under the excitation of a DC voltage.The discharge pulse corresponds to the propagation process of a plasma bullet travelling from the anode to the cathode.It is found that,with an increment of the gas flow rate,both the discharge plume length and the current peak value of the pulsed discharge decrease in the laminar flow mode,reach their minima at about1.5 L/min,and then slightly increase in the turbulent mode.However,the frequency of the pulsed discharge increases in the laminar mode with increasing the argon flow rate until the argon flow rate equals to about 1.5 L/min,and then slightly decreases in the turbulent mode.展开更多
基金funded by the National Natural Science Foundation of China(Grant No.42201095)the Second Tibetan Plateau Scientific Expedition and Research(STEP)Program(Grant No.2019QZKK0902)the Postdoctoral Special Funding Project of Sichuan Province(Funding No.TB2023028).
文摘For the basins with debris flow development,its channel terrain exhibits a tortuous shape,which significantly restricts the movement of debris flows and leads to severe erosion effects on the concave bank.Therefore,this study aims to analyze the shear force of debris flows within the bend channel.We established the relationship between the shear force and bend curvature through laboratory experiments.Under the long-term erosion by debris flows,the curvature radius of bends gradually increases,however,when this increasing trend reaches an equilibrium state with the intensity of debris flow discharge,there will be no significant change in curvature radius.In general,the activity pattern and discharges of debris flows would remain relatively stable.Hence,we can infer the magnitude of debris flow discharges from the terrain parameters of the bend channel.
基金supported by the National Science Fund for Distinguished Young Scholars(No.51925703)National Natural Science Foundation of China(Nos.52022096 and 52261145695)。
文摘The environmental contamination caused by antibiotics is increasingly conspicuous due to their widespread manufacture and misuse. Plasma has been employed in recent years for the remediation of antibiotic pollution in the environment. In this work, a falling-film dielectric barrier discharge was used to degrade the antibiotic tetracycline(TC) in water. The reactor combined the gas-liquid discharge and active gas bubbling to improve the TC degradation performance. The discharge characteristics, chemical species’ concentration, and degradation rates at different parameters were systematically studied. Under the optimized conditions(working gas was pure oxygen, liquid flow rate was 100 mL/min, gas flow rate was 1 L/min,voltage was 20 kV, single treatment), TC was removed beyond 70% in a single flow treatment with an energy efficiency of 145 mg/(kW·h). The reactor design facilitated gas and liquid flow in the plasma area to produce more ozone in bubbles after a single flow under pure oxygen conditions, affording fast TC degradation. Furthermore, long-term stationary experiment indicated that long-lived active species can sustain the degradation of TC. Compared with other plasma treatment systems, this work offers a fast and efficient degradation method, showing significant potential in practical industrial applications.
基金financially supported by the National Natural Science Foundation of China (Grant No. 41772276)Key R&D project of Zhejiang Province (Grant No. 2017C03006)China Postdoctoral Science Foundation (Grant No. 2019M652083)
文摘Peak discharge plays an important role in triggering channelized debris flows.The rainfall regimes and rainfall characteristics have been demonstrated to have important influences on peak discharge.In order to explore the relationship between rainfall regimes and peak discharge,a measuring system was placed at the outlet of a small,debris flow-prone catchment.The facility consisted of an approximately rectangular stilling basin,ending with a sharp-crested weir.Six runoff events were recorded which provided a unique opportunity for characterizing the hydrological response of the debris flow-prone catchment.Then,a rainfall–runoff model was tested against the flow discharge measurements to have a deep understanding of hydrological response.Based on the calibrated rainfall-runoff model,twelve different artificially set rainfall patterns were regarded as the input parameters to investigate the effect of rainfall regimes on peak discharge.The results show that the rainfall patterns have a significant effect on peak discharge.The rainfall regimes which have higher peak rainfall intensity and peak rainfall point occur at the later part of rainfall process are easy to generate larger peak discharge in the condition of the same cumulative rainfall and duration.Then,in order to explore the relationship between rainfall characteristics and peak discharge under different cumulative precipitation and different duration,167 measured rainfall events were also collected.On the basis of rainfall depth,rainfall duration,and maximum hourly intensity,all the rainfall events were classified into four categories by using K-mean clustering.Rainfall regime 1 was composed of rainfall events with a moderate mean P(precipitation),a moderate D(duration),and a moderate I60(maximum hourly intensity).Rainfall regime 2 was the group of rainfall events with a high mean P,long D.Rainfall regime 3,however,had a low P and a long D.The characteristic of Rainfall regime 4 was high I60 and short duration with large P.The results show that the rainfall regime 2 and 4 are easier to generate peak discharge as the rainfall intensity plays an important role in generating peak discharge.The results in this study have implications for improving peak discharge prediction accuracy in debris flow gully.
基金supported by National Natural Science Foundation of China(No.11175037)National Natural Science Foundation for Young Scientists of China(No.11305017)Special Fund for Theoretical Physics(No.11247239)
文摘The surface dielectric barrier discharge (SDBD) plasma actuator has shown great promise as an aerodynamic flow control device. In this paper, the encapsulated electrode width of a SDBD actuator is changed to study the airflow acceleration behavior. The effects of encapsulated electrode width on the actuator performance are experimentally investigated by measuring the dielectric layer surface potential, time-averaged ionic wind velocity and thrust force. Experimental results show that the airflow velocity and thrust force increase with the encapsulated electrode width. The results can be attributed to the distinct plasma distribution at different encapsulated electrode widths.
基金supported by Funding of Jiangsu Innovation Program for Graduate Education(No. KYLX16_0310)the Fundamental Research Funds for the Central Universities (No. NP2016406)+1 种基金supported by Graduate Innovation Center in NUAA (No. kfjj20170117)China Postdoctoral Science Foundation (No. 2017M610325)
文摘Dielectric barrier discharge (DBD) plasma is one of most promising flow control method for its several advantages. The present work investigates the control authority of nanosecond pulse DBD plasma actuators on a flying wing model's aerodynamic characteristics. The aerodynamic forces and moments are studied by means of experiment and numerical simulation. The numerical simulation results are in good agreement with experiment results. Both results indicate that the NS-DBD plasma actuators have negligible effect on aerodynamic forces and moment at the angles of attack smaller than 16-. However, significant changes can be achieved with actuation when the model's angle of attack is larger than 16° where the flow separation occurs. The spatial flow field structure results from numerical simulation suggest that the volumetric heat produced by NS-DBD plasma actuator changes the local temperature and density and induces several vortex structures, which strengthen the mixing of the shear layer with the main flow and delay separation or even reattach the separated flow.
基金supported by National Natural Science Foundation of China (Grant No. 10802058)
文摘The operating performance of positive discharge blower is markedly influenced by the pulsation of the discharge flow, but difficult to be measured with experimental methods. The internal and discharge flow of positive discharge blower with involute type three-lobe are numerically investigated, both in air cooling and countercurrent cooling conditions by means of computational fluid dynamics (CFD). The unsteady compressible flow equations are solved using RNG x-ε turbulent model. The finite difference method and the second order upwind difference scheme are applied into discrete equations. In the numerical simulation, the dynamic mesh techniques are used to approach the rotating displacement of cell cubage and the alterability of inlet, outlet flow area. The non-uniform mesh is applied to the rotor-stator coupled area. The reliability of the numerical method is verified by simulating the inner flow and comparing with the semi-empirical theory. The flow flux curves and the distributing of velocity vector showed obvious vortex motion in all the discharge process, both in air cooling and countercurrent cooling conditions. These vortexes with different positions, intension and numbers at different rotating angles have remarkable influences on the discharge flux. For air cooling, the vortex produced a second pulsation with big-amplitude in a cycle, and led to the early appearance of maximum of backflow. For countercurrent cooling, the frequency of pulsation increased due to the pre-inflow, but the backflow at the outlet is prevented, also the pulsation strength has greatly decreased.
文摘This study investigate the relationships between geomorphometric properties and the minimum low flow discharge of undisturbed drainage basins in the Taman Bukit Cahaya Seri Alam Forest Reserve, Peninsular Malaysia. The drainage basins selected were third-order basins so as to facilitate a common base for sampling and performing an unbiased statistical analyses. Three levels of relationships were observed in the study. Significant relationships existed between the geomorphometric properties as shown by the correlation network analysis; secondly, individual geomorphometric properties were observed to influence minimum flow discharge; and finally, the multiple regression model set up showed that minimum flow discharge(Q min) was dependent of basin area(AU), stream length(LS), maximum relief(Hmax), average relief(HAV) and stream frequency(SF). These findings further enforced other studies of this nature that drainage basins were dynamic and functional entities whose operations were governed by complex interrelationships occurring within the basins. Changes to any of the geomorphometric properties would influence their role as basin regulators thus influencing a change in basin response. In the case of the basin's minimum low flow, a change in any of the properties considered in the regression model influenced the “time to peak' of flow. A shorter time period would mean higher discharge, which is generally considered the prerequisite to flooding. This research also conclude that the role of geomorphometric properties to control the water supply within the stream through out the year even though during the drought and less precipitations months. Drainage basins are sensitive entities and any deteriorations involve will generate reciprocals and response to the water supply as well as the habitat within the areas.
基金supported by the National Natural Science Foundation of China(Grants No.41006046and51061130545)the Special Fund for Public Welfare Industry of Ministry of Water Resources of China(GrantNo.201301072)+1 种基金the New Teachers'Fund for Doctor Stations of the Ministry of Education of China(GrantNo.20100094120008)the Special Fund of State Key Laboratory of Hydrology-Water Resources and Hydraulic Engineering of Hohai University(Grants No.2009586712and2009585812)
文摘Flow discharge from the river basin into the sea has severe impacts on the immediate vicinity of river channels, estuaries, and coastal areas. This paper analyzes the features and temporal trends of flow discharge at Pearl River's three main gauge stations: the Wuzhou, Shijiao, and Boluo gauge stations on the West River, North River, and East River, respectively. The results show no significant trend in annual mean discharge into the sea at the three gauge stations. Changes of monthly mean discharge at the Boluo Gauge Station are evident, and a majority of monthly discharge in the dry season displays significant increasing trends. Furthermore, changes of the extreme discharge are quite evident, with a significant decreasing trend in the annual maximum discharge and a significant increasing trend in the minimum one. The significantly decreasing ratio of the flood discharge to annual discharge at the Boluo Gauge Station indicates that the flow discharge from the East River has increased in the dry season and decreased in the flood season since the construction of dams and reservoirs. At the other two gauge stations, the Wuzhou and Shijiao gauge stations, the seasonal discharge generally does not change perceptibly. Human impacts, especially those pertaining to reservoir and dam construction, appear to be responsible for the seasonal variation of flow discharge. The results indicate that the construction and operation of dams and reservoirs in the East River have a greater influence on flow discharge, which can well explain why the seasonal variation of flow discharge from the East River is more evident.
基金supported by National Natural Science Foundation of China (Nos. 61971345 and 52107174)。
文摘The three-electrode sliding dielectric barrier discharge(TES-DBD) plasma actuator significantly enhances the ionization rate and momentum exchange between charged particles and neutral particles by incorporating a parallel DC electrode into the standard DBD design. This design improves the body force and induced jet velocity while allowing flexible control of the induced jet angle, overcoming the limitations of discharge extension and uncontrollable direction in traditional DBD plasma actuators. An integrated plasma power supply has been designed specifically for TES-DBD plasma actuators, streamlining the power supply management. The methodology involves designing the circuit topology for the TES-DBD power supply, followed by simulating and validating its operating principles using Multisim software. The operational performance of the power supply is evaluated through a comprehensive analysis of its electrical,thermal, and aerodynamic properties specific to TES-DBD plasma actuation.
基金supported by Toyota Motor Corporat.ion, Science and Technology Commission of Shanghai Municipality of China (No. 09ZR1421200)Shanghai Maritime University of China (No. 2008462)
文摘Experimental investigation was conducted to study the flow regimes and discharge characteristics of plasma electrohydrodynamic atomization (EHDA) for decane (CloH22) under pulsed applied negative voltage. The experimental parameters were set as the flow rate of decane from 0 mL/min to 10 mL/min and the DC charging voltage from DC 0 V to 12 V with a pulse repetition rates of 200 Hz. The flow regime of decane was observed and the volume-to-electrical charge ratio was measured. Unlike a conventional EHDA system, the results show that a corona discharge was initiated at the edge of the hollow electrode at a specific corona on-set voltage of -17 kV or -20 kV in the case with or without decane flow, respectively. This phenomenon was defined as plasma EHDA.
基金supported by the National Natural Science Foundation of China(Grant Nos.11472306,51407197,and 51507187)
文摘Thermal and induced flow velocity characteristics of radio frequency(RF) surface dielectric barrier discharge(SDBD)plasma actuation are experimentally investigated in this paper. The spatial and temporal distributions of the dielectric surface temperature are measured with the infrared thermography at atmospheric pressure. In the spanwise direction, the highest dielectric surface temperature is acquired at the center of the high voltage electrode, while it reduces gradually along the chordwise direction. The maximum temperature of the dielectric surface raises rapidly once discharge begins.After several seconds(typically 100 s), the temperature reaches equilibrium among the actuator's surface, plasma, and surrounding air. The maximum dielectric surface temperature is higher than that powered by an AC power supply in dozens of k Hz. Influences of the duty cycle and the input frequency on the thermal characteristics are analyzed. When the duty cycle increases, the maximum dielectric surface temperature increases linearly. However, the maximum dielectric surface temperature increases nonlinearly when the input frequency varies from 0.47 MHz to 1.61 MHz. The induced flow velocity of the RF SDBD actuator is 0.25 m/s.
基金National Natural Science Foundation of China(Nos.50676094,50676095,50776086 and 50736007)Fundamental Researches of National Defense in Chinese Academy of Sciences(No.AB20070090)
文摘Influence of plasma actuators as a flow separation control device was investigated experimentally. Hump model was used to demonstrate the effect of plasma actuators on external flow separation, while for internal flow separation a set of compressor cascade was adopted. In order to investigate the modification of the flow structure by the plasma actuator, the flow field was examined non-intrusively by particle image velocimetry measurements in the hump model experiment and by a hot film probe in the compressor cascade experiment. The results showed that the plasma actuator could be effective in controlling the flow separation both over the hump and in the compressor cascade when the incoming velocity was low. As the incoming velocity increased, the plasma actuator was less effective. It is urgent to enhance the intensity of the plasma actuator for its better application. Methods to increase the intensity of plasma actuator were also studied.
基金supported by the Natural Science Foundation of Hebei Province,China(No.A2012205072)
文摘It is known that gas flow rate is a key factor in controlling industrial plasma processing. In this paper, a 2D PIC/MCC model is developed for an rf hollow cathode discharge with an axial nitrogen gas flow. The effects of the gas flow rate on the plasma parameters are calculated and the results show that: with an increasing flow rate, the total ion(N+2, N+) density decreases, the mean sheath thickness becomes wider, the radial electric field in the sheath and the axial electric field show an increase, and the energies of both kinds of nitrogen ions increase;and, as the axial ion current density that is moving toward the ground electrode increases, the ion current density near the ground electrode increases. The simulation results will provide a useful reference for plasma jet technology involving rf hollow cathode discharges in N2.
基金financially supported by National Natural Science Foundation of China(No.51577011)。
文摘To improve the utilization rate of plasma active species,in this study,a closed non-uniform air gap is formed by a flowing water film electrode and a sawtooth insulating dielectric layer to realize the diffuse glow discharge in the atmosphere.Firstly,the electric field distribution characteristics of non-uniform air gap in the sawtooth dielectric layer are studied,and the influence of aspect ratio on the characteristics of diffuse discharge plasma is discussed.Subsequently,the effects of wire mesh,the inclination angle of the dielectric plate,and liquid inlet velocity on the flow characteristics of the water film electrode are analyzed.The results show that the non-uniform electric field distribution formed in the sawtooth groove can effectively inhibit the filamentous discharge,and the 1 mm flowing water film is directly used as the electrode,and high-active plasma is formed directly on the lower surface of the water film.In addition,a plasma flowing water treatment device is built to treat the methyl orange solution and observe its decolorization effect.The experimental results show that after 50 min of treatment,the decolorization rate of the methyl orange solution reaches 96%,which provides a new idea for industrial applications of wastewater treatment.
文摘Based on isentropic flow and thermal equilibrium assumptions, a model was derived to calculate discharge flow rate, which unified the rules of room temperature water discharge, high temperature and high pressure water discharge, two-phase critical flow, saturated steam and superheated steam critical flow, and gave a method to calculate critical condition. Because of the influence of friction, the entropy is increased in the actual discharge process, and the discharge flow rate in thermal equilibrium condition can be obtained by the original model multiplied by an appropriate correction coefficient. The model calculated results agreed well with the experiment data of long nozzle critical flow.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11472306,51407197,and 51507187)
文摘In this paper, aerodynamic actuation characteristics of radio-frequency(RF) discharge plasma are studied and a method is proposed for shock wave control based on RF discharge. Under the static condition, a RF diffuse glow discharge can be observed; under the supersonic inflow, the plasma is blown downstream but remains continuous and stable.Time-resolved schlieren is used for flow field visualization. It is found that RF discharge not only leads to continuous energy deposition on the electrode surface but also induces a compression wave. Under the supersonic inflow condition, a weak oblique shock wave is induced by discharge. Experimental results of the shock wave control indicate that the applied actuation can disperse the bottom structure of the ramp-induced oblique shock wave, which is also observed in the extracted shock wave structure after image processing. More importantly, this control effect can be maintained steadily due to the continuous high-frequency(MHz) discharge. Finally, correlations for schlieren images and numerical simulations are employed to further explore the flow control mechanism. It is observed that the vortex in the boundary layer increases after the application of actuation, meaning that the boundary layer in the downstream of the actuation position is thickened. This is equivalent to covering a layer of low-density smooth wall around the compression corner and on the ramp surface, thereby weakening the compressibility at the compression corner. Our results demonstrate the ability of RF plasma aerodynamic actuation to control the supersonic airflow.
基金supported by National Natural Science Foundation of China(No.51776185)Zhejiang Provincial Natural Science Foundation(LR16E060001)
文摘Ozone production utilizing surface dielectric barrier discharge(SDBD) was experimental studied for different flow patterns considering the influences of transversal flow, lateral flow and different lateral flow positions. Results show that the flow patterns have a remarkable impact on the ozone yield by affecting the uniformity and turbulence of gas flow. Meanwhile, distributing the O2 flow rate according to the intensity of the plasma reaction would also increase the generation efficiency of SDBD for ozone production. By improving the uniformity and introducing the lateral flow to the transversal flow, the highest ozone yield was obtained in flow pattern ‘F’. In this case, the ozone yield increased by 28.4% to 131 g kWh-1 from 102.8 g k Wh-1 in flow pattern ‘A’.
基金This work was supported by a grant fromthe Research Grant Council of the Hong Kong Special Administrative Region(Project No5033/98E)
文摘The mixing characteristics of particles such as dredged sediment of variable size discharged into cross flow are studied by a 3D numerical modal, which is developed to model the particle-fluid two-phase flow. The Eulerian method with the modified k- ε parameterization of turbulence for the fluid phase is used to solve fluid phase, while a Lagrangian method for the sohd phase (particles), both the processes are coupled through the momentmn sources. In the model the wake turbulence induced by particles has been included as additional source term in the k - ε model; and the variable drift velocities of the particles are treated efficiently by the Lagrangian method in which the particles are tracked explicitly and the diffusion process is approximated by a random walk model. The hydrodynamic behavior of dumping a cloud of particles is governed by the total buoyancy of the cloud, the drag force on each particle and the velocity of cross-flow. The computed results show a roughly linear relationship between the displacement of the frontal position and the longitudi- nal width of the particle cloud. The particle size in the cloud and the velocity of cross flow dominate the flow behavior. The computed results are compared with the results of laboratory experiments and satisfactory agreement is obtained.
基金National Natural Science Foundation of China (Nos.50677026 and 50347009)the National Key Technologies R&D Program Special Foundation of China (No.2003A12)
文摘As a new method to cure acute respiratory distress syndrome (ARDS), high blood pressure and some illnesses related to the lung, NO has recently received more attention. Thermal plasmas produced by arc discharge can create medical NO, but the concentration of NO2 produced by arc discharge must be controlled simultaneously. This paper investigates the characteristics and regulations of NO production at different flow distribution by pulsed arc discharge in dry air with a special pulsed power, The experimental results show that the flow distribution has a considerable effect on the NO concentration, the stabilization of NO. The production of NO2 could be controlled and the ratio of NO2/NO was decreased to about 10% in the arc discharge. Therefore, the arc discharge could produce stable inhaled NO for medical treatment by changing the flow distribution.
基金supported by National Natural Science Foundation of China(Nos.10805013,11375051)Funds for Distinguished Young Scientists of Hebei Province,China(No.A2012201045)+1 种基金Department of Education for Outstanding Youth Project of China(No.Y2011120)Youth Project of Hebei University of China(No.2011Q14)
文摘A direct current(DC) source excited plasma jet consisting of a hollow needle anode and a plate cathode has been developed to form a diffuse discharge plume in ambient air with flowing argon as the working gas.Using optical and electrical methods,the discharge characteristics are investigated for the diffuse plasma plume.Results indicate that the discharge has a pulse characteristic,under the excitation of a DC voltage.The discharge pulse corresponds to the propagation process of a plasma bullet travelling from the anode to the cathode.It is found that,with an increment of the gas flow rate,both the discharge plume length and the current peak value of the pulsed discharge decrease in the laminar flow mode,reach their minima at about1.5 L/min,and then slightly increase in the turbulent mode.However,the frequency of the pulsed discharge increases in the laminar mode with increasing the argon flow rate until the argon flow rate equals to about 1.5 L/min,and then slightly decreases in the turbulent mode.