The centrifugal pump is a prevalent power equipment widely used in different engineering patterns,and the impeller blade wrap angle significantly impacts its performance.A numerical investigation was conducted to anal...The centrifugal pump is a prevalent power equipment widely used in different engineering patterns,and the impeller blade wrap angle significantly impacts its performance.A numerical investigation was conducted to analyze the influence of the blade wrap angle on flow characteristics and energy distribution of a centrifugal pump evaluated as a low specific speed with a value of 69.This study investigates six impellermodels that possess varying blade wrap angles(95°,105°,115°,125°,135°,and 145°)that were created while maintaining the same volute and other geometrical characteristics.The investigation of energy loss was conducted to evaluate the values of total and entropy generation rates(TEG,EGR).The fluid-structure interaction was considered numerically using the software tools ANSYS Fluent and ANSYSWorkbench.The elastic structural dynamic equation was used to estimate the structural response,while the shear stress transport k–ωturbulence model was utilized for the fluid domain modeling.The findings suggest that the blade wrap angle has a significant influence on the efficiency of the pump.The impeller featuring a blade wrap angle of 145°exhibits higher efficiency,with a notable increase of 3.76%relative to the original model.Variations in the blade wrap angle impact the energy loss,shaft power,and pump head.The model with a 145°angle exhibited a maximum equivalent stress of 14.8MPa and a total deformation of 0.084 mm.The results provide valuable insights into the intricate flow mechanism of the centrifugal pump,particularly when considering various blade wrap angles.展开更多
The hydraulic performance test of the mixed-flow pump has been carried out through selecting different blade tip clearances and various blade angle errors.The ratio of the mixed-flow pump efficiency reduction and the ...The hydraulic performance test of the mixed-flow pump has been carried out through selecting different blade tip clearances and various blade angle errors.The ratio of the mixed-flow pump efficiency reduction and the blade tip clearance variation(η/δ) varies with the flow rate coefficient revealing a parabolic trend.An empirical equation has been developed for the mixed-flow pump model by parabolic fitting.For the same blade tip clearance variation δ,the mixed-flow pump efficiency reduction η increases rapidly as the flow rate rises.For any given flow rate,the efficiency,the head and the shaft power of the mixed-flow pump all decrease with the increase of the blade tip clearance.Among them,the efficiency reduction η varies approximately linearly with the blade tip clearance variation δ.When the angle of an individual blade of the mixed-flow pump has a deviation,the performance curves will move and change.These curves have consistent change directions with the performance curves under the condition of all the blades rotated at the same time,but have smaller offset and lower range of variation.When an individual blade angle error changes to ±2°,the optimal efficiency of the mixed-flow pump will have no significant difference.When the individual blade angle error increases to ±4°,the optimal efficiency will decrease by 1%.展开更多
The existing research on improving the hydraulic performance of centrifugal pumps mainly focuses on the design method and the parameter optimization. The traditional design method for centrifugal impellers relies more...The existing research on improving the hydraulic performance of centrifugal pumps mainly focuses on the design method and the parameter optimization. The traditional design method for centrifugal impellers relies more on experience of engineers that typically only satisfies the continuity equation of the fluid. In this study, on the basis of the direct and inverse iteration design method which simultaneously solves the continuity and motion equations of the fluid and shapes the blade geometry by controlling the wrap angle, three centrifugal pump impellers are designed by altering blade wrap angles while keeping other parameters constant. The three-dimensional flow fields in three centrifugal pumps are numerically simulated, and the simulation results illustrate that the blade with larger wrap angle has more powerful control ability on the flow pattern in impeller. The three pumps have nearly the same pressure distributions at the small flow rate, but the pressure gradient increase in the pump with the largest wrap angle is smoother than the other two pumps at the design and large flow rates. The pump head and efficiency are also influenced by the blade wrap angle. The highest head and efficiency are also observed for the largest angle. An experiment rig is designed and built to test the performance of the pump with the largest wrap angle. The test results show that the wide space of its efficiency area and the stability of its operation ensure the excellent performance of the design method and verify the numerical analysis. The analysis on influence of the blade wrap angle for centrifugal pump performance in this paper can be beneficial to the optimization design of the centrifugal pump.展开更多
During transportation of salt aqueous solutions with centrifugal pump, crystallization phenomenon is frequently encountered. For this kind of two-phase flow, it is difficult to be accurately modeled since there are va...During transportation of salt aqueous solutions with centrifugal pump, crystallization phenomenon is frequently encountered. For this kind of two-phase flow, it is difficult to be accurately modeled since there are various medium properties and phase change characteristics. In view of experiment, several problems are hampering the implementation of precise measurement. Influences of blade outlet angle and medium temperature on crystallization rate were studied. Sodium sulfate solution was applied to simulate practical fluid in chemical industry. Particle image velocimetry(PIV) was employed to measure velocity distributions in rotating impeller. Crystallization processes in three impellers with different blade outlet angles were investigated. Relations among crystallization and flow parameters such as temperature and velocity were obtained. With the same blade wrap angle, when blade outlet angle is larger, diffusion of single flow passage gets stronger, relative velocity at blade outlet decreases and large scale vortex tends to appear near the blade working surface. For the impact of volume effect of particle phase on fluid viscosity, both liquid and solid phase velocities decrease with continual forming and growing of crystal particles. Velocity of solid phase is greater than that of liquid phase and its direction leans more closely to blade working surface. Solid particles tend to move towards blade working surface, as is more obvious in the impeller with large blade outlet angle. Therefore, collision between solid particles with stem part of blade working surface is more intensive in impeller with large blade outlet angle. Concerning transportation of salt aqueous solution, accurate PIV measurement is conducted in centrifugal impellers with different blade outlet angles. The results are useful and instructive in relevant engineering design and operation.展开更多
As an important parameter of compressor impeller, the design value of blade outlet backsweep angle has a great influence on the performance of impeller. In this paper, six impellers with blade outlet backsweep angle ...As an important parameter of compressor impeller, the design value of blade outlet backsweep angle has a great influence on the performance of impeller. In this paper, six impellers with blade outlet backsweep angle β<sub>2B</sub> equal to 0°, 10°, 20°, 30°, 40°, and 50° were designed to evaluate the influences of impeller backsweep angle β<sub>2B</sub> on the performance, characteristics of gas flow and equivalent stress using computational fluid dynamics (CFD) and finite element analysis (FEA). Results indicated that the performance curve for the outlet backsweep blade angle β<sub>2B</sub> of 50° has the largest stable operating range. The isentropic efficiency of the impeller with backsweep angle β<sub>2B</sub> equal to 40° is 16.8% - 25.9% higher than that of the impeller with backsweep angle β<sub>2B</sub> equal to 0°. When the blade outlet backsweep angle is 30°, the equivalent stress distribution of the impeller is more uniform, the maximum equivalent stress is the smallest.展开更多
Aiming at the paddle tilt angle of the spray-blowing agitation composite process,the four-blade stirring and blowing composite desulfurization agitator was chosen as the research object,and the computational fluid dyn...Aiming at the paddle tilt angle of the spray-blowing agitation composite process,the four-blade stirring and blowing composite desulfurization agitator was chosen as the research object,and the computational fluid dynamics numerical simulation was used to investigate the changes in flow field velocity,turbulent kinetic energy magnitude,and distribution caused by the blade tilt angle.Furthermore,the impact of blade tilt angle on the flow fragmentation behavior of individual bubbles and the coalescence process of multiple bubbles at different positions was studied.Under the same stirring and blowing process parameters,with the increase in the blade tilt angle of the agitator,the velocity of the flow field and the average turbulent kinetic energy inside the agitator decreased,and the bubble fragmentation speed decreased while the merging speed accelerated.The turbulent kinetic energy at the agitator bottom was greater when the blade tilt angle was 3.2°compared to when it was 13.2°,while the turbulent kinetic energy at the agitator upper part was relatively smaller.The results for single bubbles represented the state and trajectory of the bubble fragmentation process,and the results for multiple bubbles illustrated the state and trajectory of the bubble aggregation process.展开更多
Multistage centrifugal impellers with four different skew angles were investigated by using computational fluid dynamics.The purpose of this work is to investigate the influences of lean angle at the blade tip of the ...Multistage centrifugal impellers with four different skew angles were investigated by using computational fluid dynamics.The purpose of this work is to investigate the influences of lean angle at the blade tip of the impeller inlet.Four variations of lean angles,that is,8°,10°,15° and 20°,were made at first stage impeller.Reynolds Average Navier Stokes equation was used in simulation together with a shear?stress transport(SST) k-w turbulence model and mixing-plane approach,respectively.Three dimensional fluid flows were simplified using periodic model to reduce the computational cost and time required.A good performance was expected that the secondary flow can be effectively reduced in the flow passage of the impeller without excessive increase in manufacturing cost caused by the secondary flow.The results show that secondary flow affects the main flow intricately to form vortices or having non-uniform velocity in the flow passage,which in turn results in substantial fluid energy loss not only in the impeller but also in the guide vane downstream of impeller.The numerical solutions were performed and allowed the optimum design and operating conditions to be obtained.展开更多
Baoying pumping station is a part of source pumping stations in East Route Project of South-to-North Water Transfer in China. Aiming at the characteristics of head varying, and making use of the function of pump adjus...Baoying pumping station is a part of source pumping stations in East Route Project of South-to-North Water Transfer in China. Aiming at the characteristics of head varying, and making use of the function of pump adjustable blade, mathematical models of pumping station optimal operation are established and solved with genetic algorithm. For different total pumping discharge and total pumping volume of water per day, in order to minimize pumping station operation cost, the number and operation duties of running pump units are respectively determined at different periods of time in a day. The results indicate that the saving of electrical cost is significantly effected by the schemes of adjusting blade angles and time-varying electrical price when pumping certain water volume of water per day, and compared with conventional operation schemes (namely, the schemes of pumping station operation at design blade angles based on certain pumping discharge), the electrical cost is saved by 4.73%-31.27%. Also, compared with the electrical cost of conventional operation schemes, the electrical cost is saved by 2.03%-5.79% by the schemes of adjusting blade angles when pumping certain discharge.展开更多
Contra-rotating axial flow fan is a kind of the vital equipment in coal mines. Their work conditions directly affect the safety of staff and production. In the paper, the performance of the contra-rotating axial flow ...Contra-rotating axial flow fan is a kind of the vital equipment in coal mines. Their work conditions directly affect the safety of staff and production. In the paper, the performance of the contra-rotating axial flow fan is experi- mentally investigated. The study is focused on the fan performance, the shaft power and the match between the motor and fan efficiency at different blade angles. The results show that the blade angle 43°/26° has the best aerodynamic perfor- mance. The first engine has a greater impact on the fan than the second one. The blade angle with the best aerodynamic performance does not necessarily correspond to the one with the best match between the motor and fan efficiency. The blade angle 43°/24° is the best choice for the operation of the fan in the present study.展开更多
Mini turbo-pumps having a diameter smaller than 100mm are employed in many fields;automobile radiator pump,ventricular assist pump,cooling pump for electric devices,washing machine pump and so on.Further,the needs for...Mini turbo-pumps having a diameter smaller than 100mm are employed in many fields;automobile radiator pump,ventricular assist pump,cooling pump for electric devices,washing machine pump and so on.Further,the needs for mini turbo-pumps would become larger with the increase of the application of it for electrical machines.It is desirable that the mini turbo-pump design is as simple as possible due to restriction to make precise manufactures.But the design method for the mini turbo-pump is not established because the internal flow condition for these small-sized fluid machineries is not clarified and conventional theory is not conductive for small-sized pumps.Three types of rotors with different outlet angles are prepared for an experiment and a numerical analysis.The performance tests are conducted with these rotors in order to investigate the effect of the blade outlet angle on performance and internal flow condition of mini turbo-pumps.It is clarified from the experimental results that head of the mini turbo-pump increases and maximum efficiency flow rate shifts to larger flow rate according to the increase of the blade outlet angle,however the maximum efficiency decreases with the increase of it.In the present paper,the performance of the mini turbo-pump is shown and the internal flow conditions are clarified with the results of the experiment and the numerical flow analysis.Furthermore,the effects of the blade outlet angle on the performance are investigated and high performance design with simple structure for the mini turbo-pump would be considered.展开更多
In order to analyze the influence of blade outlet angle on inner flow field and performance of low-specific-speed centrifugal pump, the flow field in the pump with different blade outlet angles 32.5°and 39° ...In order to analyze the influence of blade outlet angle on inner flow field and performance of low-specific-speed centrifugal pump, the flow field in the pump with different blade outlet angles 32.5°and 39° was numerically calculated. The external performance experiment was also carried out on the pump. Based on SIMPLEC algorithm, time-average N-S equation and the rectified k-ε turbulent model were adopted during the process of computation. The distributions of velocity and pressure in pumps with different blade outlet angles were obtained by calculation. The numerical results show that backflow areas exist in the two impellers, while the inner flow has a little improvement in the impeller with larger blade outlet angle. Blade outlet angle has a certain influence on the static pressure near the long-blade leading edge and tongue, but it has little influence on the distribution of static pressure in the passages of impeller. The experiment results show that the low-specific-speed centrifugal pump with larger blade outlet angle has better hydraulic performance.展开更多
By model test and numerical simulation, this paper analyzed the effects of different blades with varying rotation angle deviations on the hydraulic performance of a mixed-flow pump. It was found that when some blades ...By model test and numerical simulation, this paper analyzed the effects of different blades with varying rotation angle deviations on the hydraulic performance of a mixed-flow pump. It was found that when some blades had rotation angle deviations, the hydraulic performance curves of the mixed-flow pump would move. With a positive deviation, the curves moved towards the large flow rate; with a negative deviation, the curves moved towards the small flow rate. When some blades had rotation angle deviations, the symmetry and uniformity of the pressure distribution inside the mixed-flow pump flow passage both decreased; the larger the deviation, the greater the decrease. When a single blade had a large rotation angle deviation, a rather clear low pressure area was formed, lowering the cavitation performance. When two adjacent blades changed simultaneously, under the small flow rate condition, adverse pressure gradient and flow separation occurred in the flow field, and a hump appeared in the head curve and the operation stability of the mixed-flow pump dropped significantly. Near the best efficiency point(BEP), the simultaneous change of two alternate blades produced a more significant change of pressure in the flow passage, with an even larger area. Compared to the effect of two adjacent blades, two alternate blades, when changed simultaneously, made the mixed-flow pump slightly less efficient, but with a flatter efficiency curve and relatively wider high efficiency area. By fitting the test results, a functional relation among the BEP of the mixed-flow pump QBEP, the number of deviated blades N, and blade rotation angle deviation α was established, thus realizing an effective prediction of the BEP of the mixed-flow pump when blade rotation angles have deviations.展开更多
It is well known that fan/compressor blade flutter stability increases with the increase of reduced frequency.Less well-known is that the least stable inter blade phase angle(IBPA)increases with the drop of reduced fr...It is well known that fan/compressor blade flutter stability increases with the increase of reduced frequency.Less well-known is that the least stable inter blade phase angle(IBPA)increases with the drop of reduced frequency.However,it is quite striking that little can be found in the open literature about the mechanism to the observations.In this paper,a numerical investigation is carried out to uncover the mechanism of the effect of reduced frequency on flutter stability and the least stable IBPA.The NASA rotor 67 has been used as the test vehicle with its first bending and torsion modes being considered.The time domain harmonic balance method together with the influence coefficient method is used to obtain the worksum-IBPA curves for all cases.It is found that:1)the deterioration of flutter stability with the decrease of reduced frequency is dictated by the dominant decrease of aerodamping due to a blade own vibration;2)the increase of the least stable IBPA with the decrease of reduced frequency arises largely from the increase of the least stable IBPA of the aerodamping from the nearest blade on a blade pressure side.展开更多
In order to study the variation of brake torque,vibration,pressure fluctuation,exterior noise and internal flow for a hydraulic retarder with different inclination angles and liquid-filled amount,a bench-scale hydraul...In order to study the variation of brake torque,vibration,pressure fluctuation,exterior noise and internal flow for a hydraulic retarder with different inclination angles and liquid-filled amount,a bench-scale hydraulic retarder was built.The INV3020 data collection system was used for the synchronous acquisition of brake torque,vibration,pressure fluctuation and exterior noise signals.Experiments were performed with different inclination angles(90°and 75°)and six liquid-filled amount(50 vol%,60 vol%,70 vol%,80 vol%,90vol%and 100 vol%).The torque-volume ratio was proposed to accurately analyze the influence of inclination angle on the liquid volume in stator and rotor and the brake performance.Mixture multiphase flow model was employed to capture the volume and velocity distribution.The research shows that the brake performance improves and the vibration increases with the decrease of inclination angle and the increase of liquid-filled amount.The pressure fluctuation increases as the liquid-filled amount increases,while the lower inclination angle effectively lowers the pressure fluctuation amplitude.The sound pressure level trends upward with increasing liquid-filled amount,and the lower inclination angle can effectively reduce the noise.The volume distribution of the liquid phase under different liquid-filled amount is basically consistent.The lower inclination angle can induce more vortexes.展开更多
With the improvement of requirement,design and manufacture technology,aero-engines for the future are characterized by further reduction in fuel consumption,cost,but increment in propulsion efficiency,which leads to u...With the improvement of requirement,design and manufacture technology,aero-engines for the future are characterized by further reduction in fuel consumption,cost,but increment in propulsion efficiency,which leads to ultra-high bypass ratio.The intermediate turbine duct(ITD),which connects the high pressure turbine(HPT) with the low pressure turbine(LPT),has a critical impact on the overall performances of such future engines.Therefore,it becomes more and more urgent to master the design technique of aggressive,even super-aggressive ITDs.Over the last years,a lot of research works about the flow mechanism in the diffuser ducts were carried out.Many achievements were reported,but further investigation should be performed.With the aid of numerical method,this paper focuses on the change of performance and flow field of ITD,as well as nearby turbines,brought by rising angle(RA).Eight ITDs with the same area ratio and length,but different RAs ranges from 8 degrees to 45 degrees,are compared.According to the investigation,flow field,especially outlet Ma of swirl blade is influenced by RA under potential effect,which is advisable for designers to modify HPT rotor blades after changing ITD.In addition to that,low velocity area moves towards upstream until the first bend as RA increases,while pressure loss distribution at S2 stream surface shows that hub boundary layer is more sensitive to RA,and casing layer keeps almost constant.On the other hand,the overall total pressure loss could keep nearly equivalent among different RA cases,which implies the importance of optimization.展开更多
In the cold areas of Northeast China,maize high-stubble cutting is a novel stalk conservation tillage method,in which the maize stalks are under a unilaterally-fixed no-support cutting status.Thus,reducing the cutting...In the cold areas of Northeast China,maize high-stubble cutting is a novel stalk conservation tillage method,in which the maize stalks are under a unilaterally-fixed no-support cutting status.Thus,reducing the cutting resistance and power consumption of maize stalks under this status is very significant for the development of high-efficiency high-stubble cutting devices.Based on a self-designed testing system that highly restored the maize high-stubble cutting conditions and by means of experimental design and mathematic statistics,the effects of working parameters(blade angle,blade shape,cutting speed and cutting angle)on the maximum cutting resistance and power consumption were studied.By analyzing stress conditions during the stalk cutting process,six mathematic models were built to express the relationships between individual factors and the maximum cutting resistance or cutting power consumption.Through model optimization,the parameter combination for optimal cutting performance of maize stalks under unilaterally-fixed no-support cutting status was obtained:blade angle is 18°,blade shape is isosceles triangle,cutting speed is 9.5 m/s,and cutting angle is 75°.Field validation experiments under this parameter combination showed that the maximum cutting resistance was(55.23±3.50)N(declined by 11.04%),and power consumption was(11.41±1.04)J(declined by 16.65%).The research findings can be a reference for the design and development of maize high-stubble cutting devices.展开更多
This paper presents the design of a centrifugal compressor for high-speed turbomachinery.The main focus of the research is to develop a centrifugal compressor with improved aerodynamic performance.As a meridional fram...This paper presents the design of a centrifugal compressor for high-speed turbomachinery.The main focus of the research is to develop a centrifugal compressor with improved aerodynamic performance.As a meridional frame has a significant effect on overall performance of the compressor,special attention has been paid to the end wall contours.The shroud profile is design with bezier curve and hub profile with circular arc contour.The blade angle distribution has been arranged in a manner that it merges with single value at impeller exit.The rake angle is positive at leading edge and negative at trailing edge with identical magnitude.Furthermore,three-dimensional straight line element approach has been used for this design for better manufacturability.The verification of the aerodynamic performance has been carried out using CFD software with consideration of a single blade passage and vaneless diffuser.The result has been compared with matching size aftermarket compressor stage gas stand data.The compressor stage with Trim 55 provides 34%increase in choke flow at 210000 RPM as compared to gas stand data with 87%peak stage efficiency at 110000 RPM.In addition,new surge margin improvement technique has been proposed by means of diffuser enhancement.This technique provides an average of 16%improvement in surge margin compared to standard diffuser stage with 55 trim compressor impeller.The mechanical integrity has been validated at maximum RPM with the aluminum alloy 2014-T6 as a fabrication material.展开更多
In this study,the lock-in phenomenon of Tip Clearance Flow(TCF)instabilities and their relationship to blade vibration are investigated numerically on an axial transonic rotor with a large tip clearance.The capabiliti...In this study,the lock-in phenomenon of Tip Clearance Flow(TCF)instabilities and their relationship to blade vibration are investigated numerically on an axial transonic rotor with a large tip clearance.The capabilities of simulating instability flow and lock-in phenomenon are verified on a transonic rotor and a NACA0012 airfoil by comparing with the test data,respectively.The lock-in phenomenon is first numerically confirmed that may occur to TCF instabilities when its frequency is close to the blade vibration frequency.The lock-in region becomes wider with the vibration amplitude increasing,and it is also affected by modal shapes.For the rotor at the simulation conditions in this study,the bending mode results in a wider lock-in region than the torsional mode.In the lock-in region,the phase difference between the Tip Clearance Vortex(TCV)and the blade vibration changes with the flow condition and the frequency ratio of the blade vibration and the TCV instabilities.The frequency of the TCV instabilities reduces with the mass flow decreasing.Therefore,reducing mass flow and increasing frequency ratio have similar effects on the TCV phase,which causes a significant variation on the unsteady pressure amplitude in the blade tip area.Thus,the aerodynamic damping changes significantly with the TCV phase.The aerodynamic damping displays a nonlinear relationship with the vibration amplitude,and it changes from negative to positive with the vibration amplitude increasing at the same frequency ratio.The negative damping is mainly provided by the tip area of the blade.For unlocked conditions,the period of the TCF instabilities fluctuates over time,and it cannot be directly separated by their frequency features.Inter Blade Phase Angle(IBPA)also has an important influence on the feature of the TCV instabilities.The occurrence of frequency lock-in also requires“appropriate”IBPA.For the examined working conditions,the frequency lock-in occurs under 0 ND(Nodal Diameter),but not under 8 ND.However,no matter 0 ND or 8 ND,the phase of TCV always locks onto the IBPA at the examined conditions.展开更多
The flow characteristics of the centrifugal fans with different blade outlet angles are basically discussed on steady and unsteady simulations for a rectangular casing fan. The blade outlet angles of the impellers are...The flow characteristics of the centrifugal fans with different blade outlet angles are basically discussed on steady and unsteady simulations for a rectangular casing fan. The blade outlet angles of the impellers are 35° and 25° respectively. The unsteady flow behavior in the passage of the impeller 35° is quite different from that in the steady flow behavior. The large flow separation occurs in the steady flow field and unsteady flow field of the impeller 35°, the flow distribution in the circumferential direction varies remarkably and the flow separation on the blade occurs only at the back region of the fan; but the steady flow behavior in the impeller 25° is almost consistent with the unsteady flow behavior, the flow distribution of the circumferential direction doesn't vary much and the flow separation on the blade hardly occurs. When the circumferential variation of the flow in the impeller is large, the steady flow simulation is not coincident to the unsteady flow simulation.展开更多
文摘The centrifugal pump is a prevalent power equipment widely used in different engineering patterns,and the impeller blade wrap angle significantly impacts its performance.A numerical investigation was conducted to analyze the influence of the blade wrap angle on flow characteristics and energy distribution of a centrifugal pump evaluated as a low specific speed with a value of 69.This study investigates six impellermodels that possess varying blade wrap angles(95°,105°,115°,125°,135°,and 145°)that were created while maintaining the same volute and other geometrical characteristics.The investigation of energy loss was conducted to evaluate the values of total and entropy generation rates(TEG,EGR).The fluid-structure interaction was considered numerically using the software tools ANSYS Fluent and ANSYSWorkbench.The elastic structural dynamic equation was used to estimate the structural response,while the shear stress transport k–ωturbulence model was utilized for the fluid domain modeling.The findings suggest that the blade wrap angle has a significant influence on the efficiency of the pump.The impeller featuring a blade wrap angle of 145°exhibits higher efficiency,with a notable increase of 3.76%relative to the original model.Variations in the blade wrap angle impact the energy loss,shaft power,and pump head.The model with a 145°angle exhibited a maximum equivalent stress of 14.8MPa and a total deformation of 0.084 mm.The results provide valuable insights into the intricate flow mechanism of the centrifugal pump,particularly when considering various blade wrap angles.
基金supported by the National Natural Science Foundation of China (Grant No. 51176088)
文摘The hydraulic performance test of the mixed-flow pump has been carried out through selecting different blade tip clearances and various blade angle errors.The ratio of the mixed-flow pump efficiency reduction and the blade tip clearance variation(η/δ) varies with the flow rate coefficient revealing a parabolic trend.An empirical equation has been developed for the mixed-flow pump model by parabolic fitting.For the same blade tip clearance variation δ,the mixed-flow pump efficiency reduction η increases rapidly as the flow rate rises.For any given flow rate,the efficiency,the head and the shaft power of the mixed-flow pump all decrease with the increase of the blade tip clearance.Among them,the efficiency reduction η varies approximately linearly with the blade tip clearance variation δ.When the angle of an individual blade of the mixed-flow pump has a deviation,the performance curves will move and change.These curves have consistent change directions with the performance curves under the condition of all the blades rotated at the same time,but have smaller offset and lower range of variation.When an individual blade angle error changes to ±2°,the optimal efficiency of the mixed-flow pump will have no significant difference.When the individual blade angle error increases to ±4°,the optimal efficiency will decrease by 1%.
基金supported by National Natural Science Foundation of China(Grant Nos.51176088,51179090)National Basic Research Program of China(973 Program,Grant No.2009CB724304)+1 种基金General Financial Grant from the China Postdoctoral Science Foundation(Grant No.2011M500315)Open Research Fund Program of State Key Laboratory of Hydroscience and Engineering of China(Grant No.sklhse-2012-E-02)
文摘The existing research on improving the hydraulic performance of centrifugal pumps mainly focuses on the design method and the parameter optimization. The traditional design method for centrifugal impellers relies more on experience of engineers that typically only satisfies the continuity equation of the fluid. In this study, on the basis of the direct and inverse iteration design method which simultaneously solves the continuity and motion equations of the fluid and shapes the blade geometry by controlling the wrap angle, three centrifugal pump impellers are designed by altering blade wrap angles while keeping other parameters constant. The three-dimensional flow fields in three centrifugal pumps are numerically simulated, and the simulation results illustrate that the blade with larger wrap angle has more powerful control ability on the flow pattern in impeller. The three pumps have nearly the same pressure distributions at the small flow rate, but the pressure gradient increase in the pump with the largest wrap angle is smoother than the other two pumps at the design and large flow rates. The pump head and efficiency are also influenced by the blade wrap angle. The highest head and efficiency are also observed for the largest angle. An experiment rig is designed and built to test the performance of the pump with the largest wrap angle. The test results show that the wide space of its efficiency area and the stability of its operation ensure the excellent performance of the design method and verify the numerical analysis. The analysis on influence of the blade wrap angle for centrifugal pump performance in this paper can be beneficial to the optimization design of the centrifugal pump.
基金supported by National Natural Science Foundation of China (Grant No. 50476068, Grant No. 50776040)Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20060299008)
文摘During transportation of salt aqueous solutions with centrifugal pump, crystallization phenomenon is frequently encountered. For this kind of two-phase flow, it is difficult to be accurately modeled since there are various medium properties and phase change characteristics. In view of experiment, several problems are hampering the implementation of precise measurement. Influences of blade outlet angle and medium temperature on crystallization rate were studied. Sodium sulfate solution was applied to simulate practical fluid in chemical industry. Particle image velocimetry(PIV) was employed to measure velocity distributions in rotating impeller. Crystallization processes in three impellers with different blade outlet angles were investigated. Relations among crystallization and flow parameters such as temperature and velocity were obtained. With the same blade wrap angle, when blade outlet angle is larger, diffusion of single flow passage gets stronger, relative velocity at blade outlet decreases and large scale vortex tends to appear near the blade working surface. For the impact of volume effect of particle phase on fluid viscosity, both liquid and solid phase velocities decrease with continual forming and growing of crystal particles. Velocity of solid phase is greater than that of liquid phase and its direction leans more closely to blade working surface. Solid particles tend to move towards blade working surface, as is more obvious in the impeller with large blade outlet angle. Therefore, collision between solid particles with stem part of blade working surface is more intensive in impeller with large blade outlet angle. Concerning transportation of salt aqueous solution, accurate PIV measurement is conducted in centrifugal impellers with different blade outlet angles. The results are useful and instructive in relevant engineering design and operation.
文摘As an important parameter of compressor impeller, the design value of blade outlet backsweep angle has a great influence on the performance of impeller. In this paper, six impellers with blade outlet backsweep angle β<sub>2B</sub> equal to 0°, 10°, 20°, 30°, 40°, and 50° were designed to evaluate the influences of impeller backsweep angle β<sub>2B</sub> on the performance, characteristics of gas flow and equivalent stress using computational fluid dynamics (CFD) and finite element analysis (FEA). Results indicated that the performance curve for the outlet backsweep blade angle β<sub>2B</sub> of 50° has the largest stable operating range. The isentropic efficiency of the impeller with backsweep angle β<sub>2B</sub> equal to 40° is 16.8% - 25.9% higher than that of the impeller with backsweep angle β<sub>2B</sub> equal to 0°. When the blade outlet backsweep angle is 30°, the equivalent stress distribution of the impeller is more uniform, the maximum equivalent stress is the smallest.
基金supported by the National Natural Science Foundation of China(No.51904069)the Fundamental Research Funds for the Central Universities(No.N2223026)+1 种基金the Development Fund of State Key Laboratory for Clean Utilization of Complex Nonferrous Metal Resources(No.CNMRCUKF2302)the Scientific Research Fund Project of Northeastern University at Qinhuangdao(No.XNY201808).
文摘Aiming at the paddle tilt angle of the spray-blowing agitation composite process,the four-blade stirring and blowing composite desulfurization agitator was chosen as the research object,and the computational fluid dynamics numerical simulation was used to investigate the changes in flow field velocity,turbulent kinetic energy magnitude,and distribution caused by the blade tilt angle.Furthermore,the impact of blade tilt angle on the flow fragmentation behavior of individual bubbles and the coalescence process of multiple bubbles at different positions was studied.Under the same stirring and blowing process parameters,with the increase in the blade tilt angle of the agitator,the velocity of the flow field and the average turbulent kinetic energy inside the agitator decreased,and the bubble fragmentation speed decreased while the merging speed accelerated.The turbulent kinetic energy at the agitator bottom was greater when the blade tilt angle was 3.2°compared to when it was 13.2°,while the turbulent kinetic energy at the agitator upper part was relatively smaller.The results for single bubbles represented the state and trajectory of the bubble fragmentation process,and the results for multiple bubbles illustrated the state and trajectory of the bubble aggregation process.
基金Project(NRF-2010-013-D00007) supported by the National Research Foundation of KoreaWork finacially supported by the 2010 Research Professor Fund of Gyeongsang National University,Korea
文摘Multistage centrifugal impellers with four different skew angles were investigated by using computational fluid dynamics.The purpose of this work is to investigate the influences of lean angle at the blade tip of the impeller inlet.Four variations of lean angles,that is,8°,10°,15° and 20°,were made at first stage impeller.Reynolds Average Navier Stokes equation was used in simulation together with a shear?stress transport(SST) k-w turbulence model and mixing-plane approach,respectively.Three dimensional fluid flows were simplified using periodic model to reduce the computational cost and time required.A good performance was expected that the secondary flow can be effectively reduced in the flow passage of the impeller without excessive increase in manufacturing cost caused by the secondary flow.The results show that secondary flow affects the main flow intricately to form vortices or having non-uniform velocity in the flow passage,which in turn results in substantial fluid energy loss not only in the impeller but also in the guide vane downstream of impeller.The numerical solutions were performed and allowed the optimum design and operating conditions to be obtained.
基金supported by Author Special Foundation of National Excellent Doctoral Dissertation of China (Grant No. 2007B41)Jiangsu Provincial Foundation of "333 Talents Engineering" of ChinaJiangsu Provincial Academic Header Foundation of Qinglan Engineering of China
文摘Baoying pumping station is a part of source pumping stations in East Route Project of South-to-North Water Transfer in China. Aiming at the characteristics of head varying, and making use of the function of pump adjustable blade, mathematical models of pumping station optimal operation are established and solved with genetic algorithm. For different total pumping discharge and total pumping volume of water per day, in order to minimize pumping station operation cost, the number and operation duties of running pump units are respectively determined at different periods of time in a day. The results indicate that the saving of electrical cost is significantly effected by the schemes of adjusting blade angles and time-varying electrical price when pumping certain water volume of water per day, and compared with conventional operation schemes (namely, the schemes of pumping station operation at design blade angles based on certain pumping discharge), the electrical cost is saved by 4.73%-31.27%. Also, compared with the electrical cost of conventional operation schemes, the electrical cost is saved by 2.03%-5.79% by the schemes of adjusting blade angles when pumping certain discharge.
文摘Contra-rotating axial flow fan is a kind of the vital equipment in coal mines. Their work conditions directly affect the safety of staff and production. In the paper, the performance of the contra-rotating axial flow fan is experi- mentally investigated. The study is focused on the fan performance, the shaft power and the match between the motor and fan efficiency at different blade angles. The results show that the blade angle 43°/26° has the best aerodynamic perfor- mance. The first engine has a greater impact on the fan than the second one. The blade angle with the best aerodynamic performance does not necessarily correspond to the one with the best match between the motor and fan efficiency. The blade angle 43°/24° is the best choice for the operation of the fan in the present study.
文摘Mini turbo-pumps having a diameter smaller than 100mm are employed in many fields;automobile radiator pump,ventricular assist pump,cooling pump for electric devices,washing machine pump and so on.Further,the needs for mini turbo-pumps would become larger with the increase of the application of it for electrical machines.It is desirable that the mini turbo-pump design is as simple as possible due to restriction to make precise manufactures.But the design method for the mini turbo-pump is not established because the internal flow condition for these small-sized fluid machineries is not clarified and conventional theory is not conductive for small-sized pumps.Three types of rotors with different outlet angles are prepared for an experiment and a numerical analysis.The performance tests are conducted with these rotors in order to investigate the effect of the blade outlet angle on performance and internal flow condition of mini turbo-pumps.It is clarified from the experimental results that head of the mini turbo-pump increases and maximum efficiency flow rate shifts to larger flow rate according to the increase of the blade outlet angle,however the maximum efficiency decreases with the increase of it.In the present paper,the performance of the mini turbo-pump is shown and the internal flow conditions are clarified with the results of the experiment and the numerical flow analysis.Furthermore,the effects of the blade outlet angle on the performance are investigated and high performance design with simple structure for the mini turbo-pump would be considered.
基金supported by National Natural Science Foundation of China granted No.50976105,No.51276172Zhejiang Provincial Natural Science Foundation Granted No.R1100530
文摘In order to analyze the influence of blade outlet angle on inner flow field and performance of low-specific-speed centrifugal pump, the flow field in the pump with different blade outlet angles 32.5°and 39° was numerically calculated. The external performance experiment was also carried out on the pump. Based on SIMPLEC algorithm, time-average N-S equation and the rectified k-ε turbulent model were adopted during the process of computation. The distributions of velocity and pressure in pumps with different blade outlet angles were obtained by calculation. The numerical results show that backflow areas exist in the two impellers, while the inner flow has a little improvement in the impeller with larger blade outlet angle. Blade outlet angle has a certain influence on the static pressure near the long-blade leading edge and tongue, but it has little influence on the distribution of static pressure in the passages of impeller. The experiment results show that the low-specific-speed centrifugal pump with larger blade outlet angle has better hydraulic performance.
基金supported by the National Natural Science Foundation of China(Grant No.51176088)
文摘By model test and numerical simulation, this paper analyzed the effects of different blades with varying rotation angle deviations on the hydraulic performance of a mixed-flow pump. It was found that when some blades had rotation angle deviations, the hydraulic performance curves of the mixed-flow pump would move. With a positive deviation, the curves moved towards the large flow rate; with a negative deviation, the curves moved towards the small flow rate. When some blades had rotation angle deviations, the symmetry and uniformity of the pressure distribution inside the mixed-flow pump flow passage both decreased; the larger the deviation, the greater the decrease. When a single blade had a large rotation angle deviation, a rather clear low pressure area was formed, lowering the cavitation performance. When two adjacent blades changed simultaneously, under the small flow rate condition, adverse pressure gradient and flow separation occurred in the flow field, and a hump appeared in the head curve and the operation stability of the mixed-flow pump dropped significantly. Near the best efficiency point(BEP), the simultaneous change of two alternate blades produced a more significant change of pressure in the flow passage, with an even larger area. Compared to the effect of two adjacent blades, two alternate blades, when changed simultaneously, made the mixed-flow pump slightly less efficient, but with a flatter efficiency curve and relatively wider high efficiency area. By fitting the test results, a functional relation among the BEP of the mixed-flow pump QBEP, the number of deviated blades N, and blade rotation angle deviation α was established, thus realizing an effective prediction of the BEP of the mixed-flow pump when blade rotation angles have deviations.
基金National Science and Technology Major Project(2017-II-0009-0023)National Nature Science Foundation of China(51976172)。
文摘It is well known that fan/compressor blade flutter stability increases with the increase of reduced frequency.Less well-known is that the least stable inter blade phase angle(IBPA)increases with the drop of reduced frequency.However,it is quite striking that little can be found in the open literature about the mechanism to the observations.In this paper,a numerical investigation is carried out to uncover the mechanism of the effect of reduced frequency on flutter stability and the least stable IBPA.The NASA rotor 67 has been used as the test vehicle with its first bending and torsion modes being considered.The time domain harmonic balance method together with the influence coefficient method is used to obtain the worksum-IBPA curves for all cases.It is found that:1)the deterioration of flutter stability with the decrease of reduced frequency is dictated by the dominant decrease of aerodamping due to a blade own vibration;2)the increase of the least stable IBPA with the decrease of reduced frequency arises largely from the increase of the least stable IBPA of the aerodamping from the nearest blade on a blade pressure side.
基金supported by National Natural Science Foundation of China(No.51879122,51579117,51779106)National Key Research and Development Program of China(Grant No.2016YFB0200901,2017YFC0804107)+5 种基金Zhenjiang key research and development plan(GY2017001,GY2018025)the Open Research Subject of Key Laboratory of Fluid and Power Machinery,Ministry of Education,Xihua University(szjj2017-094,szjj2016-068)Sichuan Provincial Key Lab of Process Equipment and Control(GK201614,GK201816)Jiangsu University Young Talent training Program-Outstanding Young backbone TeacherProgram Development of Jiangsu Higher Education Institutions(PAPD)Jiangsu top six talent summit project(GDZB-017)。
文摘In order to study the variation of brake torque,vibration,pressure fluctuation,exterior noise and internal flow for a hydraulic retarder with different inclination angles and liquid-filled amount,a bench-scale hydraulic retarder was built.The INV3020 data collection system was used for the synchronous acquisition of brake torque,vibration,pressure fluctuation and exterior noise signals.Experiments were performed with different inclination angles(90°and 75°)and six liquid-filled amount(50 vol%,60 vol%,70 vol%,80 vol%,90vol%and 100 vol%).The torque-volume ratio was proposed to accurately analyze the influence of inclination angle on the liquid volume in stator and rotor and the brake performance.Mixture multiphase flow model was employed to capture the volume and velocity distribution.The research shows that the brake performance improves and the vibration increases with the decrease of inclination angle and the increase of liquid-filled amount.The pressure fluctuation increases as the liquid-filled amount increases,while the lower inclination angle effectively lowers the pressure fluctuation amplitude.The sound pressure level trends upward with increasing liquid-filled amount,and the lower inclination angle can effectively reduce the noise.The volume distribution of the liquid phase under different liquid-filled amount is basically consistent.The lower inclination angle can induce more vortexes.
基金support from the National Natural Science Foundation of China(No.51406204)
文摘With the improvement of requirement,design and manufacture technology,aero-engines for the future are characterized by further reduction in fuel consumption,cost,but increment in propulsion efficiency,which leads to ultra-high bypass ratio.The intermediate turbine duct(ITD),which connects the high pressure turbine(HPT) with the low pressure turbine(LPT),has a critical impact on the overall performances of such future engines.Therefore,it becomes more and more urgent to master the design technique of aggressive,even super-aggressive ITDs.Over the last years,a lot of research works about the flow mechanism in the diffuser ducts were carried out.Many achievements were reported,but further investigation should be performed.With the aid of numerical method,this paper focuses on the change of performance and flow field of ITD,as well as nearby turbines,brought by rising angle(RA).Eight ITDs with the same area ratio and length,but different RAs ranges from 8 degrees to 45 degrees,are compared.According to the investigation,flow field,especially outlet Ma of swirl blade is influenced by RA under potential effect,which is advisable for designers to modify HPT rotor blades after changing ITD.In addition to that,low velocity area moves towards upstream until the first bend as RA increases,while pressure loss distribution at S2 stream surface shows that hub boundary layer is more sensitive to RA,and casing layer keeps almost constant.On the other hand,the overall total pressure loss could keep nearly equivalent among different RA cases,which implies the importance of optimization.
基金the 13th Five-Year Plan for National Science and Technology(Grant No.2016YFD0700302,20140309001NY)Natural Science Foundation of China(51305158).
文摘In the cold areas of Northeast China,maize high-stubble cutting is a novel stalk conservation tillage method,in which the maize stalks are under a unilaterally-fixed no-support cutting status.Thus,reducing the cutting resistance and power consumption of maize stalks under this status is very significant for the development of high-efficiency high-stubble cutting devices.Based on a self-designed testing system that highly restored the maize high-stubble cutting conditions and by means of experimental design and mathematic statistics,the effects of working parameters(blade angle,blade shape,cutting speed and cutting angle)on the maximum cutting resistance and power consumption were studied.By analyzing stress conditions during the stalk cutting process,six mathematic models were built to express the relationships between individual factors and the maximum cutting resistance or cutting power consumption.Through model optimization,the parameter combination for optimal cutting performance of maize stalks under unilaterally-fixed no-support cutting status was obtained:blade angle is 18°,blade shape is isosceles triangle,cutting speed is 9.5 m/s,and cutting angle is 75°.Field validation experiments under this parameter combination showed that the maximum cutting resistance was(55.23±3.50)N(declined by 11.04%),and power consumption was(11.41±1.04)J(declined by 16.65%).The research findings can be a reference for the design and development of maize high-stubble cutting devices.
基金European Horizon 2020 grant 644971 and Innovate UK grant 104021.
文摘This paper presents the design of a centrifugal compressor for high-speed turbomachinery.The main focus of the research is to develop a centrifugal compressor with improved aerodynamic performance.As a meridional frame has a significant effect on overall performance of the compressor,special attention has been paid to the end wall contours.The shroud profile is design with bezier curve and hub profile with circular arc contour.The blade angle distribution has been arranged in a manner that it merges with single value at impeller exit.The rake angle is positive at leading edge and negative at trailing edge with identical magnitude.Furthermore,three-dimensional straight line element approach has been used for this design for better manufacturability.The verification of the aerodynamic performance has been carried out using CFD software with consideration of a single blade passage and vaneless diffuser.The result has been compared with matching size aftermarket compressor stage gas stand data.The compressor stage with Trim 55 provides 34%increase in choke flow at 210000 RPM as compared to gas stand data with 87%peak stage efficiency at 110000 RPM.In addition,new surge margin improvement technique has been proposed by means of diffuser enhancement.This technique provides an average of 16%improvement in surge margin compared to standard diffuser stage with 55 trim compressor impeller.The mechanical integrity has been validated at maximum RPM with the aluminum alloy 2014-T6 as a fabrication material.
基金supported by the National Natural Science Foundation of China(No.51475022)。
文摘In this study,the lock-in phenomenon of Tip Clearance Flow(TCF)instabilities and their relationship to blade vibration are investigated numerically on an axial transonic rotor with a large tip clearance.The capabilities of simulating instability flow and lock-in phenomenon are verified on a transonic rotor and a NACA0012 airfoil by comparing with the test data,respectively.The lock-in phenomenon is first numerically confirmed that may occur to TCF instabilities when its frequency is close to the blade vibration frequency.The lock-in region becomes wider with the vibration amplitude increasing,and it is also affected by modal shapes.For the rotor at the simulation conditions in this study,the bending mode results in a wider lock-in region than the torsional mode.In the lock-in region,the phase difference between the Tip Clearance Vortex(TCV)and the blade vibration changes with the flow condition and the frequency ratio of the blade vibration and the TCV instabilities.The frequency of the TCV instabilities reduces with the mass flow decreasing.Therefore,reducing mass flow and increasing frequency ratio have similar effects on the TCV phase,which causes a significant variation on the unsteady pressure amplitude in the blade tip area.Thus,the aerodynamic damping changes significantly with the TCV phase.The aerodynamic damping displays a nonlinear relationship with the vibration amplitude,and it changes from negative to positive with the vibration amplitude increasing at the same frequency ratio.The negative damping is mainly provided by the tip area of the blade.For unlocked conditions,the period of the TCF instabilities fluctuates over time,and it cannot be directly separated by their frequency features.Inter Blade Phase Angle(IBPA)also has an important influence on the feature of the TCV instabilities.The occurrence of frequency lock-in also requires“appropriate”IBPA.For the examined working conditions,the frequency lock-in occurs under 0 ND(Nodal Diameter),but not under 8 ND.However,no matter 0 ND or 8 ND,the phase of TCV always locks onto the IBPA at the examined conditions.
文摘The flow characteristics of the centrifugal fans with different blade outlet angles are basically discussed on steady and unsteady simulations for a rectangular casing fan. The blade outlet angles of the impellers are 35° and 25° respectively. The unsteady flow behavior in the passage of the impeller 35° is quite different from that in the steady flow behavior. The large flow separation occurs in the steady flow field and unsteady flow field of the impeller 35°, the flow distribution in the circumferential direction varies remarkably and the flow separation on the blade occurs only at the back region of the fan; but the steady flow behavior in the impeller 25° is almost consistent with the unsteady flow behavior, the flow distribution of the circumferential direction doesn't vary much and the flow separation on the blade hardly occurs. When the circumferential variation of the flow in the impeller is large, the steady flow simulation is not coincident to the unsteady flow simulation.